Automated Image Biometrics Speeds Ultrasound Workflow

Similar documents
Automated Volumetric Cardiac Ultrasound Analysis

Echo in a Heartbeat. Article from the customer magazine Medical Solutions, April

ACUSON Sequoia C512 Echocardiography System The ultimate in imaging

ACUSON X150 Ultrasound System. Transducer Options Release 1.0

Tissue Strain Analytics Virtual Touch Tissue Imaging and Quantification

ACUSON Sequoia C256 Echocardiography System. Transducers.

Full ultrasound breast volumes. Faster scans. Streamlined workflow. ACUSON S2000 Automated Breast Volume Scanner. Answers for life.

How can I provide her with the most advanced care?

ACUSON S2000 Ultrasound System. Transducers Release 1.0.

ACUSON Sequoia C512 Echocardiography System. Transducers.

ACUSON S2000 Ultrasound System. Transducers Release 1.6.

PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING

ACUSON X500 Ultrasound System. Transducers

GE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.

ACUSON Sequoia C512 Echocardiography System. Transducers.

ACUSON X150 Ultrasound System

ACUSON SC2000 PRIME Ultrasound System. Precision at the Speed of Life

ACUSON Antares Ultrasound System. Transducers.

British Society of Echocardiography

ACUSON X300 Ultrasound System, Premium Edition. Transducers Release

ACUSON Antares Ultrasound System. Transducers.


ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

B-Mode measurements protocols:

Dobutamine Stress testing In Low Flow, Low EF, Low Gradient Aortic Stenosis Case Studies

Appendix II: ECHOCARDIOGRAPHY ANALYSIS

powerful versatile mobile

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE)

Tissue Doppler Imaging in Congenital Heart Disease

HOW TO SET UP THE ECHO LAB?

3D Total Breast Ultrasound

AIMI-HF PROCEDURE MANUAL TECHNICAL GUIDE FOR ECHOCARDIOGRAPHY. MHI Core Laboratory E. O Meara - J.C. Tardif J. Vincent, G. Grenier, C.

Keywords Artificial Neural Networks (ANN), Echocardiogram, BPNN, RBFNN, Classification, survival Analysis.

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

Rotation: Echocardiography: Transthoracic Echocardiography (TTE)

ECHOCARDIOGRAPHY DATA REPORT FORM

Pioneering the future of general imaging.

When You Need To Know More.

ACUSON Sequoia Echocardiography Platform Advancing the practice of echocardiography through workflow and innovation

Step up to the iu22 The key reasons are now even more compelling

GE Healthcare. Vivid i Cardiovascular ultrasound system

Cardiac ultrasound protocols

Congenital. Unicuspid Bicuspid Quadricuspid

Changing your idea of clinical performance. Philips HD15 PureWave ultrasound system for echocardiography

ABAS Atlas-based Autosegmentation

Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE.

THE first objective of this thesis was to explore possible shape parameterizations

Transducers. ACUSON SC2000 Ultrasound System. Precision at the Speed of Life Release 5.0

Doppler Basic & Hemodynamic Calculations

Course Learning Objectives Sunday, February 17 Friday, February 22

Diagnostic approach to heart disease

The Fontan circulation. Folkert Meijboom

Basic Approach to the Echocardiographic Evaluation of Ventricular Diastolic Function

Transducers. ACUSON SC2000 Ultrasound System. Release 4.0. Answers for life.

Echo Week - Learning Objectives

Echocardiography: Guidelines for Valve Quantification

PROSTHETIC VALVE BOARD REVIEW

Vevo 2100 System Cardio Measurements. Dieter Fuchs, PhD FUJIFILM VisualSonics, Inc.

Measuring cardiac tissue motion and strain

Enhanced Endocardial Boundary Detection in Echocardiography Images using B-Spline and Statistical Method

BLADDERSCAN PRIME PLUS TM DEEP LEARNING

EDITOR S PICK CURRENT STATUS OF FULLY AUTOMATED SOFTWARE WITH THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR THE QUANTIFICATION OF LEFT VENTRICULAR FUNCTION

MITRAL STENOSIS. Joanne Cusack

Echocardiographic Cardiovascular Risk Stratification: Beyond Ejection Fraction

Adult Echocardiography Examination Content Outline

Intuitive. Intelligent. Innovative. General Imaging

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

Cardiovascular hemodynamics in the stress echo lab with open-source software

Focus on your needs. Ultrasound system HS60 SAMSUNG MEDISON CO., LTD. CT-HS60 V1.0-GI-FT EN

Echocardiography. Guidelines for Valve and Chamber Quantification. In partnership with

Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE. Take rugged reliability to challenging conditions.

Assessment of LV systolic function

Background Information

DC-40 Ultrasound System. powerful efficient sleek

25 different brand names >44 different models Sizes mm

5 Working With Measurements

Proven Performance. Enhanced Care.

Top 10 Facts in Contrast Echocardiography. Pamela R. Burgess, BS, RDCS, RDMS, RVT, FASE

Adopted by Council March 2006, Revised March 2012, September 2015

Versana Premier. Care with Confidence. gehealthcare.com

Complete Valvular Heart Apparatus Model from 4D Cardiac CT

Giovanni Di Salvo MD, PhD, FESC Second University of Naples Monaldi Hospital

Cardiac MRI in ACHD What We. ACHD Patients

Intuitive. Intelligent. Innovative. General Imaging

siemens.com/nx3 Scan Smarter. ACUSON NX3 Series

4D Auto LAQ (Left Atrial Quantification)

Confident and Conclusive Diagnosis with Flexible Solutions

Pitfalls and how to avoid them

A Study on Automatic Age Estimation using a Large Database

SAMSUNG. Mobile excellence. Excellence on the Move ULTRASOUND H60. Ultrasound system HM70A with Plus

Conflict of Interests

Automatic cardiac contour propagation in short axis cardiac MR images

좌심실수축기능평가 Cardiac Function

Doppler-echocardiographic findings in a patient with persisting right ventricular sinusoids

ASE Guidelines on Aortic Regurgitation What Do I Measure? Case Studies

Realistic simulation in Point of Care Ultrasound & Echocardiography

Confident Diagnosis, Confident Decisions

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

XII ECHOCARDIOGRAPHY COURSE FOR EMERGENCY MEDICINE, INTENSIVE CARE, OPERATING ROOMS AND RESUSCITATION

Intuitive. Intelligent. Innovative. General Imaging

Transcription:

Whitepaper Automated Image Biometrics Speeds Ultrasound Workflow ACUSON SC2000 Volume Imaging Ultrasound System S. Kevin Zhou, Ph.D. Siemens Corporate Research Princeton, New Jersey USA Answers for life.

Page 1 Automated Image Biometrics Speeds Ultrasound Workflow June 2008 Automated Image Biometrics Speeds Ultrasound Workflow The following text reviews measurement consistency and reproducibility challenges within echocardiography. Past techniques used in automated measurements methods are discussed. An innovative, new method based on learned pattern recognition is proposed with workflow benefits. Introduction Cardiac biometrics are routinely measured from echocardiograms to provide quantitative analysis of the human heart. For example, M-mode measurements of left and right ventricular dimensions and wall thicknesses are extracted at diastole and systole. Measurements are also made of the aortic valve, aortic root, and the left atrial dimension. From the 2D parasternal long axis or short axis view, measurements such as wall thickness and ventricle dimension are extracted. From Doppler data, pressure gradients and measurements of valve stenosis and regurgitation are extracted. Figure 1 shows several examples of cardiac biometrics that are measured in a standard echocardiogram. Figure 1a. M-mode echocardiogram Figure 1b. B-mode echocardiogram Varying skill levels among echocardiographers and sonographers plus the wide range of image quality across patient exams add complexity and measurement variability. This individualized reading of an ultrasound image can unavoidably lead to significant inter-user and intra-user variation in the final measurements. Consistent and reproducible measurements performed with speed and fidelity are key challenges to advancing the practice of echocardiography. Siemens Corporate Research (SCR) has developed a fundamentally novel innovation based on a learned pattern recognition technology to deliver measurement reproducibility and to accelerate workflow. This methodology, which is theoretically designed to be probabilistic, hierarchical, and discriminant (PHD), enables automatic, consistent, rapid and accurate measurements of cardiac biometrics. The PHD detection technology will be elaborated later in this discussion. Figure 1c. Doppler echocardiogram; LVOT Figure 1d. Doppler echocardiogram; aortic regurgitation

Page 2 Whitepaper ACUSON SC2000 Volume Imaging Ultrasound System June 2008 Annotated Database Learned pattern recognition technology is based on a broad subfield of artificial intelligence called machine learning. Learned pattern recognition methods revolve around designing and developing algorithms and techniques that enable computers to learn, e.g., to extract information from data automatically via computational and statistical methods. Learning is derived from a large series of manually identified measurements. This learning capability distinguishes Siemens approach from previous attempts in automated quantification of cardiac biometrics. Alternate techniques for automated measurements outside learned pattern recognition have leveraged image processing techniques such as edge detection and nonlinear image filtering. These techniques work well for images of good quality, but are prone to failures when dealing with noisy images. In general, these techniques are generic and hence applicable to other applications while learned pattern recognition is customized for the specific measurements within cardiac ultrasound. SCR collected a large database of over 1000 full exams, from which M-mode, 2D, and Doppler images were used for learning purposes. The selected images represent patients with pathologies commonly seen in clinical cardiology practices. Each of the images has been meticulously measured by placing identifying landmarks by one or more clinical experts before being fed into the learning engine. Different annotations based on landmarks and deformable parametric contours have been progressively designed. A deformable parametric contour can be defined by connecting a cohort of landmarks or using other parametric representations. Figure 2 illustrates how an annotated dataset of an M-mode echo is formed. Figure 2. Representative database of M-mode echocardiograms in normal and abnormal studies. (a) Image samples extracted from the original raw M-mode echocardiograms measuring M-mode LV dimensions at diastole. Five individual landmarks are identified. (b) The image samples are then normalized based on their identifiers. Figure 2a. Figure 2b.

Page 3 Automated Image Biometrics Speeds Ultrasound Workflow June 2008 Root detector with mode selection Box detector with mode selection Warping detector with post processing Figure 3. A pictorial illustration of applying the PHD framework for detecting curves in a tricuspid regurgitation image example. The PHD Framework for Deformable Structure Detection Automatic detection of deformable structures (i.e. cardiac tissues) is a precursor to deriving the cardiac biometrics, accomplished using a framework that is probabilistic, hierarchical, and discriminant (PHD). The basic detection principle is to learn a discriminant binary classifier which separates the deformable pattern of interest (the positive) from the remaining (the negative). Since deformable structure lies in a high-dimensional parameter space, an exhaustive search in this space for the optimal parameter is computationally prohibitive. Figure 3 illustrates how the PHD detection framework is used for detecting curves in a tricuspid regurgitation image example. First, the left and right root detectors are applied to detect the left and right roots. Second, the box detector is applied to detect the rigid box that bounds the structure. Finally, a warping detector that is trained based on perfectly warped examples is applied to detect the deformable structure. Instead of attempting to learn one super classifier, a series of binary classifiers are identified then arranged into a progressive hierarchy. To build a detector hierarchy that supports fast evaluation, simple models are progressively built into more complex computational models. The overall detection probability is then propagated throughout the hierarchy. Further details of the PHD framework can be found from other sources. 1, 2

Page 4 Whitepaper ACUSON SC2000 Volume Imaging Ultrasound System June 2008 Measurement User, Manual (one cardiac cycle) Computer, Auto M-mode LV 20 25 sec Less than 1 sec B-mode LV (ES/ED) 24 30 sec Less than 3 sec PW Doppler LVOT VTI 14 20 sec Less than 1 sec CW Doppler AoR Deceleration Time 4 8 sec Less than 1 sec Table 1. Speed comparison between manual and automatic annotation. Automated Quantification and Speed Improvement Once the structures are detected, e.g. cohorts of landmarks are detected from M-mode and 2D echocardiograms and the deformable parameterized curves from Doppler echocardiograms, quantification parameters can be calculated. If multiple heart rates are present and fused together, robust measurements of cardiac biometrics can be derived. The automatic algorithm frees the need for manual measurements previously required for extracting biometrics. Automation running speed is fast. Table 1 compares the time needed for an average user and the computer to perform typical biometric measurements. Conclusions Siemens has addressed the measurement consistency and reproducibility challenges in routine echocardiographic studies by leveraging clinical insights from experienced experts to design an innovative solution that enables automatic measuring of cardiac biometrics. This solution is based on learned pattern recognition technology which builds a model of the target deformable structure by extracting knowledge from an annotated database of over 1000 exams, covering a wide spectrum of patients and pathological cases. The PHD detection framework is carefully designed to allow the detection of deformable structures with high precision and speed. Automated biometrics show time savings over manual measurements and can improve exam efficiencies. References 1. Zhou SK, Guo F, Park JH, Carneiro G, Jackson J, Brendel M, Simopoulos C, Otsuki J, Comaniciu D. A probabilistic, hierarchical, and discriminant (PHD) framework for rapid and accurate detection of deformable anatomic structure. IEEE International Conference on Computer Vision. Rio de Janeiro, October 2007. 2. Zhang J, Zhou S, McMillan L, Comaniciu D. Joint real-time object detection and pose estimation using probabilistic boosting network. IEEE Computer Society Conference on Computer Vision and Pattern Recognition. Minneapolis, Minnesota. June 2007.

Standalone clinical images may have been cropped to better visualize pathology. ACUSON and SC2000 are trademarks of Siemens Medical Solutions, Inc. 06.2008, Siemens Medical Solutions USA, Inc. DS 0608 Contacts Europe: +49 9131 84-0 Asia Pacific: +65 6341-0990 Latin America: +1-786-845-0697 USA Siemens Medical Solutions USA, Inc. Ultrasound Division 1230 Shorebird Way P.O. Box 7393 Mountain View, CA 94039-7393 USA Telephone: +1-888-826-9702 Headquarters Siemens Medical Solutions USA, Inc. 51 Valley Stream Parkway Malvern, PA 19355-1406 USA Telephone: +1-888-826-9702 www.usa.siemens.com/healthcare www.siemens.com/healthcare