Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Similar documents
Lung SBRT in a patient with poor pulmonary function

Case Study. Institution Farrer Park Hospital

Elekta Synergy Digital accelerator for advanced IGRT

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

IMRT Planning Basics AAMD Student Webinar

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

The Physics of Oesophageal Cancer Radiotherapy

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Elekta Infinity Digital accelerator for advanced treatments

CBCT of the patient in the treatment position has gained wider applications for setup verification during radiotherapy.

Elekta - a partner and world-leading supplier

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Defining Target Volumes and Organs at Risk: a common language

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Disclosures. Overview 8/3/2016. SRS: Cranial and Spine

Image Guided Stereotactic Radiotherapy of the Lung

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

Many vendors are beginning to allow couch motion during radiation delivery.

Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

iviewdose Confidence and assurance in dose delivery

VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

ICRU Report 91 Was ist neu, was ändert sich?

3D-CRT Breast Cancer Planning

SBRT TREATMENT PLANNING: TIPS + TRICKS. Rachel A. Hackett CMD, RT(T)

Overview of MLC-based Linac Radiosurgery

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,

SunCHECK Patient Comprehensive Patient QA

Hybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery

Head and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD. Barbara Agrimson, BS RT(T)(R), CMD

Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida

Treatment Planning & IGRT Credentialing for NRG SBRT Trials

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Quality assurance of volumetric modulated arc therapy using Elekta Synergy

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Intensity modulation techniques for spinal treatments and on-line VolumeView TM guidance

Implementation of advanced RT Techniques

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Clinical Implementation of SRS/SBRT

Chapters from Clinical Oncology

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

Elekta R&D Update 22 January 2015, Utrecht

brain SPINE 2 SRS Matures into breast lung spine LUNG Dr. Robert Timmerman Discusses SBRT for Inoperable Lung Cancer BRAIN

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Cyberknife Stereotactic Treatment

Collimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution in the beam junction region

Clinical experience with planning, quality assurance, and delivery of burst-mode modulated arc therapy

EORTC Member Facility Questionnaire

Radiotherapy What are our options and what is on the horizon. Dr Kevin So Specialist Radiation Oncologist Epworth Radiation Oncology

Leila E. A. Nichol Royal Surrey County Hospital

Potential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana

ART for Cervical Cancer: Dosimetry and Technical Aspects

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Page 1. Helical (Spiral) Tomotherapy. UW Helical Tomotherapy Unit. Helical (Spiral) Tomotherapy. MVCT of an Anesthetized Dog with a Sinus Tumor

Protura Robotic Patient Positioning System. for efficiency + performance

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

Asynchronization. (aka MLC interplay effect with tumor motion)

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Tania Kaprealian, M.D. Assistant Professor UCLA Department of Radiation Oncology August 22, 2015

The TomoTherapy System as a Tool of Differentiation in Quality and Marketability

Comparison of bulk electron density and voxel-based electron density treatment planning

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations

Stereotactic radiotherapy

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

The role of Radiation Oncologist: Hi-tech treatments for liver metastases

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

Measurement Guided Dose Reconstruction (MGDR) Transitioning VMAT QA from phantom to patient geometry

Dosimetric Comparison of Intensity-Modulated Radiotherapy versus 3D Conformal Radiotherapy in Patients with Head and Neck Cancer

Corporate Medical Policy

Disclosure SBRT. SBRT for Spinal Metastases 5/2/2010. No conflicts of interest. Overview

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

PEDIATRIC ORBITAL TUMORS RADIOTHERAPY PLANNING

Transcription:

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases CASE STUDY Institution: Odette Cancer Centre Location: Sunnybrook Health Sciences Centre, Toronto, Canada Radiation Oncologist: Arjun Sahgal, MD Medical Physicists: Young Lee, PhD Claudia Leavens, PhD Mark Ruschin, PhD

Summary Patient demographics: 66 year old female Treatment: HF-SRT 25 Gy delivered in 5 fractions Diagnosis: Primary disease: Lung Five brain metastases: - GTV1 - Left frontal - GTV2 - Left posterior inferior cerebellar - GTV3 - Left anterior cerebellar - GTV4 - Right occipital Disclaimer: This case study is based on the experience and application of a medical expert, and is intended as an illustration of an innovative use of Elekta solutions. It is not intended to promote or exclude any particular treatment approach to the management of a condition. Any such approach should be determined by a qualified medical practitioner. It is important to note that radiation treatments, while usually beneficial, may cause side effects that vary depending on the clinical site being treated along with other medical circumstances. The most frequent side effects are typically temporary and may include, but are not limited to, skin redness and irritation, hair loss, respiratory, digestive, urinary or reproductive system irritation, rib, bone, joint or soft tissue (muscle) pain, fatigue, nausea and vomiting. In some patients, these side effects may be severe. Treatment sessions may also vary in frequency, complexity and duration. Finally, radiation treatments are not appropriate for all cancers, and their use along with the potential benefits and risks should be discussed before treatment. - GTV 5 - Right anterior occipital Treatment planning and delivery system: Pinnacle treatment planning system version 9.2 Monaco treatment planning system version 5.1 MOSAIQ Radiation Oncology Information System version 2.5 Elekta Synergy with Agility MLC Introduction This case study forms part of a larger comparative study to observe differences between Monaco (version 5.1) and Pinnacle (version 9.2) treatment planning systems for the treatment of multiple brain metastases and spine radiosurgery using volumetric modulated arc therapy (VMAT). Young Lee, PhD There is a current debate about the treatment of brain metastases; whether to irradiate the whole brain or to treat each lesion separately 1. Since it is likely that this population of patients will present with further brain metastases in the future, it is desirable to reduce the dose to the uninvolved brain as much as possible so that new metastases can be treated. Treatment planning of multiple targets using a single isocenter, hypofractionated (HF) VMAT is technically challenging. The treatment planning systems investigated vary in terms of their optimization and dose calculation algorithms, which may produce substantially different dose distributions. Pinnacle uses collapsed cone convolution dose calculation and Monaco uses the Monte Carlo dose calculation. The purpose of this case study was to observe the differences in dose distributions produced by Monaco and Pinnacle for a challenging five brain metastases HF-VMAT case. Validation of these results with measurements will determine the accuracy of the dose calculation algorithms. 2

In our experience, planning multiple targets using VMAT with Pinnacle, we have observed several planning limitations. In order to achieve the desired high dose gradients, Pinnacle requires a long dose calculation resulting in lengthy planning time. The plan quality is also limited by the optimization algorithm s inability to accurately track the target using the jaws and MLC leaves as the treatment head moves around the patient. Specifically, certain leaf and jaw positions remain open when they should be closed (figure 1). In our planning experience to date using Monaco, we have found that the MLC leaves and jaws are better able to track targets throughout the VMAT arc. The aim of the overall study is to determine if Monaco offers any gains in terms of planning and treatment times, target conformality and dose to uninvolved brain. Our hypothesis is that Monaco will perform better than Pinnacle when planning multiple brain metastases and spine SRS, because of its ability to track the target effectively using the jaws and MLC leaves. It should be noted that the study team has significant experience in planning with Pinnacle and its functionality (5-10 years), and limited experience planning with Monaco (less than 6 months). If clinical benefit is proven, this will justify evaluating the plan quality that can be achieved using Monaco in other clinical sites. Figure 1. Stereotactic HF-VMAT of multiple brain metastases. Example where Pinnacle MLC leaves are not tracking (closing) effectively around the targets, leading to increased dose to uninvolved brain. Patient history and diagnosis The planning CT scans used for the investigation were from a 66 year old woman with lung cancer and five brain metastases in the left frontal, left posterior inferior cerebellar, left anterior cerebellar, right occipital and right anterior occipital positions (figure 2), which were treated at the Odette Cancer Centre using HF-SRT to deliver 25 Gy in 5 fractions. The patient was immobilized using a 5-point thermoplastic mask in the supine position. The CT slice thickness was 1 mm. Treatment planning Retrospective re-planning was performed with both treatment planning systems using an Elekta Agility VMAT beam model. The same energy (6MV) beam, arc geometry and single isocenter (figure 3) was used for each TPS, so that differences between the systems could be distinguished. A uniform margin of 2mm was used to create PTVs from GTVs. 3

Figure 2. Planning CT scan. Transverse and sagittal slices of 5 brain metastases. The VMAT arc arrangement used for each TPS was as follows: Couch 10 ; Gantry 180 to 310 clockwise Couch 305 ; Gantry 40 to 179 clockwise Couch 55 ; Gantry 180 to 320 clockwise Couch 350 ; Gantry 40 to 179 clockwise Figure 3. Single isocenter (light purple) placement shown in transverse and sagittal planes. Dosimetric objectives used when planning this patient for treatment were as follows: planning target volume (PTV) 100%>98%. 4

brainstem maximum dose of 18 Gy. optic chiasm maximum dose of 15 Gy. optic nerves maximum dose of 15 Gy. globes maximum dose of 10 Gy. lens maximum dose of 4 Gy. Plans were evaluated based on integral dose to brain not including the gross tumor volumes (referred to as BrainMinusGTV), target homogeneity and conformity indices. Results Pinnacle V9.2 Monaco V5.1 Figure 4. Dose distribution comparison between Pinnacle and Monaco. Figure 4 compares the dose distribution between the two treatment planning systems, in transverse and sagittal planes. Figure 5 shows the dose-volume-histograms for all five targets, as well as the BrainMinusGTV and brainstem. Finally, table 1 summarizes various plan quality metrics which were examined in our evaluation of the performance of the two treatment planning systems in this case study. 5

Figure 5. Comparison of treatment planning systems: Dose-volume-histograms of the five targets, brainstem and BrainMinusGTV PINNACLE V9.2 MONACO V5.1 Plan deemed clinically acceptable Organ-at-risk criteria met PTV coverage > 97.5% Dose Homogeneity within targets Yes, with the exception of PTV1 (proximal to brainstem): V100 82.6% Greatest difference was a 3.5 Gy decrease in D2% for PTV1 Yes, with the exception of PTV1 (proximal to brainstem): V100 90.5% Greatest difference was a 3.5 Gy increase in D2% for PTV1 Conformity Index Marginally (less than 5%) higher in 4 of 5 targets Marginally (less than 5%) lower in 4 of 5 targets DVH: BrainMinusGTV Below 3 Gy: DVH is marginally (less than 1 Gy) lower than in Monaco plan Above 12 Gy: DVH is marginally (less than 0.5 Gy) lower than in Monaco plan Mean Dose: BrainMinus GTV 499 cgy 453 cgy Between 3 Gy-12 Gy: DVH is 30-32% lower than in Pinnacle plan Mean Dose: Brainstem 10 Gy 4.0 Gy Table 1: Comparison of plan quality between Pinnacle and Monaco 6

Discussion Both plans were deemed clinically acceptable. All clinical criteria for organs-atrisk (OAR) constraints were met (table 1). PTV coverage was greater than 97.5% in all cases except for one PTV that was proximal to the brainstem and resulted in V100% of 82.6% and 90.5 % for Pinnacle and Monaco, respectively. Dose homogeneity within the target was similar for both systems, with the greatest difference being a 3.5 Gy increase in D2% for Monaco, in PTV1. Conformity indices were also similar but Monaco was marginally lower for 4/5 targets. The BrainMinusGTV dose volume histograms (DVH) were most noticeably different between 5 Gy and 10 Gy (figure 5), with Pinnacle being 30%-32% higher than Monaco. At lower and higher dose levels, the DVHs crossed and Pinnacle was marginally lower. Overall, the mean dose was slightly lower for Monaco: 453 cgy versus 499 cgy for Pinnacle. It was noted that Monaco provided greater brainstem-shielding than Pinnacle (figures 4 and 5), resulting in a mean brainstem dose of 10.0 Gy and 4.0 Gy in Pinnacle and Monaco, respectively. In terms of ease of use, the Windows-based Monaco software is very user friendly and found to be easier to navigate than Pinnacle for new users. Due to the ability to prioritize IMRT objectives prior to optimization in Monaco, the planning process was also found to be more user-friendly. Through the use of well-structured templates, it is felt that the overall planning process using Monaco may take less time. This finding needs to be validated with a larger study. The fusion tool in Monaco is easy to use and valuable for comparing dose distributions from different planning systems. Conclusion Overall, both treatment planning systems produced clinically acceptable dose distributions. Monaco may potentially result in lower normal tissue dose as exhibited by the substantial reduction in DVH between 5-10 Gy for BrainMinusGTV, but this needs to be validated in a larger patient series and findings validated with measurement. Not considered in the present study were investigations of different beam, arc and isocenter arrangements, nor patient-specific quality assurance, which are necessary for clinical implementation. As the treatment of multiple metastases expands, the selection of a treatment planning system that can generate multiple target plans quickly, accurately and efficiently is increasingly important in order to meet clinical and workload needs. Comparison between the two treatment planning systems continues for single, two, three and four target brain metastases and spine SBRT plans. 7

ABOUT ELEKTA A human care company, Elekta pioneers significant innovations and clinical solutions harnessing both external and internal radiation therapy for treating cancer and brain disorders. Elekta provides intelligent and resource-efficient technologies that improve, prolong and save patient lives. We go beyond collaboration, seeking long-term relationships built on trust with a shared vision, and inspiring confidence among healthcare providers and their patients. REFERENCES [1] Sahgal A, Aoyama H, Kocher M, et al (2015). Phase 3 trials of stereotactic radiosurgery with or without whole-brain radiation therapy for 1 to 4 brain metastases: individual patient data meta-analysis. Int J Radiat Oncol Biol Phys. 91(4):710-7. doi: 10.1016/j.ijrobp.2014.10.024. This case study is based on the experience and application of a medical expert, and is intended as an example of how the product can be used in a particular scenario. It is not intended to promote, recommend, or exclude any treatment modality or methodology, or any particular approach to the management of a condition, either generally or with regard to specific anatomical structures. Treatment parameters and approaches should be determined by a qualified medical practitioner. The clinical and technical results represented in the case study are not guaranteed and may vary in different scenarios. It is important to note that radiation treatments, while usually beneficial, may also cause side effects that vary depending on the area being treated along with other medical circumstances. The most frequent side effects are typically temporary and may include, but are not limited to, skin redness and irritation, hair loss, respiratory, digestive, urinary or reproductive system irritation, rib, bone, joint or soft tissue (muscle) pain, fatigue, nausea and vomiting. In some patients, these side effects may be severe. Treatment sessions may also vary in frequency, complexity and duration. Finally, radiation treatments are not appropriate for all cancers, and their use along with the potential benefits and risks should be discussed before treatment. Art. No. LPRMON06102015 v1 Elekta. All rights reserved. No part of this documents may be reproduced in any form without written permission from the copyright holder. All trademarks of Elekta products are the property of Elekta.