Check a Pulse! When to Question SpO 2, NIBP & EtCO 2 Readings

Similar documents
Capnography: The Most Vital Sign

Interesting Capnography Cases

Capnography Could Make You a Rock Star!

Capnography 101. James A Temple BA, NRP, CCP

How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve

Wilson County Emergency Management Agency Protocol Manual Protocols

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

Accuracy of Noninvasive Carboxyhemoglobin Measurements from the Rad-57: Analysis of a Recent Study by Touger et al

NOTE: CONTENT CONTAINED IN THIS DOCUMENT IS TAKEN FROM ROSEN S EMERGENCY MEDICINE 9th Ed.

ADVANCED PATIENT MONITORING DURING ANAESTHESIA: PART ONE

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

What is. InSpectra StO 2?

Endorsements. Review Board. Pulse Oximetry and CO Oximetry 6/13/2007. Oximetry and CO-Oximetry for EMTs and

Don t let your patients turn blue! Isn t it about time you used etco 2?

X Series Extensive Capabilities

Carbon Monoxide Exposure: Dräger PAC 3500 & RAD-57

Capnography: Not just for confirmation

Appendix E Choose the sign or symptom that best indicates severe respiratory distress.

Capnography- A Review and Renewed Perspective of its Uses and Limitations

Dr. D.McG.Clarkson Determining the Accuracy of SpO2 Values

Are Patients Hypoperfused in the ED? Rapid Perfusion Assessment in the Emergency Department

Biomedical Instrumentation E. Blood Pressure

Capnography: The Most Vital of Vital Signs. Tom Ahrens, PhD, RN, FAAN Research Scientist, Barnes-Jewish Hospital, St. Louis, MO May, 2017

CAPNOGRAPHY. 1.1 To set forth the policy and procedure for performing continuous end-tidal waveform capnography.

3/30/12. Luke J. Gasowski BS, BSRT, NREMT-P, FP-C, CCP-C, RRT-NPS

Assessing Global Patient Status with the Halo Index

INTUBATION/RSI. PURPOSE: A. To facilitate secure, definitive control of the airway by endotracheal intubation in an expeditious and safe manner

Introduction. Invasive Hemodynamic Monitoring. Determinants of Cardiovascular Function. Cardiovascular System. Hemodynamic Monitoring

ORIGINAL RESEARCH. Effect of road traffic accident contaminants on pulse oximetry among normoxaemic volunteers

Images have been removed from the PowerPoint slides in this handout due to copyright restrictions.

A GUIDE TO OUR NIBP TECHNOLOGY

Testing Masimo rainbow Technology with vpad-a1 1. Background

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Non-Invasive Assessment of Respiratory Function. Chapter 11

Choosing Mindray SpO2

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD.

Appendix D An unresponsive patient with shallow, gasping breaths at a rate of six per minute requires:

Respiratory Physiology & Neurobiology

The role of pulse oximetry in the accident and emergency department

Infinity MCable -Masimo SET

Julie Zimmerman, MSN, RN, CCRN Clinical Nurse Specialist

Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology

How it Works. CO 2 is the smoke from the flames of metabolism 10/21/18. -Ray Fowler, MD. Metabolism creates ETC0 2 for excretion

Blood Pressure Estimation Using Photoplethysmography (PPG)

June 2011 Bill Streett-Training Section Chief

Monitoring in Anesthesia

IDENTIFYING SEPSIS IN THE PREHOSPITAL SETTING

Guidelines Administrative Practice X Clinical Practice Professional Practice

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

Chapter 11. Objectives. Objectives 01/09/2013. Baseline Vital Signs, Monitoring Devices, and History Taking

When Cyanosis is the Norm. Steven M. Schwartz, MD, FRCPC Cardiac Critical Care Medicine The Hospital for Sick Children Toronto

Pulse. Assess for the following:

Chapter 9 Vital Signs and SAMPLE History DOT Directory

Capnography Connections Guide

TECHNOCARE MEDISYSTEMS

Advanced Cardiac Life Support (ACLS) Science Update 2015

Anaesthesia for ECT. Session 2. Dr Richard Cree Consultant in Anaesthesia & ICU. Roseberry Park Hospital and The James Cook Hospital, Middlesbrough

Essentials of Anaesthetic Monitoring in Veterinary Practice

FloTrac Sensor and Edwards PreSep Central Venous Oximetry Catheter Case Presentations

MASTER SYLLABUS

Albany Medical Center:

Non-Invasive Monitoring

AVOIDING THE CRASH: OPTIMIZE YOUR PRE, PERI, AND POST AIRWAY MANAGEMENT AVOIDING THE CRASH 1: DON T INTUBATE, OPTIMIZE PRE-AIRWAY MANAGEMENT

They aren t the same thing. Daniel Dunham

ENDORSEMENTS This educational module has been endorsed by the following professional organizations:

ETCO2 MONITORING NON-INTUBATED PATIENTS

Empowering the RT with New Noninvasive Monitoring Capabilities

SUMMARY OF MAJOR CHANGES 2010 AHA GUIDELINES FOR CPR & ECC

Biomedical Instrumentation D. The Photoplethysmogram

Carboxyhemoglobin levels in carbon monoxide poisoning: do they correlate with the clinical picture?

2. Measure a subject's blood pressure and heart rate both at rest and during exercise.

Feeling Blue? Aaron St-Laurent Montreal Children s Hospital Pulmonology Cross Canada Rounds

Northwest Community EMS System Continuing Education Class Credit Questions Respiratory Assessment January 2012

ASPIRUS WAUSAU HOSPITAL, INC. Passion for excellence. Compassion for people. SUBJECT: END TIDAL CARBON DIOXIDE MONITORING (CAPNOGRAPHY)

Defibrillators TEC-8300K series. It s all seamless

Research Journal of Pharmaceutical, Biological and Chemical Sciences

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014

IFT1 Interfacility Transfer of STEMI Patients. IFT2 Interfacility Transfer of Intubated Patients. IFT3 Interfacility Transfer of Stroke Patients

Non-Invasive Method of Blood Pressure Measurement Validated in a Mathematical Model

Incorporating Waveform Capnography into Resuscitation Practice: Why & How!

Pulse. Oximetry: Uses. and. Limitations. Susan DeMeulenaere. Continuing Education

Respiratory Failure in the Pediatric Patient

Sepsis Bundle Project (SEP) Kathy Wonderly RN, MSEd, CPHQ Consultant Developed: April 2015 Most recent Revision: December 2018

Non-Invasive Respiratory monitoring

Tracheostomy Sim Course

Vital Signs and SAMPLE History

County of Santa Clara Emergency Medical Services System

Staging Sepsis for the Emergency Department: Physician

Online Supplementary Appendix

March 2009 CE. Site code # E Carbon Monoxide, Smoke Inhalation, Cyanide Poisoning and Medical Rehab

Anaesthetic considerations for laparoscopic surgery in canines

DETECTING METHODS OF ENDOTRACHEAL TUBE POSITION

Non-Invasive PCO 2 Monitoring in Infants Hospitalized with Viral Bronchiolitis

Resuscitation Patient Management Tool May 2015 MET Event

ACLS Prep. Preparation is key to a successful ACLS experience. Please complete the ACLS Pretest and Please complete this ACLS Prep.

Airway Management Essentials Self-Study Guide

Lab A Overview. Oxygenation. Ventilation. Anatomy. Prep Yourself. Prep Your Team. Prep Your Patient. Prep Your Stuff.

Rethinking Arterial Catheters in the ICU. Allan Garland, MD, MA Professor of Medicine & Community Health Sciences University of Manitoba

By Mark Bachand, RRT-NPS, RPFT. I have no actual or potential conflict of interest in relation to this presentation.

Transcription:

Check a Pulse! When to Question SpO 2, NIBP & EtCO 2 Readings Mike McEvoy, PhD, RN, CCRN, NRP Professor Emeritus - Critical Care Medicine Albany Medical College Albany, New York Chair Resuscitation Committee Albany Med Ctr EMS Coordinator Saratoga County, New York EMS Editor Fire Engineering magazine Learning Objectives Upon completion of the presentation the participant will: 1. Recall two common sources of user error in noninvasive vital sign measurement 2. Discuss the methodology used to obtain a noninvasive blood pressure reading 3. State one response of a pulse oximeter when unable to detect a pulse Class Code: 666 While charting SpO 2 alarms 74% Case # 1 - Desaturation Patient in no distress, good color Repositioning sensor yields same 74% sat ABG shows 98% sat

Well appearing patient, 74% SpO 2 Why me? Case # 2 O 2 Sat Out Of Nowhere Patient discharged 2 hours ago Mysterious waveform and 100% sat Model of Light Absorption At Measurement Site Without Motion Absorption Time AC Variable light absorption due pulsatile volume of arterial blood DC Constant light absorption due to non-pulsatile arterial blood. DC Constant light absorption due to venous blood. DC Constant light absorption due to tissue, bone,...

Model of Light Absorption At Measurement Site With Motion Absorption Time AC Variable light absorption due pulsatile volume of arterial blood DC Constant light absorption due to non-pulsatile arterial blood. AC Variable light absorption due to moving venous blood DC Constant light absorption due to venous blood. DC Constant light absorption due to tissue, bone... Influence of Perfusion on Accuracy of Conventional Pulse Oximetry During Motion Good Perfusion (Conventional PO) SpaO 2 =98 SpvO 2 =88 SpO 2 =93 Poor Perfusion (Conventional PO) SpaO 2 =98 SpvO 2 =50 SpO 2 =74 Conventional Pulse Oximetry Algorithm R & IR Digitized, Filtered & Normalized R/IR MEASUREMENT CONFIDENCE Post Processor % Saturation 3 options during motion or low perfusion: 1. Freeze last good value 2. Lengthen averaging cycle 3. Zero out

Next Generation Pulse Oximetry Next Generation Pulse Oximetry Masimo SET: Signal Extraction Technology R/IR (Conventional Pulse Oximetry) MEASUREMENT CONFIDENCE MEASUREMENT DST TM CONFIDENCE R & IR Digitized, Filtered & Normalized FST TM MEASUREMENT CONFIDENCE Confidence Based Arbitrator Post Processor % Saturation DST SET 97% MEASUREMENT SST TM CONFIDENCE 0 50% 66% 97% 100% SpO2% Proprietary Algorithm 4 MEASUREMENT CONFIDENCE Masimo SET Parallel Engines SET Parallel Engines

A Solution for Patient Motion Discrete Saturation Transform (DST) In the presence of motion, SET separates the venous and arterial saturation values resulting in accurate saturation readings without false alarms (compared to conventional oximetry that averages the values to produce a reading) Variable Averaging - inaccurate SpO 2 Constant Variable Constant Separating - accurate SpO 2 0 50% 66% 86% 97% 100% SpO 2% Conventional Pulse Oximetry 0 50% 66% 86% 97% 100% SpO 2% Measure Through Motion Pulse Oximetry Certainty Case # 3 Smoke Inhalation ED Triage Desk: 35 yo male presents with diff breathing States, My furnace exploded. Soot in mouth/nares O 2 sat 98%

Gas: Colorless Odorless Tasteless Nonirritating Carbon Monoxide (CO) Physical Properties: Vapor Density = 0.97 LEL/UEL = 12.5 74% IDLH = 1200 ppm Limitations of Pulse Oximetry Conventional pulse oximetry can not distinguish between COHb, and O 2 Hb From Conventional Pulse Oximeter SpCO-SpO 2 Gap: The fractional difference between actual SaO 2 and display of SpO 2 (2 wavelength oximetry) in presence of carboxyhemoglobin From invasive CO- Oximeter Blood Sample [Blood] Barker SJ, Tremper KK. The Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous PO 2. Anesthesiology 1987; 66:677-679 CO: The Leading Cause of Poisoning Deaths 30-50 % of CO-exposed patients presenting to Emergency Departments are misdiagnosed Barker MD, et al. J Pediatr. 1988;1:233-43 Barret L, et al. Clin Toxicol. 1985;23:309-13 Grace TW, et al. JAMA. 1981;246:1698-700

Pulse CO-oximetry Hgb Signatures: CO, Met, Hgb 14,438 Patient Brown University Study Partridge and Jay (Rhode Island Hospital, Brown University Medical School), assessed carbon monoxide (CO) levels of 10,856 ED patients 11 unsuspected cases of CO Toxicity (COT) were discovered. Overall mean SpCO was 3.60% Occult COT was 4 in 10,000 during cold, 1 in 10,000 during warm months They concluded unsuspected COT may be identified using noninvasive COHb screening and the prevalence of COT may be higher than previously recognized Non-Invasive Pulse CO-Oximetry Screening in the Emergency Department Identifies Occult Carbon Monoxide Toxicity. Suner S, Partridge R, Sucov A, Valente J, Chee K, Hughes A, Jay G. J Emerg Med 2008 Department of Emergency Medicine, Rhode Island Hospital, Brown Medical School, Providence, RI.

Problems: Accuracy Motion & artifact Dyshemoglobins Pulse Oximetry Case # 4 Which Pressure Is Right? 78 yo trauma patient BP A-line = 70/42 (50) NIBP = 90/50 (52) Blood Pressure Monitoring Direct Pressure vs Indirect Flow

Errors in BP Measurement Cuff Size: Too large = BP Too small = BP 2/3 extremity length Mid Heart Level: Higher = BP Lower = BP Best sitting, arm @ side How does NIBP work? Measures flow (pulsatile) Determines HR and MAP By formula, calculates SBP and DBP Subject to same interferences as auscultated BP Important to confirm HR (if wrong, SBP and DBP wrong) Mean Arterial Pressure (MAP) A clinical parameter useful in assessing perfusion Represents the average pressure within the arterial system throughout the cardiac cycle MAP = 2 (diastolic) + systolic 3 2/3 time in diastole only when HR = 70

150 90 60 28 Waveform Capnography Available for spontaneously breathing and for intubated patients Case # 5 Bad Day in OR 37 yo male cholecystectomy No significant PMH, smooth induction Shortly after incision, EtCO 2 gradually declines Manual BVM with good compliance & chest rise???

Circulation The heart and lungs are inextricably linked together Cardiac Arrest! Little O2 delivery or consumption Little CO2 production or venous return CO 2 Clearance Reflects Perfusion In other words: CO 2 production is largely dependent on oxygen consumption!

Case # 6 Misplaced ETT? Cardiac arrest on med-surg floor CRNA intubates without difficulty, visualizes tube pass through cords EtCO 2 circuit connected = flatline??? Circuit Connector Case # 7 EtCO 2 PaCO 2 Post CABG patient EtCO 2 drops to 6 ABG PaCO 2 = 48 mmhg Why?

Another Cause of Low EtCO 2 Profound metabolic acidosis ph = 6.93 Questions? Slides available at: www.mikemcevoy.com Class Code = 666