Quantitative Computed Tomography 4 Introduction

Similar documents
9 Quality Assurance in Bone Densitometry section

THE DIAGNOSIS OF OSTEOPOROSIS BY MEASURING LUMBAR VERTEBRAE DENSITY WITH MDCT: A COMPARATIVE STUDY WITH QUANTITATIVE COMPUTERIZED TOMOGRAPHY (QCT)

QCT and CT applications in Osteoporosis Imaging

2013 ISCD Official Positions Adult

pqct Measurement of Bone Parameters in Young Children

Documentation, Codebook, and Frequencies

Accuracy of DEXA scanning & other methods for determining BMD.

QCT BMD Imaging vs DEXA BMD Imaging

L.W. Sun 1,2, G. Beller 1, D. Felsenberg 1. Introduction. Original Article. Abstract

CLINIQCT NO-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE.

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p.

Clinical Study Comparison of QCT and DXA: Osteoporosis Detection Rates in Postmenopausal Women

Bone Densitometry Radiation dose: what you need to know

Volumetric Quantitative CT of the Spine and Hip Derived from Contrast-Enhanced MDCT: Conversion Factors

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry

2013 ISCD Combined Official Positions

Bone Densities and Bone Size at the Distal Radius in Healthy Children and Adolescents: A Study Using Peripheral Quantitative Computed Tomography

A basic study for automatic recognition of osteoporosis using abdominal X-ray CT images

Interpreting DEXA Scan and. the New Fracture Risk. Assessment. Algorithm

Bone mineral density in steroid-dependent asthma assessed by peripheral quantitative computed tomography

Journal of Bone and Mineral Research 12: , Non-Invasive Bone Mass Measurement: Techniques and Applications

CT Imaging of skeleton in small animals. Massimo Marenzana

Thickness Computation Under In-Vivo Trabecular Bone CT Imaging

DXA When to order? How to interpret? Dr Nikhil Tandon Department of Endocrinology and Metabolism All India Institute of Medical Sciences New Delhi

Assessment of Bone Mineral Density of Patient s with Thyroid Disorder using Computed Tomography

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2017

Norland Densitometry A Tradition of Excellence

Omnisense: At Least As Good As DXA

New Dual-energy X-ray Absorptiometry Machines (idxa) and Vertebral Fracture Assessment

Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?

LUMBAR IS IT IMPORTANT? S. Tantawy,, M.D.

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

Bone Densitometry. Total 30 Maximum CE 14. DXA Scanning (10) 7

LOW-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE

Bone Investigational Toolkit BIT. Biomechanical Bone Integrity Assessment

The Bone Densitometry Examination

S. N. Khan 1, R. M. Warkhedkar 2, A. Shyam 3, B. R. Patil 4

Scattered image artifacts from cone beam computed tomography and its clinical potential in bone mineral density estimation

Osteoporosis International. Original Article. Bone Mineral Density and Vertebral Fractures in Men

Advance in Knowledge This study provides normative reference values for vertebral trabecular bone density obtained by using quantitative CT in healthy

2 Skeletal Anatomy in Densitometry

Mineral Density Of Subchondral Bone May Be Quantitatively Evaluated Using A Clinical Cone Beam Computed Tomography Scanner

Use of DXA / Bone Density in the Care of Your Patients. Brenda Lee Holbert, M.D. Associate Professor Senior Staff Radiologist

This is a repository copy of Microarchitecture of bone predicts fractures in older women.

Trabecular bone analysis with tomosynthesis in diabetic patients: comparison with CT-based finite-element method

Identification of Early Osteoporosis Using Intensity Slicing method

Objectives. Discuss bone health and the consequences of osteoporosis on patients medical and disability status.

Comparison of Bone Density of Distal Radius With Hip and Spine Using DXA

Healthy aging. It s vital.

3 - D i m e n s i o n a l V o l u m e t r i c Q C T B o n e D e n s i t o m e t r y o f t h e H i p a n d S p i n e

Microstructural changes in the bone tissue and in the bone callus of diabetic rats with and without insulin treatment

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE DEPARTMENT OF SCIENCE

Densitometry Techniques

Peripheral Quantitative CT (pqct) Using a Dedicated Extremity Cone-Beam CT Scanner

Peripheral quantitative computed tomography of the distal radius in young subjects new reference data and interpretation of results

Metal Artifact Reduction by Dual Energy CT

Standard Operating Procedure TCRC Dual-Energy X-ray Absorptiometry (DXA)

Comparison of Muscle Image Acquisition & Analysis Techniques

Validation of in vivo cancellous bone assessment using high resolution imaging and histologic examination

DXA IS THE MOST commonly used method of assessing

The DXL Calscan heel densitometer: evaluation and diagnostic thresholds

Annotations Part III Vertebral Fracture Initiative. International Osteoporosis Foundation March 2011

PhenX Measure: Body Composition (#020300) PhenX Protocol: Body Composition - Body Composition by Dual-Energy X-Ray Absorptiometry (#020302)

Automated simulation of areal bone mineral density assessment in the distal radius from high-resolution peripheral quantitative computed tomography

Imaging to Assess Bone Strength and its Determinants

Advanced Point-of-Care Bone Health Assessment HOLOGIC OSTEOPOROSIS ASSESSMENT

Bone Densitometry Equipment Operator

The relationship between Computed Tomography and DXA results: A potential bias in Bone Mineral Density assessment

Bone Mineral Density Studies in Adult Populations

Adina Alazraki, MD, FAAP Assistant Professor, Radiology and Pediatrics Emory University School of Medicine Children s Healthcare of Atlanta

Least significant changes and monitoring time intervals for high-resolution pqct-derived bone outcomes in postmenopausal women

Building Bone Density-Research Issues

The effect of vertebral rotation of the lumbar spine on dual energy X-ray absorptiometry measurements: observational study

Measurement Uncertainty in Spine Bone Mineral Density by Dual Energy X-ray Absorptiometry

Quality Control of DXA System and Precision Test of Radio-technologists

Bone Densitometry. What is a Bone Density Scan (DXA)? What are some common uses of the procedure?

Quality Assurance and Control in Dual energy X ray Absorptiometry

SPR 2017 General Pediatric Radiology Categorical Course: Musculoskeletal May 16, 2017 SAM References

Bone density and size in ambulatory children with cerebral palsy

DEXA Scores and Bone Density Measured on Routine CT Scans

ADOLESCENT OBESITY: IS IT BAD FOR THE BONES

Preliminary technical data

Dual-energy Vertebral Assessment

The bone mass concept: problems in short stature

Nutritional Aspects of Osteoporosis Care and Treatment Cynthia Smith, FNP-BC, RN, MSN, CCD Pars Osteoporosis Clinic, Belpre, Ohio

Silvia Capuani*, Giulia Di Pietro*, Guglielmo Manenti, Umberto Tarantino^

DXA Best Practices. What is the problem? 9/29/2017. BMD Predicts Fracture Risk. Dual-energy X-ray Absorptiometry: DXA

ReviewArticle. Frequently Asked Questions About Bone Mineral Density Test

Prodigy. from GE Healthcare. Most trusted, reliable and best-selling DXA system with one of the largest installed base in the world. gehealthcare.

Selecting regions of interest on intra oral radiographs. for the prediction of bone mineral density

chapter Bone Density (Densitometry) RADIOPHARMACY INDICATIONS Radionuclide Localization Quality Control Adult Dose Range Method of Administration

Effect of Precision Error on T-scores and the Diagnostic Classification of Bone Status

Clinical Densitometry

Certified Clinical Densitometrist (CCD ) DXA Resource Materials

Product: Denosumab (AMG 162) Clinical Study Report: month Primary Analysis Date: 21 November 2016 Page 1

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Diagnostische Präzision von DXL im Vergleich zu DXA bei pmp Frauen mit Frakturen

JBMR. Osteoporotic fracture is a global public health concern

Automated measurement method of bone mineral density of vertebral bones and spinal curvature using sagittal plane in X-ray torso CT images

Opportunistic screening for osteoporosis on routine computed tomography? An external validation study

Transcription:

Quantitative Computed Tomography 4 Introduction Quantitative Computed Tomography (QCT) is a well recognised technique for the measurement of bone mineral density (BMD) in the lumbar spine1 and forearm2. This technique is the only BMD measurement method to provide, firstly, a true volumetric measurement of bone density in mg/cm3 and secondly, a separate measurement of trabecular and cortical bone density. The latter is due to the difference in computer tomography(ct) attenuation values, expressed in Hounsfield Units (HU), of trabecular and cortical bone. This enables the outer cortical rim with a higher attenuation value to be clearly separated from the inner lower attenuated trabecular bone on the cross-sectional CT image. Trabecular bone has a higher turnover than cortical bone due to its greater surface area and this makes QCT a very useful technique to monitor bone turnover and the efficacy of treatment3. QCT measurements have been used to assess vertebral fracture risk4 and has been found to be a superior technique against other BMD measurement methods for assessing age-related bone loss, discriminating fracture and diagnostic classification5. Recent developments in CT, such as spiral, has allowed three-dimensional(3-d) volumetric BMD analysis of the proximal femur and the investigation of trabecular structure is now possible with high resolution CT scanning together with texture analysis6.

Spinal QCT Measurement Technique Spinal QCT measurements are performed on standard clinical CT scanners with the assistance of specially designed QCT software packages making it readily available around the world. This technique consists of a measurement of trabecular BMD in a number of consecutive vertebrae, usually between T12 to L47. The patient is scanned lying supine on a QCT bone mineral density calibration phantom. From a lateral scanogram or scoutview of the lumbar spine(fig 1), the mid plane of the relevant vertebral bodies are selected. Figure 1 Lateral scanogram of the lumbar spine used to localise the position of the mid-vertebral slices (L2-4) for the QCT scans. The automated software has been used. Using a low kv technique, single 8-10 mm slices are taken through the selected vertebrae (Fig 2a). The scanner gantry is angled for each vertebral slice so that slice plane bisects the vertebral body in the midplane and is parallel to the end plates. In the case of a fractured vertebra, a slightly narrower slice thickness (eg 5 mm) may be required so that the end plates are not included. With their inclusion the BMD will be artificially raised and in the case of a marked reduction in vertebral height, the vertebra should be excluded from the measurement. Figure 2a Cross-sectional QCT image of the lumbar spine showing the automated QCT software defining cortical and trabecular bone in the vertebral body. The patient is laying on the Siemens solid state QCT bone mineral phantom For the BMD calculation, a region of interest (ROI) is positioned either manually or with the aid of specially designed QCT software 8 within the trabecular portion of the vertebral body. This region may encompass all the trabecular bone 9 or be oval, circular or pacman in shape dependant upon the technique chosen 10. The BMD is then calculated by converting the CT attenuation value of the trabecular ROI (where air = -1000 HU, water = 0 HU and cortical bone = up to +1000 HU) into bone mineral equivalent using the ROI s representing bone and water within the calibration phantom. The vertebral densities are averaged to

provide a mean BMD for the patient under examination. The result can then be plotted against a normal age and sex-matched range for the population (Fig 2b). Spinal QCT normative data ranges are available for both adults 11 and children 12. The cortical rim of each vertebral body can also be defined and a cortical BMD calculated as well as an integral BMD (cortical and trabecular BMD) for the patient. Figure 2b With the low kv QCT technique (80 kv), the effective dose of radiation to the patient is 60 μsv. The examination time is approximately 10-15 minutes depending upon the technique and software used. The in vivo precision and accuracy of this technique is 2-4% and 4-15% respectively 7. Short and long-term QCT precision together with examination time has been improved by the use of specially designed software that automatically selects the mid slice level from the lateral scoutview, defines the ROI s on the axial slices, calculates the BMD level and plots the result on a graph showing the normal range. 8 This software also helps to reduce operator induced variations that may affect the precision of the technique when it is performed manually. Software is now available from a number of companies (Image Analysis Inc; USA and Mindways Software Inc; USA) enabling off line evaluation of QCT data thus reducing CT machine time and increasing patient throughput. Spinal QCT Calibration Phantoms The use of a calibration phantom provides a consistent bone equivalent standard and compensates for any alteration in CT attenuation values. The latter can be caused by changes in beam hardening due to the different sizes and shapes of patients under examination and the variation in scanner stability due to scanner external current alterations. Any alteration in attenuation values is not relevant to the normal clinical CT image but has major importance when the scan attenuation information is to be used to quantify absolute values and change such as in QCT measurements. A variety of calibration phantoms have been developed. The first was a liquid calibration phantom developed by the pioneers of QCT measurements, Cann and Genant at the University of California, San Francisco 1. The phantom is made of plexiglass and contains a number of liquid insets representing water, fat and three different concentrations of dipotassium hydrogen phosphate (K 2 HPO 4 ) representing three levels of bone mineral equivalent (50, 100 and 200 mg/cm 3 ). This phantom has been used in many centres around

the world, but its long-term stability was found to be limited and therefore solid state phantoms are now in general use (Fig 2a). They contain a solid water equivalent compound together with calcium hydroxyapatite for the bone equivalent. Advantages of QCT Technique QCT provides a measurement of the metabolically more active trabecular bone where as Dual Energy X-ray Absorptiometry (DXA) produces a measurement of the less active integral bone making QCT measurements more sensitive to change. Postero-anterior DXA measurements of the lumbar spine may be artifactually increased because of the presence of extraneous calcification (eg aortic) and degenerative disease in the field of interest13. In QCT, this problem is not encountered because of the axial slice and the selected ROI making the measurement more accurate. The presence of lumbar fractures may also increase the DXA measurement and this can be avoided by the QCT midplane slice which does not include the sclerotic endplates in the measurement. With centres who have access to CT scanners, the cost of a QCT measurement can be considerably less than DXA scan because the purchase of the QCT software is considerably less than the capital outlay for DXA equipment together with extra staff and the cost of a new examination room. Peripheral QCT (pqct) Measurement Technique Peripheral QCT (pqct) measurements are performed on specially designed small gantry CT scanners using a translate-rotate movement with a multi-detector head (Fig 3). As with spinal QCT, a separate measurement of cortical and trabecular bone is obtained but in peripheral regions of the body such as the forearm, femur, tibia and in the mandible. Measurements of BMD and bone mineral content (BMC) together with an axial crosssectional area of the bones concerned can be calculated14. The original scanners used an I- 125 source2 but the current pqct commercial scanners (Stratec Electronic GmbH, Germany and Scanco Medical, Switzerland) use an X-ray source. There are now over a 1,000 pqct scanners in use, mainly within Europe. The majority of the systems are in clinical use but a small number using multi-slice, ultra-high resolution, high precision techniques can be found in research settings. In clinical pqct scanners, a single axial CT slice, 2.5 mm in thickness, is taken through the distal radius and ulna at the level which represents 4% of the ulnar length from its distal end(fig 4). Like the spinal QCT technique, a scout view is used to position the axial scan plane. Examination time is short and the effective equivalent dose of radiation to the patient is 6 μsv. On follow-up scans, the software automatically repositions the axial slice plane to the same level as the baseline scan improving precision. The software automatically defines the cortical and trabecular ROI s within the radius and the BMD is calculated using

threshold algorithms and iterative contour detection methods. Normative European data is available for forearm pqct measurements16 and the Stratec machines are calibrated against the European Forearm Phantom. The in-vivo precision (CV%) for pqct of the forearm is 0.5-2.1% with in-vitro accuracy of around 2%17. Figure 4 pqct images of the forearm, showing the reference scanogram on the right and the axial slice of the radius. The patient s total density and trabecular density are printed on separate graphs of the BMD versus age. The normative data range is shown on the graph. Cross-Calibration of QCT and pqct Scanners The European Spine Phantom (ESP)18 and the European Forearm Phantom (EFP)19 were developed with funding from the EEC for the COMAC-BME project. The ESP phantom provides cross-calibration between QCT and DXA equipment for spinal BMD measurements and the EFP is used for forearm measurement cross-calibration between pqct and peripheral DXA (pdxa) equipment. The composition of these phantoms together with their use will be discussed in the later section of this report dealing with Quality Assurance of Bone Densitometers. Future Developments in QCT Measurements Volumetric QCT With the development of split-ring technology, low kv spiral CT allows volumetric scans of the lumbar spine and hip. Reformatted axial slices using any slice thickness (normally 4 10 mm) and 3-D images can be produced from these volumetric data sets (Mindways Software Inc, USA). In the spine, more representative mid plane slices may be created so that vertebral endplates can be excluded from the measurement. Using Mindways software, bone mineral density measurements of the proximal hip can be produced from reformatted CT images. The regions are very similar to those measured by DXA i.e. the femoral neck, Ward s triangle, trochanter and total hip and the results can be normalised to the NHANES hip database. Volumetric bone density measurements in mg/cm 3 of the cortical and trabecular components of the hip can also be expressed. QCT measurements of the hip20 have not been generally performed in the past because of the high radiation dose to the patient and the hip s complex architecture. With low dose volumetric scanning and this specially designed software, the viability of examining this region of the skeleton may change in the future.

High Resolution QCT Micro structural analysis of trabecular bone may assist in the prediction of future fracture risk and high resolution QCT provides information on the bony architecture of the region of interest. This technique requires thin slice high resolution computer tomography together with complicated processing techniques. Currently this work is only being performed in the research setting on bone specimens and the peripheral skeleton but it provides important information on bone structure and strength but could possibly be extended to the clinical setting. Summary QCT bone density measurements of the lumbar spine can be performed on standard clinical CT scanners with the assistance of specialist software and pqct measurements on specially designed small bore CT scanners. The measurements are accurate and precise using a comparatively low dose of radiation in comparison with a diagnostic CT procedure. A volumetric measurement is provided separately of trabecular and cortical BMD. The former being the most sensitive to metabolic and age related changes. In the spine and especially in the older population, QCT may provide a more accurate BMD measurement than DXA because it avoids the effects of degenerative disease and extraneous calcification. References 1. Cann CE, Genant HK. Precise measurement of vertebral mineral content using computed tomography. J Comput Assist Tomogr 1980;4:493-500. 2. Rüegsegger P, Elasser U, Anliker M, Gnehm H, Kind H, Prader A. Quantification of bone mineralization using computed tomography. Radiology 1976;121:93-97. 3. MacIntyre I, Stevenson JC, Whitehead MI, Wimilawansa SJ, Banks LM, Healy M. Calcitonin for prevention of post-menopausal bone loss. Lancet 1988;8591:900-902. 4. Pacifici R, Rupich R, Griffin M, Chines A, Susman N, Avioli LV. Dual energy radiography versus quantitative computed tomography for the diagnosis of osteoporosis. J Clin Endocrinol Metab 1990;70:705-710. 5. Grampp S, Genant HK, Mathur A, Lang P, Jergas M, Takada M et al. Comparisons of noninvasive bone mineral measurements in assessing age-related loss, fracture discrimination and diagnostic classification. J Bone Miner Res 1997;12:697-711. 6. Guglielmi G, Schneider P, Giannatempo GM, Cammisa M, Genant HK. Quantitative computed tomography at the axial and peripheral skeleton. Eur Radiol 1997;7(Suppl.2):S32-S42. 7. Cann CE. Quantitative CT for determination of bone mineral density: a review. Radiology 1988;166:509-522. 8. Kalender WA, Bretowsky H, Felsenberg D. Bone mineral measurements: automated determination of the midvertebral CT section. Radiology 1988;168:219-221. 9. Banks LM, Stevenson JC. Modified method of spinal computed tomography for trabecular bone mineral measurements. J Comput Assist Tomogr 1986;10:463-467. 10. Steiger P, Block JE, Steiger S, Heuck A, Friedlander A, Ettinger B et al. Spinal bone mineral density by computed tomography: effect of region of interest, vertebral level and technique. Radiology 1990;175:537-543. 11. Kalender W, Felsenberg D, Louis O, Lopez P, Klotz E, Osteaux M et al. Reference values for trabecular and cortical vertebral bone density in single and dual-energy quantitative computed tomography. Eur J Radiol 1989;9:75-80. 12. Gilsanz V, Gibbens DT, Roe TF, Carlson M, Senac MO, Boechat MI et al. Vertebral bone density in children: effect of puberty. Radiology 1988;166:847-850. 13. Banks LM, Lees B, MacSweeney JE, Stevenson JC. Effect of degenerative spinal and aortic calcification on bone density measurements in post-menopausal women: links between osteoporosis and cardiovascular disease? Eur J Clin Invest 1994;24:813-7. 14. Wapniarz M, Lehmann R, Reincke M, Schönau E, Klein K, Allolio B. Determinants of radial bone density as measured by pqct in pre and postmenopausal women: the role of bone size. J Bone Miner Res 1997;12:248-254. 15. Reeve J, Kröger H, Nijs J, Pearson J, Felsenberg D, Reiners C et al. Radial cortical and trabecular bone densities standardized with the European Forearm Phantom. Calcif Tissue Int 1996;58:135-143. 16. Grampp S, Lang P, Jergas M, Glüer C-C, Mathur A, Engelke K et al. Assessment of the skeletal status by quantitative peripheral computed tomography: short-term precision in-vivo and comparison to dual X-ray absorptiometry. J Bone Miner Res 1995;10:1566-1576. 17. Kalender WA, Felsenberg D, Genant HK, Fischer M, Dequecker J, Reeve J. The European Spine Phantom - a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT. Eur J Radiol 1995;20:83-92. 18. Rüegsegger P, Kalender W. A phantom for standardization and quality control in peripheral bone measurements by pqct and DXA. Phys Med Biol 1993;38:1963-1970. 19. Heitz M, Kalender W. Evaluation of femoral density and strength using volumetric CT and anatomical coordinate systems. Bone 1994;25:S11. 20. Link TM, Majumdar S, Lin JC, Newitt D, Augat P, Ouyang X et al. A comparative study of trabecular bone properties in the spine and femur using high resolution MRI and CT. J Bone Miner Res 1998;13:122-132.