IRRADIATORS. September 11, :00 am-5:00 pm Hock Plaza Auditorium Duke University Medical Center, Erwin Road

Similar documents
Dosimetry comparison of orthovoltage x-ray and 137 Cs irradiation of the murine bone marrow compartment Matthew Belley

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

Neutron Interactions Part 2. Neutron shielding. Neutron shielding. George Starkschall, Ph.D. Department of Radiation Physics

1 Course Syllabus + Study Guide for Lecture and Laboratory

Course Syllabus + Study Guide for Lecture and Laboratory

Using Monte Carlo Method for Evaluation of kvp & mas variation effect on Absorbed Dose in Mammography

GATE MONTE CARLO DOSIMETRY SIMULATION OF MARS SPECTRAL CT

DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA

The impact of SID and collimation on backscatter in radiography

Dosimetry in digital mammography

Radiologic Units: What You Need to Know

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Investigation of the clinical performance of a novel solid-state diagnostic dosimeter

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

Skyscan 1076 in vivo scanning: X-ray dosimetry

Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital

Bone Densitometry Radiation dose: what you need to know

Table of Contents. Introduction 3. Background 4

SAXS on lipid structures

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

Radiation Detection and Measurement

Cone Beam CT Protocol Optimisation for Prostate Imaging with the Varian Radiotherapy OBI imaging system. Dr Craig Moore & Dr Tim Wood

Current Status of Electronic Brachytherapy Dosimetry

Standardization of dosimetry practices for small and large animal irradiation in radiobiological studies

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Radiology Positioning Practical Test #2 Table (By Jung Park):

X-RAYS INDIVIDUAL DOSE ASSESSMENT USING TLD DOSIMETERS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Electron therapy Class 3: Clinical procedures

Medical Physics 4 I3 Radiation in Medicine

Neutron dose evaluation in radiotherapy

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Austin Radiological Association Ga-68 NETSPOT (Ga-68 dotatate)

Dosimetric Consideration in Diagnostic Radiology

Dental Intraoral X-ray Systems

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Radiography. 1. Introduction. 2. Documentation of Compliance. 3. Didactic Competency Requirements. 4. Clinical Competency Requirements

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

THE HIGH-CURRENT DEUTERON ACCELERATOR FOR THE NEUTRON THERAPY. S.V. Akulinichev, A. V. Andreev, V.M. Skorkin

Radiation Safety Information for Students in Courses given by the Nuclear Physics Group at KTH, Stockholm, Sweden

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

Adult: > 18 Years ALARA: As low as reasonably achievable ALI:

Radiotherapy. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

CHARACTERIZATION OF THE ELECTRON BEAM RADIATION FIELD BY CHEMICAL DOSIMETRY

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

Improving personal dosimetry of medical staff wearing radioprotective garments: Design of a new whole-body dosimeter using Monte Carlo simulations

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

Manik Aima, Larry A. DeWerd, Wesley S. Culberson

Application(s) of Alanine

Skeletal System Tour Lab. Station Label the bones on your answer sheet.

Frank: Merrill's Atlas of Radiographic Positioning & Procedures, 12th Edition

45 Hr PET Registry Review Course

Radiation Safety in the Catheterization Lab

Application of dose-area product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology

Model 3500 Manual TLD Reader with WinREMS 3500-W-O-0602 Page 5-1 Operator's Manual

CALCULATION OF BACKSCATTER FACTORS FOR LOW ENERGY X-RAYS USING THE TOPAS MONTE CARLO CODE

Shielding Calculation: Radiographic Room. Jerry Williams

ORAU Team Dose Reconstruction Project for NIOSH

GAFCHROMIC MD-55 RADIOCHROMIC DOSIMETRY FILM FOR HIGH-ENERGY PHOTONS CONFIGURATION, SPECIFICATIONS AND PERFORMANCE DATA

Diode calibration for dose determination in total body irradiation

Basic radiation protection & radiobiology

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2017

Computed tomography Acceptance testing and dose measurements

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Reduction of Radiation Exposure during Radiography for S coliosis

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

Radiochromic film dosimetry in water phantoms

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Radiation Dosimetry in Digital Breast Tomosynthesis. March, 2015 William J. O Connel, Dr. Ph, Senior Medical Physicist

Radiation Safety for New Medical Physics Graduate Students

Routine Guide EXAMINATION PROJECTION CASSETTE SIZE NOTES PRINT ORIENTATION. 14x17 CW* 14x17LW 14x17LW. 14x17LW 14x17LW 14x17LW

RADIATION SAFETY. Junior Radiology Course

Medica Health Plans. Minnesota Fee Schedule Revised 5/1/2016 NEW PATIENT EXAMS: MN Medicaid. Medicare

LECTURE 13. Dr. Teresa D. Golden University of North Texas Department of Chemistry

ARRT Specifications Radiation Exposure & Monitoring

THERMOLUMINESCENT (TL) DOSIMETRY OF SLOW-NEUTRON FIELDS AT RADIOTHERAPY DOSE LEVEL

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

Commissioning and Radiobiology of the INTRABEAM System

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Patient Management Image Selection Radiation Biology, Dosimetry & Protection

Prof. Dr. Doğan BOR Ankara University Institute of Nuclear Science

DENTAL RADIOLOGY Identify basic facts and terms of radiology, to include fundamentals. with 70% accuracy.

X-Ray & CT Physics / Clinical CT

Douglas J. Simpkin, Ph.D. Aurora St. Luke s Medical Center Milwaukee, Wisconsin. www.

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

Theragnostics for bone metastases. Glenn Flux Royal Marsden Hospital & Institute of Cancer Research Sutton UK

Module Rhodes

Radiation Safety For Anesthesiologists. R2 Pinyada Pisutchareonpong R2 Nawaporn Sateantantikul Supervised by Aj Chaowanan Khamtuicrua

Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Country Health SA Medical Imaging

PATIENT ENTRANCE SKIN DOSES AT MINNA AND IBADAN FOR COMMON DIAGNOSTIC RADIOLOGICAL EXAMINATIONS

Why is CT Dose of Interest?

Y FILMS DOSIMETR Nederland België / Belgique

Transcription:

IRRADIATORS Terry Yoshizumi,, PhD September 11, 2006 8:00 am-5:00 pm Hock Plaza Auditorium Duke University Medical Center, Erwin Road Radiation Countermeasures Center of Research Excellence 1

Acknowledgements Sam Brady Garrett Muramoto John Chute Giao Nguyen Greta Toncheva Lauren Daigle Dave Jorgensen Greg Egan Netiti Moori Brad Thrasher Beverly Steffey Oana Craciunescu 2

X-ray irradiator Production of x-rays x (bremsstrahlung) How the x-ray x machine works Bremsstrahlung X-ray spectrum Factors affecting dosimetry Case study (John Chute) 7

Production of x-rays x (bremsstrahlung( bremsstrahlung) Charged particle (e.g., electron) passing near a nucleus may be deflected by the strong electrical forces exerted on it by the nucleus As the projectile electron passes by the nucleus, it slows down, changes its course, and leaves with reduced kinetic energy. This loss in kinetic energy reappears as an x-ray x (called bremsstrahlung x-rays) 8

How the x-ray x machine works X-ray tube Removable filter AGFA X-RAD 320 9

ANATOMY OF ANODE TUBE Melting point 1083 deg C Z=74, High melting point 3380 deg C 10

TUBE VOLTAGE AND TUBE CURRENT Tube voltage (kvp) Tube current 11

CATHODE ASSEMBLY Small filament for high-resolution imaging Larger filament for higher intensities (large ma) 12

TARGET ANGLE AND DIRECTION OF BREMSSTRAHLUNG Target angle Target angle 10-20 degrees Direction of bremsstrahlung radiations (approx. perpendicular to the direction of electrons) See next slide 13

RELATIVE INTENSITY OF BREMSSTRAHLUNG For low energy electrons, radiated predominantly at right angle to the motion of the particles The probability of bremsstrahlung production varies with Z 2 of the absorbing materials 14

Bremsstrahlung x-ray spectrum Max. kvp 15

FILTERS, AND BEAM RESTRICTORS # types of filters # 1 # 4 # 8 #1: 1.65 mm Aluminum #4: 0.1 mm Cu + 2.5 mm Al #8: 0.8 mm Tin + 0.25 mm Cu +1.5 mm Al 16

Key factors affecting dosimetry X-ray energy (kvp( kvp) Tube current (ma( milliamperes) Beam filtration (filters) Distance Attenuation in mouse Backscatter as a function of field size 17

Factors affecting dosimetry X-ray energy (kvp( kvp) Rule of Thumb (dose increases to kvp 2 ) Dose Dose kvp ( ) kvp 2 2 1 1 2 2 Dose 2 Dose 1 ( ) kvp1 2 kvp Example: 120 kvp to 140 kvp Dose 140 kvp ~Dose 120kVp * (140/120) 2 = 1.36* Dose 120kVp i.e., Dose increases by 36%. 18

19

Factors affecting dosimetry Tube current (ma( milliamperes) A change in ma results in a directly proportional change in the amplitude of the x-ray x emission spectrum at all energies. Example: if you double the ma from 200-mA to 400-mA, the area under the curve (x-ray quantity) doubles. 20

Factors affecting dosimetry Effects of beam filtration (filters) Available filters #1: 1.65 mm Aluminum #4: 0.1 mm Cu + 2.5 mm Al #8: 0.8 mm Tin + 0.25 mm Cu +1.5 mm Al 21

Factors affecting dosimetry Effects of beam filtration (filters) The overall result of added filtration is an increase in the effective energy of the x-ray x beam with an accompanying reduction in x-ray x quantity. Peak energy shift 22

#4 filter being used in Sands Building #4 filter #1 filter #8 filter #1: 1.65 mm Aluminum #4: 0.1 mm Cu + 2.5 mm Al #8: 0.8 mm Tin + 0.25 mm Cu +1.5 mm Al 23

Factors affecting dosimetry Effect of distance (source-to to-surface distance, SSD, or target (focal spot)-to to surface distance, TSD) Inverse-square square law (dose decreases inversely to the square of the distance) Example: 4Gy *(50cm/100cm) 2 = 4Gy*(1/4)=1 Gy 24

X-ray geometry- mouse Hummm I feel more heat! Dose depends on the source-to-mouse (target) distance. The closer to the tube, 25 the higher the dose.

Factors affecting dosimetry Attenuation in mouse For 135 kvp expect some attenuation in the mouse Backscatter as a function of field size 26

John Chute, PI Objectives CASE STUDY Compare absorbed dose between clinical protocol and direct TLD method Clinical protocol used by Garrette: : Parameters: 135kVP, 22mA, @ 100cGy/min, FS (collimated beam): 20 cm x 20 cm 27

Mouse Anatomy % Bone Marrow Skull:17.6% Mandible:2.0% Clavicle and Scapula: 1.0% Spine: 33.7% Cervical: 4.2% Thoracic: 7% Lumbar: 9.9% Sacral:8.1% Coccygeal: 2.3% Humerus:2.4% Forearm:0.7% Sternum:3.8% All Ribs:5.0% Femur: 5.8% Tibia: 3.0% Pelvis:11.9% Mus musculus (Common species of Lab mouse): -Avg overall length: 16.9cm (head to tail) -body length: 6-10cm (head to base of tail) -hind foot: 1.8cm -Avg weight adult mouse: 17-25g -Average height: 3-5cm 28

TISSUE-EQUIVALENT EQUIVALENT MOUSE PHANTOM A B C TLD 15, 16 TLD 13, 14 TLD 11, 12 1 cm 0.3 cm 0.6 cm 2.0 cm 3.8 cm 2.7 cm 3.8 cm 2.4 cm 3 cm 12 cm A B C TLD chips (3 mm x 3 mm x 1 mm thick) 29

Results: x-ray x irradiator Dose rate suspicious LOCATION A (Head) 1 cm deep CLINICAL SETTING 100 cgy/min 500 cgy TLD MEASURED DOSE 406.79 + 15.61 cgy % DIFF -23% B (Middle) 0.3 cm deep 500 cgy 427.07 + 37.23 cgy -17% C 0.6 cm deep 500 cgy 441.36 + 6.12 cgy -13% 30

Clinical Setting 500 cgy X-ray Mouse Dose (cgy) Dose (cgy) 500.00 400.00 300.00 200.00 100.00 0.00 406.79 427.07 441.36 A (1.0 cm) B (0.3 cm) C (0.6 cm) TLD locations 31

New Calibration factors for Garrett geometry Location A Dose Rate (cgy/min) 81.1 SD Dose Rate (cgy/min) 3.1 B 85.4 7.4 C 88.3 1.2 AVERAGE 85.0 2.7 32

Why mice did not die? Time (min) Clinical DR used (100 cgy/min) New DR (85.0 +/- 2.7 cgy/min) % Diff 7 700 595.1 +/- 19.1-18% Target 700 cgy was actually 595 +/- 19 cgy. 33

50 cm cgy d cm min Desired Dose (cgy) 50 cm cgy d cm min 2 Desired Dose (cgy)=( ) x DR ( ) x T(min) T(min) = 2 ( ) x DR ( ) STD=50 CM d cm B A Dose Rate (DR) in cgy/min 34

GEOMETRY STD=50 cm B: 44.2 cm 46.5 cm A: STD=45.5 cm 4.8 cm 1 cm below 2 cm 3 cm 3.5 cm 0.5 cm deep STD=45.5 cm 35

Results of mice dosimetry x-ray irradiator LOCATION B: Assume source- to-target target distance =44.2 cm A: Assume source-to to- Target distance =45.5 cm Dose rate being used clinically by Chute group Dose rate 95.0 cgy/min 100.7 cgy/min 100 cgy/min Dose for 5 min exposure 475.18 cgy 504 cgy 500 cgy 36

Discussions Sources of inaccuracies Look-up table (BSF)- probably minor Geometry changed since originakl calibration (major) Scatter geometry different in mice in the plastic holder (not uniform water phantom) 37

Gamma ray irradiator JL Shepherd Mark I 38

Gamma ray irradiator Decay scheme (Cs-137) Key differences from X-rayX Case study Quality assurance note 39

Decay scheme (Cs-137) Half-life= life= 30 yrs Emits β 1 particles (electrons) Gamma at 662 kev + - n p + e + γ + energy 137 137 0 55 56-1 Cs Ba + β + ν + γ 137 137 0 55 56-1 Cs Ba + β + ν + γ 40

Key differences from X-ray X irradiator Energy: Cs-137 662 kev X-ray 135 kvp (ave.. energy ~45 kev) (average energy ~135 * 1/3= 45 kev) Need for annual decay correction for Cs-137 0.693 1 yr -λ*t - 30 yr = e = e 0.977 The dose rates must be decreased 2.3% per year. 41

Cs-137 Irradiator Dimension 37 cm high Cs-137 source will be raised Turntable 30 cm diam. 42

Cs-137 Irradiator (Chute) 4.8 cm 3 =7.6 cm rotating table 43

Factors affecting dosimetry Non-uniform irradiation of mice due to rotating table Dose rate point taken at central point and assume same dose distribution (not true) 44

CASE STUDY John Chute, PI Objectives Compare absorbed dose between clinical protocol and direct TLD method Exposure T=0.76 min Target dose =500 cgy 45

Geometry issues need to be addressed TLD chips Beam angle and TLD chip angle dependency The beam not always perpendicular to the chips Θ Cs-137 source Goals: Understand angle dependency Minimize angle effects in dosimetry 46

8/15/2006 TLD runs:cs-137 geometry TLD chip 3 x 3 x 1 mm #3 #1 Beam direction TLD perpendicular, middle #2 #2 TLD parallel to beam, middle #1 rotation #3 TLD parallel to beam, top, same as x-ray 47

CLINICAL PROTOCOL DOSE SET TO 500 cgy Set-up #1 Gold Standard (TLD Cs-137) 600.00 500.00 448.39 430.45 474.52 451.12 400.00 300.00 200.00 100.00 0.00 A B C average A B C 48

Geometry #2, target dose =500 cgy #2 TLD parallel to beam, middle Case #2 600.00 500.00 443.52 496.59 457.95 466.02 dose (cgy) 400.00 300.00 200.00 100.00 0.00 A B C average 49

Case #3: x-ray x geometry, Target 500 cgy A B C TLD 15, 16 TLD 13, 14 TLD 11, 12 #3 TLD parallel to beam, top, same as x-ray 1 cm 0.3 cm 0.6 cm 2.0 cm 3.8 cm 2.7 cm 3.8 cm 2.4 cm 3 cm 12 cm Case #3: x-ray geometry Dose (cgy) 500.00 480.00 460.00 440.00 420.00 400.00 465.32 429.90 474.10 456.44 380.00 360.00 A B C average 50

New calibration factors for Garrett geometry geometry DR (cgy( cgy/min) SD (cgy( cgy/min) #1 (middle, gold standard) #2 (middle) 593.6 613.2 12.8 12.6 #3 (spine curve) 600.6 10.6 51

Irradiator Dosimety Quality Assurance Note Whenever set-up changes, consult your physicists (Oana( and Beverly, Rad Onc or Radccore HP group) Geometry specific direct measurements would improve confidence and accuracy Calibration factors for specific geometries may be posted in the web-site Dose validation is important across the Radccore affiliates 52

Irradiator safety issues 54

Irradiator safety issues Don t t lose your fingers Understand radiation levels in normal operations 55

Radiation level under normal operations X-ray beam on 8 µr/hr @ 1 9 µr/hr @ 2 Assume 10 min exposure @ 1 ft, then Cs-137 Source off µ R R 1 hr hr 10 µr 60 min -6 Dose equivalent ( Rem ) = 8 * *10 min * = 1.3 x 10 R (or Rem) 6 Recall WB limit = 5 Rem per yr No radiation risks! 56

Cs-137 source up A location A B C D waist level 3-ft high (1 ft away from wall) ur/hr 130 80 300 130 B A D At A, 5 x 10-5 Rem for 10 min exposure (Annual limit = 5 Rem) C 57

Safety Summary Watch your fingers! Under normal operating conditions, no radiation risks exist. 58