ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

Similar documents
ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

ACE. Intelligent Solutions for Method Development. Method Development Kits. ACE UHPLC and HPLC Columns. a a

ACE Excel UHPLC Columns

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Hyper-fast & Super-rugged

UHPLC / HPLC Columns Developed for Mass Spectrometry

ACE C18-AR Use the Power!

Restek Ultra II HPLC Columns

Analytical and Preparative SFC Columns

Sepax Technologies, Inc.

Agilent Technologies Prep LC Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Protect your expensive HPLC and UHPLC columns from premature failure with MAC-MOD Pre-Column Filters

C30 ISOMERS HAVE MET THEIR MATCH

Thermo Scientific Hypersil BDS Columns

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

PEEK SS Columns & Guard Columns

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Ultra Columns. also available. ordering note

SeQuant ZIC -HILIC For all who expect more...

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

Purification - Flash Chromatography

Ultra Columns HPLC COLUMNS

InertSustainBio C18. Rapid Separations of Proteins and Peptides

Comparison of a UPLC Method across Multiple UHPLC Systems

Fortis Method Development Options

SeQuant ZIC -HILIC For all who expect more...

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

176 YMC Chiral Columns

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Am I getting the very best value from my UHPLC analyses?

Roc On with These Dependable LC Columns

YMC-Triart C18. Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

ACE ACE. HPLC and UHPLC Columns. Product Catalog

HPLC. Varian Dynamax Preparative HPLC Columns

Chapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:

LC Columns with Liquid Separation Cell Technology

Choosing Preparative Columns

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

Ultimate Core Performance to Maximize Your Investment

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Reversed-Phase Columns (Other than ODS)

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

11:00 a.m. EST Telephone Number: Chair Person: Tim Spaeder

PEEK Columns & Guard Columns

ACE ACE. HPLC and UHPLC Columns. Product Catalogue

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Normal Phase HPLC Column COSMOSIL SL-II

Core-Shell Technology for Proteins and Peptides

A New Era in SFC Column Technology

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Raptor HILIC-Si: Simplify the Switch to HILIC

GlycanPac AXR-1 Columns

Kromasil The way to peak performance in liquid chromatography

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

HPLC Column for Structural Isomers COSMOSIL Cholester

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Studies on Stationary Phase Selectivity for Solid-Core Particles

Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis

Columns for HPLC. Columns for HPLC

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Raptor HILIC-Si: Simplify the Switch to HILIC

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

2012 Waters Corporation 1

Preparative Chromatography Meets UHPLC

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Calibration Standards

Dikma Technologies Inc.

Columns for HPLC. Columns for HPLC

GlycanPac AXH-1 Columns

Purification - Flash Chromatography

The Raptor HILIC-Si Column

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

YMC-Triart C18. Multilayer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

The LC Column Playbook

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

New HPLC Column Options for UHPLC

HPLC Columns. HPLC Accessories HPLC Column Test Mixes Reference Books... HPLC Applications...

Unequalled durability against water elution. % tr

Overview on YMC Column Hardware and Phases

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

Dikma Technologies Inc.

Overview on YMC Column Hardware and Phases

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

HIGH PERFORMANCE SEPARATION PHASES

SPE Cartridges. All Finneran Products Are Certified. Conditioning Sample application Wash Elution

Transcription:

ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method development High efficiency µm, µm, µm and 0µm particles Ultra-inert for maximum performance and reproducibility Enhanced Selectivity ACE ACE CN-ES Combining CN polar selectivity with enhanced UHPLC and HPLC hydrophobicity s

ACE CN-ES Mechanism of Separation Strength of Interaction Fig. - ACE CN-ES Provides Alternative Selectivity Application # 70 Dipole-dipole interactions Hydrophobic binding interactions Target Analytes Strong Strong Polar and non-polar analytes Analytes with double and triple bonds Analytes differing in hydrophobicity Polar molecules having insufficient retention on traditional CN bonded phases ACE Excel CN-ES ACE CN-ES phase provides complete separation due to hydrophobic AND dipole-dipole interactions 0 Recommended Separations Mixtures of very polar, polar and non-polar analytes Suitable for NP and RP separations Separations where traditional CN bonded phases show insufficient stability/lifetime Applications where a typical C8 column does not provide adequate separation As an orthogonal phase in method development ACE Excel CN,, CN phase shows insufficient resolution (greatly reduced hydrophobic interaction) 0 ACE Excel C8 C8 phase provides insufficient resolution (no dipole-dipole interaction), If ACE does not outperform the column you are currently using, simply contact us for a full refund and keep the ACE column FREE F CHARGE. 0 Sample: ) metronidazole ) benzyl alcohol ) hydrochlorothiazide ) vanillin ) methyl paraben ),-dinitrobenzene Mobile Phase: A = 0.% formic acid in H B = 0.% formic acid in 0:0 MeH/H Gradient: - 00% B in minutes Dimensions: 0 x.mm Flow Rate: 0.0ml/min Temperature: 0 C Wavelength: nm

Why does ACE CN-ES provide alternative selectivity? Combines a polar CN group with an extended spacer that provides retention similar to a C8 column Extended spacer technology additionally provides increased column lifetime compared to traditional CN bonded phases with short alkyl spacer (typically C /propyl) CN Phase ACE CN-ES C8 Phase R Si R CN group for polar interaction Short alkyl spacer (typically C /propyl) results in low hydrophobicity and reduced stability R Si R Extended spacer technology provides enhanced hydrophobic interaction Extended spacer also increases column lifetime and stability Ultra inert, ultra pure, ultra reproducible ACE silica R Si R C8 group for hydrophobic interaction Dipole-dipole interaction ACE CN-ES provides multiple modes of interaction (dipole-dipole AND hydrophobic interactions) Hydrophobic interaction ACE CN-ES provides retention similar to a C8 column Fig. - Separation of Neutral Compounds under RP conditions Application # 70 ACE Excel CN-ES ACE CN-ES phase offers increased retention due to contribution from the extended spacer 0 8 0 8 0 ACE Excel C8 C8 group provides hydrophobic interaction 0 8 0 8 0 ACE Excel CN CN phases with short alkyl spacer group show minimal hydrophobic retention 0 8 0 8 0 Sample: ) uracil ) dimethyl phthalate ) toluene ) biphenyl ) phenanthrene Mobile Phase: 0:0 MeCN/H Dimensions: 0 x.mm Flow Rate:.00ml/min Temperature: C Wavelength: nm

Alternative Selectivity with MeH or MeCN Fig. - Advantages of Multi-Mode Interactions on Separations Application # 70 0 ACE Excel CN-ES 7 8 Multi-Mode interaction with hydrophobic AND dipole-dipole interactions 0 8 0 0 ACE Excel C8 7 8 Hydrophobic interaction (no dipole-dipole interaction) 0 8 0,,, ACE Excel CN 7, 8 0 Dipole-dipole interaction (reduced hydrophobic interaction) 0 8 0 Sample: ),-dihydroxybenzene ) catechol ) hydrochlorothiazide ) oxyprenolol ) salicylic acid ) myricetin 7) piroxicam 8),-dinitrobenzene ) tolmetin 0) -naphthol ) piperine ) diflunisal ) propylbenzene ),,-trichlorobenzene Mobile Phase: A = 0.% formic acid in H B = 0.% formic acid in MeCN Gradient: - 00% B in 0 minutes Dimensions: 00 x.mm Flow Rate: 0.0ml/min Temperature: 0 C Wavelength: 0nm Fig. - Fast Gradient with NSAIDs Application # 70 -Acetamidophenol NH H CH ACE Excel CN-ES 0 Acetanilide H C NH NH Salicylamide H ACE Excel C8 H 0 Aspirin CH, ACE Excel CN Phenacetin H C NH CH 0 H Sample: ) -acetamidophenol ) acetanilide ) salicylamide ) aspirin ) phenacetin ) salicylic acid Mobile Phase: A = 0.% formic acid in H B = 0.% formic acid in MeH Gradient: - 8% B in.7 minutes, hold at 8% B until minutes Dimensions: 0 x.mm Flow Rate: 0.0ml/min Temperature: 0 C Wavelength: 0nm Salicylic acid H

Exploit Enhanced Selectivity for UHPLC Fig. - Steroids by UHPLC Application # 70 ACE Excel CN-ES 7 8 ACE CN-ES provides complete separation due to hydrophobic AND dipole-dipole interactions 0 ACE Excel C8, C8 phase provides insufficient resolution (no dipole-dipole interaction) 7 8 0 ACE Excel CN 7 8 CN phase shows insufficient resolution (reduced hydrophobic interaction) 0 Sample: ) cortisone ) corticosterone ) α-hydroxyprogesterone ) cortisone--acetate ) -ketoprogesterone ) β-estradiol 7) 7α-estradiol 8) 7α-ethynylestradiol ) estrone Mobile Phase: A = 0.% formic acid in H B = 0.% formic acid in MeCN Gradient:.% B in minutes Dimensions: 0 x.mm Flow Rate: 0.0ml/min Temperature: 0 C Wavelength: 0nm ACE CN-ES is additionally compatible with Normal Phase conditions Fig. - Retention Comparison with Substituted Aromatic Compounds under NP Conditions Application # 70 ACE Excel CN-ES ACE CN-ES provides separation similar to a CN column 0.0 0.0.0.0.0.0.0 7.0 8.0 ACE Excel CN Dipole-dipole interaction provides separation 0.0 0.0.0.0.0.0.0 7.0 8.0,, ACE Excel C8 No dipole-dipole interaction to enable separation 0.0 0.0.0.0.0.0.0 7.0 8.0 Sample: ) butylbenzene ) methyl benzoate ) nitrobenzene Mobile Phase: 0:0 heptane/ethyl acetate Dimensions: 0 x.mm Flow Rate:.00ml/min Temperature: C Wavelength: nm

Product Availability and Specifications Phase Functional Group Endcapped ACE CN-ES Cyano with proprietary extended alkyl spacer Particle Size (µm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) Maximum ph Range 00% Aqueous Compatible USP Listing Yes,,, 0 00 00..0-8.0 a Yes L0 a For optimum column lifetime, a ph range of -8 is recommended. To increase column lifetime at higher ph, organic buffers, low buffer concentrations, high % organic solvent and low temperatures must be considered. Further information is contained within A Guide to HPLC and LC/MS Buffer Selection by John Dolan please contact your distributor to request your FREE copy or visit. ACE Excel µm CN-ES UHPLC/HPLC s (supplied in dual compatible UHPLC/HPLC Excel hardware format with 000bar/000psi pressure limit) 0mm 0mm mm 0mm 7mm 00mm mm 0mm.mm EXL-0-00U EXL-0-00U EXL-0-0U EXL-0-00U EXL-0-70U EXL-0-00U EXL-0-0U EXL-0-0U.0mm EXL-0-00U EXL-0-00U EXL-0-0U EXL-0-00U EXL-0-70U EXL-0-00U EXL-0-0U EXL-0-0U.mm EXL-0-0U EXL-0-0U EXL-0-U EXL-0-0U EXL-0-7U EXL-0-0U EXL-0-U EXL-0-U ACE Excel µm CN-ES UHPLC/HPLC s (supplied in dual compatible UHPLC/HPLC Excel hardware format with 000bar/000psi pressure limit) 0mm 0mm mm 0mm 7mm 00mm mm 0mm 0mm.mm EXL--00U EXL--00U EXL--0U EXL--00U EXL--70U EXL--00U EXL--0U EXL--0U EXL--0U.0mm EXL--00U EXL--00U EXL--0U EXL--00U EXL--70U EXL--00U EXL--0U EXL--0U EXL--0U.mm EXL--0U EXL--0U EXL--U EXL--0U EXL--7U EXL--0U EXL--U EXL--U EXL--U ACE Excel µm CN-ES UHPLC/HPLC s (supplied in dual compatible UHPLC/HPLC Excel hardware format with 000bar/000psi pressure limit) 0mm 0mm mm 0mm 7mm 00mm mm 0mm 0mm.mm EXL--00U EXL--00U EXL--0U EXL--00U EXL--70U EXL--00U EXL--0U EXL--0U EXL--0U.0mm EXL--00U EXL--00U EXL--0U EXL--00U EXL--70U EXL--00U EXL--0U EXL--0U EXL--0U.mm EXL--0U EXL--0U EXL--U EXL--0U EXL--7U EXL--0U EXL--U EXL--U EXL--U ACE µm CN-ES Semi-Prep and Preparative HPLC s (supplied in HPLC hardware format with 7bar/000psi pressure limit) 0mm 7mm 00mm mm 0mm 0mm 7.7mm ACE--008 ACE--708 ACE--008 ACE--08 ACE--08 ACE--08 0mm ACE--00 ACE--70 ACE--00 ACE--0 ACE--0 ACE--0.mm ACE--00 ACE--70 ACE--00 ACE--0 ACE--0 ACE--0 ACE 0µm CN-ES Analytical, Semi-Prep and Preparative HPLC s (supplied in HPLC hardware format with 7bar/000psi pressure limit) 0mm 7mm 00mm mm 0mm 0mm.mm ACE--0 ACE--7 ACE--0 ACE-- ACE-- ACE-- 7.7mm ACE--008 ACE--708 ACE--008 ACE--08 ACE--08 ACE--08 0mm ACE--00 ACE--70 ACE--00 ACE--0 ACE--0 ACE--0.mm ACE--00 ACE--70 ACE--00 ACE--0 ACE--0 ACE--0 0mm ACE--00 ACE--70 ACE--00 - ACE--0 ACE--0 ACE CN-ES Capillary and Nano HPLC s ACE CN-ES capillary and nano columns are available in mm, 0.mm (00µm), 00µm, 00µm and 7µm internal diameters with µm, µm and 0µm particle sizes. Please enquire for further information.

UHPLC and HPLC Method Development Kits Method development kits enable the optimum bonded phase for an application to be identified. ACE columns are available with a unique range of highly selective phases in µm, µm, µm and 0µm particle sizes, specially developed for challenging UHPLC and HPLC applications. The availability of a range of phases offering complementary selectivity enables resolution to be maximised, improves the chances of impurity detection and increases the speed at which methods can be systematically developed. Please enquire for further information. UHPLC and HPLC Accessories UHPLC Connectors Pressure rating >700 bar (>000 psi) Compatible with all UHPLC systems Compatible with all UHPLC column brands Eliminates poor connections Innovative reusable design Wrench Flat ¼ (0.cm) Proprietary PEEK cone Reuseable column connector with 0- threads for / D tubing ACE Excel UHPLC Connector (p/n EXL-CC0, 0 pack) All UHPLC column brands require correct installation in order to realise maximum column efficiency. To avoid connection problems, permanently swaged fittings are not recommended as they do not allow free movement between the tubing, fitting and column inlet on installation. This can result in a poorly connected column that shows unexpected peak tailing due to the introduction of extra column volume (dead volume) to the system. Alternatively, a leak at the inlet fitting connection may be observed. ACE Excel UHPLC Connectors (p/n EXL-CC0, 0 pack) enable the inlet end of UHPLC columns to be correctly installed every time. Their unique reuseable design ensures that they maintain a 700 bar (000 psi) pressure rating with repeated use, yet do not permanently swage onto the inlet tubing. To maximise the lifetime of the fitting, the use of torque wrench (p/n EXL-TW) is required. At the outlet end of the UHPLC column (where pressure demands are lower but a correct connection remains important), ACE Fingertight HPLC Connectors (p/n ACE-CC0, 0 pack, see overleaf) may alternatively be used. Note: For inlet connections onto a Waters Acquity system (containing a Waters Acquity / fitting and ferrule on the inlet tubing) the use of a pre-column filter incorporating the unique Waters Acquity column port profile is alternatively recommended (p/n EXL-PCF0/ACQ - 0 pack) to ensure maximum compatibility with the Waters Acquity system fittings. UHPLC Pre-column Filters To further extend column lifetime under UHPLC conditions up to 000 psi (000 bar), ACE Excel UHPLC Pre-column filters are recommended. By one estimate, over 70% of the failures of UHPLC and HPLC columns are caused by inlet frit plugging. Due to their ultra low dispersion design, column performance and retention remain unaffected, whilst the column inlet is protected from blockage. ACE Excel UHPLC Pre-column filters can be installed on any brand of UHPLC column in seconds. Simply finger tighten initially, then wrench tighten a further ¼ turn. 000 bar (000 psi) pressure rating Eliminates poor connections Compatible with all UHPLC column brands Compatible with all UHPLC systems including Waters Acquity Two UHPLC pre-column filter options are available, for compatibility with all UHPLC systems: ACE Excel UHPLC Pre-column Filters (p/n EXL-PCF0, 0 pack) are compatible with almost all UHPLC system configurations. For inlet connections onto a Waters Acquity system (containing a Waters Acquity / fitting and ferrule on the inlet tubing) the use of a pre-column filter incorporating the Waters Acquity column port profile is alternatively recommended (p/n EXL-PCF0/ACQ - 0 pack) to ensure maximum compatibility. ACE Excel UHPLC Pre- Filter (p/n EXL-PCF0, 0 pack) ACE Excel UHPLC Pre- Filter (Waters Acquity System Compatible) (p/n EXL-PCF0/ACQ, 0 pack) 7

UHPLC and HPLC Accessories (continued) HPLC Connectors Fingertight to 0 bar (000 psi) Reuseable and simple to install Eliminates poor connections Compatible with all HPLC column brands and instruments ACE Fingertight HPLC Connectors (p/n ACE-CC0, 0 pack) are recommended for the connection of both the inlet and outlet ends of HPLC columns. Manufactured from premium quality PEEK, the fittings simply hand tighten to provide a perfect column connection, and are pressure rated to 0 bar/000 psi. ACE Fingertight HPLC Connectors may additionally be used at the outlet end of UHPLC columns, where pressure demands are lower but a correct connection remains important. ACE Fingertight HPLC Connector (p/n ACE-CC0, 0 pack) HPLC Guard Cartridges Pressure rated to 7 bar (000 psi) Simple to install and exchange Increase HPLC column lifetime Guard cartridges are recommended to prevent both inlet frit blockage and irreversible sample adsorption onto the top of the column. Guard cartridges are available for all ACE HPLC columns from nano and capillary dimensions through to preparative scale. For assistance identifying the appropriate guard for the column selected, please contact our Technical Support Department at info@ace-hplc.com HPLC Pre-column Filters Pressure rated to 0 bar (000 psi) Simple to install and replace Effective low cost column protection Compatible with all HPLC column brands ACE Analytical HPLC Pre-column Filter (p/n ACE-CS0, 0 pack) ACE Microbore HPLC Pre-column Filter (p/n ACE-HP0, 0 pack) As an alternative to guard cartridges, pre-column filters may be used to protect the column inlet frit from blockage. Due to their ultra low dispersion design, column performance and retention remain unaffected. ACE HPLC pre-column filters utilise a PEEK fingertight design that connects directly into any / 0- internal thread column inlet, and are thus compatible with all HPLC column brands. For.0 -.mm id HPLC columns, the use of ACE Analytical HPLC Pre-column Filters (p/n ACE-CS0, 0 pack) are recommended. For.mm id HPLC columns, the use of ACE Microbore HPLC Pre-column Filters (p/n ACE-HP0, 0 pack) are recommended. ACE HPLC pre-column filters are simply hand tightened into the column inlet to achieve a pressure rating of 0 bar (000 psi). If higher pressure rating is required, ACE Excel UHPLC Pre-column Filters (suitable for use up to 000 bar/000 psi) are alternatively recommended. ACE and Excel are registered trademarks of Advanced Chromatography Technologies Limited. Comparative data may not be representative of all applications. Advanced Chromatography Technologies Limited acknowledges the registered and unregistered trademarks of Victrex Plc and Waters Corporation and has no association with either company. ACE UHPLC and HPLC columns are available through our international distributor network Available from: ACE UHPLC and HPLC s Advanced Chromatography Technologies Limited, Berry Street, Aberdeen, AB HF, Scotland Tel: + (0) 70 Fax: + (0) 8 0 email: info@ace-hplc.com 00000Q/07/00-A