The Egyptian Journal of Hospital Medicine (January 2018) Vol. 70 (8), Page

Similar documents
INTRODUCTION S. HERDENER, D. HAFIZOVIC, M. PACHE, S. LAUTEBACH, J. FUNK. University Eye Hospital, Freiburg - Germany

Clinical Study Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure

Correspondence should be addressed to Fusako Fujimura;

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer

Kobe University Repository : Kernel

Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty

1/31/2018. Course Objectives. Diagnostic Testing. Optic Nerve Damage ANATOMY AND PHYSIOLOGY OF A GLAUCOMA WORK-UP/TONOMETRY TECHNICIAN: -SDP

Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry

CLINICAL SCIENCES. Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry

Role of central corneal thickness measurement in management of open angle glaucoma and glaucoma suspects in Calabar, Nigeria

True IOP No Doubt Facts and Figures Figures. Ziemer Ophthalmic Systems AG a Ziemer Group Company Allmendstrasse 11 CH-2562 Port, Switzerland

Dina H. Erickson, O.D., a Denise Goodwin, O.D., a Michael Rollins, O.D., b Amber Belaustegui, O.D., c and Chad Anderson a

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

Intro to Glaucoma/2006

CLINICAL SCIENCES. Comparison of Ocular Response Analyzer Parameters in Chinese Subjects With Primary Angle-Closure and Primary Open-Angle Glaucoma

Clinical Study Comprasion of ICare Rebound Tonometer and Goldmann Applanation Tonometer in High Myopia

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.

Correlating central corneal thickness and intraocular pressure in ocular hypertension and glaucoma

Seung Pil Bang, Chong Eun Lee and Yu Cheol Kim *

The Association of Central corneal thickness with Intra-ocular Pressure and Refractive Error in a Nigerian Population

Closed Angle Glaucoma Or Narrow Angle Glaucoma. What s is a closed angle type of glaucoma,

1 Birmingham and Midland Eye Centre, City Hospital, Birmingham, 2 Ophthalmic Research Group, Life and Health Sciences, Aston

Training Checking Vision Tonometry

Effect of brimonidine on intraocular pressure in normal tension glaucoma: A short term clinical trial

The Ocular Response Analyzer (ORA; Reichert Ophthalmic

Laser in situ keratomileusis (LASIK) has

Kathryn L. Wotman, DVM, DACVIM Jeffrey E. Bowersox, DVM, DACVO. Veterinary Specialty Center of Delaware

December 2016, Volume: 8, Issue: 12, Pages: , DOI:

Comparison of icare Tonometer with Pulsair and Tonopen in Domiciliary Work

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS

The changes in corneal biomechanical parameters after phototherapeutic keratectomy in eyes with granular corneal dystrophy

Goals. Glaucoma PARA PEARL TO DO. Vision Loss with Glaucoma

Self-monitoring of disease has long been of proven value. For

NIIOS. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece VASILIS S.

LARGE DISCS WITH LARGE CUPS A DIAGNOSTIC CHALLENGE IN AFRICAN PATIENTS. Darshana Soma

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

RECENT ADVANCES IN ANTERIOR SEGMENT IMAGING OF THE EYE. by Eszter Szalai, M.D. Supervisor: László Módis, M.D., Ph.D.

Megalocornea is a non-progressive, uniformly

Intraocular pressure (IOP) is of fundamental importance in

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow

PedsCases Podcast Scripts

Comparison of a New Non-Contact Tonometer with Goldmann Applanation

MODERN DIAGNOSTICS AND TREATMENT OF GLAUCOMA

Author s Affiliation. Original Article. Comparison of Biometry in Phakic and Dense Modes. Muhammad Suhail Sarwar. Unaiza Mariam

Central corneal thickness determined with optical coherence tomography in various types of glaucoma

Accuracy and Repeatability of a New Portable Ultrasound Pachymeter

Central corneal thickness among glaucoma patients attending Menelik II Hospital, Addis Ababa, Ethiopia

Interest in central corneal thickness (CCT) and glaucoma was. Central Corneal Thickness and Glaucoma in East Asian People.

Glaucoma: Diagnostic Modalities

City, University of London Institutional Repository

THE CHRONIC GLAUCOMAS

Written by Administrator Wednesday, 13 January :27 - Last Updated Thursday, 21 January :34

GLAUCOMA REPEAT READINGS PATHWAY

THE CHRONIC GLAUCOMAS

International Journal of Health Sciences and Research ISSN:

Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial

Glaucoma. Glaucoma. Optic Disc Cupping

Agreement between methods of measurement

Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter

STUDY OF EFFECTIVENESS OF LENS EXTRACTION AND PCIOL IMPLANTATION IN PRIMARY ANGLE CLOSURE GLAUCOMA Sudhakar Rao P 1, K. Revathy 2, T.

The innovative aspects are that ORA G3 is currently the only device capable of measuring corneal hysteresis.

OPTOMETRY RESEARCH PAPER

4/06/2013. Medication Observation POAG. Proportion. Native American 0.1% 0.4%

Central Corneal Thickness in Primary Angle Closure and Open Angle Glaucoma

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors

A Comparative Study on the Inter-Session and Inter- Examiner Reliability of Corneal Power Measurement Using Various Keratometry Instruments

Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo


A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics

Glaucoma is the leading cause of irreversible blindness in

Comparative Efficacy of the New Optical Biometer on Intraocular Lens Power Calculation (AL-Scan versus IOLMaster)

Comparison of intraocular pressure measurement with Schiotz tonometer and Tono-Pen Vet tonometer in healthy dogs

It all begins with CASE HISTORY

The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology

CLINICAL RESEARCH METHODS VISP356. MODULE LEADER: PROF A TOMLINSON B.Sc./B.Sc.(HONS) OPTOMETRY

GLAUCOMA. An Overview

Correlation and agreement between the 24-hour diurnal tension curve, the water-drinking test, and the postural-change test in glaucoma patients*

National Glaucoma Research Report Fall 2018

CAN TIGHT NECKTIE BE A RISK FACTOR IN DEVELOPMENT AND PROGRESSION OF PRIMARY- OPEN ANGLE GLAUCOMA (POAG)?

Central Cornea Thickness in Glaucoma and Non- Glaucoma African Population

THE TAMILNADU DR.M.G.R. MEDICAL UNIVERSITY CHENNAI, TAMILNADU

Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy

Corporate Medical Policy

INTRODUCTION MIKLOS SCHNEIDER 1, GABOR BORGULYA 2, ANDRAS SERES 1, ZOLTAN Z. NAGY 1, JANOS NEMETH 1

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009

Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes

Choroidal Blood Flow Change in Eyes with High Myopia

pat hways Medtech innovation briefing Published: 15 March 2016 nice.org.uk/guidance/mib57

Comparison of handheld rebound tonometry with Goldmann applanation tonometry in children with glaucoma: a cohort study For peer review only

Glaucoma Intraocular Pressure What Will I Notice?

Immersion Vs Contact Biometery for Axial Length Measurement before Phacoemulsification

Non-contact Tonometry Synchronized with Cardiac Rhythm

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009

Assisting in Ophthalmology. Copyright 2011, 2007, 2003, 1999 by Saunders, an imprint of Elsevier Inc. All rights reserved.

Analysis of differences in intraocular pressure evaluation performed with contact and non-contact devices

CLINICAL SCIENCES. Clinical Significance of Central Corneal Thickness in the Management of Glaucoma

Diabetes, Hyperglycemia, and Central Corneal Thickness

Transcription:

The Egyptian Journal of Hospital Medicine (January 2018) Vol. 70 (8), Page 1371-1376 Relationship Between Corneal Astigmatism and Intraocular Pressure Abdulrahman E. Algarni 1, Mohammad Abahussin 2, Nuha S. Al Salameh 3, Ahmad S. Alomari 4, Yara M. Mokarki 5 1- College of Medicine, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, 2- Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh, 3- Collage of Medicine, King Saud University, Riyadh, 4- Collage of Medicine, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, 5- College of Medicine, Jazan University, Jazan University Corresponding Author: Abdulrahman E. Algarni, E-mail: Algarni004@KSAU-HS.EDU.SA ABSTRACT Aim of the work: this study aimed to investigate the relationship between the Intraocular Pressure(IOP) readings measured by Goldmaan Tonometry and the amount of corneal astigmatism in healthy young subjects and to assess the reliability of the measurements obtained with the instruments. Method: intraocular pressure measurements were obtained by Goldmann Applanation Tonometer (GAT) (Haag-Streit International, Koeniz, Switzerland), while keratometry readings for corneal curvature were obtained by an Auto-Kerato-Refractometer (ARK-KR.8800, Topcon, Tokyo, Japan). An interval was kept between the keratometric measurements and the IOP measurements. The sequence of measurement was randomized with all participants. Three measurements were taken within ten minutes and the reading was set to one immediately after any measurement were taken. Result: the average age of the volunteers was 22.4 ± 1.5 years (mean age ± SD; range: 20 26 years). Mean Intraocular Pressure (IOP) of the right and left eyes in the first visit (Paired t-test: P = 0.6471) and second visit (Paired t-test: P = 0.5805). The session one means GAT ; IOP was 16.48 ± 3.33 mmhg and 16.59 ±3.47mmHg (right and left eye respectively), while in session two it was15.714±3.10 mmhg and 15.82 ± 2.76 (right and left eye respectively). The mean corneal astigmatism was -0.24 ± 1.48D, -0.38 ± 1.53 D, right and left respectively in the first visit and -0.34 ± 1.44D, -0.40 ± 1.64D right and left eye second visit respectively. Conclusion: the GAT-IOP was less affected by the amount of corneal astigmatism and GAT-IOP was not significantly higher in eyes with greater corneal astigmatism and the repeatability results, although the differences were stastistically significant, they were not clinically significant. Keywords: glucoma corneal astigmatism, Goldmann tonometry, auto-refractometer. INTRODUCTION When the drainage tubes (Trabecular meshwork) within the eye become slightly blocked, glaucoma can occur. Glaucoma can badly affect the eye to blindness. Early treatment of glaucoma can prevent eye damage (1). When the fluid of the eye cannot drain properly, pressure builds up. This is called intraocular pressure. This can damage the optic nerve, which connects the eye to the brain and the nerve fibers from the retina (the light-sensitive nerve tissue that lines the back of the eye) (2). The corneal astigmatism was determined as the dioptric difference between the steep and flat meridians. Corneal curvature is typically measured by keratometry or videokeratography. Both methods have been shown to be repeatable in measuring spherical surfaces, such as steel balls, to within 0.25 diopter (3). For normal human corneas, keratometry has been shown to be (4) repeatable to within 0.87 D and videokeratography to within 0.50 D (5). Astigmatism is a minor condition of the eye that causes blurred vision. It occurs when the cornea is not a perfectly curved shape. Most people who wear glasses have astigmatism. Intra Ocular Pressure (IOP) measurement is the base in the diagnosis and management of most of the ophthalmology diseases. For many years Goldmann Applanation tonometry (GAT) is the method that is used to measure the IOP through Imbert Fick law, as the force required to applanate, is the same as the IOP times the applanated area (7.35 mm2 ) (6). Also, Goldmann reported that central corneal thickness (CCT) could affect the IOP. However, it was reported that this method has some errors in the measurement IOP because of corneal thickness (7) corneal curvature, or the tear film (8,9) So, it is obviously that GAT-IOP readings are influenced by corneal astigmatism [0.25 to 0.67 mmhg per diopter (D)] (10,11). PURPOSE This study aimed to investigate the relationship between the Intraocular Pressure(IOP) readings measured by Goldmaan Tonometry and the amount of corneal astigmatism in healthy young subjects and to assess the reliability of the measurements obtained with the instruments. 1371 Received: 16/12/2017 DOI: 10.12816/0044651 Accepted: 26/12/2017

Abdulrahman Algarni et al. SUBJECTS AND METHODS Eighty-four eyes of 42 healthy volunteers who had no previous history of the corneal disease or eye surgery were enrolled in this study. The average age of the volunteers was 22.4 ± 1.5 years (mean age ± SD; range: 20 26 years). Informed consent was obtained from all participants. Intraocular pressure measurements were obtained by Goldmann Applanation Tonometer GAT (Haag- Streit International, Koeniz, Switzerland), while keratometry readings for corneal curvature were obtained by an Auto-Kerato-Refractometer (ARK- KR.8800, Topcon, Tokyo, Japan). An interval was kept between the keratometric measurements and the IOP measurements. The sequence of measurement was randomized with all participants. Randomization of which eye was first measured was determined by a series of random numbers generated from the Microsoft Excel spread sheet. The patient was instructed to choose randomly any number from a group of multiple numbers. If the pick results in an odd number, the examiner starts with right eye measurements first and if even number, start with the left eye. All mesurments were performed during a normal working day to minimize the effect of the diurnal curve (12). For GAT measurements, subjects underwent IOP measurement, which was mounted on a slit lamp. A strip of fluorescein (Haag-Streit Ag, Ch-3098 Koniz, Switzerland) and a drop of 0.4% Oxybuprocaine (Novartis International AG, Basel, Switzerland) were instilled into each subject s eyes before taking measurements with their head properly positioned on the slit lamp. With the aid of the cobalt blue light of the slit lamp and ensuring that the bioprism touches the cornea in the center. The examiner looked into the tow half circles of the probe, making sure it touches the edges. Three measurements were taken within ten minutes and the reading was set to one immediately after any measurement was taken. Also, to assess the repeatability of the measurements, three consecutive measurements of IOP and corneal astigmatism were made with this device in 84 normal eyes at the same time on two different days, one week apart. Between-session repeatability was calculated. The study was done after approval of ethical board of King Saud Bin Abdulaziz university Statistical analysis All statistical analysis was performed using the GraphPad Instat software (San Diego, CA, USA). The results were expressed as mean ± SD and a value of p < 0.05 was considered statistically significant. A paired Wilcoxon matched paired test was conducted to evaluate differences in corneal astigmatism of the right eye and left eye, and a paired student t-test conducted to compare IOP averages in the right eye and left eye of each subject.to assess the magnitude of the relationship between corneal astigmatism and intraocular pressure for each eye, we plotted a linear regression graph with a coefficient of correlation indicated. For repeatability between sessions of the two GAT and Keratometry measurements, we plotted a Bland- Altman scatter graph of mean difference against average IOP and average keratometry. This study was done within two season with a weak interval. RESULTS The statistical analysis of the intraocular pressure of 42 male patients enrolled in this study were as represented in table1, showing no statistically significant difference between mean IOP of the right and left eye in session one (Paired t-test: P = 0.6471) and session two (Paired t-test: P = 0.5805). The session one mean GAT IOP was 16.48 ± 3.33 mmhg and 16.59±3.47mmHg (right and left eye respectively), while in session two it was15.714±3.10 mmhg and 15.82 ± 2.76 (right and left eye respectively). Also, corneal astigmatism (Table 2), vertical and horizontal corneal curvatures (Table 3), did not vary significantly between the right and left eye of our subjects at a 0.05 level of significance. Table 1. A paired student t-test analysis of intraocular pressure measurement values obtained by Goldmann Applanation Tonometer in session one versus session 2, with the 95% confidence intervals (CI) MEAN ± SD MEAN DIFF.±SD RANGE of PROBABILITY 95% CI Values GAT OD 16.48 ± -0.0635 ± 1.0074 10-0.6471 15.4 session 1 OS 16.59 3.329 ±3.47 0.1587 ± 0.9521 1023.3-18 0.6471 15.5 17.5 GAT OD 15.714±3.0 0.0635 ± 0.8173 10-0.5805 14.75 17.68 session 2 OS 98 15.817±2.7-0.191 ± 0.755 20.7 11-0.5805 14.92 16.68 634 20.3 16.68 The mean corneal astigmatism was -0.24 ± 1.48D, -0.38 ± 1.53 D, right and left respectively in the first visit and -0.34 ± 1.44D, -0.40 ± 1.64D right and left eye second visit respectively. 1372

Relationship Between Corneal Astigmatism Table 2. Wilcoxon matched-pairs signed-ranks test comparative analysis of right versus left eye corneal astigmatism readings as returned by Topcon RKT-8800 autoref/keratometry in sessions 1 and 2 with 95% confidence intervals (CI). CORNEAL ASTIGMATIS MEAN±SD RANGE of VALUES PROBABILI TY 95% CI M Session 1 OD -0.236 ± -3.377 0.2821-0.697 OS -0.3747 ± -3.21 0.2821-0.852 Session 2 OD -0.338 ± -3.38 0.5672-0.787 OS -0.401 ± -4.25 0.5672-0.913 Table 3. Unpaired student t-test comparative analysis of Horizontal and Vertical meridians of right versus left eye as obtained by keratometry. Keratomety Horizontal Probabilit Vertical Probability MEAN±SD MEAN DIFF±SD Horizontal y MEAN±S MEAN VERTICAL Session 1 OD 42.69±1.78-0.00016± 0.09 0.5492 42.92 ± 1.58 D DIFF.±SD 0.162±0.16 0.1256 OS 42.73± 1.81-0.03 ±0.08 0.5492 43.1± 1.73 0.0081± 0.174 0.1256 Session 2OD 42.66 ± 1.79 0.01± 0.09 0.9007 42.66 ± 1.79 0.01 ± 0.09 0.9696 OS 43.00 ± 1.58-0.01± 0.075 0.9007 42.61 ± 1.79 0.002 ± 0.035 0.9696 The linear regression graph and Pearson correlation coefficient values for OD and OS in sessions one and two were shown in fig 1- fig 4. There was a weak, but insignificant positive correlation between mean GAT-IOP and amount of corneal astigmatism measured in the right eye (r = 0.3, p = 0.0894). GAT-IOP and amount of astigmatism in left eye (r = 0.3, p = 0.0698) in session one. This was consistent in session two measurements as mean GAT-IOP was weakly correlated with the amount of corneal astigmatism in the right eye (r = 0.2, p = 0.2370). However, this was not the same with session two measurements obtained in the left eye as the GAT- IOP readings returned a significant but weak positive correlation (r = 0.3, p = 0.0307) with the amount of corneal astigmatism. Repeatability Analysis A paired t-test analysis revealed that: in the horizontal meridian, there was no statistically significant difference (p=0.4447) in keratometry values obtained in the right eye were 0.02 ± 0.20, MD±SD; 95% CI:-0.039 to 0.009), between session one and session two measurements. Difference between K-readings obtained in the horizontal meridian of the left eye in session 1 and 2 ( 0.11 ± 0.57, MD± SD; 95% CI:-0.065 to 0.287) were also not statistically significant (p = 0.2086) in the vertical meridian, the difference between session1 and session 2 mean K- readings obtained in the right eye was approaching significant level ( p = 0.06) on paired t test analysis with a mean difference ± SD of -0.08 ± 0.26 D (95% CI:-0.158 to 0.002) whereas that of the left eye was not significantly (p = 0.3915) different between sessions (0.08627±0.10, MD±SD; 95% CI: - 0.1149 to 0.2874). For the GAT-IOP, measurements were statistically significantly higher (paired t-test: p <0.05) in the first session of right (0.77 mmhg;95% CI:0.04636 to 1.493) and left (0.77mmHg; 95% CI:0.0799 to 1.475) eyes as compared to the second session. Although the differences were statistically significant, they were not clinically significant. Repeatability coefficient of the GAT was 1.97/1.87mmHg for right and left eyes in session one and 1.60 and 1.48 for the second session right and left eye respectively. 1373

Abdulrahman Algarni et al. Fig 1 Fig 2 Fig 3 Fig 4 1374

Relationship Between Corneal Astigmatism DISCUSSION The Goldmann applanation tonometer (GAT) is currently the most widely used instrument for measuring IOP and it is considered the gold standard. The GAT, however, has two disadvantages. First, the instrument probe must come in direct contact with the cornea, which can increase a patient s risk of infection. Second, use of the GAT requires a local anesthetic and some patients such as children were unwilling or unable to tolerate drug instillation. Despite these inherent disadvantages, GAT is still the accurate method of determining IOP, thus its use in this study (6). In this study, the corneal mean curvatures were not significantly different between the right and left eye (P > 0.05) of each subject, as were the GAT-IOP readings (P > 0.05), in both sessions. Overall, the IOP measurements in the right eye where between 10 and 23.3 mmhg, and in the left eye, it was between 10 and 20.7 mmhg, revealing that all of our subjects had GAT-IOP readings within the normal values in the absence of any other risk factor. We demonstrated that the mean value of GAT-IOP in the first session (16.48 ± 3.329, 16.59±3.477mmHg; OD and OS respectively) were slightly higher than the mean GAT-IOP in the second session (15.714±3.098, 15.817±2.7634mmHg; OD and OS respectively) which is in good agreement with the previous finding of Hagishima et al. (12) study with mean GAT-IOP reading of 14.2 ± 1.7mmHg. In contrast to the findings of Hagishma and cohorts (12). We demonstrated that there was a weak, but insignificant, positive correlation between GAT- IOP and corneal astigmatism in both sessions in the right and left eye, except for the second session measurements of the left eye where this correlation was significant. No possible explanation for this could be given except for instrument mechanics. About GAT-IOP readings, the cornea at the flat meridian was applanated, and then that at the steep meridian was applanated, suggesting that a larger applanation force may be necessary for eyes with a larger amount of corneal astigmatism. Although Goldmann et al. considered Attempting to overcome this dilemma by calculating the angle to the horizontal where the applanated area of an ellipse is exactly 7.35 mm (7), this may be contributed to higher GAT-IOP readings in eyes with greater corneal astigmatism. Several previous findings were in accordance with our present findings. A study of Holladay et al. (10) included 12 eyes and they used analysis of variance and Pearson product-moment correlation. They stated that horizontal orientation led to an underestimation of approximately 1 mmhg for every 4 D of corneal astigmatism when they used only the normal, horizontal measurement. Almubrad and Ogbuehi (13) in study of 30 eyes they used linear regression analysis and they noticed an increase of 1 D in corneal curvature corresponded to an increase of 0.53 mmhg and Rask et al. (11) demonstrated in a study of 50 eyes used linear regression analysis that there was not only a weak, but significant, correlation between astigmatism in 180 degrees and the IOP measured with a horizontal prism, but also a similarly significant correlation between astigmatism in 90 degrees and IOP measured with the prism in the vertical position, indicating that an increase of 1 D in corneal astigmatism leads to an increase of 0.58 to 0.67 mmhg (Rask et al.) (11). In the present study, the vertical meridian was consistently steeper than the horizontal meridian in both eyes in sessions 1 and 2. The mean horizontal corneal curvature measurements ranged from38.1 to 46.8D, while the mean vertical corneal curvature readings ranged from 40.0 to 47.8D. This demonstrated that corneal astigmatism in our subjects mostly followed the with-the-rule astigmatism pattern (vertical meridian being steeper than the horizontal meridian). The mean corneal astigmatism observed in the left eye was slightly higher (- 0.3747 ± 1.53D /-0.401 ± 1.644D) than that observed in the right eye (-0.236 ± 1.48D / -0.338 ± 1.44D) in sessions 1 and 2. To assess repeatability of the measurements, we made three consecutive measurements of GAT-IOP and corneal curvature with these devices in 84 normal eyes at the same time of day, One week apart showing that the repeatability coefficients were ± 1.92 mmhg and ± 1.54 mmhg first and second session respectively of GAT-IOP. For the corneal curvature in the two meridians, it was ± 0.17D in both sessions for the horizontal meridian, and ± 0.33D/ ± 0.13D first and second session of the vertical meridian. This means that corneal curvatures obtained by the RKT 8800 were more repeatable in the horizontal meridian than in the vertical meridian Studies have also shown good repeatability for the GAT. Ogbuehi and Almubrad reported repeatability coefficients of ± 1.8 and ± 2.1mmHg in session one and two of 1375

Abdulrahman Algarni et al. their GAT-IOP measurements in 66 normal adults, while two other studies reported ± 2.5 mmhg and ± 3.70 mmhg. In our study, the repeatability of the GAT-IOP was. This is similar to that reported by Almubrad, Ogbuehi (13). (17) Rask et al., Tonnu, P (14) and Hagishima (12) stated that clinical factors other than corneal thickness and astigmatism might contribute to measurement errors in the GAT- IOP readings. It has also been shown that central corneal thickness and the tear film may impact the IOP measurements especially those made by GAT (7). We did not perform CCT measurement which was a major limitation of this study and we cannot deny the possibility that CCT may affect the IOP measurement in our study. The small number of sample subjects was also a limitation of our study. We recommended further investigation with greater number of subjects and in subjects with high astigmatism to determine the exact effect of corneal curvature and CCT on these IOP measurements with GA. CONCLUSION In conclusion, we demonstrated that the GAT-IOP were less affected by the amount of corneal astigmatism and that GAT-IOP was not significantly higher in eyes with greater corneal astigmatism though there was a weak positive correlation. For the repeatability results, although the differences were stastistically significant, they were not clinically significant. REFERENCES 1. Leske MC (1983): The epidemiology of open-angle glaucoma: a review. Am. J. Epidemiology, 118:166-191. 2. Salim S, Linn D J, Echols J Ran Netlan P A (2009): Comparison of intraocular pressure measurements with the portable PT100 noncontact tonometer and goldmann applanation tonometry. Clinical Ophthalmology, 3: 341 344. 3. Hannush SB, Crawford SL, Waring GO, Gemmill MC, Lynn MJ and Nizam A (1990): Reproducibility of normal corneal power measurements with a keratometer, photokeratoscope, and video imaging system. Archives of Ophthalmology,108(4):539-544. 4. Quigley H (1996): Number of people with glaucoma worldwide. American Journal of Ophthalmology, 122(3):460-469. 5. Johnson DH, MD, Brandt, JD, MD et al. (2005): Lessons from the glaucoma clinical trials. Ocular Surgery News, 30:11-13. 6. Goldmann H and Schmidt T (1965): On applanation tonography. Ophthalmologica, 150:65 75. 7. Whitacre MM, Stein RA and Hassanein K(1993):The effect of corneal thickness on applanation tonometry. American Journal of Ophthalmology,115(5):592-598. 8. Shimmyo M, Ross AJ, Moy A and Mostafavi R (2003): Intraocular pressure, Goldmann applanation tension. Am. J. Ophthalmol., 136:603 613 9. Broman AT, Congdon NG, Bandeen-Roche K and Quigley HA (2007): Influence of corneal structure, corneal responsiveness and other ocular parameters on tonometric measurement of intraocular pressure. J. Glaucoma,16:581 588 10. Holladay JT, Allison ME and Prager TC (1983) Goldmann applanation tonometry in patients with regular corneal astigmatism. Am. J. Ophthalmol., 96:90 93 11. Rask G and Behndig A(2006): Effects of corneal thickness, curvature, astigmatism and direction of gaze on Goldmann applanation tonometry readings. Ophthalmic Research, 38(1):49-55 12. Hagishima M, Kamiya K, Fujimura F, Morita T, Shoji N and Shimizu K(2010): Effect of corneal astigmatism on intraocular pressure measurement using ocular response analyzer and Goldmann applanation tonometer. Graefes Arch. Clin. Exp. Ophthalmol., 248(2):257 262. 13. Almubrad TM and Ogbuehi KC(2008):The effect of repeated applanation on subsequent IOP measurements. Clin. Exp. Optom., 91(6):524-532. 14. Tonnu P (2005):The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono- Pen XL, and Goldmann applanation tonometry. British Journal of Ophthalmology, 89(7):851-854. 1376