UroToday International Journal. Volume 4 - June 2011

Similar documents
UroToday International Journal. Volume 4 - February 2011

This information is intended as an overview only

Interventional procedures guidance Published: 12 October 2016 nice.org.uk/guidance/ipg566

I-STOP TOMS Transobturator Male Sling

SAFYRE TM : A READJUSTABLE MINIMALLY INVASIVE SLING FOR FEMALE URINARY STRESS INCONTINENCE

One Slim Needle One Incision. One Simple Solution for Stress Urinary Incontinence. The Difference is in the Data

UroToday International Journal. Volume 3 - October 2010

The Safety and Efficacy of a New Adjustable Single Incision Sling for Treatment of Female. Stress Urinary Incontinence Through 12-months of Follow-up

q7:480499_P0 6/5/09 10:23 AM Page 1 WHAT YOU SHOULD KNOW ABOUT YOUR DIAGNOSIS OF STRESS URINARY INCONTINENCE

ABSTRACT R.D. MOORE, D.O., F.A.C.O.G., F.A.C.S. DIRECTOR, ADVANCED PELVIC SURGERY DIRECTOR, UROGYNECOLOGY ATLANTA UROGYNECOLOGY ASSOCIATES ATLANTA, GA

Tension-free Vaginal Tape for Urodynamic Stress Incontinence

Urethrolysis; When, Why & How. M Karram Professor of Ob/Gyn & Urology University of Cincinnati

Nine-year experience in sub-urethral prosthesis for the treatment of female stress urinary incontinence

Operative Approach to Stress Incontinence. Goals of presentation. Preoperative evaluation: Urodynamic Testing? Michelle Y. Morrill, M.D.

Efficacy and Adverse Effects of Monarc Versus Tension-free Vaginal Tape Obturator: a Retrospective One-year Follow-up Study

Int Urogynecol J (2010) 21: DOI /s ORIGINAL ARTICLE Experience with TVT-SECUR sling for stress urinary incontinence: a 1

of UROLOGY Official Journal of the American Urological Association vwvw.jurology.com

Stress Urinary Incontinence in Women. What YOU can do about it...

Efficacy and Safety of the TVT-SECUR R and Impact on Quality of Life in Women with Stress Urinary Incontinence: A 2-Year Follow-Up

Mini Sling (Ophira) versus Pubovaginal Sling for Treatment of Stress Urinary Incontinence: A Medium-term Follow-up

New Insights in the Surgical Management of Stress Urinary Incontinence in Women

International Federation of Gynecology and Obstetrics

THE BULKING AGENT WITH LONG-LASTING EFFECT!

Trans-Obturator Tape Operation Using MONARC Technique (Outside-In Technique) --- Revisited Objective and Subjective Assessment

Midterm Prospective Evaluation of TVT-Secur Reveals High Failure Rate

Medical Policy Title: Radiofrequency ARBenefits Approval: 10/19/2011

A PATIENT GUIDE TO Understanding Stress Urinary Incontinence

Desara and Desara Blue

Blue Ridge Urogynecology

Desara TV and Desara Blue TV

Desara Blue OV D I. Sling for Female Stress Urinary Incontinence. Instructions For Use

Outpatient mid-urethral tissue fixation system sling for urodynamic stress urinary incontinence: 3-year surgical and quality of life results

Incidence and Risk Factors of Postoperative De Novo Voiding Dysfunction following Midurethral Sling Procedures

Stress Incontinence. Susannah Elvy Urogynaecology CNS

Treatment of Female Stress Urinary Incontinence by Trans-Obturaror Tension-Free Vaginal Tape (TVT-O): A Prospecive Controlled Study

Sep \8958 Appell Dmochowski.ppt LMF 1

Treatment Outcomes of Tension-free Vaginal Tape Insertion

Effect of Anesthesia on Voiding Function After Tension-Free Vaginal Tape Procedure

Sdefined as involuntary urine leakage

Medical Review Criteria Invasive Treatment for Urinary Incontinence

Impact of the Midurethral Sling Procedure on Quality of Life in Women with Urinary Incontinence

Current trend in anti-incontinence surgery

Pelvic artery embolization in the management of pelvic arterial bleeding following midurethral sling surgery for stress urinary incontinence

Advanced Care for Female Overactive Bladder & Urinary Incontinence. Department of Urology Kaiser Permanente Santa Rosa

Dynamic Evaluation of Pelvic Floor Reconstructive Surgery Using Radiopaque Meshes and Three-dimensional Helical CT

Stress Urinary Incontinence Surgery with Mini Sling Just-Swing System: Our Office Experience

Minimally invasive treatment for female stress urinary incontinence

AdVance Male Sling System

How to Achieve Long-Term Success in the Treatment of Female Urinary Stress Incontinence? Novel Modification on Vaginal Sling

What you should know about your diagnosis of incontinence

A.M.I. ATOMS System. Hydraulic system substitutes urinary sphincter function in incontinent males

Urodynamics in women. Aims of Urodynamics in women. Why do Urodynamics?

IUGA REGIONAL SYMPOSIUM December 12-13, 2011 Sao Paulo, Brazil Federal University of Sao Paulo PRELIMINARY PROGRAM. Regional

Department of Obstetrics and Gynecology, Faculty of Medicine, Minia University, Minia, Egypt

Elsevier Editorial System(tm) for Journal de Gynécologie Obstétrique et Biologie de la Reproduction Manuscript Draft

Prognostic value of urethral mobility and valsalva leak point pressure for female transobturator sling procedure

Transobturator tension free vaginal tapes: Are they the way forward in the surgical treatment of urodynamic stress incontinence?

Midurethral Slings for Women with Stress Urinary Incontinence

NATIONAL INSTITUTE FOR CLINICAL EXCELLENCE SCOPE. Urinary incontinence: the management of urinary incontinence in women

Voiding Dysfunction. Yoo Jun Park, Duk Yoon Kim. INTRODUCTION

A Simple Solution. to a Common Problem. Find relief from sudden, unplanned urine leakage.

Resolution of urge urinary incontinence with midurethral sling surgery in patients with mixed incontinence and low-pressure urethra

LONG TERM FOLLOW UP OF THE TRANSOBTURATOR TAPE PROCEDURE FOR THE TREATMENT OF STRESS URINARY INCONTINENCE IN A TERTIARY HOSPITAL IN SOUTH AFRICA

PUBOVAGINAL SLING IN THE TREATMENT OF STRESS URINARY INCONTINENCE FOR URETHRAL HYPERMOBILITY AND INTRINSIC SPHINCTERIC DEFICIENCY

Modern methods of imaging in urogynecology when do we really need them?

Stress urinary incontinence (SUI) is the urine leakage

Prediction and prevention of stress urinary incontinence after prolapse surgery van der Ploeg, J.M.

Avoiding Mesh Disasters: Tips and Tricks for Success and Handling Complications

To compare intermittent catheterization, sling mobilization and sling transection for treatment of

Karanvir Virk M.D. Minimally Invasive & Pelvic Reconstructive Surgery 01/28/2015

Predictors of Postoperative Voiding Dysfunction following Transobsturator Sling Procedures in Patients with Stress Urinary Incontinence

EUROPEAN UROLOGY 57 (2010)

Effects of the REMEEX System in Female Patients with Intrinsic Sphincteric Deficiency and Recurrent Urinary Incontinence: 3-Year Outcomes

Stress Urinary Incontinence in Women

Seventeen years follow-up of the tension-free vaginal tape procedure for female stress urinary incontinence

Efficacy and safety of a readjustable midurethral sling (Remeex system) for stress urinary incontinence with female voiding dysfunction

Tension-Free Vaginal Taping in Pakistani Women with Stress Urinary Incontinence

Rolled Vaginal Wall Flap for The Treatment of Stress Urinary Incontinence

Intraoperative Observation of the Degree and Pattern of Urine Leakage before Adjustment of the Mesh during a Transobturator Tape Procedure

1) What conditions is vaginal mesh used to commonly treat? Vaginal mesh is used to treat two different health issues in women:

Comparison of midurethral sling outcomes with and without concomitant prolapse repair

Only 15 years ago, when surgery was

Urogynaecology. Colm McAlinden

Long-Term Durability of the Distal Urethral Polypropylene Sling for the Treatment of Stress Urinary Incontinence: Minimum 11-Year Followup

TVT-O versus Monarc after a 2 4-year follow-up: a prospective comparative study

Tension Free vaginal tape. Mrs Ami Shukla, Consultant Urogynaecologist Northampton General Hospital Northampton NN1 5BD

Female Urology Evaluation of Transobturator Tension-free Vaginal Tapes in Management of Women With Recurrent Stress Urinary Incontinence

What the radiologists should know about US and MR findings of female urinary incontinence surgical tapes.

Risk Factors of Voiding Dysfunction and Patient Satisfaction After Tension-free Vaginal Tape Procedure

Contasure-Needleless single incision sling compared with transobturator TVT-O for the treatment of stress urinary incontinence: long-term results

Anatomical and Functional Results of Pelvic Organ Prolapse Mesh Repair: A Prospective Study of 105 Cases

Innovations in mesh kit technology for vaginal wall prolapse

Bard: Continence Therapy. Stress Urinary Incontinence. Regaining Control. Restoring Your Lifestyle.

Influence of Obesity on Short-term Surgical Outcome of the Transobturator Tape Procedure in Patients with Stress Urinary Incontinence

ig. 2. The organs and their outlet tubes.

Burch Colposuspension and Tension-Free Vaginal Tape in the Management of Stress Urinary Incontinence in Women

Both the middle and distal sections of the urethra may be regarded as optimal targets for outside in transobturator tape placement

Repeat midurethral sling treatment for prior midurethral sling failure

Transvaginal and Transurethral Radiofrequency Tissue Remodeling for Urinary Stress Incontinence

Urodynamic findings in women with insensible incontinence

Transcription:

UroToday International Journal Paulo Palma, 1 Cassio Riccetto, 1 Rodrigo Castro, 2 Sebastian Altuna, 3 Viviane Herrmann, 1 Ricardo Miyaoka 1 1 Division of Female Urology, State University of Campinas (UNICAMP), Campinas, Sao Paulo, Brazil; 2 Division of Urology, Federal University of Sao Paulo (UNIFESP), Sao Paulo, Sao Paulo, Brazil; 3 Austral University Hospital, Buenos Aires, Argentina Submitted March 18, 2011 - Accepted for Publication April 6, 2011 Volume 4 - June 2011 Safety and Efficacy of the Ophira Mini-Sling System: One-Year Follow-Up From a Multicenter International Clinical Trial ABSTRACT INTRODUCTION: The Ophira mini-sling system (Promedon; Cordoba, Argentina) uses a minimally invasive, midurethral low-tension tape that is anchored to the obturator internus muscles bilaterally at the level of the tendinous arc by a single vaginal incision. It minimizes surgical trauma and enables an outpatient procedure. Firstyear follow-up results are reported. METHODS: The study was a prospective clinical trial conducted from February 2008 to March 2010. Participants were 149 female patients with stress urinary incontinence from Brazil and Argentina. Their mean age was 53.9 years (SD = 9.5; range, 36-71 years). All patients received a medical history, physical examination, stress test, standardized 1-hour pad test, and urodynamic study. Patients also completed the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) and Urogenital Distress Inventory (UDI-6). All underwent treatment with the Ophira mini-sling system. The procedure was conducted under local (73%), general (18%), or regional anesthesia (9%). A vertical 1 cm long vaginal incision was performed at 1 cm from the urethral meatus to deliver the prosthesis. Patients repeated the presurgical tests at 1, 3, 6, and 12 months after surgery. Outcome measures were postvoid residual volume, pad and stress test results, ICIQ-SF and UDI-6 scores, and complications. Means and standard deviations were calculated and tabled. RESULTS: The mean (SD) operative time was 12.6 (7.4) minutes. One patient receiving the procedure under local anesthesia had severe intraoperative pain and needed intravenous sedation. Severe bleeding and technical problems with the device were not observed. The mean follow-up was 9 months; 91 patients had 12 months of follow-up evaluations. Postvoid residual volumes were variable across time. Pad tests showed less urine leakage after surgery. The percentage of patients with a positive stress test dramatically decreased after surgery. ICIQ- SF and UDI-6 scores also decreased. Major complications were not observed. Minor complications were mesh exposure (n = 3), urinary retention (n = 3), urinary tract infection (n = 8), and de novo urge incontinence (n = 7). CONCLUSIONS: The Ophira mini-sling system appears to be an effective, minimally invasive option for the treatment of stress urinary incontinence. KEYWORDS: Female urinary incontinence; Treatment; Minimally invasive surgery; Mini-sling CORRESPONDENCE: Dr. Ricardo Miyaoka, Rua Durval Cardoso, 172, Jardim Guarani, Campinas, Sao Paulo, Brazil (rmiyaoka@uol.com.br). CITATION: UroToday Int J. 2011 Jun;4(3):art 44. Abbreviations and Acronyms ICIQ-SF, International Consultation on Incontinence Questionnaire-Short Form SUI, stress urinary incontinence TOT, transobturator tape TVT-S, tension-free vaginal tape-secur UDI-6, Urogenital Distress Inventory UTI, urinary tract infection

Safety and Efficacy of the Ophira Mini-Sling System: One-Year Follow-Up From a Multicenter International Clinical Trial INTRODUCTION The Ophira mini-sling system (Promedon; Cordoba, Argentina) is an innovative anatomical approach for the management of female stress urinary incontinence (SUI) [1]. It involves anchoring a midurethral low-tension tape to the obturator internus muscles bilaterally at the level of the tendinous arc by a single vaginal incision. The rationale for the Ophira mini-sling procedure evolved from transobturator tape (TOT), which has proven to be as effective as the retropubic sling for the restoration of pubourethral ligaments and ureteropelvic fascia support [2]. It was developed in order to keep the optimal results of the transobturator sling through a multipoint fixation arm. This confers a stable primary fixation to the tissue, which adds safety and minimizes surgical and recovery time. The aim of this presentation is to report the first-year follow-up results of the use of the Ophira mini-sling system from an open international, multicenter prospective trial. METHODS The study was a prospective clinical trial that was conducted from February 2008 to March 2010. Participants were obtained from the State University of Campinas and the University of Sao Paulo in Brazil and Austral University Hospital in Argentina. The protocol was approved by a committee at Hospital de Clinicas, State University of Campinas. All participants provided informed consent. Participants The participants were 149 female patients with SUI. Their mean age was 53.9 years (SD = 9.5; range, 36-71 years); 94 patients (63%) were postmenopausal. The mean (SD) number of previous gestations was 2.9 (2.2). A total of 48 patients (32%) had previous anti-incontinence surgery. Their mean body mass index was 27.9 (4.4). The mean (SD) preoperative Valsalva leak point pressure was 78.2 cm H2O (27.1). Procedure Prior to surgery, all patients received a medical history, physical examination, stress test, standardized 1-hour pad test, and urodynamic study. Patients also completed the International Consultation on Incontinence Questionnaire-Short Form (ICIQ- SF) and Urogenital Distress Inventory (UDI-6). All patients underwent treatment with the Ophira mini-sling system. This system has a Type 1 polypropylene monofilament mesh that is held between 2 self-anchoring polypropylene arms with a multi-point fixation design (Figure 1). The device is connected to disposable retractable insertion guide during the procedure (Figure 2). The procedure was conducted under local anesthesia in 73% of the patients, using 10 ml of 2% lydocaine solution that was injected at the midurethra toward the vaginal fornix and Figure 1. Ophira mini-sling mesh (Promedon; Argentina) with anchoring fish-spine-like arms. doi: 10.3834/uij.1944-5784.2011.06.14f1 Figure 2. Ophira mini-sling kit (Promedon; Argentina) with suburethral mesh and delivering device. doi: 10.3834/uij.1944-5784.2011.06.14f2

Paulo Palma, Cassio Riccetto, Rodrigo Castro, Sebastian Altuna, Viviane Herrmann, Ricardo Miyaoka Figure 3. Three-dimensional helical computerized tomography showing the mini-sling in situ (posterior view). doi: 10.3834/uij.1944-5784.2011.06.14f3 Figure 4. Three-dimensional helical computerized tomography showing the mini-sling in situ (anterior view). doi: 10.3834/uij.1944-5784.2011.06.14f4 advanced 2 cm in the obturator internus muscles. The remaining patients had general anesthesia (18%) or regional anesthesia (9%), according to the anesthesiologist s decision. A vertical vaginal incision that was 1-cm in length was performed at 1 cm from the urethral meatus. Minimal dissection was performed laterally toward the ascending ramus of the ischiopubic bone to preserve the endopelvic fascia. For insertion of the implant, the retractable insertion guide was first connected to the multipoint fixation arm and then introduced toward the obturator internus muscle, 1 cm above the vaginal fornix. Insertion was guided by surgeon s index finger. When the centering mark of the implant was slightly underneath the right flap of the vaginal incision, the trigger at the handle was deployed to release the fixation arm in place (Figure 3; Figure 4). By design, the multipoint fixation arms provide strong and stable primary fixation [3]. The same maneuvers were repeated on the opposite side. After fine adjustments of the mesh, the retractable insertion guide was removed and the vaginal wall was closed in the usual manner. Cystoscopy was not mandatory. No Foley catheter was left in place. The patients were discharged immediately after spontaneous voiding. Follow-up Examinations and Data Analysis Patients repeated the presurgical tests at 1, 3, 6, and 12 months after surgery. The outcome measures were postvoid residual volume, pad test and stress test results, and ICIQ-SF and UDI- 6 scores. The means and standard deviations were calculated and tabled. Data were presented for patients at each follow-up test to show patterns of progression across time. Complications were also recorded. RESULTS Intraoperative outcomes. The mean (SD) operative time was 12.6 (7.4) minutes. Technical problems with the device were not observed. Three patients presented lydocaine hydrochloride overdose symptoms that were treated conservatively. Among the patients receiving the procedure under local anesthesia, 1 experienced severe intraoperative pain and needed intravenous sedation. None of the patients experienced severe intraoperative bleeding. Follow-up outcomes. Four patients were lost to follow-up. As of March 2010, the mean follow-up for the remaining 145 participants was 9 months; 91 patients had more than 12 months of follow-up. According to the definition of the Stamey Urinary Incontinence Scale, the dry rate was Grade 0 for 90.2% of the patients at the 1-year follow-up. Results of the presurgical and postsurgical follow-up evaluations are presented in Table 1. The postvoid residual volumes were variable across time. The pad tests showed less urine leakage after surgery. The percentage of patients with a positive stress test dramatically decreased after surgery. ICIQ-SF and UDI-6 scores also decreased.

Safety and Efficacy of the Ophira Mini-Sling System: One-Year Follow-Up From a Multicenter International Clinical Trial Outcome Measure Table 1. Results of the Presurgical and Postsurgical Follow-up Evaluations. doi: 10.3834/uij.1944-5784.2011.06.14t1 Presurgery (N = 149) a 1 month (n = 8) 3 months (n = 28) Postsurgery 6 months (n = 18) 12 months (n = 91) Postvoid residual urine, mean (SD), ml 3.0 (7.3) 6.3 (32.9) 1.0 (4.0) 0.9 (7.0) 1.4 (4.2) Pad test, mean (SD), g 13.1 (16.7) 2.7 (7.9) 2.3 (8.7) Postive stress test (%N) 96.5 0 7.8 12.5 9.8 ICIQ-SF score, mean (SD), score 0-21 17.0 (2.7) 3.2 (5.9) 2.7 (5.3) 4.3 (6.4) 2.9 (4.8) UDI-6 score, mean (SD), score 0-18 9.4 (2.9) 2.3 (2.8) 2.0 (2.6) 2.2 (2.7) 2.5 (3.0) a Four of these patients were lost to follow-up. Abbreviations: ICIQ-SF, International Consultation on Incontinence Questionnaire-Short Form; UDI-6, Urogenital Distress Inventory Postoperative complications. Complications such as infection, severe bleeding, or sexual dysfunction were not observed. Mesh exposure occurred in 3 patients (3.2%). It is worth noting that all 3 patients were asymptomatic and mesh exposure of < 0.5 cm was only detected by physical examination. The patients were treated by ambulatory resection of the exposed area (n = 1) and local estrogen ( n = 2). Four patients (4%) had urinary retention, which resolved spontaneously (n = 2), was treated with mesh excision (n = 1), and resolved within the first week by sling loosening (n = 1). Urinary tract infection and de novo urge incontinence were present in 8 patients (8.7%) and 7 patients (7.6%), respectively. DISCUSSION The concept of the arc to arc suburethral sling has been refined since its first description by Palma in 1999 [4]. A better understanding of the female pelvic anatomy and its functionality has allowed researchers to develop more efficacious and minimally invasive ways to correct urinary incontinence. The mini sling relies on maintaining the efficacy already proven for the traditional tension-free vaginal tape (TVT) and TOT suburethral slings, while trying to improve their side effects. In this sense, our data reinforce the efficacy of the mini slings when compared with data that have been reported with the traditional approaches. The operative time is notably shorter and the surgical procedure is feasible on an outpatient basis. Although we did not perform a detailed cost-effectiveness analysis, it seems obvious that the mini sling saves money because the hospital stay is shortened, fewer analgesics are necessary because patients do not complain of pain at the obturator nerve site that may be experienced with TOT slings, and minor complications are easily managed. Series with more than 12 months follow-up are reported, especially for the TVT-Secur (TVT-S) device (Ethicon; Somerville, NJ, USA). Meschia et al [5] conducted a prospective multicenter study and reported results from 91 patients. The patients had subjective and objective cure rates of 78% and 81%, respectively. Tartaglia and colleagues [6] reviewed 32 patients who underwent TVT-S implant and reported 100% dry rate at 12 months. However, it should be noted that cure rate was only subjectively accessed and patients with intrinsic sphincteric deficiency were excluded from the analysis. In a more recent report, Krofta and colleagues [7] prospectively analyzed 82 patients after TVT-S implant. At the 1-year follow-up, 43 (52.4%) women were objectively cured and 14 (17.1%) women were objectively improved. Subjectively, 49 (59.7%) patients did not experience urine loss and 18 (22.2%) women reported improvement in urine loss. The authors concluded that TVT-S provides inferior cure rates when compared with other tape procedures. In a larger series, Khandwala et al [8] reviewed 141 patients with TVT-S. They found no perioperative complication and had 1 case of urinary retention without the need for mesh release. Eighty five percent of patients were deemed satisfied on a subjective evaluation. The MiniArc single-incision sling (American Medical Systems; Minnetonka, MN, USA) is another prototype of the mini sling that is commercially available. Gauruder-Burmester and Popken [9] analyzed 97 women with either mixed or pure SUI that were treated with this device. Some of the participants (61.7%) had already undergone an initial attempt to correct their urinary incontinence. The cough test was negative in 77.8% of the participants at 12 months; a quality of life measure showed improvement in 69.1% of the participants. One patient had a pelvic hematoma and another had a bladder perforation. The

Paulo Palma, Cassio Riccetto, Rodrigo Castro, Sebastian Altuna, Viviane Herrmann, Ricardo Miyaoka authors concluded that the mini-sling approach is safe and effective. The majority of the current data support the idea that mini-sling techniques are able to create cure rates for female SUI that are comparable to the traditional retropubic or transobturator sling procedures, while being less invasive. However, a comparative head-to-head series involving both traditional slings and the more recent mini slings is desired in order to draw a more definitive conclusion. The present study is limited by its lack of a comparison group. In addition, not all of the patients in the present study had completed the 12-month follow-up and no statistical analyses were used to compare the presurgical and postsurgical data. CONCLUSIONS 6. Tartaglia E, Delicato G, Baffigo G, et al. Third-generation tension-free tape for female stress urinary incontinence. J Urol. 2009;182(2):612-615. 7. Krofta L, Feyereisl J, Velebil P, Otcenásek M, Kasiková E, Krcmár M. TVT-S for surgical treatment of stress urinary incontinence: prospective trial, 1-year follow-up. Int Urogynecol J Pelvic Floor Dysfunct. 2010;21(7):779-785. 8. Khandwala S, Jayachandran C, Sengstock D. Experience with TVT-SECUR sling for stress urinary incontinence: a 141-case analysis. Int Urogynecol J Pelvic Floor Dysfunct. 2010;21(7):767-772. 9. Gauruder-Burmester A, Popken G. The MiniArc sling system in the treatment of female stress urinary incontinence. Int Braz J Urol. 2009;35(3):334-343; author reply 341-343. The Ophira mini-sling system appears to be an effective option for the treatment of SUI. The device has reliable fixation and stability with the capability of being performed as an outpatient procedure. ACKNOWLEGEMENTS This manuscript was presented as a poster session at the 26th Annual Congress of the European Association of Urology, March 21 2011. Conflict of Interest: none declared. REFERENCES 1. Palma P, Riccetto C, Reges R, et al. Arcus to arcus microsling: technique and preliminary results. Int Urogynecol J Pelvic Floor Dysfunct. 2008;19(8):1133-1136. 2. Palma P, Riccetto C, Herrmann V, et al. Transobturator SAFYRE sling is as effective as the transvaginal procedure. Int Urogynecol J Pelvic Floor Dysfunct. 2005;16(6):487-491. 3. Palma P, Riccetto C, Siniscalchi C, et al. Primary fixation of mini slings: a comparative study in vivo. Int Urogynecol J Pelvic Floor Dysfunct. 2009;20(Suppl 2):S73. 4. Palma P. Sling tendineovaginal de pericardio bovino (técninca de Palma): Experiência inicial [Tendineouvaginal sling of bovine pericardium (Palma s technique): initial experience; Article in Portuguese]. J Bras Ginecol. 1999;109:93-97. 5. Meschia M, Barbacini P, Ambrogi V, Pifarotti P, Ricci L, Spreafico L. TVT-secur: a minimally invasive procedure for the treatment of primary stress urinary incontinence. One year data from a multi-centre prospective trial. Int Urogynecol J Pelvic Floor Dysfunct. 2009;20(3):313-317.