PINNACLE REVISION CUP SYSTEM

Similar documents
Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Featuring. Technology. Product Rationale

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Optimum implant geometry

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Optimum implant geometry

D E S I G N R A T I O N A L E

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Product Rationale. Where Strength and Modularity Connect

Arcos Modular Femoral Revision System

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Dr. John Masonis Charlotte, NC OrthoCarolina. Dr. James Waddell Toronto, Ontario University of Toronto, St. Michael s Hospital

Bone Preservation Stem

The Leader in Orthopaedic Innovation

G7 ACETABULAR SYSTEM. beautifully. efficient.

Understanding Hip Implant Options

ACETABULAR CUP SURGICAL TECHNIQUE

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

CUTTING GUIDE SYSTEM PRODUCT RATIONALE. Custom-Made Patient Instruments for Total Knee Replacement

OPTIONAL/ADDITIONAL INSTRUMENTS

Optimum implant geometry

TRABECULAR METAL ACETABULAR RESTRICTOR AND AUGMENT. Surgical Technique

PRODUCT RATIONALE & SURGICAL TECHNIQUE

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

Trabecular Metal Acetabular Restrictor and Augment

Trabecular Metal Acetabular Restrictor and Augment

Zimmer Segmental System

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Duraloc CONSTRAINED LINER

AML Hip System. Design Rationale/ Surgical Technique

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

PINNACLE Acetabular Cup System

Trilogy Acetabular System

Trilogy Acetabular System

INSTRUMENTS. Product Rationale

Acetabular Cup System. Clinical Summary

CERAMIC-ON-METAL. References: Cat No: version 2

RECLAIM REVISION HIP SYSTEM

PLR. Proximal Loading Revision Hip System

Reaching new heights. Comprehensive. Efficient. Simple.

Approach Patients with Confidence

HIP CONTINUUM OF CARE. Trauma and Joint Reconstruction Hip Portfolio

MULTIPOLAR BIPOLAR CUP. Surgical Technique

DURALOC A WORLD LEADING CEMENTLESS ACETABULAR CUP SYSTEM

DURALOC. Acetabular Cup System. Surgical Technique

Surgical Technique. Cup System

This publication is not intended for distribution in the USA.

Design Rationale. ECHELON Primary Hip System

RECOVERY. P r o t r u s i o

R3think your options. For US distribution only.

The information contained in this document is intended for healthcare professionals only.

ANATOMIC LOCKED PLATING SYSTEM

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

HP Knee Extraction Instrumentation. Product Overview

JOINT RECONSTRUCTION PORTFOLIO OVERVIEW

Design Rationale/Surgical Technique GRIPTION TF

LAMINA SPREADER SURGICAL TECHNIQUE

The information contained in this document is intended for healthcare professionals only.

INSTRUMENTS. Design Rationale

MicroSeal Total Hip Acetabular System. Like Nothing Else

Approach Patients with CONFIDENCE

Dual Mobility System Surgical technique

Trinity. Advanced Bearing Acetabular System Surgical technique

Manza Cup HA SURGICAL TECHNIQUE.

REFLECTION Constrained Liner Introduction

Trabecular Metal Natural Cup System

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics

Dual Mobility System Evaluation surgical technique

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA.

Versatility in a proven design. Trilogy Acetabular System

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Trilogy Acetabular System

FMP Surgical Technique

HP KNEE EXTRACTION Instrumentation. Product Overview

Longevity Offset and Oblique Liners. Surgical Technique

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

SURGICAL TECHNIQUE IMPROVED WEAR REDUCTION PROVEN FIXATION PRECISE INSTRUMENTATION RELIABILITY

Approach Patients with Confidence

OSSIS is an ISO accredited company.

*smith&nephew CONTOUR

Bone Bangalore

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

SUMMIT and DURALOC. Clinical Summary

OSSIS is an ISO accredited company.

Comprehensive Reverse Shoulder System

TOTAL HIP REPLACEMENT:

HIP SYSTEM SURGICAL TECHNIQUE

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Trabecular Metal Technology The Best Thing Next to Bone

SURGICAL TECHNIQUE FIXATION FIRST ADVANCED MODULARITY MANAGING DISLOCATION WEAR REDUCTION VIP TAPER OPTIMIZING RANGE OF MOTION AND STABILITY

Trabecular Metal Primary Hip Prosthesis

Stability without compromise. Epsilon Durasul Constrained Insert

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Transcription:

PINNACLE REVISION CUP SYSTEM This publication is not intended for distribution in the USA. DESIGN RATIONALE

FLEXIBILITY. PRECISION. CONFIDENCE. DePuy Synthes Joint Reconstruction is proud to offer the PINNACLE Revision Acetabular Cup System to address the need for enhanced stability and biomechanical optimisation while providing immediate and long-term fixation. The PINNACLE Revision Acetabular Cup System was designed to deliver intraoperative flexibility to address the unique challenges of revision acetabular surgery. DESIGNED IN CONSULTATION WITH: William Barrett, MD Seattle WA Daniel Berry, MD Rochester MN Gregory Brick, MD Boston MA John Callaghan, MD Iowa City IA Michael Christie, MD Nashville TN Charles Engh, MD Alexandria VA Thomas Fehring, MD Charlotte NC William Griffin, MD Charlotte NC The PINNACLE Revision Acetabular Cup System consists of the Standard Profile, Deep Profile (DPx) and a Multi-hole shell that feature: Allowance for mechanical fixation in the rim or dome Dome screw holes that can angulate up to 34 degrees designed for intraoperative flexibility and optimal bony purchase The patented VIP taper that accommodates multiple bearing options to address a wide array of patients, activity levels and demand requirements Available sizes ranging from 38 to 80 mm GRIPTION Porous Coating 1 DePuy Synthes Joint Reconstruction PINNACLE Revision Cup System Design Rationale

FIXATION: IMMEDIATE AND LONG-TERM Standard and Deep Profile (DPx) shells feature: A full 180-degree hemisphere for rim friction fit designed to enhance immediate cup stability Deep Profile (DPx) shells with variable, progressive lateralisation that increases with shell size to provide proper graduated proportional medial defect fill Multiple peripheral and dome screw holes for immediate fixation Superiorly clustered dome screw holes to aid bone screw positioning into the best quality host bone Peripheral screw holes for additional fixation while complementing the natural compressive loading of the acetabulum GRIPTION Porous Coating GRIPTION technology is a cementless coating specifically engineered to maintain a clinically advantageous 64% surface volume porosity and an average 220-micron pore structure. 1,2,3 This makes allowance for good tissue growth and vascularisation onto and around an implant. Combined macrotexture and microtexture topographies can provide a favourable mechanical loading environment for bone reconstitution and enable greater cell adhesion and proliferation. 5 GRIPTION coating provides a 1.2 coefficient of friction which is a substantial improvement over plasma spray coating and contemporary tantalum cementless interface. 2,4 This offers potentially improved stability and scratch fit upon implantation. PINNACLE Revision Cup System Design Rationale DePuy Synthes 2

OPTIONS FOR MODULARITY & BIOMECHANICS: INTRAOPERATIVE FLEXIBILITY TO MATCH YOUR PATIENT S NEED Neutral ALTRX ALTRA-LINKED Polyethylene Liners are designed to optimise the range of motion by having a wide face chamfer while keeping the femoral head s centre of rotation concentric with the outer diameter of the shell. +4 Neutral ALTRX ALTRA-LINKED Polyethylene Liners are designed to enhance hip stability, by lateralising the femoral head s centre of rotation by 4 mm. 4 mm of additional lateralisation +4 10 Degree ALTRX ALTRA-LINKED Polyethylene Liners are designed to re-direct the available range of motion and optimise positioning to allow the cup, screw holes and GRIPTION Porous Coating to come into contact with the most optimal surface area of the acetabulum. Apex Peak of Angle Face (Not Lipped) Changes Cup inclination/version by 10 degrees dependent on placement of liner Lipped ALTRX ALTRA-LINKED Polyethylene Liners are designed to provide a high wall along one side of the liner to increase the jump distance in the specific area that the head must travel before dislocation can occur. Apex Lip to be positioned superior/ posterior PINNACLE DPx SHELLS Providing the ability to reproduce the correct centre of rotation The ability to reproduce the centre of rotation is further enhanced with the deep profile cup. The PINNACLE deep profile shells allow the surgeon to address soft tissue laxity through a proportionally variable offset DPx cup. DPx Cup Size (mm) Lateralisation (mm) 54-58 4 60-66 5 68-72 6 Standard Profile Deep Profile 3 DePuy Synthes Joint Reconstruction PINNACLE Revision Cup System Design Rationale

ENHANCED STABILITY LINERS PINNACLE Hip Solutions are designed with a wide range of acetabular cup options, biological and mechanical fixation alternatives and advanced bearing technologies. The PINNACLE ESC Constrained Liner system helps to address hip instability and dislocation through a high range of motion. Features of the ESC Constrained Liner includes: High strength head capture Compatible with bi-polar or modular heads +4 Neutral and +4 10 options GVF polyethylene for enhanced mechanical integrity Simple insertion instrumentation ARD (anti-rotational device) tabs for rotational stability. Titanium locking ring securely holds the ES C liner into the Pinnacle shell to minimise potential disassembly. Chamfered titanium constraining ring provides ease of assembly and increased stability. Ridge to aid in preventing constraining ring slippage. Progressively larger ID and head sizes to help promote increased range of motion. GVF polyethylene. Poly slits and a flex groove for ease of head insertion. PINNACLE Revision Cup System Design Rationale DePuy Synthes 4

ORDERING INFORMATION Acetabular Cup Style Cat No. Outer Acetabular Liner Dome Peripheral Diameter Size Required Screw Hole Screw Hole (mm) (mm) Qty. Qty. ES c Constrained Liner Cat No. Description Cat No. Description GRIPTION Multi-hole II 1217-30-038 38 38 5 0 1217-30-040 40 40 6 0 1217-30-042 42 42 6 0 1217-30-044 44 44 6 0 1217-30-046 46 46 6 0 1217-30-048 48 48 8 0 1217-30-050 50 50 10 0 1217-30-052 52 52 10 0 1217-30-054 54 54 12 0 1217-30-056 56 56 12 0 1217-30-058 58 58 12 0 1217-30-060 60 60 12 0 1217-30-062 62 62 12 0 1217-30-064 64 64 12 0 1217-30-066 66 66 12 0 1217-30-068 68 68 12 0 1217-30-070 70 70 12 0 1217-30-072 72 72 12 0 GRIPTION Standard Profile 1217-16-054 54 48 5 8 1217-16-056 56 50 5 8 1217-16-058 58 52 5 8 1217-16-060 60 54 5 8 1217-16-062 62 56 5 8 1217-16-064 64 58 9 8 1217-16-066 66 60 9 8 1217-16-068 68 62 9 8 1217-16-070 70 64 9 8 1217-16-072 72 66 9 8 1217-16-074 74 70 9 8 1217-16-076 76 72 9 8 1217-16-078 78 74 9 8 1217-16-080 80 76 9 8 GRIPTION Deep Profile DPx 1217-17-054 54 48 5 8 1217-17-056 56 50 5 8 1217-17-058 58 52 5 8 1217-17-060 60 54 5 8 1217-17-062 62 56 5 8 1217-17-064 64 58 9 8 1217-17-066 66 60 9 8 1217-17-068 68 62 9 8 1217-17-070 70 64 9 8 1217-17-072 72 66 9 8 Neutral+4 1218-28-648 28ID 48OD 1218-28-650 28ID 50OD 1218-32-652 32ID 52OD 1218-32-654 32ID 54OD 1218-32-656 32ID 56OD 1218-32-658 32ID 58OD 1218-32-660 32ID 60OD 1218-32-662 32ID 62OD 1218-32-664 32ID 64OD 1218-32-666 32ID 66OD 1218-32-668 32ID 68OD 1218-32-670 32ID 70OD 1218-32-672 32ID 72OD 1218-36-656 36ID 56OD 1218-36-658 36ID 58OD 1218-36-660 36ID 60OD 1218-40-662 40ID 62OD 1218-40-664 40ID 64OD 1218-40-666 40ID 66OD 1218-40-668 40ID 68OD 1218-44-670 44ID 70OD 1218-44-672 44ID 72OD 1218-44-674 44ID 74OD 1218-44-676 44ID 76OD 5.0 mm Peripheral Cortical Bone Screw Cat No. Neutral+4 1257-25-000 25 1257-30-000 30 1257-35-000 35 1257-40-000 40 1257-45-000 45 1257-50-000 50 1257-55-000 55 1257-60-000 60 1257-65-000 65 Length (mm) 10 Degree +4 1218-28-748 28ID 48OD 1218-28-750 28ID 50OD 1218-32-752 32ID 52OD 1218-32-754 32ID 54OD 1218-36-756 36ID 56OD 1218-36-758 36ID 58OD 1218-36-760 36ID 60OD 1218-40-762 40ID 62OD 1218-40-764 40ID 64OD 1218-40-766 40ID 66OD 1218-40-768 40ID 68OD 1218-44-770 44ID 70OD 1218-44-772 44ID 72OD 1218-44-774 44ID 74OD 1218-44-776 44ID 76OD 6.5 mm Cancellous Dome Screw Cat No. Neutral+4 1217-08-500 8 1217-15-500 15 1217-20-500 20 1217-25-500 25 1217-30-500 30 1217-35-500 35 1217-40-500 40 1217-45-500 45 1217-50-500 50 1217-55-500 55 1217-60-500 60 1217-65-500 65 1217-70-500 70 Length (mm) 5 DePuy Synthes Joint Reconstruction PINNACLE Revision Cup System Design Rationale

References 1. Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC. The optimum pore size for the fixation of porous surfaced metal implants by the ingrowth of bone. Clin Orthop 1980;150:263-270. 2. DePuy Internal Test Report: WR070146; 2007. 3. DePuy Internal Test Report: WR070125; 2007. 4. Published literature: No.97-7255-098-00 1003-M20.5ML, Zimmer Inc, 2010 and Zimmer Holdings, Inc. Trabecular Metal Technology. Website accessed Jan 23rd 2014 at URL http://www.zimmer.com/en-us/hcp/hip/our-science/tm-technology.jspx. 5. Karageorgiou V, et al. Porosity of 3D biomaterial scaffolds and osteogenesis. Biomaterials 2005;26:5474-91 DePuy Orthopaedics EMEA is a trading division of DePuy International Limited. Registered Office: St. Anthony s Road, Leeds LS11 8DT, England Registered in England No. 3319712 DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, Indiana 46582 USA Tel: +1 (800) 366 8143 Fax: +1 (574) 267 7196 depuysynthes.com DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0)113 387 7800 Fax: +44 (0)113 387 7890 0086 DePuy International Ltd. and DePuy Orthopaedics, Inc. 2014. All rights reserved. CA#DPEM/ORT/0214/0001 Issued: 04/14