Diagnostic reagent for quantitative in vitro determination of Urea / Blood Urea Nitrogen in serum, plasma and urine by colorimetry.

Similar documents
ABX Pentra. HbA1c WB. Reagent for quantitative in-vitro determination of Hemoglobin A1c (HbA1c). A11A01702

Creatinine Test Code: CRE

GLUH PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Estimation of Serum Urea. BCH472 [Practical] 1

For in vitro diagnostic use only. For Rx use only. Reviewed by Date Reviewed by Date

Estimation of Serum Urea and Urine Urea. Amal Alamri

For In Vitro Diagnostic Use

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems.

BCH 447. Estimation of Serum Urea

UREA CE Insert. 01 English - Ref.: 27. Ref.:27

BÜHLMANN fcal turbo. Calprotectin turbidimetric assay for professional use. Reagent Kit B-KCAL-RSET. Revision date:

INSTRUCTIONS FOR USE

ICT (Na +, K +, Cl ) Sample Diluent

Estimation of Serum Urea

In Vitro Diagnostic Glucose Test System

COCAINE-QUALITATIVE IMMUNOASSAY (COC) Wedges each contain usable volumes of 23 ml of R1 reagent and 9 ml of R2 reagent.

Active-B12 (Holo-TC) ELISA KIT

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems and the AEROSET System.

Applicable To Employees of Gundersen Boscobel Area Hospital Laboratory and Gundersen Palmer Lutheran Hospital and Clinics Laboratory.

Evaluation of Cheongmeak DCS TM Reagents for Chemistry Analyzers

Aspartate Aminotransferase Test Code: AST

Kinetic assay of serum and urine for urea with use of urease and leucine dehydrogenase

INSTRUCTIONS FOR USE

For In Vitro Diagnostic Use. Rx Only. Reviewed by Date Reviewed by Date

Evaluation of VACUETTE Urine CCM tube for Clinical Chemistry

1. Reagent Store at 2-8 ºC.

Standard Operating Procedure

ELEGANCE Chlamydia pneumoniae IgG ELISA KIT

Creatinine (serum, plasma)

HDL CHOLESTEROL. 01 English - Ref.: 13. Ref.:13. Insert

AIA-600II Assay Specifications TgAb Test Code 048

Non-Protein Nitrogenous Compounds. Non-Protein Nitrogenous Compounds. NPN s. Urea (BUN) Creatinine NH 3. University of Cincinnati MLS Program 1

1. Calibra - H - Store at 2-8 ºC.

Standard Operating Procedure

The Virtues and Pitfalls of Implementing a New Test

Human Hemoglobin Colorimetric Detection Kit

Urea Nitrogen (BUN) detection Kit

METHOD VALIDATION CASE

AIA-360 Assay Specifications ST ACTH Test Code 106

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

Evaluation Report. Eurolyser PT (INR) test kit (ST0180) on CUBE and smart analysers

H.Pylori IgM Cat # 1504Z

H.Pylori IgG

H.Pylori IgG Cat # 1503Z

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

ASSAYED URINE CONTROL - LEVEL 2 (URN ASY CONTROL 2)

Phosphorus Test Code: PHOS

METHOD VALIDATION CASE

Glutamine Kit. For the determination of glutamine and glutamate in human EDTA plasma and serum. For research use only K 7732.

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Direct HbA1c testing capabilities on the RX modena

Toxoplasma gondii IgM ELISA Kit

Reference Material Institute for Clinical Chemistry Standards (ReCCS)

VGKC-Autoantibody Assay RIA

HbA1c3 PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

TSH ELISA Kit Medical Device Licence No.: 16419

A150 Product Number 31150

1.2 Synonyms There are several synonyms e.g. diaminomethanal, but in a medical context, this substance is always referred to as urea.

LDL LD. 01 English - Ref.: 129. Ref.:129. Insert. Intended use. Methodology. Reagents. Test principle. Summary. Precautions and warnings

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

GLUCOSE Liquiform. 01 English - Ref.: 133. Ref.:133. Insert. Intended use. Methodology. Reagents. Principle Precautions and warnings. Summary.

H. pylori IgM. Cat # H. pylori IgM ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

Stability of VACUETTE Lithium Heparin Separator tubes with modified centrifugation conditions

VetScan Critical Care Plus

USING THE ACCESS AMH ASSAY IN YOUR LABORATORY

Rubella virus IgG ELISA Kit

Human Cytomegalovirus IgM ELISA Kit

Blood Urea Nitrogen Detection Kit

References Required document for Laboratory Accreditation by the College of American Pathologists.

Vedolizumab Drug Level ELISA

TSH Receptor Autoantibody ELISA

MLT Intact Proinsulin Kit

TABLE OF CONTENTS GENERAL INFORMATION... 1

ASSAYED URINE CONTROL - LEVEL 3 (URN ASY CONTROL 3)

FinTest TM IgG4 Screen 88 ELISA Kit

Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000

OraSure Technologies, Inc Eaton Avenue, Bethlehem, PA Phone: (610) (USA) Fax: (610)

APOLIPOPROTEIN A1. This package insert contains information to run the Apolipoprotein A1 assay on the ARCHITECT c Systems and the AEROSET System.

See external label 2 C-8 C 96 tests Chemiluminescence. CMV IgM. Cat # Diluted samples, controls & calibrator 100 µl 30 minutes

DIAGNOSTIC AUTOMATION, INC.

Evaluation Report. Eurolyser HbA1c Test Kit on Smart and Cube Analyser

Gentian Canine CRP Immunoassay Application Note for scil VitroVet*

ab Creatinine Assay Kit (Colorimetric)

Toxoplasma gondii IgM ELISA Kit

HemoCue Hb METHOD AND SAMPLE COLLECTION

Journal of Medical Science & Technology

RENAL FUNCTION ASSESSMENT ASSESSMENT OF GLOMERULAR FUNCTION ASSESSMENT OF TUBULAR FUNCTION

Applicable To Employees of the Gundersen Boscobel Area Hospital Laboratory and Gundersen Palmer Lutheran Hospital and Clinics laboratories.

QUALITROL 2H Insert. 01 Inglês - Ref.: 72. Ref.:72. Precautions and warnings

PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

25-Hydroxy Vitamin D TOTAL (25HD) on Liaison XL

Chymotrypsin ELISA Kit

See external label 2 C-8 C Σ=96 tests Cat # 1505Z. MICROWELL ELISA H.Pylori IgA Cat # 1505Z

Testosterone ELISA. Catalog No (96 Tests) For Research Use Only. Not for use in Diagnostic Procedures.

READ HIGHLIGHTED CHANGES

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

Transcription:

2013/07/30 A93A01315AUS A11A01641 60 ml 15 ml Pentra C400 Diagnostic reagent for quantitative in vitro determination of Urea / Blood Urea Nitrogen in serum, plasma and urine by colorimetry. QUAL-QA-TEMP-0846 Rev.8 Application Release Serum, plasma: World wide except the USA: Urea 1.xx For the USA only: BUN 1.xx Urine: World wide except the USA: Urea-U 1.xx For the USA only: BUN-U 1.xx Intended Use reagent is intended for the quantitative in vitro diagnostic determination of urea/urea nitrogen (an end-product of nitrogen metabolism) in human serum, plasma and urine based on an enzymatic UV test using urease and glutamate dehydrogenase. Measurements obtained by this device are used in the diagnosis and treatment of certain renal and metabolic diseases. Clinical Interest (1, 2) Urea is the nitrogen-containing end product of protein catabolism. States associated with elevated levels of urea in blood are referred to as hyperuremia or azotemia. Parallel determination of urea and creatinine is performed to differentiate between pre-renal and post-renal azotemia. Pre-renal azotemia, caused by e.g. dehydration, increased protein catabolism, cortisol treatment or decreased renal perfusion, leads to increased urea levels, while creatinine values remain within the reference range. In post-renal azotemias, caused by the obstruction of the urinary tract, both urea and creatinine levels rise, but creatinine in a smaller extent. In renal diseases urea concentrations are elevated when the glomerular filtration rate is markedly reduced and when the protein intake is higher than 200 g/ day. Method (3) Urease - GLDH : enzymatic UV test. Urease Urea + 2H 2 O > 2NH + 4 + 2 HCO - 3 GLDH 2-Oxoglutarate + NH + 4 + NADH > L-Glutamate + NAD + + H 2 O (GLDH = Glutamate dehydrogenase) Reagents is ready-to-use. Reagent 1: TRIS ph 7.8 2-Oxoglutarate ADP Urease GLDH (Glutamate dehydrogenase) Sodium azide Reagent 2: NADH Sodium azide 150 9 0.75 7 ku/l 1 ku/l < 1 g/l 1.3 < 1 g/l should be used according to this reagent notice. The manufacturer cannot guarantee its performance if used otherwise. 1 / 6

Handling 1. Remove both caps of the cassette. 2. If present, remove foam by using a plastic pipette. 3. Place the cassette into the refrigerated Pentra C400 reagent compartment. Calibrator For calibration, use: Multical, Ref. A11A01652 (not included) 10 x 3 ml (lyophilisate) For internal quality control, use: N, Ref. A11A01653 (not included) 10 x 5 ml (lyophilisate) P, Ref. A11A01654 (not included) 10 x 5 ml (lyophilisate) Urine L/H, Ref. A11A01674 (not included) 1 x 10 ml + 1 x 10 ml Each control should be assayed daily and/or after a calibration. The frequency of controls and the confidence intervals should correspond to laboratory guidelines and countryspecific directives. You should follow federal, state and local guidelines for testing quality control materials. The results must be within the range of the defined confidence limits. Each laboratory should establish a procedure to follow if the results exceed these confidence limits. Materials Required but not Provided Automated clinical chemistry analyzer: Pentra C400 Calibrator: Multical, Ref. A11A01652 s: N, Ref. A11A01653, and P, Ref. A11A01654 Urine L/H, Ref. A11A01674 Standard laboratory equipment. Specimen Serum. Plasma in lithium heparin. Fresh urine Anticoagulants other than those listed have not been tested by HORIBA Medical and are therefore not recommended for use with this assay. Stability in serum/plasma (1): 2 days at room temperature 1 week at 4-8 C Stability in urine (4): 4 weeks at - 20 C if ph < 7.0 4 days at 4-8 C if ph < 7.0 2 days at 20-25 C if ph < 7.0 Reference Range Each laboratory should establish its own reference ranges. The values given here are used as guidelines only. Serum, plasma (1): Urea BUN Adults: [] [] [] Global 17-43 2.8-7.2 7.9-20.2 Women < 50 years 15-40 2.6-6.7 7.3-18.8 Women > 50 years 21-43 3.5-7.2 9.8-20.2 Men < 50 years 19-44 3.2-7.3 9.0-20.5 Men > 50 years 18-55 3.0-9.2 8.4-25.8 Urea BUN Children: [] [] [] 1-3 years 11-36 1.8-6.0 5.1-16.8 4-13 years 15-36 2.5-6.0 7.0-16.8 14-19 years 18-45 2.9-7.5 8.1-21.1 Urine (5): Urea [mmol/24h] BUN [mg/24h] 430-710 1207-1993 Storage and Stability Reagents, in unopened cassettes, are stable up to the expiry date on the label if stored between 2-8 C. Stability after opening: refer to the paragraph "Performance on Pentra C400". Do not freeze the reagents. 2 / 6

Packaging spoiling In case of protective packaging spoiling, do not use the reagent if the damages might have an effect on the product performance. Waste Management Please refer to local legal requirements. This reagent contains less than 0.1% of sodium azide as a preservative. Sodium azide may react with lead and copper to form explosive metal azides. General Precautions This reagent is for professional in vitro diagnostic use only. Do not swallow. Avoid contact with skin and mucous membranes. Observe the standard laboratory precautions for use. The reagent cassettes are disposable and should be disposed of in accordance with the local legal requirements. Please refer to the MSDS associated with the reagent. Do not use the product if there is visible evidence of biological, chemical or physical deterioration. Performance on Pentra C400 The performance data listed below are representative of performance on HORIBA Medical Systems. Serum, plasma Number of Tests: 220 tests If the number of tests requested is low and the Pentra C400 user intends to utilise the cassette to the maximum on board stability, it is the recommendation of HORIBA Medical, to utilise the consumable part XEC084 (Kit membrane) to achieve the number of tests stated in this notice. On Board Reagent Stability: Once opened, the reagent cassette placed in the refrigerated Pentra C400 compartment is stable for 70 days. Sample Volume: 3.0 µl/test 0.9 Accuracy and Precision: Repeatability (within-run precision) 3 specimens of low, medium and high concentration and 2 controls are tested 20 times according to the recommendations found in the Valtec protocol (6). 6.68 40.1 2.27 25.93 155.6 1.66 Specimen 1 2.15 12.9 2.76 Specimen 2 7.43 44.6 1.58 Specimen 3 30.45 182.7 1.80 Mean value BUN (mg/dl) CV % 18.73 2.27 72.78 1.66 Specimen 1 6.02 2.76 Specimen 2 20.86 1.58 Specimen 3 85.46 1.80 Reproducibility (total precision) 2 specimens (low and high levels) and 2 controls are tested in duplicate for 20 days (2 series per day) according to the recommendations found in the CLSI (NCCLS), EP5-A protocol (7). 6.57 39.4 2.14 25.54 153.2 1.93 Specimen 1 6.86 41.1 2.14 Specimen 2 24.98 149.9 1.97 Limit of Detection: The detection limit is determined according to the Valtec protocol (6) and equals: 0.31 (1.86 ) 3 / 6

Mean value BUN (mg/dl) CV % 18.45 2.14 71.69 1.93 Specimen 1 19.24 2.14 Specimen 2 70.12 1.97 Measuring Range: The assay confirmed a measuring range from 0.37 to 49.49 (2.20 to 297.22 ), with an automatic post-dilution up to 250.00 (1500.0 ). 50.00 (300.00 ) according to the recommendations found in the CLSI (NCCLS), EP6-A protocol (8). The assay confirmed a measuring range from 1.03 to 138.89, with an automatic post-dilution up to 701.5. 140.3 according to the recommendations found in the CLSI (NCCLS), EP6-A protocol (8). Correlation: 136 patient samples (serum and plasma) are correlated with a commercial reagent taken as reference according to the recommendations found in the CLSI (NCCLS), EP9- A2 protocol (9). Values ranged for Urea from 0.37 to 49.49 (2.20 to 297.22 ). Values ranged for BUN from 1.03 to 138.89. The equation for the allometric line obtained using Passing-Bablock regression procedure (10) is: Y = 0.99 X - 0.02 () Y = 0.99 X - 0.12 () with a correlation coefficient r 2 = 0.996 Y = 0.99 X - 0.06 () with a correlation coefficient r 2 = 0.996 Interferences: Haemoglobin: No significant influence is observed up to 267 µmol/l (460 ). Triglycerides: Total Bilirubin: No significant influence is observed up to an Intralipid concentration (representative of lipemia) of 7 (612.5 ). No significant influence is observed up to 380 µmol/l (22.23 ). Direct Bilirubin: No significant influence is observed up to 400 µmol/l (23.40 ). Other limitations are given by Young as a list of drugs and preanalytical variables known to affect this methodology (11, 12). Calibration Stability: The reagent is calibrated on Day 0. The calibration stability is checked by testing 2 control specimens. The calibration stability is 8 days. Note: A recalibration is recommended when reagent lots change, and when quality control results fall outside the range established. Application release: 1.xx 1.xx Urine Number of Tests: 220 tests If the number of tests requested is low and the Pentra C400 user intends to utilise the cassette to the maximum on board stability, it is the recommendation of HORIBA Medical, to utilise the consumable part XEC084 (Kit membrane) to achieve the number of tests stated in this notice. On Board Reagent Stability: Once opened, the reagent cassette placed in the refrigerated Pentra C400 compartment is stable for 70 days. Sample Volume: 3.0 µl/test Limit of Detection: The detection limit is determined according to the Valtec protocol (6) and equals: 12.6 (75.6 ) 35 4 / 6

Accuracy and Precision: Repeatability (within-run precision) 3 specimens of low, medium and high concentration and 2 controls are tested 20 times according to the recommendations found in the Valtec protocol (6). 129.13 774.8 1.24 223.73 1342.4 0.74 Specimen 1 91.55 549.3 1.76 Specimen 2 173.65 1041.9 1.44 Specimen 3 521.62 3129.7 0.72 Mean value BUN (mg/dl) CV % 363 1.24 628 0.74 Specimen 1 257 1.76 Specimen 2 488 1.44 Specimen 3 1465 0.72 Reproducibility (total precision) 2 specimens (medium and high levels) and 2 controls are tested in duplicate for 20 days (2 series per day) according to the recommendations found in the CLSI (NCCLS), EP5-A protocol (7). 128.58 771.5 3.80 216.27 1297.6 4.13 Specimen 1 198.13 1188.8 3.42 Specimen 2 547.82 3286.9 3.08 Mean value BUN (mg/dl) CV % 361 3.80 607 4.13 Mean value BUN (mg/dl) CV % Specimen 1 556 3.42 Specimen 2 1538 3.08 Measuring Range: The assay confirmed a measuring range from 12.6 to 750.0 (75.6 to 4500 ), with an automatic post-dilution up to 3750 (22500 ). 750.0 (4500 ) according to the recommendations found in the CLSI (NCCLS), EP6-A protocol (8). The assay confirmed a measuring range from 35 to 2106, with an automatic post-dilution up to 10530. 2106 according to the recommendations found in the CLSI (NCCLS), EP6-A protocol (8). Correlation: 108 patient samples (urine) are correlated with a commercial reagent taken as reference according to the recommendations found in the CLSI (NCCLS), EP9-A2 protocol (9). Values ranged for Urea from 16.0 to 722.5 (96 to 4340 mg/l). Values ranged for BUN from 45 to 2029. The equation for the allometric line obtained using Passing-Bablock regression procedure (10) is: Y = 1.14 X - 1.77 () Y = 1.14 X - 10.63 () with a correlation coefficient r 2 = 0.9946 Y = 1.14 X - 4.90 () with a correlation coefficient r 2 = 0.9946 Interferences: Haemoglobin: No significant influence is observed up to 290 µmol/l (500 ). Direct Bilirubin: No significant influence is observed up to 650 µmol/l (38 ). Other limitations are given by Young as a list of drugs and preanalytical variables known to affect this methodology (11, 12). Calibration Stability: The reagent is calibrated on Day 0. The calibration stability is checked by testing 2 control specimens. 5 / 6

The calibration stability is 8 days. Note: A recalibration is recommended when reagent lots change, and when quality control results fall outside the range established. Application release: 1.xx 1.xx Conversion factor (1) Urea () = Urea () x 0.1665 BUN() = Urea () / 2.14 BUN() = Urea () / 0.3561 9. Method Comparison and Bias Estimation Using Patient Samples. Approved Guideline, 2 nd ed., CLSI (NCCLS) document EP9-A2 (2002) 22 (19). 10. Passing H, Bablock W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. J. Clin. Chem. Clin. Biochem. (1983) 21: 709-20. 11. Young DS. Effects of Drugs on Clinical Laboratory Tests. 4 th Edition, Washington, DC, AACC Press (1997) 3: 143-163. 12. Young DS. Effects of Preanalytical Variables on Clinical Laboratory Tests. 2 nd Edition, Washington, DC, AACC Press (1997) 3: 120-132. Warning It is the user's responsibility to verify that this document is applicable to the reagent used. Reference 1. Thomas L. Clinical Laboratory Diagnostics. 1 st ed. Frankfurt: THBooks Verlagsgesellschaft (1998): 374-377. 2. Burtis CA, Ashwood ER, editors. Tietz Textbook of Clinical Chemistry. 3 rd ed. Philadelphia: W.B Saunders Company (1999): 1838. 3. Talke H, Schubert GE. Enzymatische Harnstoffbestimmung in Blut und Serum im optischen Test nach Warburg (Enzymatic determination of urea in blood and serum with the optical test according to Warburg). Klin. Wochenschr (1965) 43: 174-175. 4. Guder WG, Zawta B. The Quality of Diagnostics Samples. Samples: From the Patient to the Laboratory. 1 st Ed. Guder WG, Narayanan S, Zawta B. (WHILEY-VCH, Darmstadt, Germany) (2001): 52-53. 5. Roberts WL, McMillin GA, Burtis CA, Bruns DE. Reference Information for the Clinical Laboratory, TIETZ Textbook of Clinical Chemistry and Molecular Diagnostics. 4 th Ed., Burtis CA, Ashwood ER, Bruns DE, (Elsevier Saunders eds., St Louis, USA) (2006): 2301. 6. Vassault A, Grafmeyer D, Naudin C et al. Protocole de validation de techniques (document B). Ann. Biol. Clin. (1986) 44: 686-745. 7. Evaluation of Precision Performance of Clinical Chemistry Devices. Approved Guideline, CLSI (NCCLS) document EP5-A (1999) 19 (2). 8. Evaluation of the Linearity of Quantitative Analytical Methods. Approved Guideline, CLSI (NCCLS) document EP6-A (2003) 23 (16). 6 / 6