» For multi-unit restorations -

Similar documents
The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended.

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

Type 1. Type 2. Straumann Tissue Level. The N-Series abutments are compatible with» N-SERIES «

» MEDENTIKA PreFace Abutments

Bridging the Gap Between Original and Multi-Platform Systems.

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

for individual abutment design large glue surface, so durable solid connection to the base conventional usable and also for CAD/CAM process

» Passion IMPLANT PICK-UP. for Precision « MPS Multi Platform Systems. Closed tray

Straumann Screw-retained Prosthetics

Catalog. etkon ident Compatibles perfected. From a partner you can trust _etkon_iDent_Catalogue_nordic indd :56:11

S-SERIES. compatible to: DENTSPLY Implants / Astra Tech Implant System OsseoSpeed TX. PLATFORM 3,5 / 4,0 mm 4,5 / 5,0 mm TITANIUM BASE

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

cara I-Bridge Torque for Prosthetic Screws and overview of Screwdrivers

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

LOCATOR R-Tx REMOVABLE ATTACHMENT SYSTEM

Straumann Dental System Indication-based prosthetic workflow. Technical Information

N-SERIES. compatible to: Straumann / SynOcta 32 NT-TRADING CATALOGUE PLATFORM 3,5 mm NN 4,8 mm RN 6,5 mm WN TITANIUM BASE SCAN BODY 3D-GUIDE

TruAbutment Digital Solutions

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health.

ATTACHMENT SYSTEM. LOCATOR R-Tx REMOVABLE U.S. RETAIL PRODUCT CATALOG AND PRICE LIST*

24 About us Sincerely. Content SCREW SELECTION GUIDE

» Prosthetic Options by MEDENTiKA «

BONE LEVEL ABUTMENTS. on4. multi-unit

More than Abutments. catalogue

» Passion IN A NUTSHELL. for Precision « MPS Multi Platform Systems

Watson Dental Lab Fixed Hybrid Protocol

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

E-SERIES. compatible to: Nobel Biocare / Replace Select. PLATFORM 3,5 mm NP 4,3 mm RP 5,0 mm WP 6,0 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health.

MICROCONE. IPS Implant Systems

PROSTHETIC EFFICIENCY. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance.

IMPLANT PROSTHETICS

Ø Smaller and Stronger.

for individual milled Zirconium Abutment incl. screws Titanium Grade 5 ELI CAM CAM CAM CAM

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

NEW IMPLANT PLATFORMS AVAILABLE NewJANUARY 2018

Quick start Prosthetics

T-SERIES. compatible to: DENTSPLY Implants / Xive. PLATFORM 3,4 mm 3,8 mm 4,5 mm 5,5 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG IMPLANT PICK-UP

R-SERIES. compatible to: Zimmer Dental / Tapered Screw-Vent 36 NT-TRADING CATALOGUE PLATFORM 3,5 mm 4,5 mm 5,7 mm TITANIUM BASE

Legacy Prosthetic Catalog

Straumann Variobase for Bridge/Bar

cara I-Bridge Overview of platforms and systems es life so easy

STRAUMANN CARES DIGITAL SOLUTIONS. CARES Implant Prosthetics Ultimate restorative flexibility.

CAD-CAM SOLUTIONS CAD-CAM SOLUTIONS

BIO-SERIES. compatible to: BioHorizons / internal. PLATFORM 3,0 mm 3,5 mm 4,5 mm 5,7 mm TITANIUM BASE SCAN BODY 3D-GUIDE NT-MILL LAB ANALOG

cara I-Bridge Overview of platforms and systems es life so easy

Multi-Unit Abutment Guide

N T- P R E F O R M CaTalOguE

TITANIUM BASES CAD/CAM FOR CROWN AND BRIDGE RESTORATIONS CAD/CAM PROSTHETICS ON CAMLOG AND CONELOG IMPLANTS

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

Ø Smaller and Stronger.

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte


BEG-SERIES. compatible to: BEGO Implant Systems / Semados S, RS-RX, RI-Line 12 NT-TRADING CATALOGUE

PRE-MILLED BLANK COMPLETE SOLUTION

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Product Information. Straumann CARES Scan & Shape Turn into digital.

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

3D-Guide. Scanbody for high-precision implant position transfer INTERNATIONAL PATENT BENEFITS: APPLICATION: TECHNICAL DETAILS:

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

CAD/CAM Prosthetic Solutions

cement-retained single crowns using cementable abutments

Stock Prosthetic Guide 2014

*Digital Implant Model ANALOG Available for 24 implant systems in the nt-iq library FEATURES: INTERNATIONAL PATENT PENDING

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

Multi-unit abutment open tray technique using the direct pick-up coping

This recommendation outlines the requisite steps for the optimal use of the BEGO CADPositioner.

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

Restorative Manual. April

Digital Treatment Planning and Surgical Guide Fabrication

Product Information. Straumann CARES Scan & Shape Turning into digital solutions.

SwissPlant Prosthetic Catalog. SwissPlant

Restoring Straumann implants. with Locator abutments.

More than a Ti-base. Your trusted link between implant and restoration. Straumann Variobase C. Variobase for CEREC becomes Variobase C

Multi-unit abutment closed tray technique using the indirect transfer coping

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection

For technical assistance: Tel Working time: 8.30 am pm

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

User Manual Complete Prosthetic Kit (CPK)

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Multi-unit abutment bar overdenture

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

PRE-MILLED ABUTMENTS COMPLETE SOLUTIONS

IMPLANT / ABUTMENT CONNECTIONS

Multi-unit abutment hybrid or fixed-detachable screw-retained restoration

Procedure and Laboratory Manual For Cagenix AccuFrame System

surgical and prosthetic options & impression technique overview

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

HEXAGON Implant System

Dual-Use Scan Bodies ID and Implant Configuration For itero. Precision manufactured by

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

InterActive TM System. Catalog

Transcription:

» For multi-unit restorations - conventional or digital «Multi-Unit Abutments

2 The Multi-unit product range is being contiunally expanded to include other abutment series. Available for a large number of implant systems: Page 3 Multi-unit Instruction Manual 14 CF-Series compatible with Nobel Biocare NobelActive * NobelReplace Conical* 17 CH-Series compatible with BIOMET 3i Certain * 20 CL-Series compatible with Straumann Bone Level** 23 CN-Series compatible with Straumann Tissue Level** 25 CR-Series compatible with Zimmer Dental Screw-Vent * MIS SEVEN Internal Hex** BioHorizons Tapered Internal** Tapered Internal Plus** Tapered Tissue Level** 29 CV-Series compatible with Dentsply Implants ASTRA TECH OsseoSpeed EV** * is a registered trademark of an independent third party ** is a product name of an independent third party

» «3 The supports a variety of prosthetic restorations. It is ideal for creating patient oriented individual hybrid restorations or being the base for an individualized restoration according to the Allon-4 * principle. Implant with conventional shoulder and straight abutment Implant with conventional shoulder and 30 angled abutment * is a registered trademark of an independent third party

4» The All-on-4 principle* «The All-on-4 * principle for atrophic ridges allows for a comprehensive treatment plan for edentulous patients by providing a full-arch immediate restoration, using just two straight and two 30 angulated implants. The temporary restoration is immediately placed over the implants using the s. The straight and 30 angled s allow for a common insertion direction for the prosthetic restoration. Multi-unit titanium base incl. bridge screw Multi-unit abutment straight Multi-unit abutment angled 30 * is a registered trademark of an independent third party All s are supplied with the insertion aid.

» There are various possibilities for prosthetic restorations «5 Paste the titanium base into the denture to create a temporary restoration. The framework production of superstructures by means of castable CoCr caps or castable gold caps. CADCAM milled bars or bridges. All-on-4 * treatment concept. Full denture A provisional full denture is sufficiently worked out in the area of the titanium bases and then tension free inserted in the denture on the model and / or in the mouth. Final bridge restoration on two implants in the posterior region A metal framework is sufficiently worked out in the area of the titanium bases and then orally glued without tension. Next exists the possibility of making the framework by means of directly cast on the gold caps or CoCr caps. After final construction the bridge will be screwed occlusally. This procedure is also suitable for the preparation of a final full arch resoration on at least four implants in the lower jaw or six implants in the upper jaw. Bar with removable full denture A casted or CAD CAM milled bar is screwed on Multi-Unit abutments. Afterwards, depending on the indication and patient request, the final removable denture can be manufactured. * is a registered trademark of an independent third party

6» s «Treatment options There are various prosthetic components for different treatment options. Gingiva height The s are available in 3 different gingival heights. Implant connection Available with implant connections to most popular implant manufacturers.» Determination of the gingival height «The gingiva height stated in the catalogue is marked here as GH1. With the two angled abutments GH2 is calculated as shown: GH 2 = GH 1-1.4 mm GH 2 = GH 1-2.4 mm 0 17 30 GH 1 GH 2 GH 1 GH 2 GH 1

7 Treatment options There are various prosthetic components for the different treatment otions. Gingiva height The s are available in 3 different gingival heights. Implant connection Compatible to most popular implant connections. Two angulations The s are available with 17 and 30 angulation. Angulation Variant Gingiva height (GH)* low straight medium high 17 : over flat Type 2: over corner low medium high 30 : over flat Type 2: over corner low medium high *Exact lengths depend on the implant system

8» Multi-unit prosthetic components «Castable gold cap to cast gold alloys Castable CoCr cap to cast non-precious metals base to glue into the bridge/denture (passive fit) cap to shorten and glue into the bridge or denture as well as to create temporary restorations Modelling aid for modelling on the titanium cap or titanium base only usable in combination with the titanium base or titanium cap Bridge screw included with every cap and the titanium base

» Multi-unit prosthetic components for digital restorations «9 Multi-unit Scanbody straight for digital impression of the straight s Multi-unit Scanbody angled for digital impression of the angled Multi-unit abutments 17 and 30 base to glue into the bridge/denture (passive fit) cap to shorten and glue into the bridge or denture and to create temporary restorations Multi-unit lab analog for CADCAM for use with digital model production (print model) Bridge screw included with every cap and the titanium base

10» Lab Analogs for s «Straight Multi-unit analog for use with conventional model production. Angled Multi-unit analog for use with conventional model production. Angled 17 & 30. Straight Multi-unit analog for CADCAM for use with digital model production (print model). Angled Multi-unit analog for CADCAM for use with digital model production (print model). Angled 17 & 30.

» Multi-unit accessories «11 Impression coping for impression of the s. Cover cap to protect the abutments during the healing phase. Placement instrument used to torque the straight Multi-unit abutments.» Multi-unit divergency compensation «The s have a uniform platform to the prosthetic components with a conicity of 21 (one-sided). When using the 30 angled Multi-unit abutments divergencies of up to 102 between implants can be covered. This results due to the 30 angulation of the multi-unit abutments and the conicity of the 21 platform. 51 51 21 30 102

12» How to use «straight After the implant placement, the straight is connected to the implant with its special insertion aid and tightened with the insertion tool up to the recommended torque. 1 2 3 4 All s are supplied with the insertion aid.

» How to use «13 angled After the implant placement, the angulated is connected to the implant with its special insertion aid and tightened with the screw up to the recommended torque. 1 2 3 All s are supplied with the insertion aid.

14» CF-SERIES «Nobel Biocare NobelActive / NobelReplace Conical straight Recommended torque: 35 Ncm Implant connection NP 3.5 NP 3.5 NP 3.5 Gingiva height 1.5 mm 3.5 mm 5.5 mm Article No. CF 8000 CF 8001 CF 8002 straight Recommended torque: 35 Ncm Implant connection RP 4.3/5.0 RP 4.3/5.0 RP 4.3/5.0 Gingiva height 1.5 mm 3.5 mm 5.5 mm Article No. CF 8010 CF 8011 CF 8012 angled 17 Recommended torque: 35 Ncm Implant connection NP 3.5 NP 3.5 NP 3.5 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CF 8100 CF 8101 CF 8102 Abutment screw CF 600 CF 600 CF 600 angled 30 Recommended torque: 35 Ncm Implant connection NP 3.5 NP 3.5 NP 3.5 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CF 8300 CF 8301 CF 8302 Abutment screw CF 600 CF 600 CF 600

» CF-SERIES «Nobel Biocare NobelActive / NobelReplace Conical 15 angled 17 Recommended torque: 35 Ncm Implant connection RP 4.3/5.0 RP 4.3/5.0 RP 4.3/5.0 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CF 8110 CF 8111 CF 8112 Abutment screw CF 601 CF 601 CF 601 angled 30 Recommended torque: 35 Ncm Implant connection RP 4.3/5.0 RP 4.3/5.0 RP 4.3/5.0 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CF 8310 CF 8311 CF 8312 Abutment screw CF 601 CF 601 CF 601 Multi-unit prosthetic components CF 8501 Multi-unit bridge screw UG CF 8508 Multi-unit titanium base incl. bridge screw CF 8505 Multi-unit titanium cap incl. bridge screw CF 8506 Multi-unit gold cap, castable incl. bridge screw CF 8507 Multi-unit CoCr cap incl. bridge screw Recommended torque: 15 Ncm Material "(AU 60%; Pd 20%; Pt 19%; Ir 1%)" CrCo alloy / CTE 14.1 Article No. CF 8501 CF 8508 CF 8505 CF 8506 CF 8507 Multi-unit modelling sleeve Tecanat (PC) Article No. 8510 Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and Multi-unit titanium cap. Multi-unit scanbody specially coated incl. bridge screw Version straight angled Article No. CF 8500 CF 8513 Please note: The Scanbody is sterilisable for intra-oral scanning.

16» CF-SERIES «Nobel Biocare NobelActive / NobelReplace Conical Multi-unit Laboratory implant Version straight angled angled 7 30 Article No. 8504 8514-17 8514-30 Multi-unit Laboratory implant CADCAM Version straight angled angled 7 30 Article No. 8509 8515-17 8515-30 Multi-unit accessories CF 8502 Multi-unit cover cap CF 8503 Multi-unit open tray impression coping M 11-11 Placement instrument 8515 T Placement instrument laboratory implant CADCAM Article No. CF 8502 CF 8503 M 11-11 8515 T

» CH-SERIES «straight Recommended torque: 20 Ncm Biomet 3i Certain 17 Implant connection D 3.4 D 3.4 D 3.4 Gingiva height 1.0 mm 3.0 mm 5.0 mm Article No. CH 8000 CH 8001 CH 8002 straight Recommended torque: 20 Ncm Implant connection D 4.1 D 4.1 D 4.1 Gingiva height 1.0 mm 3.0 mm 5.0 mm Article No. CH 8010 CH 8011 CH 8012 angled 17 Recommended torque: 20 Ncm Implant connection D 3.4 D 3.4 D 3.4 Gingiva height 2.0 mm 3.0 mm 5.0 mm Article No. CH 8100 CH 8101 CH 8102 Abutment screw CH 62 CH 62 CH 62 angled 30 Recommended torque: 20 Ncm Implant connection D 3.4 D 3.4 D 3.4 Gingiva height 3.0 mm 4.0 mm 5.0 mm Article No. CH 8300 CH 8301 CH 8302 Abutment screw CH 62 CH 62 CH 62

18» CH-SERIES «Biomet 3i Certain angled 17 Recommended torque: 20 Ncm Implant connection D 4.1 D 4.1 D 4.1 Gingiva height 2.0 mm 3.0 mm 5.0 mm Article No. CH 8110 CH 8111 CH 8112 Abutment screw CH 62 CH 62 CH 62 angled 30 Recommended torque: 20 Ncm Implant connection D 4.1 D 4.1 D 4.1 Gingiva height 3.0 mm 4.0 mm 5.0 mm Article No. CH 8310 CH 8311 CH 8312 Abutment screw CH 62 CH 62 CH 62 Multi-unit prosthetic components CH 8501 Multi-unit bridge screw Hex 1.2 CH 8508 Multi-unit titanium base incl. bridge screw CH 8505 Multi-unit titanium cap incl. bridge screw CH 8506 Multi-unit gold cap, castable incl. bridge screw CH 8507 Multi-unit CoCr cap incl. bridge screw Recommended torque: 15 Ncm Material "(AU 60%; Pd 20%; Pt 19%; Ir 1%)" CrCo alloy / CTE 14.1 Article No. CH 8501 CH 8508 CH 8505 CH 8506 CH 8507 Multi-unit modelling sleeve Tecanat (PC) Article No. 8510 Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and Multi-unit titanium cap. Multi-unit scanbody specially coated incl. bridge screw Version straight angled Article No. CH 8500 CH 8513 Please note: The Scanbody is sterilisable for intra-oral scanning.

» CH-SERIES «Biomet 3i Certain 19 Multi-unit Laboratory implant Version straight angled angled 7 30 Article No. 8504 8514-17 8514-30 Multi-unit Laboratory implant CADCAM Version straight angled angled 7 30 Article No. 8509 8515-17 8515-30 Multi-unit accessories CH 8502 Multi-unit cover cap CH 8503 Multi-unit open tray impression coping M 11-11 Placement instrument 8515 T Placement instrument laboratory implant CADCAM Article No. CH 8502 CH 8503 M 11-11 8515 T

20» CL-SERIES «Straumann Bone Level straight Recommended torque: 35 Ncm Implant connection NC 3.3 NC 3.3 NC 3.3 Gingiva height 1.5 mm 3.5 mm 5.5 mm Article No. CL 8000 CL 8001 CL 8002 straight Recommended torque: 35 Ncm Implant connection RC 4.1/4.8 RC 4.1/4.8 RC 4.1/4.8 Gingiva height 1.5 mm 3.5 mm 5.5 mm Article No. CL 8010 CL 8011 CL 8012 angled 17 Type 2 = angled over corner Recommended torque: 35 Ncm Type 2 Implant connection NC 3.3 NC 3.3 NC 3.3 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CL 8100 CL 8101 CL 8102 Article No. Type 2 CL 8200 CL 8201 CL 8202 Abutment screw CL 65 CL 65 CL 65 angled 30 Type 2 = angled over corner Recommended torque: 35 Ncm Type 2 Implant connection NC 3.3 NC 3.3 NC 3.3 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CL 8300 CL 8301 CL 8302 Article No. Type 2 CL 8400 CL 8401 CL 8402 Abutment screw CL 65 CL 65 CL 65

» CL-SERIES «Straumann Bone Level 21 angled 17 Type 2 = angled over corner Recommended torque: 35 Ncm Type 2 Implant connection RC 4.1/4.8 RC 4.1/4.8 RC 4.1/4.8 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CL 8110 CL 8111 CL 8112 Article No. Type 2 CL 8210 CL 8211 CL 8212 Abutment screw CL 65 CL 65 CL 65 angled 30 Type 2 = angled over corner Recommended torque: 35 Ncm Type 2 Implant connection RC 4.1/4.8 RC 4.1/4.8 RC 4.1/4.8 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CL 8310 CL 8311 CL 8312 Article No. Type 2 CL 8410 CL 8411 CL 8412 Abutment screw CL 65 CL 65 CL 65 Multi-unit prosthetic components CL 8501 Multi-unit bridge screw Torx T6 CL 8508 Multi-unit titanium base incl. bridge screw CL 8505 Multi-unit titanium cap incl. bridge screw CL 8506 Multi-unit gold cap, castable incl. bridge screw CL 8507 Multi-unit CoCr cap incl. bridge screw Recommended torque: 15 Ncm Material "(AU 60%; Pd 20%; Pt 19%; Ir 1%)" CrCo alloy / CTE 14.1 Article No. CL 8501 CL 8508 CL 8505 CL 8506 CL 8507 Multi-unit modelling sleeve Tecanat (PC) Article No. 8510 Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and Multi-unit titanium cap.

22» CL-SERIES «Straumann Bone Level Multi-unit scanbody specially coated incl. bridge screw Version straight angled Article No. L 8500 L 8513 Please note: The Scanbody is sterilisable for intra-oral scanning. Multi-unit Laboratory implant Version straight angled angled 7 30 Article No. 8504 8514-17 8514-30 Multi-unit Laboratory implant CADCAM Version straight angled angled 7 30 Article No. 8509 8515-17 8515-30 Multi-unit accessories CL 8502 Multi-unit cover cap CL 8503 Multi-unit open tray impression coping M 11-11 Placement instrument 8515 T Placement instrument laboratory implant CADCAM Article No. CL 8502 CL 8503 M 11-11 8515 T

» CN-SERIES «Straumann Tissue Level 23 straight Recommended torque: 35 Ncm Implant connection RN 4.8 Gingiva height 0.9 mm Article No. CN 8010 straight Recommended torque: 35 Ncm Implant connection WN 6.5 Gingiva height 1.2 mm Article No. CN 8020 Multi-unit prosthetic components CN 8501 Multi-unit bridge screw Torx T6 CN 8508 Multi-unit titanium base incl. bridge screw CN 8505 Multi-unit titanium cap incl. bridge screw CN 8506 Multi-unit gold cap, castable incl. bridge screw CN 8507 Multi-unit CoCr cap incl. bridge screw Recommended torque: 15 Ncm Material "(AU 60%; Pd 20%; Pt 19%; Ir 1%)" CrCo alloy / CTE 14.1 Article No. CN 8501 CN 8508 CN 8505 CN 8506 CN 8507 Multi-unit modelling sleeve Tecanat (PC) Article No. 8510 Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and Multi-unit titanium cap. Multi-unit scanbody specially coated incl. bridge screw Version straight Article No. CN 8500 Please note: The Scanbody is sterilisable for intra-oral scanning.

24» CN-SERIES «Straumann Tissue Level Multi-unit Laboratory implant Version straight angled angled 7 30 Article No. 8504 8514-17 8514-30 Multi-unit Laboratory implant CADCAM Version straight angled angled 7 30 Article No. 8509 8515-17 8515-30 Multi-unit accessories M 11-11 Placement instrument CN 8502 Multi-unit cover cap CN 8503 Multi-unit open tray impression coping 8515 T Placement instrument laboratory implant CADCAM Article No. M 11-11 CN 8502 CN 8503 8515 T

» CR-SERIES «Zimmer Dental - Tapered Screw-Vent MIS - SEVEN Internal Hex BioHorizons - Tapered Internal/Internal Plus/Tissue Level 25 Comparison chart Zimmer Dental MIS BioHorizons Zimmer Dental Platform 3,5 mm Platform 4,5 mm Platform 5,7 mm Implant Ø 3.70 4.10 4.70 6.00 Laboratory implant Ø 3.50 3.50 4.50 5.70 Article Number IA3 IA3 IA4 IA5 Implant connection Medentika R-Series Laboratory implant 3.5 3.5 4.5 5.7 Article Number CR 50 CR 50 CR 51 CR 52 MIS Narrow- Platform Standard- Platform Wide- Platform Implant Ø 3.30 3.30 3.75 4.20 5.00 6.00 Laboratory implant Ø 3.30 4.20 4.20 4.20 4.50 4.50 Article Number MN-RSM10 MD-RSM10 MD-RSM10 MD-RSM10 MW-RSM10 MW-RSM10 Implant connection Medentika R-Series Laboratory implant XX 3.50 3.50 3.50 4.50 4.50 Article Number XX CR 50 CR 50 CR 50 CR 51 CR 51 BioHorizons Platform 3,0 mm Platform 3,5 mm Platform 4,5 mm Platform 5,7 mm Implant Ø 3.00 3.80 4.60 5.80 Laboratory implant Ø 3.00 3.50 4.50 5.70 Article Number TP3IA SYIA SGIA SBIA Implant connection Medentika R-Series Laboratory implant 3.0 3.50 4.50 5.70 Article Number CR 53 CR 50 CR 51 CR 52

26» CR-SERIES «Zimmer Dental - Tapered Screw-Vent MIS - SEVEN Internal Hex BioHorizons - Tapered Internal/Internal Plus/Tissue Level straight Recommended torque: 30 Ncm Implant connection D 3.5 D 3.5 D 3.5 Gingiva height 1.0 mm 3.0 mm 5.0 mm Article No. CR 8000 CR 8001 CR 8002 straight Recommended torque: 30 Ncm Implant connection D 4.5 D 4.5 D 4.5 Gingiva height 1.0 mm 3.0 mm 5.0 mm Article No. CR 8010 CR 8011 CR 8012 angled 17 Recommended torque: 30 Ncm Implant connection D 3.5 D 3.5 D 3.5 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CR 8100 CR 8101 CR 8102 Abutment screw CR 64 CR 64 CR 64 angled 30 Recommended torque: 30 Ncm Implant connection D 3.5 D 3.5 D 3.5 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CR 8300 CR 8301 CR 8302 Abutment screw CR 64 CR 64 CR 64

» CR-SERIES «Zimmer Dental - Tapered Screw-Vent MIS - SEVEN Internal Hex BioHorizons - Tapered Internal/Internal Plus/Tissue Level angled 17 Recommended torque: 30 Ncm 27 Implant connection D 4.5 D 4.5 D 4.5 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CR 8110 CR 8111 CR 8112 Abutment screw CR 64 CR 64 CR 64 angled 30 Recommended torque: 30 Ncm Implant connection D 4.5 D 4.5 D 4.5 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CR 8310 CR 8311 CR 8312 Abutment screw CR 64 CR 64 CR 64 Multi-unit prosthetic components CR 8501 Multi-unit bridge screw Hex 1.26 CR 8508 Multi-unit titanium base incl. bridge screw CR 8505 Multi-unit titanium cap incl. bridge screw CR 8506 Multi-unit gold cap, castable incl. bridge screw CR 8507 Multi-unit CoCr cap incl. bridge screw Recommended torque: 15 Ncm Material "(AU 60%; Pd 20%; Pt 19%; Ir 1%)" CrCo alloy / CTE 14.1 Article No. CR 8501 CR 8508 CR 8505 CR 8506 CR 8507 Multi-unit modelling sleeve Tecanat (PC) Article No. 8510 Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and Multi-unit titanium cap. Multi-unit scanbody specially coated incl. bridge screw Version straight angled Article No. CR 8500 CR 8513 Please note: The Scanbody is sterilisable for intra-oral scanning.

28» CR-SERIES «Zimmer Dental - Tapered Screw-Vent MIS - SEVEN Internal Hex BioHorizons - Tapered Internal/Internal Plus/Tissue Level Multi-unit Laboratory implant Version straight angled angled 7 30 Article No. 8504 8514-17 8514-30 Multi-unit Laboratory implant CADCAM Version straight angled angled 7 30 Article No. 8509 8515-17 8515-30 Multi-unit accessories M 11-11 Placement instrument CR 8502 Multi-unit cover cap CR 8503 Multi-unit open tray impression coping 8515 T Placement instrument laboratory implant CADCAM Article No. M 11-11 CR 8502 CR 8503 8515 T

» CV-SERIES «Dentsply Implants ASTRA TECH OsseoSpeed EV 29 straight Recommended torque: 25 Ncm Implant connection D 3.6 D 3.6 D 3.6 Gingiva height 1.5 mm 3.5 mm 5.5 mm Article No. CV 8010 CV 8011 CV 8012 straight Recommended torque: 25 Ncm Implant connection D 4.2 D 4.2 D 4.2 Gingiva height 1.5 mm 3.5 mm 5.5 mm Article No. CV 8020 CV 8021 CV 8022 straight Recommended torque: 25 Ncm Implant connection D 4.8 D 4.8 D 4.8 Gingiva height 1.5 mm 3.5 mm 5.5 mm Article No. CV 8030 CV 8031 CV 8032 angled 17 Recommended torque: 25 Ncm Implant connection D 3.6 D 3.6 D 3.6 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CV 8110 CV 8111 CV 8112 Abutment screw CV 64 CV 64 CV 64 angled 30 Recommended torque: 25 Ncm Implant connection D 3.6 D 3.6 D 3.6 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CV 8310 CV 8311 CV 8312 Abutment screw CV 64 CV 64 CV 64

30» CV-SERIES «Dentsply Implants ASTRA TECH OsseoSpeed EV angled 17 Recommended torque: 25 Ncm Implant connection D 4.2 D 4.2 D 4.2 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CV 8120 CV 8121 CV 8122 Abutment screw CV 65 CV 65 CV 65 angled 30 Recommended torque: 25 Ncm Implant connection D 4.2 D 4.2 D 4.2 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CV 8320 CV 8321 CV 8322 Abutment screw CV 65 CV 65 CV 65 angled 17 Recommended torque: 25 Ncm Implant connection D 4.8 D 4.8 D 4.8 Gingiva height 2.5 mm 3.5 mm 5.5 mm Article No. CV 8130 CV 8131 CV 8132 Abutment screw CV 66 CV 66 CV 66 angled 30 Recommended torque: 25 Ncm Implant connection D 4.8 D 4.8 D 4.8 Gingiva height 3.0 mm 4.0 mm 5.5 mm Article No. CV 8330 CV 8331 CV 8332 Abutment screw CV 66 CV 66 CV 66

» CV-SERIES «Dentsply Implants ASTRA TECH OsseoSpeed EV 31 Multi-unit prosthetic components CV 8501 Multi-unit bridge screw Hex 1.26 CV 8508 Multi-unit titanium base incl. bridge screw CV 8505 Multi-unit titanium cap incl. bridge screw CV 8506 Multi-unit gold cap, castable incl. bridge screw CV 8507 Multi-unit CoCr cap incl. bridge screw Recommended torque: 15 Ncm Material "(AU 60%; Pd 20%; Pt 19%; Ir 1%)" CrCo alloy / CTE 14.1 Article No. CV 8501 CV 8508 CV 8505 CV 8506 CV 8507 Multi-unit modelling sleeve Tecanat (PC) Article No. 8510 Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and Multi-unit titanium cap. Multi-unit scanbody specially coated incl. bridge screw Version straight angled Article No. CV 8500 CV 8513 Please note: The Scanbody is sterilisable for intra-oral scanning. Multi-unit Laboratory implant Version straight angled angled 7 30 Article No. 8504 8514-17 8514-30 Multi-unit Laboratory implant CADCAM Version straight angled angled 7 30 Article No. 8509 8515-17 8515-30 Multi-unit accessories CV 8502 Multi-unit cover cap CV 8503 Multi-unit open tray impression coping M 11-11 Placement instrument 8515 T Placement instrument laboratory implant CADCAM Article No. CV 8502 CV 8503 M 11-11 8515 T

32 Office hours: Monday - Thursday 9am - 6pm EST Friday 9am - 5:30pm EST Next day delivery on orders placed before 6pm EST Free Shipping on orders over $500.00 (before taxes) Abutment Direct Inc. 102-7351 Victoria Park Avenue, Markham, ON Canada L3R 3A5 Phone: (905) 604-0465 Fax: (905) 604-0900 Toll Free: 1-855-604-0465 info@abutmentdirect.com www.abutmentdirect.com