CLAMPLESS BEATING HEART SURGERY PRODUCT FAMILY

Similar documents
LINEAR 7.5Fr. IAB Catheter

Octopus Nuvo TISSUE STABILIZER. Take the next step with MICS CABG

SENSATION and CS300 Smaller meets faster. IABP System

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip.

Cardioplegia Circuit Products { ANTEGRADE}

Heart may be rotated but not compressed

Off-Pump Cardiac Surgery is not Dead

ThruPort Ergonic Minimal Incision Instrumentation

Innovative Heart Stabilization System Experience the New Standard in Precision and Control

HLS CANNULAE SOLUTIONS FROM TIP TO TIP

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

EXTENSION DEVICES FOR MAQUET OR TABLES

Cardioplegia Circuit Products { CARDIOPLEGIA ADAPTERS}

MICS CABG. Putting the future of MICS in your hands today

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE

OPCAB IS NOT BETTER THAN CONVENTIONAL CABG

CONVENTIONAL ADULT CANNULAE

CONVENTIONAL ADULT CANNULAE

Differentiation of Emboli

Global Myocardial Protection

Strategies for Maintaining Hemodynamic Stability

Challenging anatomies demand versatility.

Uncompromised Exposure

MITROFLOW VALSALVA CONDUIT TM

2006 Annual Report. Anastomosis Made Simple

Easier minimally invasive technology to deliver the optimal vessel for CABG.

Off-pump coronary artery bypass graft (OPCAB) constitutes

PHANTOM FUKUSHIMA NEUROLOGICAL HOLDING SYSTEMS

Uncompromised Exposure

Talent Abdominal Stent Graft

Extracorporeal Circuit Cannulae { VENOUS}

Access More Patients. Customize Each Seal.

Peel-Apart Percutaneous Introducer Kits for

About OMICS International Conferences

Surgical Technique Guide

MICS & FEMORAL CANNULAE

MARKING RING VEIN GRAFT VALVE INSTRUMENTS. Hook, Valve. TFX SURGICAL SPECIALTIES Phone Toll Free: Fax:

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

The Challenge of Accurately Stenting Aorto-Ostial Lesions

Ruby Coil. Large Volume Detachable Coils

Atrium Advanta V12. Balloon Expandable Covered Stents

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

Balloon Expandable Covered Stents. Suddenly a Crowded Space

VirtuoSaph Plus. Endoscopic Vessel Harvesting System. Designed for Safety and Efficiency

EndoRelease ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM

Vascular V12. Covered Stent. The New Standard of Care

AXS Catalyst Distal Access Catheter

Durable outcomes. Proven performance.

CLARIVEIN INFUSION CATHETER

Declaration of conflict of interest NONE

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

RECOMMENDED INSTRUCTIONS FOR USE

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

BTK Case Studies Joseph Cardenas, MD AZ Heart & Vascular, Yuma, AZ

System.

TurboHawk. Plaque Excision System

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Proven Performance Through Innovative Design *

Off Pump CABG is Dead. Hopeman Lecture Debate T. Brett Reece, MD September 10, 2007

Technique Guide. Cranial Clamps with Application Instrument. Quick and stable fixation of cranial bone flaps following a craniotomy.

NIRxcell CoCr Coronary Stent System

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

DISTRACTION PRODUCT OVERVIEW. For a wide variety of facial applications

PERFORMANCE YOU CAN TRUST. EverFlex Self-expanding Peripheral Stent with Entrust Delivery System

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

Extramedullary Tibial Preparation

Adult Cannulae. product catalog

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

FLUID MANAGEMENT FLUID MANAGEMENT

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

HIGH-DEFINITION HYSTEROSCOPY FOR A HIGH STANDARD OF CARE.

ER REBOA Catheter. Instructions for Use

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

MSP TM Metatarsal Shortening System. Surgical Technique

Acute dissections of the descending thoracic aorta (Debakey

Low Profile Neuro Plating System. Surgical Technique

Trilogy Acetabular System

Final published version:

Trilogy Acetabular System

Product specifications Mattress replacement alpha active 4 Mattress replacement Pump GetinGe GrouP arjohuntleigh GetinGe MaQuet arjohuntleigh

Minimally invasive direct coronary artery bypass for left anterior descending artery revascularization analysis of 300 cases

SUBGLOTTIC SECRETION REMOVAL:

Polaris Deformity System Trivium Derotation System

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

FIND YOUR IDEAL CANNULAE CATALOG. Designed for your smallest patients

Safe, simple and reliable closed blood sampling for effective patient blood management.9,14

Saphenous Vein Autograft Replacement

MEMO 4D Reshaping Mitral Repair

Next Generation MICS Instrumentation

OPTIONAL/ADDITIONAL INSTRUMENTS

Initial Experience with the Enclose Proximal Aortic Anastomosis Device during Off-Pump Coronary Artery Bypass: An Alternative to Aortic Side Clamping

What is TAVR? Transcatheter Aortic Valve Replacement

Surgical Table Accessories

Integra SURGICAL TECHNIQUE. MemoFix Super Elastic Nitinol Staple System. Super Elastic Nitinol Staple System

designed to advance the treatment of hip fractures.

Integra MicroFrance Laparoscopic Instruments for Urology Procedures *

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

Transcription:

CLAMPLESS BEATING HEART SURGERY PRODUCT FAMILY

2 CLAMPLESS BEATING HEART MAQUET Medical Systems USA A comprehensive solution designed To optimize outcomes ACROBAT-i OFF-PUMP SYSTEM HEARTSTRING III Seal Loader and Delivery Device, Aortic Cutter, and Seal ACROBAT-i OFF-PUMP SYSTEM HEARTSTRING III PROXIMAL SEAL SYSTEM Enhanced Visibility and Control. The ACROBAT-i combines sleek form with superb function and enables surgeons to more easily and confidently deliver the benefits of beating heart surgery. It incorporates the preferred features from the ACROBAT and XPOSE product family: proven stability, strength and flexibility! Low Profile Mount: Stabilizer mount maintains a constant low profile even at extreme arm positions for an optimized work area Increased Visibility: Stabilizer allows a vertical drop into the chest cavity and provides 180º side-to-side range of motion of the arm Increased workspace: Streamlined locking lever and Integrated channels secure tubing and decrease workspace cluttering Do more clamp less. HEARTSTRING III brings proximal anastomotic technology into the future. A hemostatic seal enables surgeons to eliminate partial occlusion clamps and minimize aortic manipulation that can lead to complications. Safety: Helps avoid embolic release and reduces the potential for neurologic complications Patency: Allows use of the surgeon s own hand-suturing technique for optimal anastomotic quality and procedural flexibility Ease of use: The innovative loading device makes HEARTSTRING III Seal placement fast and easy

MAQUET Medical Systems USA CLAMPLESS BEATING HEART 3 AXIUS Blower/Mister and Coronary Shunts ACTIVATOR II Drive Mechanism AXIUS BEATING HEART ACCESSORIES ACTIVATOR II Drive Mechanism See more clearly. The AXIUS Coronary Shunt and Blower/ Mister help to optimize operative conditions during coronary revascularization procedures. Create a clear work area: Shunt provides a bloodless field at the anastomotic site Minimize ischemia: Shunt helps maintain distal perfusion Maintain moisture: Blower/Mister helps prevent dessication of graft Increase visibility: Blower/Mister gently displaces blood with a controlled flow of saline and CO2 Optimize Access. The ACTIVATOR II Drive Mechanism is a reusable, stainless steel retractor used in combination with the ACCESSRAIL Platform to open the sternum, providing access and direct visualization into the thoracic cavity. Flexibility: Choice between Standard Blades or Deep Blades to accommodate different anatomies which easily attach to the ACTIVATOR II Drive Mechanism Clear workspace: Enables clean organization of pericardial sutures and also accommodates the Stabilizers and Positioners used on the beating heart

MAQUET Medical Systems USA CLAMPLESS BEATING HEART 4 product ordering information Offer more patients the proven benefits of clampless beating heart surgery: reduced mortality, improved cognition, and more rapid recovery 1-3. MAQUET Medical Systems offers an integrated system that complements a range of surgical approaches. HEARTSTRING Proximal Seal System allows clampless anastomoses, easy use with hand-suturing, and reduced risk of embolic release 4 ACROBAT Off-Pump System offers uncompromising strength and stability XPOSE Access Device maintains hemodynamics while providing a simple way to position target vessels AXIUS Beating Heart Accessories help optimize operative conditions and maintain perfusion MAQUET Medical Systems strives to be the gold standard in surgical technology, delivering exceptional stability, flexibility, and visibility. For more information about the HEARTSTRING III Proximal Seal System and the complete line of clampless beating heart surgery devices, contact a MAQUET representative or visit www.maquetusa.com. Description Code HEARTSTRING III Proximal Seal System HEARTSTRING III Seal, Delivery Device, Loader, and 4.3 mm Aortic Cutter HSK-3043 HEARTSTRING III Seal, Delivery Device, Loader, and 3.8 mm Aortic Cutter HSK-3038 HEARTSTRING III Seal, Delivery Device, and Loader HS-3045 HEARTSTRING III Seal, Aortic Cutter, 3.8 mm AC-3038 HEARTSTRING III Seal, Aortic Cutter, 4.3 mm AC-3043 XPOSE Access Device XPOSE 3 Device XP-3000 XPOSE 4 Device XP-4000 ACROBAT-i Positioner XP-5000 ACROBAT Off-Pump Systems and ULTIMA OPCAB System ACROBAT-i Stabilizer OM-10000 ACROBAT SUV Stabilizer OM-9000 ACROBAT V Vacuum Stabilizer OM-9100 ACROBAT-i Positioner and Stabilizer XO5-10000 XPOSE 3 + ACROBAT SUV Stabilizer XO3-90000 XPOSE 4 + ACROBAT SUV Stabilizer XO4-90000 XPOSE 3 + ACROBAT V Stabilizer XO3-9100 XPOSE 4 + ACROBAT V Stabilizer XO4-9100 Beating Heart Accessories AXIUS Blower/Mister CB-1000 ACROBAT-i Blower/Mister CB-2000 AXIUS Coronary Shunt Tip Diameter (mm) Standard Length (mm) Long Length (mm) Code 1.00 16.25 OF-1000 1.25 16.25 OF-1250 1.50 16.25 20.25 OF-1500/ OF-1500L 1.75 17.50 OF-1750 2.00 18.00 22.00 OF-2000/ OF2000L 2.25 18.00 OF-2250 2.50 19.00 OF-2500 2.75 19.50 OF-2750 3.00 20.00 OF-3000 3.50 24.00 OF-3500 ACTIVATOR II Drive Mechanism ACTIVATOR II Drive Mechanism ACCESSRAIL Platform Standard Blades ACCESSRAIL Platform Deep Blades UA-5001 SB-1000 DB-1000 References: 1. Diegeler A, Hirsch R, Schneider F, et al. Neuromonitoring and neurocognitive outcome in offpump versus conventional coronary bypass operation. Ann Thorac Surg. 2000;69:1162-1166. 2. Murkin JM, Boyd WD, Ganapathy S, Adams SJ, Peterson RC. Beating heart surgery: why expect less central nervous system morbidity? Ann Thorac Surg. 1999;68:1498-1501. 3. Puskas JD, Wright CE, Ronson RS, Brown WM, Gott JP, Guyton RA. Clinical outcomes and angiographic patency in 125 consecutive off-pump coronary bypass patients. Heart Surg Forum. 1999;2:216-221. 4. Wolf LG, Abu-Omar Y, Choudhary BK, Pigott D, Taggart DP. Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: the effect of an aortic side-biting clamp and two clampless devices. J Thorac Cardiovasc Surg. 2007;133:485-493.

MAQUET Medical Systems USA CLAMPLESS BEATING HEART 5 ACROBAT SUV, and ACROBAT V XPOSE 4 and XPOSE 3 ACROBAT OFF-PUMP SYSTEM XPOSE ACCESS DEVICE Suture with ease. The ACROBAT Off-Pump System provides the strength, visibility, and stability necessary in a variety of surgical situations. Reach target vessels easily. The XPOSE Access Device is designed for apical or nonapical placement, and securely lifts the heart for access to vessels in any location. Excellent stabilization: Malleable feet provide ideal stabilization and superb vessel presentation; tri-slot socket wrist design provides access to difficult vessels in toes-up position, for maximum visibility Strength and flexibility: Low-profile arm is designed for increased strength, and innovative FlexLink technology features interlocking links that enable greater maneuverability Maintain stable hemodynamics: Active suspension technology allows normal cardiac motion Ensure secure contact: Tissue-conforming suction cup uses gentle vacuum to stay in place Reveal hard-to-reach vessels: Low-profile arm makes it easy to see and gain access to any target vessel

MAQUET is a registered trademark of MAQUET GmbH MAQUET, Rastatt Printed in USA 06/13 CAUTION: Federal (US) law restricts this device to sale by or on the order of a physician. Refer to Instructions for Use for current indications, warnings, contraindications, and precautions. MAQUET Medical Systems USA 45 Barbour Pond Drive Wayne, NJ 07470 www.maquetusa.com ca.maquet.com GETINGE GROUP is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and MAQUET. ArjoHuntleigh focuses on patient mobility and wound management solutions. GETINGE provides solutions for infection control within healthcare and contamination prevention within life sciences. MAQUET specializes in solutions, therapies and products for surgical interventions, interventional cardiology and intensive care. MCV00020165 REVA