Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

Similar documents
Elekta Synergy Digital accelerator for advanced IGRT

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

IMRT Planning Basics AAMD Student Webinar

iviewdose Confidence and assurance in dose delivery

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams

Elekta Infinity Digital accelerator for advanced treatments

PRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT

typical IMRT fraction time and expand high definition radiotherapy anywhere in the body with the widest range of motion of the

A UNIQUELY SMART RADIATION THERAPY SYSTEM

I. Equipments for external beam radiotherapy

A UNIQUELY SMART RADIATION THERAPY SYSTEM

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Patient and Linac QA - present and the future

2016 Billing and Coding Reference. Stereotactic Treatment Delivery

Quality assurance in external radiotherapy

Protura Robotic Patient Positioning System. for efficiency + performance

7/31/2012. Volumetric modulated arc therapy. UAB Department of Radiation Oncology. Richard Popple, Ph.D.

MEDICAL PHYSICS INTERNATIONAL Journal, vol.3, No.2, 2015 HOW TO

Implementation of advanced RT Techniques

Trilogy Stereotactic System Stereotactic, IMRT, and 3D CRT in one system

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Dosisverifikation mit Delta 4 Discover während der Behandlung

Debate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete

SunCHECK Patient Comprehensive Patient QA

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Elekta - a partner and world-leading supplier

Nuclear Associates

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Cyberknife Stereotactic Treatment

IMAGE-GUIDED RADIATION THERAPY

QUALITY ASSURANCE IN RADIOTHERAPY THERAPY EQUIPMENT

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Eric E. Klein, Ph.D. Chair of TG-142

Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA

National System for Incident Reporting in Radiation Therapy (NSIR-RT) Taxonomy

Quality assurance of volumetric modulated arc therapy using Elekta Synergy

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

MOTION MANAGEMENT & PATIENT SAFETY REDEFINED!

Clinical experience with planning, quality assurance, and delivery of burst-mode modulated arc therapy

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Electron Beam ET - Reloaded Therapy - Reloaded

A new geometric and mechanical verification device for medical LINACs

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

The Canadian National System for Incident Reporting in Radiation Treatment (NSIR-RT) Taxonomy March 11, 2015

CONFIDENCE IN THE OUTCOMES THAT MATTER MOST TO YOU

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times

3D-CRT Breast Cancer Planning

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation. Research and development to advance radiotherapy

EORTC Member Facility Questionnaire

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Importance of daily portal imaging for Head and Neck IMRT treatments. Luciant Wolfsberger Brigham & Women s Hospital

RTOG DOSIMETRY DATA SUBMISSION

MOSAIQ TM Image Enabled EMR. managing the spectrum of cancer care. Filmless and paperless workflow Universitätsklinikum Mannheim

A Patient s Guide to SRS

VARIAN ONCOLOGY. RapidArc. One revolution is all it takes.

Small field diode dosimetry

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Amendment No. 2. Item No. 2 (Rfx/ Event number )

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

02 CyberKnife: Treatment Delivery

Universal Couchtop. for safe, efficient treatment planning + imaging. Long Extension. 1 Piece

1ª Jornada de Análisis de Riesgos en RT. 10 de Dic 2014 José Luis Roldán

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

A method to predict patient specific table coordinates for quality assurance in external beam radiation therapy

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

Radiotherapy and Radiosurgery

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

Clinical Implications of High Definition Multileaf Collimator (HDMLC) Dosimetric Leaf Gap (DLG) Variations

EPID dosimetry for pretreatment quality assurance with two commercial systems

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT

Your Global Quality Assurance Platform All-in-One. All Connected. All Secure.

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

The Radixact System Experience at Miami Cancer Institute. Tino Romaguera, D.Sc. Senior Physicist

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

FEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Many vendors are beginning to allow couch motion during radiation delivery.

Transcription:

Varian Treatment Streamlined Treatment Delivery Management Application Specifications

Specifications Varian Treatment 1 Introduction Streamlined Treatment Delivery Management Varian Treatment verifies treatment parameters for a wide variety of radiation therapy treatments with linear accelerators manufactured by Siemens and Elekta. By unifying plan and delivery information into a single workspace, users can easily verify treatment setups for patients. Key Functionality Provides uniformity to the treatment delivery process Uses a standard DICOM-RT interface to exchange patient data with Varian s ARIA oncology information system Combines patient, plan, and treatment parameters into a single workspace Provides validation checks of treatment parameters to ensure safe and accurate treatment delivery with each patient session Accelerates the treatment process with plan validation and helps reduce the potential for random errors by automating data entry Sends treatment data (e.g., records and acquired images) to the Varian system database where it is recorded to the patient s chart Supports quality assurance (QA) measurements with the actual treatment plan using Plan QA mode

Specifications Varian Treatment 2 Specifications 1.0 General Use Radiation therapy treatment delivery with medical linear accelerators 2.0 Treatment Techniques Varian Treatment supports the following external beam radiation therapy: 2D conventional 3D conformal Arc therapy Intensity-modulated radiation therapy (IMRT) Volumetric modulated arc therapy (VMAT) Stereotactic radiation therapy (SRT) 3.0 Treatment Tasks Varian Treatment is a treatment delivery management application that provides verify-and-record functions for supported 1 medical linear accelerators. The user-centric interface intuitively enables therapists to visualize and carry out treatment tasks with confidence and increased efficiency. With Varian Treatment, users are able to easily verify the actual setup against the approved prescription and are prevented from proceeding if the two do not match or are out of tolerance. Upon completion of treatment, Varian Treatment sends the treatment history and acquired images back to the Varian system database where clinical staff can view the information from nearly any area of the department using the ARIA client applications. 3.1 Parameter Verification Varian Treatment verifies the following treatment parameters against the machine parameters including operating limits during setup: Technique Energy Monitor units (MU) Patient support (couch): vertical, lateral, longitudinal, rotation Gantry angle, stop angle, start angle, direction Multileaf collimator Jaws Accessories Trays, blocks, compensators Custom 2 o Blocks, bolus Physical and dynamic wedges Electron applicators Fitments 3.2 Standard Treatment Tasks For standard treatments, Varian Treatment: Loads approved plans and reference images from the ARIA oncology information system Verifies patient-specific accessories Allows for field reordering Allows users to acquire machine parameters Allows users to edit 3 treatment plan parameters Allows treatment resumption of a partially treated plan 1 Supported machines listed on page 5 2 Requires manual verification and authorization 3 Allows only minor edits of couch translational values for approved treatment plans

Specifications Varian Treatment 3 Provides support for single and multiple isocenter plans Provides auto field sequencing support Records treatment data (e.g., treatment records and acquired images) to the Varian system database once the patient plan is closed Records dose to the reference point that is associated with the treatment plan Allows users to complete quality assurance measurements using the actual treatment plan or a verification plan Allows users to create and to deliver an emergency treatment plan from the Varian Treatment application 3.3 Overrides Varian Treatment allows users with appropriate rights to override the following: Treatment machine Switch of patient plans between dosimetric equivalent machines of the same manufacturer Machine parameter Couch orientation: vertical, lateral, longitudinal, rotation Collimator (also known as jaws) Gantry angle Dose limit Overrides are recorded to the patient s chart for auditing purposes. 3.4 Imaging Varian Treatment allows imaging of setup and treatment fields using scheduled or ad-hoc image sequence templates for MV port films or electronic portal images. Add accessory during port film/image acquisition Sends acquired image data to ARIA, where it is available for review Supports manual or automated DICOM-RT image retrieval from Elekta s iviewgt R3.4 or higher 3.5 Patient Setup View patient demographics, fraction and plan information, actual versus planned parameters, setup photos (two per treatment field) and patient setup notes for the loaded field from the in-room monitor while setting up the patient 3.6 Network Independence Download entire treatment plan Complete treatment session without interruption if network connectivity is lost Saves patient treatment data to the Varian system database once connectivity is restored 4.0 System Components 4.1 Charge Capture Charge Capture records the appropriate Current Procedural Terminology (CPT ) codes for treatment and imaging activities to the Varian system database for auditing and billing purposes. 4.2 PAVS and VVS The Patient and Accessory Verification System (PAVS) (licensed option) or Varian Verification System (VVS) (licensed option) uses barcode technology to identify patients and verify accessories prior to treatment delivery. Electronic patient selection from queue Patient identification verification from the treatment room Beam interlock until patient and accessories are verified Verification of custom blocks and compensators Includes two barcode scanners, software and label printer

Specifications Varian Treatment 4 4.3 Queue Queue loads the list of scheduled patients to Varian Treatment. Queue provides the following functionality: Patient selection via barcode scanner Patient check in Session management Add/remove patients from daily treatment schedule Display of current day s schedule per treatment machine Audit tracking (user, date, time and location) of patient check in 5.0 Administration Varian Treatment Administration, the administration application for Varian Treatment, manages the following: Machine characterization and parameter configuration Machine operating limits Ad-hoc image sequence templates Independent user management of users, groups, and rights with audit tracking Back-up and restoration of the above information to/from a user-specified location 6.0 Import/Export Interface Supports DICOM RT (Digital Imaging and Communications in Medicine for Radiotherapy) Reference the DICOM conformance statements here: http://www.varian.com/us/oncology/services_and_support/resources/dicom_statements.html Connectivity and communication with Varian Treatment 7.0 Hardware Requirements Hardware for the Varian Treatment system must be supplied by Varian Medical Systems. The Varian Treatment hardware consists of a single workstation, two 27-inch monitors, mouse, keyboard, in-room keypad, MICAP, and cables (such as network, serial, and fiber).

Specifications Varian Treatment 5 8.0 Software Requirements Varian Treatment v13.0 is compatible with ARIA versions 11.0, 13.5, 13.6, 13.7, and 15.1 National language support: English, French, German, Italian, Spanish, and Brazilian Portuguese Machine models supported Varian Treatment v13.0 supports machines manufactured by Elekta and Siemens AG. Varian Treatment supports treatment control systems, interfaces, and protocols as per the table below. Elekta s icom interface must be enabled on the linac. Interfaces and licenses must be purchased from Elekta AB. Siemens Digital Mevatron Interface Protocol (DMIP) must be enabled on the linac. Interfaces and licenses can be purchased from Siemens AG. Applicable standards The specifications declared for Varian Treatment within this document are based on the recommendations of the International Electrotechnical Commission (IEC)/ European Standard (EN) and include not only the below for the declaration of functional performance characteristics. o IEC 61217 (2011) / EN 61217 (2012) Radiotherapy equipment - Coordinates, movements and scales o IEC 62274 (2005) / EN 62274 (2005) Medical electric equipment - Safety of Radiotherapy Record and Verify Systems Linac Vendor Interfaces/ Protocols Machines/ Models MLC Supported Dynamic Wedge Supported IMRT Supported Advanced Treatment Elekta RTD with icom: R7.01 (SP2) (v12.09) SLi Series SLi Plus Series MLCi MLCi2 7, 8 Motorized Wedge 9, 10 YES YES (SL20, SL15, etc.) Beam Modulator 7 Integrity 4 with icom: Precise Series Agility 160MLC 7, 8 Integrity R1.2 (v12.09) Integrity R3.0, R3.1 5, R3.2 5, 6 (v13.0) Synergy Synergy S Infinity Axesse VersaHD Siemens Siemens DMIP 2 CCS 11 versions 4.5, 5.0, 6.0, 6.1, 6.2, 6.3, 6.5 Digital Mevatron K Digital Mevatron M Siemens PRIMUS NO 12 NO NO NO Siemens DMIP 5 (IMRT) CCS 11 versions 6.1, 6.2, 6.3, 6.5 Siemens DMIP 6 (Fast IMRT/IMMAXX) CCS 11 versions 6.5, 9.2 Siemens DMIP 9 (Fast IMRT/IMMAXX) CCS 11 versions 9.2, 11.0 Digital Mevatron K Digital Mevatron M Siemens PRIMUS Digital Mevatron K Digital Mevatron M Siemens PRIMUS/ PRIMART Siemens ONCOR Siemens PRIMUS/ PRIMART Siemens ONCOR 58-MLC Virtual Wedge YES NO 58-MLC Virtual Wedge YES NO 82-MLC Virtual Wedge YES NO 4 Varian Treatment supports language customizations and selections with the Elekta treatment control system. 5 Varian Treatment supports flattening filter free (FFF) energies (6X or 10X) for Elekta machines. 6 Varian Treatment currently does not support high dose rate electrons (HDRE) for Elekta machines. 7 Varian Treatment supports interdigitation with these multileaf collimators (MLC). 8 Varian Treatment supports sliding-window with these multileaf collimators. 9 Varian Treatment supports Elekta advanced treatment techniques (OmniWedge, dynamic, dynamic arc, and VMAT). 10 Elekta treatment control system must be properly licensed by Elekta AB to delivery these treatment techniques. 11 Varian Treatment supports language selections with the Siemens control console software (CCS). 12 Siemens machine outfitted with high performance defining (HPD) collimator.

USA, Corporate Headquarters and Manufacturer Varian Medical Systems, Inc. 3100 Hansen Way Palo Alto, CA 94304 Tel: 650.493.4000 800.544.4636 Fax: 650.493.5637 varian.com Specifications subject to change without notice. Not all features or products are available in all markets. Intended Use Summary Varian Treatment is designed to assist the operator of a radiation therapy device by retrieving treatment plans from the Varian system database for the Radiation Therapy Management module of the ARIA oncology information system, by providing accurate treatment setups, by monitoring setup parameters, by preventing treatment when machine parameters are out of conformance to treatment plan parameters, and by sending the treatment history for recording to the Varian system database. Important Safety Information Radiation treatments may cause side effects that can vary depending on the part of the body being treated. The most frequent ones are typically temporary and may include, but are not limited to, irritation to the respiratory, digestive, urinary or reproductive systems, fatigue, nausea, skin irritation, and hair loss. In some patients, they can be severe. Treatment sessions may vary in complexity and time. Radiation treatment is not appropriate for all cancers. Medical Advice Disclaimer Varian as a medical device manufacturer cannot and does not recommend specific treatment approaches. Individual treatment results may vary. 2013-2017 Varian Medical Systems, Inc. All rights reserved. Varian, Varian Medical Systems, and ARIA are registered trademarks of Varian Medical Systems, Inc. The names of other companies and products mentioned herein are used for identification purposes only and may be trademarks or registered trademarks of their respective owners. RAD 10303C 07/2017