DuraClone IM. Standardized phenotyping panels for studies of the human immune system

Similar documents
DURACLONE IF BE CERTAIN ABOUT THE RESPONSE. l res. a il n c n. For Research Use Only - Not for use in Diagnostic procedures

DURACLONE RE THERE ARE EVENTS YOU CANNOT AFFORD TO MISS

a Beckman Coulter Life Sciences: White Paper

BD Flow Cytometry Reagents Multicolor Panels Designed for Optimal Resolution with the BD LSRFortessa X-20 Cell Analyzer

Application Information Bulletin: Human NK Cells Phenotypic characterizing of human Natural Killer (NK) cell populations in peripheral blood

A step-by-step approach to build and analyze a multicolor panel

Fluorochrome Panel 1 Panel 2 Panel 3 Panel 4 Panel 5 CTLA-4 CTLA-4 CD15 CD3 FITC. Bio) PD-1 (MIH4, BD) ICOS (C398.4A, Biolegend) PD-L1 (MIH1, BD)

Naive, memory and regulatory T lymphocytes populations analysis

Phagocytosis of FITC labelled opsonized and non-opsonized E. coli bacteria by monocytes and granulocytes in a whole blood assay

Optimizing Intracellular Flow Cytometry

Comprehensive evaluation of human immune system reconstitution in NSG. and NSG -SGM3 mouse models toward the development of a novel ONCO-HU

FLOW CYTOMETRY PRINCIPLES AND PRACTICE. Toby Eyre Consultant Haematologist Oxford University Hospitals NHS Foundation Trust June 2018

PRIME-XV Dendritic Cell Maturation CDM

Optimizing Intracellular Flow Cytometry:

Supplementary Data. Treg phenotype

Measuring Dendritic Cells

Commercially available HLA Class II tetramers (Beckman Coulter) conjugated to

Supplemental Figure 1. IL-3 blockade with Fab CSL362 depletes plasmacytoid dendritic cells (pdcs), but not basophils, at higher doses.

CyTOF analyses in rheumatoid arthritis. Deepak Rao, MD PhD Rheumatology, Immunology, Allergy, BWH

Optimizing Intracellular Flow Cytometry:

Application Information Bulletin: Navios Multi-center Study

Clinical question. Screening tube. Diagnostic panel MRD. Clinical question

Supplementary Table e-1. Flow cytometry reagents and staining combinations

Fast and Easy Isolation of T Cells

MAIT cell function is modulated by PD-1 signaling in patients with active

Recommended Protocols for Phospho Protein Detection in Human Cells

AbSeq on the BD Rhapsody system: Exploration of single-cell gene regulation by simultaneous digital mrna and protein quantification

In vitro human regulatory T cell expansion

Application Information Bulletin: Cell Signaling

BD CBA on the BD Accuri C6: Bringing Multiplexed Cytokine Detection to the Benchtop

The spectrum of flow cytometry of the bone marrow

Standardization of whole blood immune phenotype monitoring for clinical trials: panels and methods from the ONE study

MHC Tetramers and Monomers for Immuno-Oncology and Autoimmunity Drug Discovery

VUmc Basispresentatie

CHAPTER 3 LABORATORY PROCEDURES

B and T-Cells. CD8+ Cytotoxic T Cells

In vitro human regulatory T cell expansion

Emerging Concepts of Cancer Immunotherapy

Question 1. Kupffer cells, microglial cells and osteoclasts are all examples of what type of immune system cell?

MACS Cell Pre-Enrichment for flow sorting and analysis

CLINICAL USE OF CELLULAR SUBPOPULATION ANALYSIS IN BM

Supplementary Fig. 1: Ex vivo tetramer enrichment with anti-c-myc beads

IMMUNOLOGY. Source, Isolate, Culture, And Analyze Immune Cells. Scientists Helping Scientists

Human Innate Lymphoid Cells: crosstalk with CD4 + regulatory T cells and role in Type 1 Diabetes

Muse Assays for Cell Analysis

SPECIFIC IMMUNITY = ACQUIRED IMMUNITY = ADAPTIVE IMMUNITY SPECIFIC IMMUNITY - BASIC CHARACTERISTIC

Using Phosphoflow to Dissect Alterations in Cytokine- Induced Activation of Jak/STAT Pathway in Rheumatoid Arthritis

Supplementary Table 1: List of parameters used in this study. Parameter Unit Parameter Unit Clinical parameters CD4 T cells Microbial translocation

Technical Bulletin No. 157

B220 CD4 CD8. Figure 1. Confocal Image of Sensitized HLN. Representative image of a sensitized HLN

Successful flow cytometric immunophenotyping of body fluid specimens

Effector T Cells and

Supplementary Information

Immunological alterations in mice irradiated with low doses

DISCOVERING ATCC IMMUNOLOGICAL CELLS - MODEL SYSTEMS TO STUDY THE IMMUNE AND CARDIOVASCULAR SYSTEMS

BD OneFlow LST Application Guide

Supplemental Information. Human CD1c + Dendritic Cells Drive. the Differentiation of CD103 + CD8 + Mucosal Effector T Cells via the Cytokine TGF-

Ex vivo Human Antigen-specific T Cell Proliferation and Degranulation Willemijn Hobo 1, Wieger Norde 1 and Harry Dolstra 2*

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Vaccine Delivery and TLR Ligands Influence the Quality of T cell Responses in NHP. Robert A. Seder, M.D. Vaccine Research Center NIAID, NIH

Supplementary Information:

Flow cytometry leukocyte differential : a critical appraisal

The CAPRI-T was one of two (along with the CAPRI-NK, see reference. [29]) basic immunological studies nested within the CAMELIA trial.

DIFFERENCES IN T-CELL SUBSETS IN ME/CFS. University of Nevada, Reno. Determining the Difference Between Circulating Follicular Regulatory T-cells and

Allergy. pp. 4 5 pp. 6 7 pp BAT Allergens Antibodies

Supplemental Table I.

IMMUNE CELL SURFACE RECEPTORS AND THEIR FUNCTIONS

Urine/CSF Albumin Reagent. Urine/CSF Albumin Calibrator

Application Note. Productivity and Efficiency of 6-Color BD Multitest and BD Trucount Technologies for Enumeration of Lymphocyte Subsets

January 25, 2017 Scientific Research Process Name of Journal: ESPS Manuscript NO: Manuscript Type: Title: Authors: Correspondence to

T-Cell Research. Novel multicolor flow cytometry tools for the study of CD4 + T-cell differentiation and plasticity

Kerrie Clerici, Michael Swain, Dominic Fernandez, Julia Schulz, Matthew Archer, Janine Campbell

Supplementary Figure 1. Efficient DC depletion in CD11c.DOG transgenic mice

Supplementary Appendix

Supplementary Table; Supplementary Figures and legends S1-S21; Supplementary Materials and Methods

Annexin V APC Assay Kit

Children's Hospital of Pittsburgh Annual Progress Report: 2011 Formula Grant

SUPPORTING INFORMATIONS

How to set up a good protocol or Polychromatic flow cytometry: Advantages and pitfalls

Superior Fluorescent Labeling Dyes Spanning the Full Visible Spectrum...1. Trademarks: HiLyte Fluor (AnaSpec, Inc.)

In vitro human regulatory T cell suppression assay

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)

What to Measure, How to Measure It

Cover Page. The handle holds various files of this Leiden University dissertation.

Regulation of anti-tumor immunity through migration of immune cell subsets within the tumor microenvironment Thomas F. Gajewski, M.D., Ph.D.

T H 1, T H 2 and T H 17 polarization of naïve CD4 + mouse T cells

x Lymphocyte count /µl CD8+ count/µl 800 Calculated

GE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

CD90 + Human Dermal Stromal Cells Are Potent Inducers of FoxP3 + Regulatory T Cells

NK cell flow cytometric assay In vivo DC viability and migration assay

Reliable, cost-effective CT/GC testing For labs with low to medium throughput needs. The BD ProbeTec ET System

5/1/13. The proportion of thymus that produces T cells decreases with age. The cellular organization of the thymus

Automatic buffy coat extraction: methodology, feasibility, optimization and validation study

Rapid and Robust B Cell Depletion in Preliminary Results of a Phase 2 Study of Ublituximab, Novel Glycoengineered Anti-CD20 Mab, RMS Patients

Page 1 of 2. Product Information Contents: ezkine Th1 Activation 2 Whole Blood Intracellular Cytokine Kit

Supporting Information

MHC MULTIMER PROFICIENCY PANEL 2017

Product # R8132 (Explorer Kit) R8133 (Bulk Kit)

Glow. Save. Let it. and. Get a Discount of 10% BD Biosciences Year End Promotion on a huge Selection of Reagent Solutions

Transcription:

DuraClone IM Standardized phenotyping panels for studies of the human immune system

Standardize with the experts, adopt DuraClone IM Tubes. Clinical research studies require accurate, reproducible results that can be compared between laboratories and across geographies. DuraClone IM Tubes raise the bar to a new level of quality and standardization in high content flow cytometry. Based on collaborative work with The ONE Study consortium, DuraClone IM marker and dye selections have been designed and optimized by expert flow labs. www.onestudy.org Standardization of whole blood immune phenotype monitoring for clinical trials: panels and methods from the ONE study Mathias Streitz, Tewfik Miloud, Michael Kapinsky, Michael R Reed, Robert Magari, Edward K Geissler, James A Hutchinson, Katrin Vogt, Stephan Schlickeiser, Anders Handrup Kverneland, Christian Meisel, HansDieter Volk and Birgit Sawitzki, Transplantation Research 2013, 2:17 doi:10.1186/20471440217 Standardized phenotyping panels for studies of the human immune system The continuous increase of multiplexing capability in cytometry allows to choose from an extensive menu of markers and fluorochromes. In order not to compromise data accuracy and comparability across multiple study sites, standardization of immune phenotyping panels is strongly implied. With the DuraClone IM tubes, Beckman Coulter provides a standardized set of panels that reveal a comprehensive image of a human individual s immune system. The panels have been developed by expert labs from the ONE study consortium striving for most informative marker combinations along an optimal choice of fluorochromes.

Worryfree compensation for high content flow cytometry. Banish the idea that high content flow is complicated due to tedious compensation adjustments. DuraClone IM Tubes are provided with a robust compensation solution which delivers the standardization and workflow efficiency required for clinical research studies. Three dried reagent single color compensation kits are provided in each package of 25 assay tubes. DuraClone IM single color conjugate compensation tubes are colorcoded with lotmatched dyes, specific for each panel. Reduce handson time, waste and rework Eliminate errors due to manual liquid reagent cocktail preparation with these readytouse, unitized dried reagent panels. + Add Blood Sample The simplified workflow makes DuraClone IM Tubes the optimal choice for streamlining high content flow cytometry in clinical research studies. Add Lysis Solution + Acquire data by flow cytometry Custom Design Services

The Phenotyping Basic Tube delineates principal lymphocyte subsets as well as subpopulations of monocytes. B53309 DuraClone IM Phenotyping Basic Tube FITC PE ECD PC5.5 PC7 APC A700 (1) APC CD16 CD56 CD19 CD14 CD4 CD8 CD3 CD45 The B Cell Tube allows for identification of late maturation stages of B cells, such as: transitional stage, isotype classswitch, naïve and memory stages. B53318 DuraClone IM B cell Tube (1) A700 FITC PE ECD PC5.5 PC7 APC APC APCA700 (2) IgD CD21 CD19 CD27 CD24 CD38 IgM CD45 The T Cell Subsets Tube indicates maturation stages of T cells, covering naïve, effector, memory and terminal differentiation stages. B53328 DuraClone IM T cell subsets Tube FITC PE ECD PC5.5 PC7 APC A700 (1) APC CD45RA CCR7 CD28 PD1 CD27 CD4 CD8 CD3 CD57 CD45 (1) Alexa Fluor* 700 (2) APCAlexa Fluor* 700 (3) APCAlexa Fluor* 750 (4) Alexa Fluor* 647 For Research Use Only Not for use in Diagnostic procedures

The Dendritic Cells tube discriminates leukocytelineage positive cells and identifies plasmacytoid dendritic cells and 3 major subsets of myeloid dendritic cells. B53351 DuraClone IM Dendritic cell Tube FITC PE ECD PC5.5 PC7 APC APC A700 (2) APC CD16 Lineage CD1c CD11c Clec9A CD123 HLADR CD45 CD3 / CD19 / CD20 / CD14 / CD56 The TCRs Tube allows for assessment of TCR αβ and γδ protein chain expression and to detect Vδ1 + and Vδ2 + subsets among TCRγδ + T cells. B53340 DuraClone IM TCR subsets Tube FITC PE ECD PC5.5 PC7 APC A700 (1) APC TCRgd TCRab HLADR TCRVd1 CD4 CD8 CD3 TCRVd2 CD45 The Treg Tube enables identification and characterization of FoxP3 + regulatory T cells using a fast permeabilization protocol. B53346* DuraClone IM Treg Tube * : available from July 2015. The final configuration of the product is subject to change until launch of the product. (1) A700 (4) APC FITC PE ECD PC5.5 PC7 A647 APCA700 (2) CD45RA CD25 CD39 CD4 FoxP3 CD3 Helios CD45 (1) Alexa Fluor* 700 (2) APCAlexa Fluor* 700 (3) APCAlexa Fluor* 750 (4) Alexa Fluor* 647 For Research Use Only Not for use in Diagnostic procedures

DuraClone IM Tubes For Research Use Only Not for use in Diagnostic procedures Premixed, dried reagent cocktails to standardize and streamline flow cytometry workflow for clinical research studies involving the identification of principal populations of the human immune system. 488 nm 633 nm 405 nm NEW PN Panels FITC PE ECD PC5.5 PC7 B53309 B53318 B53328 B53351 B53340 B53346* DuraClone IM Phenotyping Basic Tube DuraClone IM B cell Tube DuraClone IM T cell subsets Tube DuraClone IM Dendritic cell Tube DuraClone IM TCRs Tube DuraClone IM Treg Tube *: available from July 2015. The final configuration of the product is subject to change until launch of the product. CD3 / CD19 / CD20 / CD14 / CD56 APC A647 (4) CD4 CD16 CD56 CD19 CD14 CD24 IgD CD21 CD19 CD27 CD4 CD45RA CCR7 CD28 PD1 CD27 Clec9A CD16 Lineage CD1c CD11c A700 (1) CD8 CD8 TCRgd TCRab HLADR TCRVd1 CD4 CD8 CD45RA CD25 CD39 CD4 FoxP3 APC A700 (2) (1) Alexa Fluor* 700 (2) APCAlexa Fluor* 700 (3) APCAlexa Fluor* 750 (4) Alexa Fluor* 647 CD123 APC * CD3 CD45 CD38 IgM CD45 CD3 CD57 CD45 HLADR CD45 CD3 TCRVd2 CD45 CD3 Helios CD45 Contact your sales representative or visit www.duraclone.com/im * Alexa Fluor and Blue are registered trademarks of Molecular Probes, Inc. ECD and are trademarks of Beckman Coulter, Inc. Beckman Coulter, DuraClone and the stylized logo are trademarks of Beckman Coulter, Inc. and are registered in the USPTO. FLOW895SB05.15A 2015 Beckman Coulter, Inc. PRINTED IN U.S.A.