Fibertec 1023 Dietary Fibre Solutions

Similar documents
TECHNICAL BULLETIN METHOD 1: DETERMINATION OF TOTAL DIETARY FIBRE

MilkoScan FT1. Milk standardisation with in-built abnormality screening. Dedicated Analytical Solutions

CyBio Felix Your Automated Application Starts Here

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

Solutions at GE Inspection Technologies

Routine analysis for fish farming and processing

Food Proficiency Testing Program Round 38 Wheat Flour

BÜCHI Hydrolysis Unit B-411 BÜCHI Extraction System B-811

Hydrolysis Unit B-411 / E-416 Technical data sheet

Ultrasonic Condition Monitoring MORE THAN JUST A LEAK DETECTOR

ISO IDF 20-5 INTERNATIONAL STANDARD. Milk Determination of nitrogen content Part 5: Determination of protein-nitrogen content

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

TOTAL DIETARY FIBRE ASSAY PROCEDURE. (200 Assays per Kit)

OUTLINE. ILVO Introduction Determination of HP Validation of method Conclusion

Division of Dockets Management (HFA-305) Food and Drug Administration 5630 Fishers Lane, Rm Rockville, MD 20852

Innovations for a better world. Mixing plants. For premix and ready mix formulas.

NEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER. Rapid and reliable diagnosis of Helicobacter pylori infections

Tropic plus ultrasonic nebulizer Consumables and Accessories

Application Note No. 108/2013 Nitrogen & protein determination in beer and malt KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Nitrogen

Retrofit & Monitoring

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

MilkoScan FT+ for routine compositional raw milk analysis

CORESTA RECOMMENDED METHOD N 39

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

Purpose of Proximate Analysis

Savesta Herbals is engaged in manufacturing

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

the minispec mq series TD-NMR Analyzers Innovation with Integrity TD-NMR TD-NMR General Principles the minispec International Standard Methods

Auto HbA1C ANALYZER HbA1LC HPLC 3660

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

Application Note No. 110/2013 Nitrogen & protein determination in corn, flour and soy KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

How-To Evaluate a Veterinary Digital Radiography System A SPECIAL REPORT

CAD/CAM TECHNOLOGY. DC7 Milling System

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

High protein content determination in food and animal feed by combustion using the Thermo Scientific FlashSmart Elemental Analyzer

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

Purity Tests for Modified Starches

Macromolecules Materials

LACTOSE/ SUCROSE/D-GLUCOSE

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

LC-LC-GC-MS System PAH PAH Workstation

Artificial Neural Networks and Near Infrared Spectroscopy - A case study on protein content in whole wheat grain

Application Note No. 113/2013 Nitrogen & protein determination in dry pet food KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

LAP-003CS. Procedure Title: Author(s): Bonnie Hames, Fannie Posey-Eddy, Chris Roth, Ray Ruiz, Amie Sluiter, David Templeton.

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Material Safety Data Sheet

ISO IDF INTERNATIONAL STANDARD

The Cannabis Workflow and the IMPORTANCE OF TEMPERATURE CONTROL

Low-Pressure Chromium Speciation in P2O5 using the Spectro ARCOS MV ICP and the ESI SC-DX chromfast System

What is Dietary Fiber and how do you select the appropriate method?

DÜRR X-RAY FILM PROCESSING. The development goes on and on DÜRR XR 24 PRO

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

8. Maring Fag Dag. - Using marine offcuts to penetrate the high value nutrition market. 29. November 2012

NORTHERN CORRIDORSTANDARD NC 4:2018. Roasted Macadamia Specification

Glucose analyser GA 3

SUCCESS STORY. Bürkert < > Novo Nordisk A new formulation line for insulin vials

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

DRAFT EAST AFRICAN STANDARD

Agilent 1220 Infinity LC System Performance Specifications

Soymilk Processing and Cereal Drinks. GEA centrifuges are the first choice

Custom instruments. Insio primax User Guide. Hearing Systems

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

Rat Hemoglobin A1c (HbA1c) Kit Instructions

powerful versatile mobile

esthetic.line The lithium disilicate press ceramic system. Soprano 10 Livento press

Puls 2.0 Radial Pulse Therapy

Organic Molecule Composition of Milk: Lab Investigation

Dry Injection of Sodium Sorbents - Effects of Using Mills

AK 200 S AK 200 ULTRA S. A better way to better care

ELECTRONIC PIPETTE. The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE

Application Note No. 201/2015 Nitrogen & protein determination in starch and gluten KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376 and

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Fat Content Determination Methods Teresa McConville Chem 311 Dr. Weisshaar

NRT - for more than 25 years providing medical x-ray solutions. Diagnostic excellence... nrt celex brochure 05/03/03 10:25 Side 1

STUDIES ON HEMOGLOBIN. III An Ultra-Micro-method for the Determination of Hemoglobin as a Peroxidase.

Measuring detergent fibre and insoluble protein in corn silage using crucibles or filter bags

Application Note No. 112/2013 Nitrogen & urea determination in cosmetics KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Nitrogen and

Gentian Canine CRP Immunoassay Application Note for scil VitroVet*

Nutritional information

ÜBERCLEAN! Introducing the new STATMATIC PLUS.

Low Row. User manual E S S E N T I A L S T R E N G T H

Simple. Stress-free. The Newtron Ultrasonics Series

Capturing lightning In A Bottle

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610

WITH REGARD TO METHODS OF ANALYSIS FOR DETERMINATION OF THE FIBRE CONTENT DECLARED ON A LABEL

Expert support to create cost-effective dairy taste and texture

Determination of available nutrients in soil using the Agilent 4200 MP-AES

ABIOpure TM Viral (version 2.0)

EASIMIP TM PATULIN Product Code: P250 / P250B

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

Name: Date FOD1060 started: Date FOD1060 completed: Final Mark FOD1060: 1 Credit Submitted:

Skin Grafting Family. The Power of Precision

Pelagia Research Library

SENSATION and CS300 Smaller meets faster. IABP System

Unit J: Adjusting Standardized Recipes

ER75 Electro-Acoustic Ear Simulator. Operating Manual

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

Transcription:

Fibertec 1023 Dietary Fibre Solutions Tecator Line The Fibertec 1023 Dietary Fibre Analysis System is a semi-automated incubation and filtration system for quantitative determination of dietary fibre in processed food, cereal products, fruits and vegetables, health food, plant materials etc., using established enzymatic methods, for use in the laboratory. Sample Food and Food Ingredients Parameters Total, soluble and insoluble dietary fibre Dedicated Analytical Solutions

Rapid Dietary Fibre analysis The Fibertec 1023 is designed for rapid and rational determination of dietary fibre according to established enzymatic methods, including those approved by AOAC, AACC, NMKL and Asp. The system includes a shaking water bath and a filtration module for quantitative determination of dietary fibre in a variety of sample types. The filtration module filters and collects six sample solutions and includes a system for rapid dehydration. The filtration step is speeded up through a built-in Pressure Mode, to break up clogged filter residues during filtration. Filtration time varies from 2-4 minutes for 100 ml of digested solution. The WB 1024 Water bath incubates 12 samples in each batch. The temperature range is from ambient up to 80 C and it is possible to preset three temperatures. Batch handling processes up to 6 samples at a time saving time. Laboratories around the globe have invested in Fibertec instruments that go on working year after year, making Fibertec a solution that will keep your lab up to speed, well into the future. Effective laboratory operations The Fibertec 1023 takes fibre analysis to new levels of efficiency with facilities to match today s demands. The Fibertec systems handle samples in specially designed incubation flasks, along with a range of innovative features to make your laboratory operations even simpler: Rapid filtration of six samples simultaneously Specially designed incubation flasks High incubation and separation capacity Repeatable readings, S.D. < 0.5% absolute Easy and convenient to use Saves time, space and manual work Minimal downtime and service with long-life components Laboratory staff will be grateful for the reliability, ease of use and time-saving facilities that make everyday operations simpler and more convenient. APPLICATIONS Total Dietary Fibre (TDF) according to AOAC 991.43 and AACC 32-07 Soluble (SDF) and Insoluble (IDF) Dietary Fibre according to AOAC 991.42/43 and AACC 32-07 Total Dietary Fibre (TDF) according to AOAC 985.29 and AACC 32-05 Soluble (SDF) and Insoluble (IDF) Dietary Fibre according to AOAC 985.29 and AACC 32-05 A Total Dietary Fibre Enzyme Kit for 200 determinations (100 duplicate estimations) is available for above. Part Number 60046527 Integrated Total Dietary Fibre (ITDF) Codex Definition method according to AOAC 2009.01* *Note. The Fibertec system forms one part of the instrumentation required for the Integrated TDF method. Free choice of methods like AOAC, AACC, NMKL and Asp Determines total, soluble and insoluble dietary fibre 2

Semi-automated incubation and filtration system for quantitative determination of dietary fibre* in food, cereals, fruit and vegetables. *Note. A Boiling Water Bath, not supplied, is required for estimation of dietary fibre Technology The Fibertec 1023 determines total dietary fibre as well as the insoluble and soluble fibres separately. It is also useful in sample preparation for detailed studies of fibre fractions, e.g. by chromatographic or colorimetric techniques. The basic Fibertec 1023 includes a WB 1024 Water bath and a Filtration Module*. The WB 1024 Water bath incubates 12 samples in each batch. The temperature range is from ambient to 80 C and it is possible to preset three temperatures. The shaking frequency and amplitude are continuously adjustable. The Filtration Module filters and collects 6 sample solutions batch wise and includes a system for rapid dehydration. The filtration step is speeded up through built-in Pressure Mode. Reversed pressure is applied to facilitate filtration by breaking up clogged filter residues during filtration. Filtration time varies according to sample type, but on average it is 2-4 minutes for 100 ml of digested solution. The reproducibility (standard deviation) of the Fibertec 1023 in determining total, insoluble and soluble dietary fibre is < 0.5% absolute. *A Boiling Water Bath, not supplied, is required for estimation of dietary fibre 3

Secure your investment with a FossCare Support Agreement Let FOSS take care of you for a maximum return on your analytical investment. Get a four year warranty as part of the new FossCare Premium Preventive Maintenance Agreement or two years as part of any other FossCare agreement. In addition to the peace of mind afforded by the warranty period, the continual preventive maintenance pays off by keeping your analytical instruments working perfectly every day, year after year. Why preventive maintenance? Extended warranty on new instruments with a FossCare agreement As with any analytical solution, it is essential that your FOSS instrument receives regular maintenance to ensure optimal performance and extended lifetime. Avoiding expensive downtime is a matter of following factory standards and preventively replacing parts before they wear out. In turn, this helps ensure reliable and consistent results at the highest level. Preventive and predictive maintenance combined with global support from 300 dedicated service, application, software and calibration specialists keeps your instrument running perfectly all year round. YEAR WARRANTY with all FossCare Premium Preventive Maintenance Agreements Benefits of a FossCare TM Support Agreement: Extended Warranty (two or four years depending on the chosen agreement) Regular maintenance; the instrument is diagnosed, cleaned, adjusted, tested, fine tuned and recalibrated Minimal downtime from replacing components before they are worn out Consistent, accurate and reliable results you can always trust Preventative maintenance visits when it suits you (your business) 24/7 phone support - no need to worry about closing hours or PO Low, fixed service budget prevents unexpected expenses Discounts on additional services, spares, training, reagents, consumables and software upgrades Contact your local Foss office for more information. 4

Technical Specifications System description Fibertec 1023 Filtration Module complete, comprising: Filtration Module, Incubation Flasks (4 sets of 6), Standard Crucibles (P2, 2 sets of 6), Basket for Incubation Flasks, 2 Stands for Crucibles, 2 Spray bottles, 2 Water aspiration pumps, Filter aid, Tubing, WB 1024 Water bath, complete, comprising: a tray for 12 Incubation Flasks and a hinged inclined lid. Filtration module as above but without WB 1024 Water bath In addition, we recommend: Incubation Flask (set of 6), at least 4 sets Crucible, P2 (40-100 µm) set of 6, at least 2 sets Basket for 12 Incubation Flasks, at least 1 Total Dietary Fibre Kit for 200 determinations Note A Balance, Boiling water bath, Drying oven, Muffle furnace and Kjeldahl system are also required Accessories: Alternative filter crucibles: 1000 1174 Crucible, P0 (160-250 µm), set of 6 1000 1171 Crucible, P1 (90-150 µm), set of 6 1000 1173 Crucible, P3 (16-40 µm), set of 6 1000 1079 Stand for 6 Crucibles CT 193 Cyclotec Sample Mill CM 190 Cemotec Sample Mill KN 195 Knifetec Sample Mill for high fat, high fibre samples For protein determination we recommend our Kjeltec analyzers. Alternative flask trays for other applications, e.g. biochemical work: 1000 2203 Tray for E**-flasks, 50 ml 1000 2204 Tray for E**-flasks, 100 ml 1000 2205 Tray for E**-flasks, 250 ml 1000 2206 Tray for E**-flasks, 500 ml ** Erlenmeyer Performance data: Filtration Module: Filtration and dehydration capacity: Filtration rate: Repeatability: Flask volume: Accuracy: 6 samples/batch 2-4 minutes/100 ml of digested solution, depending on sample type S.D. < 0.5% absolute 600 ml According to official methods WB 1024 Water bath: Capacity: 12 flasks/batch Temperature range: ambient to 80 C Temperature accuracy: Shaking frequency: Stroke length: ± 0.1 C 0-150 strokes/minute 0-50 mm 5

Installation requirements: Equipment Power supply Power consumption Dimensions w d h Weight 1023 Filtration Module 210-230 V, 50-60 Hz 8 770 280 500 24 kg WB 1024 Water bath 210-230 V, 50-60 Hz 1.500 890 370 320 24 kg A complete analytical scheme for dietary fibre determination consists of: Samples with a low fat content CT 193 Cyclotec CM 190 Cemotec Samples with a high fat content HM 294/297 Homogeniser KN195 Knifetec Balance Water bath Boiling bath WB 1024 Water bath Filtration Module 1023 Drying Oven Balance Correction Muffle furnance Kjeldahl system FOSS Foss Allé 1 DK-3400 Hilleroed Denmark Tel.: +45 7010 3370 Fax: +45 7010 3371 info@foss.dk www.foss.dk P/N 1026663, Issue 2 GB, April 2014