Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

Similar documents
SICvantage max Swiss Cross Technology

SIC invent. SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration

Implants from Implantologists. SIC invent Product Overview. SICvantage max. The Conical Connection. SICvantage Swiss Cross Technology

» For multi-unit restorations -

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

SIC invent. Product Overview. SICvantage max. The Conical Connection. SICvantage Swiss Cross Technology

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Product Overview Dental Implantat Systems Biomaterials

Locator retained mandibular complete prosthesis (isy Implant System)

4766 Research Dr. San Antonio, TX insightdentalsystems.com

isy indications and techniques

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Innovative Präzision Made in Germany

IMPRESSION PROCEDURES TRAINING MANUAL

NARROW DIAMETER implant

» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL MICROCONE. IPS Implant systems

User Manual Complete Prosthetic Kit (CPK)

» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL QUATTROCONE QUATTROCONE30. IPS Implant systems

Xive. Product Catalog

TITANIUM BASES CAD/CAM FOR CROWN AND BRIDGE RESTORATIONS CAD/CAM PROSTHETICS ON CAMLOG AND CONELOG IMPLANTS

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

Quick start Prosthetics

Cost-effective immediate restoration in the anterior region of the mandible (isy by CAMLOG)

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

ORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins

CHECK-UP Determination of Impression type & Method after implant placement

Ankylos. Product Catalog

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

The intelligent system.

High-end solution STEP-BY-STEP USER GUIDE

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

SS Implant System 2013 PROSTHETIC PROCEDURE

Implant Phase Flow Chart

OCCLUSALLY SCREW-RETAINED

TRINON. Index. Index. Overview Page 4. Catalogue

Innovative Präzision Made in Germany

prosthetic technique manual

BONE LEVEL ABUTMENTS. on4. multi-unit

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Straumann Screw-retained Prosthetics

SimpleLine II Surgical / Prosthesis Manual

The Uniti implant system is designed to be simple to learn and use. A seamless surgical protocol renders the system user friendly.

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

HEXAGON Implant System

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

SuperLine & Implantium Surgical / Prosthesis Manual

ANKYLOS Planning Components 100. ANKYLOS Implants 102. ANKYLOS Surgical Kits 103. ANKYLOS Surgical Unit, Handpieces 106

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

GMI FRONTIER implant system. Surgical procedures guide

Ankylos. Laboratory Manual

Guided surgery manual

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

NobelActive. Quick start page 5. Surgical procedures page 8. Prosthetic procedures page 28. Appendix IV cleaning and. sterilization page 66

Basic information on. Fixed edentulous solutions Treatment guide

Immediate fixed teeth a treatment concept for edentulous patients

Legacy Prosthetic Catalog

SuperLine & Implantium Surgical / Prosthesis Manual

Implant Restorations: A Step-By-Step Guide

Basic information on the. surgical procedures. Straumann Dental Implant System

CAMLOG IMPLANT SYSTEM PRODUCT CATALOG

Replacement of a missing posterior tooth in the mandible (isy by CAMLOG)

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

- RESTORATIVE PRODUCT CATALOG

DIGITAL DIAGNOSIS AND TREATMENT PLANNING FOR PLACEMENT AND RESTORATION OF SINGLE IMPLANTS IN THE POSTERIOR MAXILLA By Timothy Kosinski, DDS

Fixed Restoration for Atrophic Ridges

TS Implant System 2013 PROSTHETIC PROCEDURE

PRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014

Trefoil Procedure manual

Straumann Dental Implant System Basic Information. Technical Information

Basic Information on Straumann Guided Surgery. Straumann Dental Implant System

» QuattroFix treatment concept by MEDENTIKA «

Astra Tech Implant System. Manual and product catalog. Guided surgery. Computer guided implant treatment with the Astra Tech Implant System EV

The REAL Mini Implant

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

Product Catalog. Since 1985» Simple. Predictable. Profitable.

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

NARROW DIAMETER implant

Single tooth crowns 48 Fixed solutions for larger tooth gaps and the edentulous jaw 68 Removable solutions for the edentulous jaw 88

INTERNAL HEX Implant System

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

US Implant System 2013 PROSTHETIC PROCEDURE

Innovative Präzision Made in Germany

The Use of Alpha-Bio Tec's Narrow NeO Implants with Cone Connection for Restoration of Limited Width Ridges

Prosthodontic Procedure

GMI. MONOLITH implant system. Surgical procedures guide

DENTI BONE LEVEL TWO STAGE IMPLANT SYSTEM

Extraction with Immediate Implant Placement and Ridge Preservation in the Posterior

CAD/CAM Prosthetic Solutions

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

a perfect fit CAMLOG IMPLANT SYSTEM PRODUCT CATALOG CAMLOG IMPLANT SYSTEM PRODUCT CATALOG SEPTEMBER 2014

Personal Attention Accurate Dental Solutions. Precision Down to the Smallest Detail. Wide Range of Dental Solutions Engineerd for a Lifetime

Hex-Lock Abutment System. Restorative Manual

Transcription:

Multi-Unit Abutment System SIC Safe on Four Optimum use of available bone by angled placement of implants

Multi-Unit Abutment System SIC Safe on Four Safe on Four The SIC Safe on Four system is a further development of the bar and bridge abutments system. In the Safe on Four system, the bar and bridge abutments and the Safe on Four angled standard abutments are directly screw retained with the respective implant. In this way, a fixed transgingival platform is created over which all further prosthetic and laboratory technical measures are completed. The system is indicated for fixed or removable bridge or full restorations with the stipulation that the distal implants can have a maximum implantation angle of 30. The maximum bone availability is utilised distally by displacement of the most distally placed angled implant. During development of the system, particular value was placed on the greatest possible stability of individual components. The straight bar and bridge abutments consist of a two-part design which includes an abutment component with hex and a Safe on Four fixation post that, using the long screw shank, ensures maximum continuous loading capacity. The Safe on Four universal fixation screws also have a reinforced screw thread. Bridgework Fixation Screw Safe on Four with reinforced thread M 1.6 mm Complete Restoration non-removable Complete Restoration removable Centring fit between post and abutment Precision hexagon provides a reliable implant / abutment connection with maximum stability Long screw shaft with maximum fatigue limit 2 )

SIC Multi-Unit Abutment Product Properties at a Glance: Anterior bar and bridgework abutments, 2 part and highly stable Distal abutments, 16 and 30 angled Abutment cone 28, 3.4 mm high and 5.0 mm in diameter Standardised occlusal screw, M 1.6 Special surgical instruments: Ø 5.2 mm cutter for determining the level of the implant and removing excess distal bone. (Also for use during SIC Guided Surgery) 30 Ncm 20 Ncm General Guidelines for SIC Safe on Four Restorations: The generally accepted rules and recommendations for dental implantology also apply here. For complete restorations a minimum of four implants must be placed in the mandible and a minimum of six in the maxilla. The bone quality must be D3 or higher. The implants must exhibit an intraosseous length of at least 9.5 mm and angled implants 11.5 mm. The implant diameter should be as large as possible minimum: 4.0 mm. The implant should be placed at 16 resp. 30. In case of immediate placement or immediate loading to ensure adequate primary stability the placement torque must be between 30 and 40 Ncm. The secondary parts (crown bases) must be firmly splinted primarily and distal extensions should generally be avoided. Comprehensive diagnosis and patient counselling as well as preoperative planning are essential. CT or CBCT planning is useful for determining the locations of the anatomical structures. The opposing dentition and general patient-specific risk factors must be given special attention. The operator must be sufficiently competent in surgery and prosthetics. 30 35 to 45 16 16 to 35 2 to 30 0-14 to 14

SIC Safe on Four Surgical Guideline angle Planning Guide Pre-Drill Pilot Drill 2.0 mm straight Planning Guide Pre-Drill Pilot Drill 2.0 mm GH distal GH mesial Planning Overview: Safe on Four Gingival height [mm] mesial/distal Ø Implant connection [mm] Ø 3.3 Ø 4.2 Angulation [ ] 0 16 30 0 16 30 GH 1.5 mm 1.5 1.5 /2.4 0.9 / 3.4 1.5 1.5 /2.4 1.5 /2.4 GH 3.0 mm 3.0 2.6 /4.1 3.0 2.7/4.1 2.7/5.4 1 Planning Guide: The planning guide is used for visual and three-dimensional orientation of the implant angulation (mesial/distal) and oral parallelisation. The template is easily bent to adapt it to the dental arch and secured by means of a Ø 2.0 mm pilot drilling in the symphysis and pin in the jaw. The slider is used to position the template for drilling and the sites drilled according to the surgical protocol. Each drill is aligned parallel to the template surface and at the implantation angle. 2 Marking Drill: Once the mucous membrane has been raised, the implant site is indented with a marking drill. The drilling depth can be varied but must not exceed the length of the implant. Speed: max. 800 rpm. 3 Pilot Drill: The Ø 2.0 mm pilot drill is used for determining the implant length and axial alignment. The implant site can be drilled to the required depth by either viewing the depth markings on the drills or using the optional stop system. Speed: max. 800 rpm. 4 )

When placing angled implants the cutter widens the distal bone and thereby creates space for abutments to be placed later. Cutter 5.2 mm Extension Drill Implant Insertion Positioning Aid Extension Drill Implant Insertion 4 Cutter: The levelling cutter levels the alveolar ridge. When placing angled implants, the cutter widens the distal bone to create space for placing the abutments later. During surgery, the guidance lug of the levelling cutter follows the Ø 2.0 mm pilot drilling. The cutting depth is variable and defines the level of the implant shoulder. Speed: less than 500 rpm. When using SIC Guided Surgery, the laser marking defines the depth of insertion at 1 mm. 5 Extension Drill, Crestal Drill and Bone Tap: Which SIC extension drill and crestal drills are used depends on the diameter of the implant planned for use (refer to the surgical guidelines). Speed: less than 500 rpm. In cases with very hard bone structures (D1/D2) the thread should be pre-tapped. The thread should normally be tapped to a depth of half the length of the implant. The thread can either be tapped manually or power-driven. Speed: max. 35 rpm. (We recommend a lower speed for each of the final extension drillings and with the crestal drill. At speeds lower than 60 rpm., external cooling with cooled, sterile physiological saline solution [NaCl] or Ringer s solution is not necessary.) 6 Implant Placement: The implants may be wound in power-driven or manually. The implant should be placed flush with the bone surface. Speed: max. 25 rpm. 7 Positioning Aid: When using the Safe on Four technique, the final position of the implant must always be aligned so that one corner of the outer hex on the insertion tool or the implant insertion post faces buccal aspect. Final adjustment of angled implants is carried out with the positioning aid. First, the pointer is placed at the 16 or 30 position depending on the angle of implantation. The implant can then be aligned so that in the oral direction the pointer is vertical and parallel to the other implant axes. Align bucally ( 5

Submerged healing Healing Transgingival In cases of transgingival healing and late restoration, healing takes place over the abutment and gingiva shaper. Immediate restoration Impression-taking closed repositioning technique Master Model 6 ) 8 Healing: Finally, implant closure is carried out submerged with the cover screw or transgingivally via the appropriate abutment depending on the treatment plan and resulting in saliva-proof wound closure. Torque values: Implant Cover screw: All fixation screws with HEX 1.2: Fixation posts for Safe on Four : Hand tight approx. 5 7 Ncm 20 Ncm 30 Ncm (with the HEX 3.0 implant insertion tool) 9 Impression-taking Once the healing phase is over, an impression is taken of the implant positions either transgingivally or with the functional cone of the abutment using the open tray technique or closed repositioning technique. The fixation screws of the transfer abutments are easy to operate. They are secured against losing. Sub sequently the master model is fabricated.

10 Prosthetic Restoration: A multitude of options are available for prosthetic restoration. Titanium crown bases can be adhered into existing coverdentures to create temporary restorations. Superstructure frameworks can be fabricated with non-precious or high-fusing alloy crown bases. CAD/CAM bars or bridges. A Titanium crown bases adhered into a temporary full denture The temporary full denture is relieved generously around the titanium adhesive bases before adhering them passively either in-vitro or orally in-vivo. B Definitive placement of a bridge on two posterior implants The metal framework is trimmed adequately in the region of the titanium adhesive bases before being adhered passively either in-vitro or orally in-vivo. An additional option involves fabricating the framework using directly cast-on, high-fusing or non-precious alloy adhesive bases. Following veneering and final finishing, the bridge is screwed into place passively from the occlusal aspect using the SIC Safe on Four fixation screws. This procedure is also suitable for fabricating a definitive full restoration supported on four upper implants or six lower implants, as described in example 1. C Bar supporting a removable full restoration The Safe on Four abutments are either splinted with a cast, custom milled bar or primarily and passively as described in the example of a CAD/CAM bar. The definitive removable resto ration can then be fabricated depending on the indication and patient s wish and in accordance with the appropriate retention unit or lock. ( 7

SIC invent Product Multi-Unit Abutment System 936253 SIC Bar and Bridge Abutment Safe on Four Ø 3.3 mm, GH 1.5 mm 1 936254 SIC Bar and Bridge Abutment Safe on Four Ø 3.3 mm, GH 3.0 mm 1 936255 SIC Bar and Bridge Abutment Safe on Four Ø 4.2 mm, GH 1.5 mm 1 936256 SIC Bar and Bridge Abutment Safe on Four Ø 4.2 mm, GH 3.0 mm 1 1 incl. SIC Fixation Post Safe on Four, GH 1.5 mm 936259 SIC Standard Abutment Safe on Four Ø 3.3 mm, 16 angle, GH 1.5 mm 2 936261 SIC Standard Abutment Safe on Four Ø 3.3 mm, 16 angle, GH 3.0 mm 2 936260 SIC Standard Abutment Safe on Four Ø 3.3 mm, 30 angle, GH 1.5 mm 2 936263 SIC Standard Abutment Safe on Four Ø 4.2 mm, 16 angle, GH 1.5 mm 2 936262 SIC Standard Abutment Safe on Four Ø 4.2 mm, 16 angle, GH 3.0 mm 2 936264 SIC Standard Abutment Safe on Four Ø 4.2 mm, 30 angle, GH 1.5 mm 2 936265 SIC Standard Abutment Safe on Four Ø 4.2 mm, 30 angle, GH 3.0 mm 2 1 incl. SIC Fixation Post Safe on Four, GH 1.5 mm 936252 SIC Gingiva Shaper Safe on Four, cylindrical 936275 SIC Transfer Abutment Safe on Four, open tray technique (incl. SIC Fixation Screw 16.0 mm) 936541 SIC Fixation Screw Safe on Four 16.0 mm, for Transfer Abutment, Open Tray Technique 936250 SIC Transfer Abutment Safe on Four, reposition (incl. SIC Transfer Cap with Click) 936276 SIC Crown Base Safe on Four, residue-free burn-out (incl. SIC Fixation Screw Safe on Four ) 936270 SIC Crown Base Safe on Four, Titanium (incl. SIC Fixation Screw Safe on Four ) 936272 SIC Crown Base Safe on Four, high fusing alloy (incl. SIC Fixation Screw Safe on Four ) 936273 SIC Crown Base Safe on Four, for non-precious alloy (incl. SIC Fixation Screw Safe on Four ) 936274 SIC Bar Coping Safe on Four (incl. SIC Fixation Screw Safe on Four ) 936271 SIC Scan Adapter for SIC Safe on Four 936280 SIC Positioning Aid 16 and 30 for SIC Safe on Four 936281 SIC Planning Guide for SIC Safe on Four 936257 SIC Fixation Post Safe on Four, GH 1.5 mm 936258 SIC Fixation Post Safe on Four, GH 3.0 mm 936540 SIC Fixation Screw Safe on Four 936529 SIC Fixation Screw, short 935230 SIC Cutter Ø 5.2 mm for SIC Safe on Four, with Guidance Tip 936251 SIC Lab Implant Safe on Four 936682 SIC Standard Bar, round, Ø 2.0 mm, 50 mm, gold 936683 SIC Bar Clip, 50 mm, gold 2/2018 SIC invent AG Birmannsgasse 3 CH-4055 Basel Tel.: +41 (0)61 260 24 60 Fax.: +41 (0)61 261 39 68 contact.switzerland@sic-invent.com SIC invent Deutschland GmbH Willi-Eichler-Strasse 11 37079 Göttingen Tel.: 0800 742 46 83 68 Fax: 0800 74 23 29 38 contact.germany@sic-invent.com SIC invent Austria GmbH Kohlmarkt 7/Stg. 2/58 A-1010 Wien Tel.: +43 (0)1 533 70 60 Fax.: +43 (0)1 533 70 60 50 contact.austria@sic-invent.com SIC invent Asia Pacific Inc. 6F, Hyojin Bldg., 1540-5 Seocho-dong, Seocho-gu, Seoul, 137-070, Korea (ROK) Tel.: +82 2 585 9700 Fax.: +82 2 584 4411 contact.korea@sic-invent.com www.sic-invent.com www.my-sic.com