Integra Flowable Wound Matrix

Similar documents
Application Guide for Full-Thickness Wounds

HeliMEND Advanced. Absorbable Collagen Membrane. Instructions for Use

Integra. Tissue Technologies. Limit uncertainty with a leader in collagen technology

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

AXS Catalyst Distal Access Catheter

Integra. PriMatrix Dermal Repair Scaffold PATIENT INFORMATION. Questions? Contact us: Clinician: Phone #: In case of emergency, dial 9-1-1

Integra. TenoGlide Tendon Protector Sheet SURGICAL TECHNIQUE

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

POLYHEAL MICRO - INSTRUCTIONS FOR USE

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

Device Preparation (all steps to be performed per standard interventional technique)

NEPHROCHECK Calibration Verification Kit Package Insert

Integra TenoGlide Tendon Protector Sheet

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

Summary of Package Insert 1 for PuraPly Antimicrobial Wound Matrix

Integra Use of TenoGlide Tendon Protector Sheet to Protect an Extensor Tendon Repair of the Thumb CASE STUDY

Peritoneal Drainage System

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

Smart Solutions for Serious Wounds. An advanced bilayer dermal regeneration matrix FDA approved for the treatment of diabetic foot ulcers.

Instructions for Use. Wright Medical Technology 1023 Cherry Road Memphis, TN USA

Cardiva Catalyst III INSTRUCTIONS FOR USE

Summary of Package Insert 1 for PuraPly Wound Matrix

NovoSorb BTM. A unique synthetic biodegradable wound scaffold. Regenerating tissue. Changing lives.

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

The following languages are included in this packet:

St. Jude Medical 8-Channel Adapter. Clinician's Manual

ASEPT Pleural Drainage System

3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing Description 3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing is used

Pruitt Irrigation Occlusion Catheter. English Instructions for Use. Pruitt Irrigation Occlusion Catheter

NEPHROCHECK Liquid Control Kit Package Insert

WPS Medicare Policy Primer

Instructions for Use Reprocessed Arthroscopic Shavers

ER REBOA Catheter. Instructions for Use

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

Wound & Burn. Reimbursement & Coding Guide

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Integra B: Camino OLM Intracranial Pressure Monitoring Kit SURGICAL TECHNIQUE

P e r i - G u a r d I N S T R U C C I O N E S D E U S O M O D E D E M P L O I... 6 I S T R U Z I O N I P E R L U S O

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

Patient Care Information

LeMaitre Embolectomy Catheter

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:

TruGuard Custom Tongue and Jaw Positioner Instructions for Use

NEPHROCHECK Liquid Control Kit Package Insert

FLEXIC ATH LTD. Peripherally Inserted. Instructions n For Use.

Integra. SafeGuard Mini Carpal Tunnel Release System SURGICAL TECHNIQUE

- Plans Commercial Launch of three dosing options for Excellagen in pre-filled syringes

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

Technique Guide KISSloc Suture System

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

Prolaryn Plus. Injectable Implant INSTRUCTIONS FOR USE

Initial placement 24FR Pull PEG kit REORDER NO:

Advisor FL Circular Mapping Catheter, Sensor Enabled D-AVSE-D10-F20, D-AVSE-DF10-F20, D-AVSE-D10-F15, D-AVSE-DF10-F15. Instructions for Use

DMF Page 63. Description

Integra. Endoscopic Gastrocnemius Release System SURGICAL TECHNIQUE

Single Use Curlew TM Multiple Biopsy Forceps

Peel-Apart Percutaneous Introducer Kits for

Initial placement 20FR Guidewire PEG kit REORDER NO:

The Power of a Hydroconductive Wound Dressing with LevaFiber Technology

Better Post-Op Pain Control Starts Here

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

REVOLVE System Instructional Guide

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

BioFlo PICC. with Endexo and PASV Valve Technology. Clinician Reference Tool

Integra BraIn MaPPIng

Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1

IMPORTANT: PLEASE READ

RealLine Mycoplasma genitalium Str-Format

Salto Talaris Total Ankle Prosthesis

DISTAL RADIUS. Instructions for Use

Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

IMPORTANT: PLEASE READ

Rat Hemoglobin A1c (HbA1c) Kit Instructions

INSTRUCTIONS FOR USE

PRO-DENSE BONE GRAFT SUBSTITUTE

V a s c u - G u a r d

LINEAR 7.5Fr. IAB Catheter

INSTRUCTIONS FOR USE AND CARE

Isn t it worth two bags?

Pruitt-Inahara Carotid Shunt

Balloon in Balloon (BIB )

RAPIDSORB RAPID ReSORBABLe CRANIAL CLAMP

Department Policy. Code: D:PC Entity: Fairview Pharmacy Services. Department: Fairview Home Infusion. Manual: Policy and Procedure Manual

BAYER: KOGENATE FS WITH BIOSET (Recombinant FVIII)

Guide for Use. Advance Plus Touch Free Intermittent Catheter System

Helicobacter pylori Antigen Test

NEGATIVE PRESURE WOUND THERAPY PROGRAM

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

Doc no: IFU/CC Issue date: Rev no: 04 Rev date:

RealLine HIV qualitative Str-Format

Instructions for Use 1

User Bulletin 7500 Fast Precision Plate Holder for MicroAmp Tube Strips

Xcela Hybrid PICC with PASV Valve Technology

Z-MED II BALLOON AORTIC AND PULMONIC VALVULOPLASTY CATHETER. Instructions for Use

Transcription:

Integra Flowable Wound Matrix

Table of Contents How Supplied...2 Storage...2 Product Information Disclosure...2 Symbols Used On Labeling...2 Instructions for Use... 3 Instructions for Use (Continued)... 5 Description... 7 Indications... 7 Contraindications... 7 Precautions... 7 Caution Statement...8 Ordering Information and Phone Numbers... Back Cover

How Supplied Integra Flowable Wound Matrix is supplied sterile, in single use kits containing one syringe with granular collagen, one empty sterile syringe, one luer lock connector, and one flexible injector. Product Code Size Quantity FWD301 3cc 1 Unit/Box Storage Store at room temperature (+10ºc - +30ºc). Avoid excessive heat. Avoid freezing. Product Information Disclosure INTEGRA HAS EXERCISED REASONABLE CARE IN THE SELECTION OF MATERIALS AND THE MANUFACTURE OF THESE PRODUCTS. INTEGRA EXCLUDES ALL WARRANTIES, WHETHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. INTEGRA SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE, DIRECTLY OR INDIRECTLY ARISING FROM USE OF THIS PRODUCT. INTEGRA NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY IN CONNECTION WITH THESE PRODUCTS. INTEGRA INTENDS THAT THIS DEVICE SHOULD BE USED ONLY BY PHYSICIANS SKILLED IN THE USE OF THE DEVICE. Symbols Used On Labeling 2 STERILIZE Do not re-sterilize Do not use if package is damaged Do not re-use Consult instructions for Use LOT Lot number Expiration date +10 C LATEX REF +30 C Temperature limitation Caution: Federal (USA) law restricts this device to sale by or on the order of a physician or practitioner Catalog number This product does not contain and is not manufactured with Dry Natural Rubber or Natural Rubber Latex STERILE STERILE R STERILE EO Sterile Sterilized using irradiation Sterilized using Ethylene Oxide Manufacturer 2.

Instructions for Use 1. Always handle Integra Flowable Wound Matrix using aseptic techniques. Inspect all packaging integrity including protective wrapping, syringes and tip caps. Do not use if packaging is damaged, or tip cap is missing or not fully attached to syringe. Visually inspect the empty syringe. Do not use if empty syringe contains cracks or visible particulate matter. 2. Prepare wound bed using standard methods to ensure wound is free of debris and necrotic tissue. If necessary, surgically debride the wound to ensure the wound edges contain viable tissue. Peel open all three pouches (dry granulated collagen syringe pouch, empty sterile syringe pouch and the luer lock connector accessory pouch). 3. Pour saline into sterile container and draw 3.0ml of saline into the empty syringe. 4. Remove tip cap from the 6ml dry collagen syringe and attach luer lock connector to the collagen syringe. 5. Attach the syringe containing saline to the other end of the luer lock connector. 6. Hold both syringes in your hands securely. 7. Dispense all saline fluid into the dry collagen syringe. 8. Depress plungers back and forth at least 15 times to prepare the Integra Flowable Wound Matrix. 9. Consider the flowable wound matrix mixed when product appearance is consistent and homogeneous and all the product can be moved from one syringe to the other. 3.

Steps 2/3 luer lock connector luer lock connector 6ml collagen 6ml collagen syringe syringe empty syringe flexible injector flexible empty injector syringe Steps 4/5 saline syringe luer lock connector collagen syringe Steps 6/7 4.

Instructions for Use (Continued) 10. Ensure all the mixed material is moved into the 6ml collagen syringe (white plunger). 11. Remove the luer lock connector and the empty syringe while holding the 6ml syringe. 12. Attach flexible injector tip securely to the 6ml syringe. 13. Slowly depress plunger to 3ml to remove air pockets. 14. When dispensing Integra Flowable Wound Matrix, first determine the location of the base of the wound bed utilizing the flexible injector. Upon dispensing product into the wound, avoid pressing the injector tip directly against the base of the wound to ensure the product is not prevented from exiting the flexible injector. 15. After application, use an optimal secondary dressing to maintain matrix adherence and protect the wound area. The optimum dressing is determined by wound location, size, depth and user preference. 16. Change the dressing as needed. Frequency of dressing changes will be dependent upon volume of exudate produced, type of dressing used and the clinician s need to inspect the wound bed for signs of infection or healing. 17. On inspection, if the wound is not completely filled, use an additional dose of the Integra Flowable Wound Matrix to complete the procedure. 5.

Steps 8/9 Steps 10/11 Step 12 flexible injector flexible injector collagen syringe collagen syringe 6.

Description Integra Flowable Wound Matrix is an advanced wound care device comprised of granulated cross-linked bovine tendon collagen and glycosaminoglycan. The granulated collagen-glycosaminoglycan is hydrated with saline and applied in difficult to access wound sites and tunneled wounds. It provides a scaffold for cellular invasion and capillary growth. Integra Flowable Wound Matrix is supplied sterile, in single use kits containing one syringe with granular collagen, one empty sterile syringe, one luer lock connector, and one flexible injector. Indications Integra Flowable Wound Matrix is indicated for the management of wounds including: partial and full-thickness wounds, pressure ulcers, venous ulcers, diabetic ulcers, chronic vascular ulcers, tunneled/undermined wounds, surgical wounds (donor sites/grafts, post-moh s surgery, post-laser surgery, podiatric, wound dehiscence), trauma wounds (abrasions, lacerations, second-degree burns, skin tears) and draining wounds. The device is intended for one-time use. Contraindications This device should not be used in patients with known sensitivity to bovine collagen or chondroitin materials. The device is not indicated for use in third degree burns. Precautions Do not resterilize. Discard all opened and unused portions of Integra Flowable Wound Matrix. Device is sterile if the package is unopened and undamaged. Do not use if the package seal is broken. Discard device if mishandling has caused possible damage or contamination. Integra Flowable Wound Matrix should not be applied until excessive exudate, bleeding, acute swelling and infection are controlled. Debridement or excision must be done thoroughly to remove any remaining necrotic tissue that may cause infection. The following complications are possible with the use of wound management products: infection, chronic inflammation (initial application of wound dressings may be associated with transient, mild, localized inflammation), allergic reaction, excessive redness, pain, or swelling. If any of these conditions occur, the device should be removed. 7.

Caution: Federal law restricts this device to sale by or on the order of a physician or practitioner. For product ordering information, technical questions, or reimbursement issues please call: (U.S.) 877-444-1122 or (Outside U.S.) 609-936-5400 8.

9.

10.

Manufactured by: Integra LifeSciences Corporation 311 Enterprise Drive, Plainsboro, NJ 08536 877-444-1122 USA n 609-936-5400 outside USA 866-800-7742 fax integralife.com Made in the U.S.A. Integra and the Integra logo are registered trademarks of Integra LifeSciences Corporation or its subsidiraies in the United States and/or other countries. 2013 Integra LifeSciences Corporation. All rights reserved.u.s. Patent No: 7,993,679 Additional Patents Pending A4530012000 Rev. B