Elemental Scientific. seafast S2. Elution Profiles. Elemental Scientific

Similar documents
Elemental Scientific. Automated Speciation. prepfast-ic Chromium Speciation for Toy Materials (EN 71-3) ICP ICPMS AA

Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS. Product Overview.

SECTIOn 3. Multi-Element ClP Standards for ICP & ICP-MS

Low-Pressure Chromium Speciation in P2O5 using the Spectro ARCOS MV ICP and the ESI SC-DX chromfast System

MULTI-COMPONENT ANALYSIS OF HEAVY METALS

Matrix Interferences in ICP-MS: Causes, Effects, and Strategies to Reduce or Eliminate Them

Evaluating the performance of the OneNeb Series 2 Nebulizer with PerkinElmer Optima 7/8x00 Series ICP-OES systems

Characterisation of a Cu selective resin for use in the production of Cu isotopes

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

Analysis of Milk for Major and Trace Elements by ICP-MS

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Application Note novaa 800 D. Determination of Macro and Trace Minerals as well as Toxic Trace Metals in Powdered Milk. Challenge.

STANDARD SAMPLE INTRODUCTION

CERTIFICATE OF ANALYSIS

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Determination of Copper in Green Olives using ICP-OES

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Author. Introduction. Abstract

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Application note. Determination of metals in soil by microwave plasma - atomic emission spectrometry (MP-AES) using DTPA extraction.

Analysis of trace elements in nutraceuticals in compliance with USP chapter <2232> Elemental Contaminants in Dietary Supplements

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Order online ne at w elme

CERTIFICATE OF ANALYSIS. tel: fax:

US EPA SW-846 Method 6010D using the Thermo Scientific icap 7400 ICP-OES Duo

RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit

RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit

Routine Analysis of Fortified Foods using the Agilent 7800 ICP-MS

Taking the Complexity out of SPE Method Development

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

RayBio Human Phosphotyrosine BTK ELISA Kit

RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Multi Analyte Custom Grade Solution

Determination of metals in industrial wastewaters by microwave plasmaatomic emission spectrometry

Measuring Lipid Composition LC-MS/MS

COMPARATIVE ANALYSIS FOR MACRO AND TRACE ELEMENTS CONTENT IN GOJI BERRIES BETWEEN VARIETIES FROM CHINA AND R. MACEDONIA

RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes

Determination of Amantadine Residues in Chicken by LCMS-8040

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Mike Hinds, Royal Canadian Mint

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Determination of Ractopamine and Clenbuterol in Beef Samples

USP <232> and <233> Understanding Your Path to Compliance with the New Elemental Impurity Chapters. Steve Wall Agilent Technologies

Food safety is an area of growing concern as a result of pollution,

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

Authors. Abstract. Introduction. Environmental

RayBio Human Granzyme B ELISA Kit

TSH Receptor Autoantibody ELISA

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Ordering Information You may contact us via phone, fax, , or through our website.

Author. Introduction. Small Molecule Pharmaceuticals & Generics

Surviving Matrix Effects Experiments. Grace van der Gugten St. Paul s Hospital, Vancouver, BC, Canada

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Ordering Information You may contact us via phone, fax, , or through our website.

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS

Elemental analysis in clinical practice

Determination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis

Vitamin D3 and related compounds by ESI and APCI

Tailor made sample preparation for unusual bioanalytical research. Erik Baltussen, PhD

High performance graphite furnace tube for determination of lead in blood

Savillex Technical Note

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

Savillex Technical Note

MD1-32 is presented as 96 x 1 ml conditions in a deep-well block.

Electronic Supporting Information

BabyBio IMAC columns DATA SHEET DS

XCF TM COMPLETE Exosome and cfdna Isolation Kit (for Serum & Plasma)

Trace Metal Characterization of Soils Using the Optima 7300 DV ICP-OES

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Ordering Information You may contact us via phone, fax, , or through our website.

Performance of an ultra low elution volume 96-well plate

AppNote 4/2015. Automated Desorption, SPE Extraction, and LC/MS/MS Analysis of Dried Blood Spots KEYWORDS ABSTRACT

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

GSJ Geochemical Reference Samples. Igneous Rock. Sedimentary Rock. For Instrumental analysis. Reference value for environmental analysis -1

EASIMIP TM PATULIN Product Code: P250 / P250B

CERTIFICATE OF ANALYSIS

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

WAGENINGEN EVALUATING PROGRAMS FOR ANALYTICAL LABORATORIES. Certificate of Analysis. International Plant-Analytical Exchange REFERENCE MATERIAL

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis

Transcription:

Elemental Scientific seafast S2 seafast S2 TM Authors: Nathan Saetveit (nathan@icpms.com) Brief The seafast S2 is an automated sample introduction system for multi-mode determination of ultra-trace metals in undiluted seawater. It lowers procedural blanks and improves detection limits for a variety of elements through syringe-based sample preconcentration and matrix elimination. Features: Fully automated, inline preconcentration and matrix removal Direct mode with up to 50x dilution Offline preconcentration mode (optional) Syringe-driven reagents for consistent chemistry and maximum throughput and cleanliness Higher preconcentration factors Flexible sample preconcentration volume Automatic cleaning of buffer cleanup column Completely enclosed liquid flow path for ultra-low blanks Elution Profiles Automated ICPMS optimization Elemental Scientific Figure 1. Simultaneous elution of 6 elements in Preconcentration mode at 1 ppb. 1

SC DX DIWater Buffer Diluent Carrier Figure 2. seafast S2 system with integrated mobile stand. Abstract The seafast S2 is a high performance, automated sample introduction system for the determination of trace elements in seawater and other high matrix samples by ICPMS. Undiluted samples can be measured directly with a user-specified dilution while simultaneously loading an aliquot of sample onto a column for automated, online preconcentration and matrix removal. Both Direct and Preconcentration modes reduce procedural blanks associated with offline sample preparation, and Preconcentration mode dramatically improves detection limits by eliminating matrix effects and increasing sensitivity. The seafast S2 offers complete flexibility and can run in Direct, Preconcentration, or both modes by simply selecting the desired mode(s) in the ESI software. seafast Preconcentration Column 2

seafast S2 Preconcentration or Direct Mode Direct mode Figure 3. Periodic table showing the possible modes for each element. Modes Preconcentration mode: A chelation column binds transition metals and rare earth elements but allows matrix,, Ca 2+ and Mg 2+ ions to be rinsed out. After the preconcentration step, analytes are eluted and detected by ICPMS. Direct mode: Sample is automatically diluted inline by high-precision syringe pumps. Dilution reduces matrix effects and allows the determination of elements whose chemistry is not compatible with the preconcentration column. 3

Preconcentration Mode seafast Preconcentration - Seawater Loading (ph ~ 6) 2) Column rinse (ph ~ 6) 3) Elution (ph < Mg 2+ M+ Ca 2+ Mg 2+ Mg 2+ Ca 2+ M+ M+ Mg 2+ Ca 2+ Cl H - 2 O Ca 2+ Figure 4. At a ph ~ 6, many metals are chelated on the preconcentration column, while matrix elements are flushed from the column. Metals are eluted directly to the ICPMS with nitric acid. Detection Limits in DRC and KED, Preconcentration Mode 10 LOG IDL (ppt) 1 0.1 0.01 V Mn Fe Co Ni Cu Zn Cd Pb DRC IDL KED IDL Figure 5. Detection limits are near or better than 1 ppt on a quadrupole ICPMS (n=10, 3σ). 4

Ultratrace Calibration R 2 = 0.999996 R 2 = 0.999968 Figure 6. Preconcentration mode calibration of Fe and Zn in 3.5% NaCl. Calibration spikes are 1, 10, 50 and 250 ppt. 5

Washout Factors: Co, Cu, Zn, Cd, and Pb 10000 1000 LOG Concentra-on (ppt) 100 10 1 >4,000x >25,000x 1ppt 0.1 >100,000x >270,000x 0.01 5000 ppt Blank1 Blank2 1% Nitric Acid Standards 1% Nitric acid + 3.5% Ultrapure NaCl Standards Direct Mode Figure 7. Washout in Preconcentration mode is excellent with both 1% nitric acid calibration standards and matrix-matched standards. Matrix matching the standards with seablank is not required for Preconcentration mode, but it enhances washout. Inline Dilution R 2 = 0.999996 Figure 8. Direct mode calibration of Tl in 3.5% NaCl. Calibration spikes are 1, 10, 50, 250 and 500 ppt. 6

Results seafast S2 NASS-6 Determination, DRC, Preconcentration and Direct P = Preconcentration Mode D = Direct Mode seafast S2 CASS-5 Determination, DRC, Preconcentration and Direct 10000 1000 LOG Concentra-on (ppt) 100 10 1 0.1 0.01 V (P) Cr (D) Mn (P) Fe (P) Co (P) Ni (P) Cu (P) Zn (P) Mo (D) Cd (P) Pb (P) U (P) IDL CASS- 5 (n=4) Cer-fied Value Figure 9. Results for NASS-6 and CASS-5 Seawater Reference Materials are shown. Elements determined with the seafast S2 are accurate and precise for elements with certified concentrations from < 10 ppt to > 10 ppb. 7

Benefits: Low blanks Low carryover Sub-ppt IDL's FAST: < 8 minutes inline Eliminate pump tubing No daily maintenance Easy ICPMS optimization 1500 North 24th Street Omaha, NE 68110 USA Phone: 1.402.991.7800 Fax: 1.402.991.7799 Email: prepfast@icpms.com Web: www.prepfast.com www.icpms.com Elemental Scientific 8