THE. Curve THE CURVE STRIPPING TOOL

Similar documents
CURVES. Anatomically Adaptable IPR strips. Brochure Instructions for use Processing instructions

INSTRUCTIONS FOR USE AND CARE

Manufacturer s information

ProUltra ULTRASONIC SURGICAL TIPS

DentaSonic. Safe, Smart, Smooth, Time Saving, and Comfortable Proximal Tool System. orthodontics/aligner restaurative finishing prophylaxis

UNICLIP DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM FOR DENTAL USE ONLY. FISDR / F EN / 11 / updated 06/2016 1/7

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

INSTRUCTIONS FOR CLEANING, DISINFECTION AND STERILIZATION OF DFS INSTRUMENTS

BS EN ISO 14971: Risk Analysis and Risk Management Report

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

Device Technical File

MATERIAL SAFETY DATA SHEET (MSDS) Information about stainless steel for Surgical/Dental/Orthodontic Instruments.

Preparation Instructions for the CAMLOG /CONELOG Implant System

S5 Rotary Files. only. Manufacturer. Packing unit. Batch code. For professional use only (0)

Straumann ProClean Cassette. Basic Information on the

BS EN ISO 14971: Risk Analysis and Risk Management Report

1) INDICATIONS FOR USE These products have to be used only in hospital environments, clinics or dental offices by qualified dental personnel.

MANUAL FOR USE NO. 5 FLEXIBLE INTRAMEDULLARY REAMER REV ( GB ) non - sterile

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Scope This policy applies to all personnel and departments that clean, prepare and/or sterilize items intended for patient care use.

DENTATUS PROFIN DIRECTIONAL SYSTEM

ProUltra Ultrasonic Non Surgical Endo Tips

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Totally lightweight, totally flexible, totally titanium.

book Seite 1 Freitag, 21. April : fjmi^kq=omwn. Operating instructions. båöäáëü. lééê~íáåö=fåëíêìåíáçåë

Innovative revolutionary approach to root canal preparation

Velocity Orthopedics Instrument Cleaning and Sterilization

M6-C Artificial Cervical Disc Surgical Instruments

Recommendations for cleaning, disinfection and sterilization of orthopaedic instruments and devices from Swemac.

Instructions for Use. Contra-angle handpieces. Endea Endo Cursor EB-62 Endea EB-75 / EB-79. Contra-angle handpieces. Endo NiTi WD-73 M / WD-74 M

ORTHODONTIC INSTRUMENTS

Midwest E Motor. Directions For Use. Doc. No

ProphyCare. ProphyCare. By DIRECTA

EndoWave. Enhanced safety for root canal preparation. Thinking ahead. Focused on life.

book Seite 1 Mittwoch, 26. Juli : qq=ifkb=l=^áê=jçíçê. Operating Instructions / T4 LINE motor kit. båöäáëü. lééê~íáåö=fåëíêìåíáçåë

A Collection of High Quality Orthodontic Instruments

As individual as your own handwriting

Chapter 5: Checking and Maintaining Ultrasound Equipment

ÜBERCLEAN! Introducing the new STATMATIC PLUS.

BEGO PMMA Multicolor Processing information for CAD/CAM-produced restorations

Intelligent design is apparent from the detail

Altus Product description / Instructions for Use IFU 6 Rev. 1

Trimmer HSS-88 for Orthodontics. For Bite Orientated Trimming of Plaster Jaw Models

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

OPERATING INSTRUCTIONS. Orascoptic DK

SWISS INSTRUMENTS PM

SWISS INSTRUMENTS PM

Restoration & Prosthetics. Quieter, asts longer NEW

BS EN ISO 14971: Risk Analysis and Risk Management Report

INJECTION TECHNOLOGY FOR DENTURE PRODUCTION

The Sof-Lex Finishing and Polishing System 3ESPE

Reprocessing Guide. Autoclavable Arthroscope and Hardware Sterilization Tray

with Ø Ø 1.5 mm Titanium Screws distributed by ARCS Alveolar Reconstruction System E

Zirox Guidelines. Supplement to the ZIROX Instructions for Use (dated 07/05)

Syllabus for International Dental Assistants. Prepare and maintain the dental surgery, instruments, and equipment for clinical dental procedures

FOR C1 & V3 IMPLANTS STEP-BY-STEP GUIDED SURGICAL PROCEDURE

The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended.

High-end solution STEP-BY-STEP USER GUIDE

Endoscopic Technology. Operating Manual. Cannula system

Quality. Elegance. Innovation.

Instructions for use for the medical professional English

TECHNICAL GUIDE. For use with CEREC

ANATOMIC. XP-endo Finisher. optimal cleaning while preserving dentine

TONTARRA Medizintechnik GmbH. Surgical Instruments in Demand. Laminectomy Punches and Rongeurs

E-type Straight Nose Cone

Swissfloat User Manual

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

Simple. Stress-free. The Newtron Ultrasonics Series

GUIDELINES FOR PROCESSING CELTRA DUO

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

2. Gap closure and replacement of the missing tooth 35 with directly modelled bridge region 34-36

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

STEP-BY-STEP-ANLEITUNG

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

Aesculap Implant Systems

PROTAPER GOLD TM Treatment

Goldspeed EVO S1 / S1-L / M5-L /

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

IMPRESSION TRAYS. Stainless Steel Edentulous Impression Trays. 73

Hygienic Reprocessing

ProSomnus MicrO 2 Sleep and Snore Device

Star ETorque TM Attachments User Manual

SWISS INSTRUMENTS PM

EVER Pharma D-mine Pen Pen injector for Apomorphine 10 mg/ml

VarseoWax CAD/Cast GEBRAUCHSANWEISUNG INSTRUCTIONS FOR USE MODE D EMPLOI INSTRUCCIONES DE USO ISTRUZIONI PER L USO Partners in Progress

Convex Array Transducer

Linear Array Transducer

E-STATIS Motor. Operator's Manual. E-STATIS Operator s Manual Copyright 2009 SciCan. All rights reserved.

Dentium Surgery Kit Dental Implant Surgical Instrument Set

PinPrick Stimulator Set

E-STATIS. Operator's Manual. Motor. E-STATIS Operator s Manual Copyright 2009 SciCan. All rights reserved.

Patient Instruction Booklet

Aesculap Spine Instructions for use

Biomimetic Product catalogue

ProSomnus MicrO 2 Sleep and Snore Device

Press Release. Press Contact. The concept for Class II restoration Delicate preparation, rapid procedure and reliable results

D.T. LIGHT-POST. Bisco. Instructions for Use. Radiopaque Translucent Fiber Post System. Double Taper

Before & After your MATRx Study

Transcription:

THE Curve THE CURVE STRIPPING TOOL

Innovative Product Made in Germany THE Curve Mastering the perfect curve Curvable polishing strips for interproximal reduction Sterilizable, double-sided diamond instruments designed specifically for interproximal Reduction (IPR), available in six different grits. The interproximal strip can be curved easily with the thumb to match the natural interdental tooth crown shape. For polishing, there is also a smooth, extra-fine CURVES strip, providing a very fine polish with a15 μm grit. For safe use of the CURVES stripping tools without a contra-angle handpiece, a straight and angled sterilizable handle is also available.

ORDER INFORMATION ITEM DESCRIPTION ITEM # Strip (15 μm) Polishers IPR-15 Strip (25 μm) Polishers IPR-25 Strip (40 μm) Polishers IPR-40 Strip (60 μm) Polishers IPR-60 Strip (90 μm) Polishers IPR-90 Strip (40 μm) Opener/ Separator IPR-OP-40 with grit Aluminum case 1 Patient Kit Aluminum case Starter Kit 5 Aluminum case Starter Kit 6 3 Strips 15,40,60 incl. grit 5 Strips incl. Measuring gauge 6 Strips incl. Measuring gauge IPR-SET-PAT1 IPR-5 IPR-STARTER Sterilization casette for IPR-Product IPR-TRAY ITEM DESCRIPTION ITEM # Sirona T1LineEVA 11L Sirona T1LineEVA 11 NSK Ti-Max X55L NSK Ti-Max X55 SMT Mobile Unit Stainless Steel Handle Measuring Gauge Injection spray with light Max. Speed 14,000min-1 stroke 1.1mm Injection spray Max. Speed 14,000min-1 stroke 1.1mm Simple water jet, with light Max. Speed 10,000min-1 stroke 1.3mm Simple water jet Max. Speed 10,000min-1 stroke 1.3mm Portable micromotor With lithium-ion battery 1,000-30,000 rpm. torque 2.4Ncm Up to 5 hours mobile Straight and 45 angled (Strips not included) 5 gauges (0.1-0.5mm) Measuring range (0.1-1.5mm) 1111 1112 1210 1211 1324 IPR-1501 IPR-1600

User manual and full processing instructions! Damages of the contra-angle pieces due to incorrect use, such as exceeding the maximum speed, are not repaired by the manufacturer Sirona & NSK within the scope of the guarantee period.

User Manual 1. PURPOSE The strips are used for minimally invasive interdental opening of the interdental space. This application is performed to gently reduce contact points within the interdental space and to create additional space for tooth movement. 2. EXPLANATIONS The color-coded oscillating Strips are made entirely of medical steel and have a surface roughness of 15-90μm. It is important that these instruments are regularly cooled while they are being used. When using an oscillating contra-angles, please refer to the operating instructions for the specific model s highest recommended working speed as specified by the manufacturor. Oscillating angle pieces must be set to working speed before beginning the grinding process. The instrument must not be stopped during use. 3. GERNERAL INFORMATION The oscillating Strip instruments are used for controlled interdental enamel removal. They provide the required interdental gap for fixed orthodontic and aligner treatments. The metal arched frame of each strip can be curved manually with your thumb nail if neccessary. This allows you to adapt the strips to the natural shape of the patient s interdental tooth crown. 4. WORKING INSTRUCTIONS The handel of the strip is to be pushed into the contra-angle handpiece or the stainless steel holder until a firm connection is made between the oscillating contra-angle and the strip. Using the conical design of the shaft, push it until it has a tight and secure fit. 5. SAFETY PRINCIPLES The contra-angle handpiece oscillates quickly during use. Be sure to observe the manufacturer s specifications for the maximum speed of the contra-angle. Fully plan your cases before starting interproximal reduction and always use a contra-angle handpiece with a water cooling feature. Application Example Strip (15 μm) Strip (25 μm) Strip (40 μm) Strip (60 μm) Strip (90 μm) Visit us online! To learn more about all our orthodontic products plus many helpful user videos

Instruction for use The curve IPR strips require only light pressure. For narrow contact points the use of an opener / separators is recommended. Be sure that the lingual / palatal surfaces of the adjacent teeth are not damaged during this procedure. After repeating this procedure at all contact points, remove the still running contra-angle from the interdental gap and oral cavity. Turn off the contra-angle. Use the supplied gauge to ensure that the desired result has been acheived. Ater the reduction of the enamel with a large grit strip it is neccessary to proceed with finishing and polishing of the surface using the 15µm polisher strip. Customize the curve of the strip with your thumb before use, this will create an anatomical and aesthetically correct interproxmimal tooth shape for perfect finishing. Start the motor and move the strip to the slatted position to polish and contour the tooth with a cervical movement. OHNE Curves MIT Curves

Instructions for use 6. SAFETY INSTRUCTIONS Care must be taken to ensure that the device is adequately cooled at all times Do not exceed the manufacturer s specifications for the maximum speed of the device. Do not apply more that1nm pressure on the tooth surface. Do not stop the device while in the interdental gap. Interdental wedges or separators can be used in the case of overcrowding Sterilize the strips after each use. Do not cross the prosthetic equator of the tooth to avoid injuring the gingiva. CURVES are to be used only by professional staff, primarily dentists and orthodontists Failure to observe these safety instructions can lead to the destruction of the instrument as well as injury to the patient or practitioner. 7. DELIVERY CONDITION CURVES are delivered non-sterile. Suitable sterilization procedures must be used before their first use. In order to maintain the maximum efficiency of each CURVE, they are to be cleaned, disinfected and sterilized immediately after each application. 8. CLEANING AND STERILIZATION Disinfection should always be performed in an ultrasound machine. Any commercially available dental disinfecting agent can be used. After each application, CURVES are to be cleaned with a soft cleaning brush to avoid deterioration off the diamond grit. Be sure to sterilize CURVES in accordance to European standards EN 13060 with the valid revision status. Please note that High Heat Sterilization is not suitable for diamond instruments and as such is not to be used with CURVES. 9. CONTRAINDICATION Use the product only in the manner indicated in this manual to avoid unforseeable consequences. Do not swallow. Keep out of the reach of children. Do not use on patients with contagious diseases. Should CURVES come into contact with biological tissue, observe that they are disposed of correctly and immediately Strip (15 μm) Strip (25 μm) Strip (40 μm) Strip (60 μm) Strip (90 μm)

Processing Instructions PRODUCT All reusable dental instruments placed on the market by Adenta GmbH Interproximal interdental enamel reduction All instruments provided by Adenta GmbH are supplied non-sterile and must therefore be subjected to the complete preparation process before their first application, as well as after each application. The reprocessing applies to a product for a patient. WARNINGS RESTRICTIONS ON REPROCESING Frequent reprocessing has little effect on the instruments. The end of the product s life can normally be determined through wear and damage from use. As a general rule, the products should be disinfected and cleaned as quickly as possible in order to avoid the drying up of blood and other residues, which are more difficult to clean off once dry. Additionally, blood and other residues can carry disease, among other things, from Creutzfeld-Jakob disease INSTRUCTIONS Automated processing in disinfection and cleaning machines - Disinfect and clean instruments immediately after use. - Assign instruments correctly. - Water inlet temperature should not exceed 45 C. - Use only suitable cleaning disinfectants. - Use only the manufacturer s reccommended dosage, exposure time, and temperature with the chosen cleaning disinfectant - Ensure that all residues are removed during the cleaning process via thorough rinsing. - Remove the instruments from the machine immediately after the process completes - do not leave them in the machine overnight! Oscillating instruments are only conditionally suitable for machine processing and can be damaged should they sit inside for longer than neccessary. Because of this, preparation in an ultrasonic or immersion bath is preferable. - High Heat sterilization is not suitable for all diamond instruments, including CURVES CLEANING: automatic = Analogue Machine preparation in disinfection and cleaning machines see above. CLEANING: manually Equipment: Running water, cleaning agent, and a soft brush (Do not use metal brushes!). 1. Run the instrument under water until all visible contamination is gone from surface of the instrument. 2. Apply cleaning agent to all surfaces of the instrument with soft brush. Ensure that instruments with moving parts are cleaned both in the open and closed position. Pay particular attention to the cleaning of hard-to-reach areas such as locks, slots, etc. 3. Run the instrument under water again until all cleaning agent is rinsed off and all visible surface contamination js removed. It is recommended to carry out final rinse with demineralized water.

Processing instructions MAINTENANCE, INSPECTION AND TESTING - All hinges and joints of instruments should be treated with a cleaning Paraffin-based oil agent. - All instruments must be subjected to a visual inspection for damage and wear before each use. - Instruments with moving parts should be checked for smooth operation. Ensure all locking systems operate as expected. - Do not attempt to repair defective or dull instruments. Dispose of them immediately. RECOMMENDED PREPARATION FOR STERILIZATION - Single use of a standard packaging material. - Place instruments in trays provided for this purpose. Leave instruments with moving parts in the open position - Ensure that the bags are large enough for the instruments / tray so that the seal is not under tension. RECOMMENDED STERILIZATION IN PRACTICE Sterilization is carried out by validated sterilization process with moist heat according to DIN EN ISO procedures (valid revision level is to be applied). The date of sterilization or sterilization / LOT is documented on the packaging. STORAGE The storage method and the storage location corresponding to the storage time according to the recommended values according to DIN 58953 with the respectively valid revision status. NOTE The practitioner is responsible for ensuring that the processing carried out on the equipment, materials and personnel achieves the desired result. This requires routine monitoring of the process. Likewise, any deviation from provided instructions by the conditioner should be carefully evaluated for its effectiveness and possible adverse consequences. Observe the recommendations of the Robert Koch Institute published in Federal Health Gazette 4-2006 as well as possible regulations in connection with the preparation which must be taken into account. ADDITIONAL INFORMATION For further information on the preparation of reusable medical devices, please refer to the yellow brochure of the Working Group on Instrument Preparation (AKI Guidelines) - Instrument preparation in dental practice.

Curve Anatomically Adaptable IPR strips Head Office adenta GERMANY Adenta GmbH Gutenbergstrasse 9 D 82205 Gilching Germany +49 8105-73436 - 0 +49 8105-73436 - 22 Mail: info@adenta.com www.adenta.de USA Office adenta USA Adenta USA Inc PO Box 565 Richboro PA 18974 USA T. +215-942-2070 F. +215-942-2072 info@adentausa.com www.adentausa.com 01252017