Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture

Similar documents
SURGERY OF THE HAND INTRODUCTION CASE REPORT. Hee-June Kim 1, Hyun-Joo Lee 1, Dong-Hyun Kim 1, Joon-Woo Kim 1, Ji Won Oh 2

Acute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture

Emile N. Brown, MD, and Scott D. Lifchez, MD

엄지의수근중수관절염에의한장무지신건의특발성파열 : 증례보고

Acute Rupture of Flexor Digitorum Profundus Tendon Associated with Distal Radius Fracture: A Case Report

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

Bilateral Trans-Scaphoid Perilunate Fracture Dislocation

SURGERY OF THE HAND. Basosquamous Carcinoma of the Hand in a Radiologist with Prolonged Radiation Exposure INTRODUCTION CASE REPORT CASE REPORT

The Utility of the Fluoroscopic Skyline View During Volar Locking Plate Fixation of Distal Radius Fractures

Intratendinous Ganglion of the Extensor Digitorum Tendon

Intrinsic muscles palsies of the hand Management of Thumb Opposition with BURKHALTER s Procedure

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

Clinical Orthopaedic Rehabilitation Volume 1 and 2

AJO needle, and compartment pressures were measured

Hardware-Related Complications After Dorsal Plating for Displaced Distal Radius Fractures

Manual Kirschner-Wire Insertion through the Soft Tissue for Finger Immobilization after Scar Contracture Release

WINSTA-R. Distal Radius System

Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study

Classification of Established Volkmann s Ischemic Contracture and the Program for Its Treatment

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Percutaneous Multiple Kirschner Wire Fixation in the Treatment of Hand Fractures

Case Report Bone Resection for Isolated Ulnar Head Fracture

Physical therapy of the wrist and hand

Acu-Loc Wrist Plating System. Surgical Technique

The Effect of Distal Location of the Volar Short Arm Splint on the Metacarpophalangeal Joint Motion

MCQWeek2. All arise from the common flexor origin. The posterior aspect of the medial epicondyle is the common flexor origin.

Fractures and dislocations of the fingers

Trapezium is by the thumb, Trapezoid is inside

Distal radius fractures raises considerable interest and

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES

Acu-Loc Wrist Spanning Plate System. Surgical Technique

MR: Finger and Thumb Injuries

Main Menu. Wrist and Hand Joints click here. The Power is in Your Hands

Client centered approach to distal radius fracture management. Jared Rasmussen OTR

Kinesiology of The Wrist and Hand. Cuneyt Mirzanli Istanbul Gelisim University

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Comparison between Intramedullary Nailing and Percutaneous K-Wire Fixation for Fractures in the Distal Third of the Metacarpal Bone

SURGERY OF THE HAND. Results of Iliac Bone Graft with Kirschner Wire Fixation for Scaphoid Nonunions INTRODUCTION ORIGINAL ARTICLE

Index. Springer International Publishing Switzerland 2016 J.N. Lawton (ed.), Distal Radius Fractures, DOI /

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Lecture 9: Forearm bones and muscles

From the Department of Orthopedics, Tongji Hospital, Tongji University, Shanghai, China

Heterotopic Ossification of the Elbow after Medial Epicondylectomy

Clinical Study Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

Long-term Results of Dorsally Displaced Distal Radius Fractures Treated With the Pi-Plate: Is Hardware Removal Necessary?

Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures.

Common Limb Fractures. Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

Revisiting the Curtis Procedure for Boutonniere Deformity Correction

A novel method of treating isolated unicondylar fracture of the head of the proximal phalanx: A case report

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

The Birmingham Hook Plate Treatment Of Irreduceable Displaced Mallet Avulsion Fractures: A Technical Note

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

University of Groningen. Fracture of the distal radius Oskam, Jacob

Wrist and Hand Complaints

Wrist & Hand Ultrasonography 대구가톨릭대학교병원재활의학과 권동락

Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates

The Importance of Preoperative Imaging Study on a Solitary Neurofibroma Originated from the Digital Nerve

10/10/2014. Structure and Function of the Hand. The Hand. Osteology of the Hand

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.

Radial Nerve Palsy Following Fractures of the Humerus

8 Recovering From HAND FRACTURE SURGERY

Acu-Loc 2 Wrist Plating System

divided by the bones ( redius and ulna ) and interosseous membrane into :

Visualize, stabilize, mobilize. Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique

Surgical Technique Carpal Fusion

Simultaneous Bilateral Patellar Tendon Ruptures Associated with Osteogenesis Imperfecta

Wrist & Hand Assessment and General View

1/13/2013. Anatomy Guy Dissection Sheet Extensor Forearm and Hand. Eastern Virginia Medical School

Surgical Technique. Wrist Plating System

Treatment of unstable distal radius fractures with the volar locking plate

Clinical examination of the wrist, thumb and hand

Ultrasonography of the wrist - a step-by-step approach to study protocols and normal findings

Fracture and Dislocation of the Carpus ( 1-Jan-1985 )

Extensor Tendon Repair Zones II, III, IV

COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES

Identification of Double Compression Lesion of Ulnar Nerve after Cubital Tunnel Release

Interesting Case Series. Posterior Interosseous Nerve Compression

Introduction to Ultrasound Examination of the Hand and upper

Carpal rows injuries!

ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY

Hand Anatomy A Patient's Guide to Hand Anatomy

Hand injuries. The metacarpal bones may fracture through the base, shaft or the neck.

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

Nerves of Upper limb. Dr. Brijendra Singh Professor & Head Department of Anatomy AIIMS Rishikesh

SURGERY OF THE HAND. Synovial Chondromatosis of the Ulnocarpal Joint INTRODUCTION CASE REPORT CASE REPORT. Sung-Guk Kim

A Patient s Guide to Adult Olecranon (Elbow) Fractures

Forearm and Wrist Regions Neumann Chapter 7

Muscles of the hand Prof. Abdulameer Al-Nuaimi

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬

Distal Radius Plate 2.4/2.7 dorsal and volar

A N D R E W I R W I N, F R C S E D ( O R T H ) C O N S U L T A N T O R T H O P A E D I C S U R G E O N W E S T H E R T S N H S T R U S T, U K

Urgent Cases and Foreign Bodies

Management of Hand Palsies in Isolated C7 to T1 or C8, T1 Root Avulsions

Transcription:

CASE REPORT pissn 1598-3889 eissn 2234-0998 J Korean Soc Surg Hand 2015;20(1):23-27. http://dx.doi.org/10.12790/jkssh.2015.20.1.23 JOURNAL OF THE KOREAN SOCIETY FOR SURGERY OF THE HAND Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture Youn Moo Heo 1, Yougun Won 1,2, Jung Bum Lee 1, Tae Gyun Kim 1, Jae Ik Lee 1 1 Department of Orthopaedic Surgery, Konyang University Hospital, Konyang University College of Medicine, Daejeon, Korea 2 Department of Medicine, Yonsei University Graduate School, Seoul, Korea Received: October 22, 2014 Revised: [1] January 19, 2015 [2] February 16, 2015 Accepted: February 21, 2015 Correspondence to: Yougun Won Department of Orthopaedic Surgery, Konyang University Hospital, Konyang University College of Medicine, 158 Gwanjeodong-ro, Seo-gu, Daejeon 302-718, Korea TEL: +82-42-600-6937 FAX: +82-42-545-2373 E-mail: yougunwon@gmail.com Open reduction and internal fixation using volar plating for the treatment of distal radial fractures (DRFs) is becoming an increasingly popular method. Tenosynovitis of extensor tendons causes delayed extensor pollicis longus (EPL) tendon rupture which known as complication following screw penetration of the dorsal cortex after volar plating for DRFs. As the reconstructive procedure for a closed ruptured EPL tendon in minimal displaced DRF, extensor indicis proprius (EIP) transfer is widely used. However, tendon injuries of the fourth compartment, which includes the extensor digitorum communis or EIP, can be caused by screw irritation after volar plating for DRFs. We encountered a rare case of failed EIP tendon transfer for delayed EPL tendon rupture after volar plating for a DRF. Because the EIP tendon can also be damaged by screw penetration, care must be taken to use EIP tendon for treatment of delayed EPL rupture after volar plating for DRFs. Keywords: Extensor indicis proprius, Distal radius fracture, Tendon transfer, Volar plate fixation This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/ licenses/bync/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. INTRODUCTION The known complications of distal radial fractures (DRFs) include tendon rupture, tendon lag, trigger finger, and tenosynovitis 1. Open reduction and locking plate fixation via the volar approach for treatment of an unstable DRF is becoming an increasingly popular method and has been reported to cause tenosynovitis of the extensor tendons, which leads to delayed extensor tendon rupture 2. The extensor pollicis longus (EPL) tendon is most commonly ruptured. Screw penetration of the dorsal radius cortex to the third compartment after internal fixation of a volar plate for Copyright c 2015. The Korean Society for Surgery of the Hand 23

J Korean Soc Surg Hand Vol. 20, No. 1, March 2015 a DRF is thought to be the cause of EPL tendon rupture 3-5. The extensor digitorum communis (EDC) tendon and extensor indicis proprius (EIP) tendon can also be ruptured 6,7. In addition, de Boer et el. 8 reported rupture of both the EPL and EIP tendons after conservative treatment for a DRF. We encountered a rare case of failed EIP tendon transfer for delayed EPL tendon rupture after volar plate fixation for a DRF. Because the extensor tendons of the third and fourth compartments could also be damaged, the careful use of tendons for treatment of delayed EPL tendon rupture after volar plating for a DRF is necessary. protocol wearing a forearm splint with limited but progressively increased active flexion and extension of the interphalangeal (IP) joint. Ten days after the operation, he experienced sudden loss of extension of the affected thumb. The patient underwent surgical exploration, which revealed intact coupling of the EIP and EPL tendon. A ruptured stump was noted 2 cm proximal to the EIP tendon muscle junction (Fig. 3). The change of excursion or increased ten- CASE REPORT A 51-year-old, right hand dominant man sustained an extra-articular displaced right DRF 5 months prior to evaluation. He had undergone open reduction and internal fixation with a volar distal radius locking plate at another institution. After fracture healing, he regained pain-free function of his right hand and wrist. Three months after fracture fixation, he had no antecedent symptoms, but could not extend his thumb. Physical examination of the right wrist revealed normal range of motion. Other fingers also revealed normal range of motion except the thumb. He could flex his thumb but could not actively extend it. Radiographic evaluation of the right wrist revealed a healed fracture of the distal radius and screws that were excessively long penetrating the dorsal cortex (Fig. 1). We planned to perform EIP tendon transfer. Under general anesthesia, a skin incision was made vertically on the Lister s tubercle. With deeper dissection, the third compartment of the extension tendon group was exposed (Fig. 2). Surgical exploration revealed that the tips of screws had penetrated the lateral side of Lister s tubercle and the EPL tendon had ruptured over the distal edge. The extensor carpi radialis longus tendon of the second compartment had partially ruptured. Plate and screws were removed. We performed complete debridement of the granulated and frayed tissue in the ruptured margin, removed the plate, and transferred the EIP tendon. We did not assess the fourth compartment for screw penetration injury. Postoperatively, the patient underwent dynamic motion Fig. 1. (A, B) Radiograph showing a healed distal radius fracture and screws with extra length. Fig. 2. (A, B) Surgical exploration revealing the penetrated tips of screws and a frayed extensor pollicis longus tendon rupture over the distal edge. 24

Youn Moo Heo, et al. Failed EIP Tendon Transfer for EPL Tendon Rupture after Distal Radial Fracture Fig. 3. (A) Intact coupling of the EIP and EPL tendon. (B) A rupture can be seen proximal to the EIP tendon. (C) PL tendon transfer to the EPL. EIP, extensor indicis proprius; EPL, extensor pollicis longus. sion of the transferred EIP tendon injured by screw penetration was thought to be the cause of progression to a complete rupture. After debridement of the ruptured previously transferred EIP tendon, we attached the palmaris longus (PL) tendon graft to the ruptured site of EIP. Intact coupling of EIP and EPL tendon was preserved (Fig. 3). The same dynamic motion protocol was planned for rehabilitation. Three months after the second operation, full range of motion without a splint was allowed. At the 1-year followup examination, the patient could independently independent extend the thumb affected by the tendon without pain. DISCUSSION The incidence of reported complications from DRF is 6%- 80%. Known complications are nonunion, malunion, incongruent articulation, nerve, and tendon injury 1,2. Although palmar plating was reported to reduce the risk of tendon irritation, which is a major problem after dorsal plate fixation, the incidence of extensor tendon injury, most commonly the EPL tendon, was reported to be 2%-17% 1,2,9. Injuries to the flexor and extensor tendons include adhesion, simple irritation, and frank rupture 5,10. Tendon ruptures can occur as an early or late complication. Sharp fracture fragments cause early tendon rupture and irritation with the fixed plate, penetrated screws, and changed tendon excursion due to peritendinous adhesion cause late complications 1,3,10. Only few studies have reported other extensor tendon injuries. Al-Rashid et al. 4 reported 1 case of ruptured EDC tendon and EIP tendon and suggested that a dorsally penetrated screw was the cause. Singh et al. 6 reported EIP tendon and EDC tendon rupture after locking plate fixation of a DRF 7 months postoperatively, and found that the bony spur at the healed fracture site was the cause. Hattori et al. 7 reported delayed rupture of the EDC tendon after volar plating of a DRF. Penetration of the screw to the fourth extensor compartment was thought be the cause of the rupture. It is possible that the tendon of the third and fourth compartment can be injured at the same time. de Boer et el. 8 reported delayed EPL tendon rupture with a conservatively treated DRF. They found concomitant EDC II tendon injury during dissection for the EIP tendon transfer. The EIP tendon transfer can only be used if the EDC II tendon is intact. Sadr 11 reported sequential rupture of the EDC II tendon within 4 months after EPL tendon rupture. The treatment methods for EPL tendon rupture are EIP tendon 25

J Korean Soc Surg Hand Vol. 20, No. 1, March 2015 transfer, EPL reconstruction with intercalary tendon graft, and thumb IP arthrodesis 10. From May 2007 to April 2014, we encountered 12 cases of EPL tendon rupture combined with DRF. Direct repair of the EPL tendon was possible in only 1 case. Six of the 11 remaining patients underwent EIP tendon transfer and 5 of the 11 cases received a PL tendon graft. In this case, EPL function loss occurs 10 days after EIP transfer. Although penetration of the distal ulnar side screw was suspected on initial radiograph, we did not confirm the integrity of the extensor tendon of the fourth compartment. The coupling of EIP and EPL was intact. The location of ruptured EIP stump was more proximal which could be irritated by the penetrated screw. The injured EIP tendon couldn t bear the change of excursion or increased tension. When EIP transfer is planned for treatment of EPL tendon rupture after volar plating for a DRF, the integrity of the fourth extensor compartment should be considered. REFERENCES 1. urner RG, Faber KJ, Athwal GS. Complications of distal radius fractures. Hand Clin. 2010;26:85-96. 2. Esenwein P, Sonderegger J, Gruenert J, Ellenrieder B, Tawfik J, Jakubietz M. Complications following palmar plate fixation of distal radius fractures: a review of 665 cases. Arch Orthop Trauma Surg. 2013;133:1155-62. 3. Benson EC, DeCarvalho A, Mikola EA, Veitch JM, Moneim MS. Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res. 2006;451:218-22. 4. Al-Rashid M, Theivendran K, Craigen MA. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br. 2006;88:1610-2. 5. Davis DI, Baratz M. Soft tissue complications of distal radius fractures. Hand Clin. 2010;26:229-35. 6. Singh HP, Srinivasan S, Ullah A. Closed rupture of the extensor indicis and extensor digitorum tendons to the index finger after locking plate fixation of a fracture of the distal radius. J Hand Surg Eur Vol. 2013;38:86-7. 7. Hattori Y, Doi K, Sakamoto S, Yukata K. Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture. Hand Surg. 2008; 13:183-5. 8. de Boer SW, van Kooten EO, Ritt MJ. Extensor pollicis longus tendon rupture with concomitant rupture of the extensor digitorum communis II tendon after distal radius fracture. J Hand Surg Eur Vol. 2010;35:679-81. 9. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar lockingplate. J Orthop Trauma. 2007;21:316-22. 10. Leversedge FJ, Srinivasan RC. Management of soft-tissue injuries in distal radius fractures. Hand Clin. 2012;28:225-33. 11. Sadr B. Sequential rupture of extensor tendons after a Colles fracture. J Hand Surg Am. 1984;9:144-5. 26

Youn Moo Heo, et al. Failed EIP Tendon Transfer for EPL Tendon Rupture after Distal Radial Fracture 원위부요골골절의내고정술후발생한무지신전건파열에대한시지신건이전술후실패 허윤무 1 원유건 1,2 이정범 1 김태균 1 이재익 1 1 건양대학교병원정형외과학교실, 2 연세대학교대학원의학과 배측전위된원위부요골골절의치료에있어수장측접근법을통한관혈적정복술및금속내고정술은점점일반적인방법화되어가고있다. 신전건의건초염은원위요골골절의수장측금속판고정술후나사의배측피질골관통에따른합병증으로알려진장무지신전건파열을초래한다. 최소전위된원위요골골절에서장무지신전건파열재건술식의표준으로서, 시지신건의건이전술이널리이용되고있다. 하지만, 원위요골골절의수장측금속판고정술이후지속된나사의자극으로인해발생한제4신전건구획의건손상또한보고되었다. 저자들은원위요골골절의수장측금속판고정술이후발생한지연된장무지신전근파열에대해시지신건이전술시행후실패한증례를경험하였다. 시지신건또한손상될수있기때문에원위요골골절의수장측금속판고정술후발생한지연된장무지신전건파열의치료로시지신건이전술사용시주의를요한다. 색인단어 : 원위부요골골절, 건이전술, 시지신건, 수장측금속판고정 접수일 2014 년 10 월 22 일수정일 1 차 : 2015 년 1 월 19 일, 2 차 : 2015 년 2 월 16 일게재확정일 2015 년 2 월 21 일교신저자원유건대전광역시서구관저동로 158 건양대학교병원정형외과학교실 TEL 042-600-6937 FAX 042-545-2373 E-mail yougunwon@gmail.com 27