After a great surgery, why leave anything to chance?

Similar documents
The Synthetic Self-Adhesive Barrier to Cerebrospinal Fluid Leaks

Adherus Dural and Spinal Sealant as Adjuncts to Sutured Dural Repair in a Canine Lumbar Durotomy Repair Model

A NOVEL CAUSE FOR CAUDA- EQUINA SYNDROME WITH A NEW RADIOLOGICAL SIGN

Restoration not just repair

DuraMatrix Collagen Dura Substitute Membrane. Manufactured by: Collagen Matrix, Inc., Franklin Lakes, New Jersey

Neurosurgery is complex. DuraGen is the simple choice.

SYNTHECEL Dura Repair. Assurance and Versatility for Dura Reconstruction.

got you covered. Codman s The global leader in neurosurgery is your one-stop, comprehensive source for proven, market-leading dural repair solutions.

BioGlue Surgical Adhesive as a Dural Sealant in Neurosurgery Clinical Needs and Surgical Technique

Iatrogenic lumbar Pseudomeningocele: A case report and review of literature

Body Contouring Implants - Calf

Application of a hydrogel sealant improves watertight closures of duraplasty onlay grafts in a canine craniotomy model

Chiari FAQ's. 1. What is a Chiari Malformation?

Integra. TenoGlide Tendon Protector Sheet SURGICAL TECHNIQUE

Guidelines in the management of neural tube defects and hydrocephalus

Kiyoshi Ito, MD, Tatsuro Aoyama, MD, Takuya Nakamura, MD, Yoshiki Hanaoka, MD, Tetsuyoshi Horiuchi, MD, and Kazuhiro Hongo, MD

Durotomies with CSF leakage are one of the most

Incidental durotomy during spine surgery occurs in. Computed tomography guided epidural patching of postoperative cerebrospinal fluid leaks

LUMBAR DECOMPRESSION / DISCECTOMY SURGERY INFORMATION

Unintended durotomy during degenerative lumbar spine surgery (Incidence and management)

Straumann MembraGel The next generation membrane

Fleece-Bound Tissue Sealing in Microvascular Decompression

Lumbar Puncture. Practical Skills Teaching. Year 3 Medical Students MB BCh

Katherine Gibson-Corley DVM, PhD, DACVP. Pathology Grand Rounds March 27, 2014

Spinal Cord and Properties of Cerebrospinal Fluid: Options for Drug Delivery. SMA Foundation New York

NeuroMend. Collagen Wrap Conduits. Operative Technique

SPINAL CORD AND PROPERTIES OF CEREBROSPINAL FLUID: OPTIONS FOR DRUG DELIVERY

CSF Rhinorrhoea after Transsphenoidal Surgery

Published clinical papers

5.5. RETROSIGMOID APPROACH

Hernia. emoryhealthcare.org

Lyoplant Onlay. Adding another layer of confidence to every procedure. Aesculap Neurosurgery

Lumbar drains. Information for patients Neurosurgery

DMF Page 63. Description

The Nervous System PART C. PowerPoint Lecture Slide Presentation by Patty Bostwick-Taylor, Florence-Darlington Technical College

DuraMatrix portfolio. Restore with confidence

A guide to scalp care and proper transducer array placement

Cranial Postoperative Site: MR Imaging Appearance

Consumer summary. Endoscopic modified Lothrop procedure for the. treatment of chronic frontal sinusitis

CLOSES WITH SECURITY. LEAVES WITHOUT A TRACE.

Neurosurgical Techniques

PARADIGM SPINE. Minimally Invasive Lumbar Fusion. Interlaminar Stabilization

Temporal Lobe Cystic Collection and Associated Oedema: A Rare Complication of Translabyrinthine Resection of Vestibular Schwannoma

T HE continuity of the dura mater is a prime necessity. Various processes

Surgical dural tears: Prevalence and updated management protocol based on 1359 lumbar vertebra interventions

CorMatrix ECM Bioscaffold

POSTERIOR LUMBAR FUSION SURGERY INFORMATION

INSTRUCTIONS FOR USE FOR:

Safety and efficacy of a novel polyethylene glycol hydrogel sealant for watertight dural repair

ACDF. Anterior Cervical Discectomy and Fusion. An introduction to

Pain Management: Epidural Steroid Injections

Case Report Primary Dural Repair in Minimally Invasive Spine Surgery

Technique Guide with Application Forceps. FlapFix. Quick and stable fixation of cranial bone flaps following a craniotomy.

Management of Cerebrospinal Fluid Leaks

ervous system: central nervous system (CNS) and eripheral nervous system (PNS) NS includes the brain and spinal cord NS consists of the cranial

Chapter 14. The Brain Meninges and Cerebral Spinal Fluid

Meninges and Ventricles

Corresponding Author. A Modified Footplate for the Kerrison Rongeur

Fat Transfer

The Nervous System: The

Cranio-cervical decompression. Information for patients Neurosurgery

Frequently Asked Questions About Ommaya Reservoirs and Ommaya Taps for Pediatric

ACOUSTIC NEUROMAS. University of Florida ENT Clinic Patrick J. Antonelli, MD Matthew R. O Malley, MD

A Patient s Guide to Pain Management: Epidural Steroid Injections

ADVANCED BONE GRAFT SYSTEM OVERVIEW

5. COMMON APPROACHES. Each of the described approaches is also demonstrated on supplementary videos, please see Appendix 2.

Bard: Continence Therapy. Stress Urinary Incontinence. Regaining Control. Restoring Your Lifestyle.

micromend Skin Closure Device Pre-clinical Studies of Closure of Surgical Wounds in Live Pigs

Brain Meninges, Ventricles and CSF

SURGICAL TECHNIQUE GUIDE

Nervous Systems: Diversity & Functional Organization

Review date: February Lumbar Discectomy

Experience the Innovative Therapy for Benign Prostate Enlargement

Breast Augmentation - Saline Implants

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation

MAS TLIF MAXIMUM ACCESS SURGERY TRANSFORAMINAL LUMBAR INTERBODY FUSION AN INTRODUCTION TO

Meningioma tumor. Meningiomas are named according to their location (Fig. 1) and cause various symptoms: > 1

Functional Endoscopic Sinus Surgery

Procedure Manual and Catalog

Quality of Life. Quality of Motion. A Patient s Guide to. Artificial Lumbar Disc Replacement

Integra TenoGlide Tendon Protector Sheet

Evaluation of efficacy and biocompatibility of a novel semisynthetic collagen matrix as a dural onlay graft in a large animal model

The Reverse Galeal Hinge Flap: Another Valuable Technique in the Repair of Scalp

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

Minimally invasive subpial tonsillectomy for Chiari I decompression

CSF. Cerebrospinal Fluid(CSF) System

8 A SIMPLE FISTULA REPAIR, STEP BY STEP

NovoSorb BTM. A unique synthetic biodegradable wound scaffold. Regenerating tissue. Changing lives.

Partial Knee Replacement

A Patient s Guide to Pain Management: Epidural Steroid Injections

Posterior Lumbar Spinal Fusion

Management Strategies for Communited Fractures of Frontal Skull Base: An Institutional Experience

Traumatic brain injuries are caused by external mechanical forces such as: - Falls - Transport-related accidents - Assault

Incidental Durotomy/ Dural Tear.

Patient Information Brochure

Surgical techniques and procedures for cerebrovascular surgery. Surgery for the AVF at the cranio-cervical junction and high cervical spine

Total Knee Replacement

Technique Guide. Cranial Clamps with Application Instrument. Quick and stable fixation of cranial bone flaps following a craniotomy.

Transcription:

HyperBranch Medical Technology, Inc. creates innovative medical devices using synthetic hydrogels with novel tunable properties for use as surgical sealants in general and specialty surgery. The products are easy to use, strong enough to stop air and fluid leaks, a barrier to prevent unwanted adhesion formation, and inherently anti-microbial. After a great surgery, why leave anything to chance? Advanced Hydrogel Technology Superior strength during healing Minimal swelling Prevents adhesions Biodegradable Anti-microbial Provides a safe and effective water-tight seal. Closure with Confidence.

Cerebrospinal Fluid Leakage CSF leakage can result in headache, vomiting, dizziness, vertigo and other more serious complications like meningitis, arachnoiditis, and ultimately pseudomeningocele formation. The use of Adherus Dural Sealant improves the closure and reduces complications associated with CSF leakage. Adherus Dural Sealant was specifically formulated to meet the requirements for a watertight seal in cranial and spinal surgery. The physical characteristics of Adherus Dural Sealant coupled with an extended rate of degradation provide the necessary platform for proper healing to occur. Minimizes Dural Adhesions Scarring between the tissue layers is an unwanted side effect of many surgeries. In some cases, a second surgery may be required. For many patients, this surgery is complicated by scar tissue at the original surgical site, making it extremely difficult to isolate the anatomy in that location. Studies show that Adherus Dural Sealant minimizes dural adhesions and scarring by providing a protective shield between the dura and surrounding tissue. For instance, following a pre-clinical craniotomy study, Adherus Dural Sealant essentially eliminated dural adhesions and limited peridural fibrosis. (Protocol Report 2009-PD-02533-02840) Closure with Confidence in Spinal and Cranial Surgery Adherus Dural Sealant applied over collagen-based duraplasty material. Four Month Evaluation after Adherus Dural Sealant applied over duraplasty material. After four months no adhesions in canine model

Characteristics Three Applicator Systems 6ml Standard Adherus Sealant - (NUS-001) Extended Tip - (APP-100) 1.5ml Design For Minimal Invasive Procedures - Adherus mis (NUS-003) 6ml AutoSpray - Adherus AUTOSPRAY (NUS-006) Two Synthetic Components Activated Polyethylene Glycol Polyethyleneimine Crosslinking Components Reconstituted in Aqueous Solution Terminally Sterilized Room Temperature Storage Adherus Dural Sealant should be stored below 86 F (30 C). Key Properties Standard & AutoSpray MIS Set Time ~1 second ~30 seconds Swelling ~8% at Demensional ~0% Deminsional Burst Strength >physiological @ Day 40 >physiological @ Day 21 (50ml /G) Degradation ~90 days ~80 days Allows Cellular Infiltration to Facilitate Natural Healing Effectiveness Adherus Dural Sealant has been evaluated in canine durotomy and duraplasty repair models and proved to be 100% effective in preventing CSF leaks from dural incisions. No CSF leaks at any time point occurred in the treatment group, even when the CSF column was challenged to a superphysiological pressure. Comparison of Mean Terminal Cerebrospinal Leakage Pressure between Control and Treated Groups *No leaks observed at terminal pressure Day 8 Control Day 8 Treated

The persistence of Adherus Dural Sealant was also monitored by MRI (T2 coronal) on a monthly basis. After 90 days, it was noted that the hydrogel was no longer detected and prior to that point, no excessive swelling of the hydrogel resulting in compression of tissues occurred. Adherus Dural Sealant also exhibits anti-adhesion characteristics. Based on a rating scale* of zero to four, after one week, Adherus Dural Sealant-treated animals were consistently rated as a zero, indicating that the bone flap was easy to remove and no adhesions were present. The control animals all presented with adhesions that were typically rated as a two, indicating that there was moderate difficulty in removing the bone flap and moderate adhesions were present. Similar adhesion scoring was evident when Adherus Dural Sealant was used with collagen-based duraplasty materials. (Final Report 2007-PD-00787-01181) Duraplasty Special studies were conducted to determine the effectiveness of Adherus Dural Sealant when used with different types of duraplasty material. These studies enhance the previous craniotomy studies and provide compelling evidence for the use of Adherus Dural Sealant with both autologous and non-autologous duraplasty materials. (Protocol Report 2009-PD-02533-02840) Safety Adherus Dural Sealant is non-irritating, non-hemolytic, non-toxic, and non-mutagenic as determined by IS0-10993 testing. In vivo pre-clinical testing shows Adherus Spinal Sealant is non-neurotoxic. Histology Histological examination of tissues revealed that Adherus Dural Sealant was well tolerated. The study concluded that there were no adverse changes in the brain, calvarium, dura, meninges or non-nervous system organs associated with the test article. (Northern Biomidical Research Study 057-004) *Rating Scale: 0 Bone flap easily removed, no adhesions present 1 Bone flap removal not difficult, minimal adhesion 2 Moderate difficulty in removing bone flap, moderate adhesion 3 Considerable difficulty in removing bone flap, considerable adhesions 4 Extensive difficulty in removing bone flap, extensive adhesions present

Applications Standard Extended Tip AutoSpray Adherus Dural Sealant is intended for use as an adjunct to standard methods of dural repair, such as sutures, during neurosurgical intervention to provide watertight closure. The preparation time is minimal and easily accomplished by following the IFU. Adherus Dural Sealant should be used within 2 hours of preparation of the green precursor. When the solutions within the syringes are mixed together within the tip of the applicator, the precursors crosslink to form the hydrogel sealant. The resulting hydrogel sealant is absorbed over approximately 90 days, sufficient time to allow for healing. Minimally Invasive Applicator The Adherus MIS Applicator is designed for neurosurgical procedures when only a small amount of material is required to close a durotomy. The preparation time is minimal and easily accomplished by following the IFU. The Adherus Sealant has a set time of approximately 30 seconds from the time the reconstitution begins, allowing the surgeon enough time to properly place the material.

Set Time Adjusted For Specific Application In Conclusion Adherus Dural Sealant is safe and well tolerated, successfully creates a water-tight seal and eliminates CSF leaks. Stronger Requires less material Longer lasting Prevents late-forming pseudomenigocele Lower swelling Allows for use in confined spaces Anti-adhesion Minimizes dural adhesions and reduces scarring after healing Anti-microbial Controls infection Better clinical outcomes and shorter OR times. After a great surgery, why leave anything to chance? Adherus Dural Sealant is a synthetic, non-immunogenic hydrogel which seals the dura as it heals and provides a barrier to minimize dural adhesions and limit peridural fibrosis.