Spinal Cord Doses in Palliative Lung Radiotherapy Schedules

Similar documents
The Physics of Oesophageal Cancer Radiotherapy

The technique of craniospinal irradiation of paediatric patients in supine position

BLADDER RADIOTHERAPY PLANNING DOCUMENT

Extracranial doses in stereotactic and conventional radiotherapy for pituitary adenomas

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 6, NUMBER 2, SPRING 2005

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

9.5. CONVENTIONAL RADIOTHERAPY TECHNIQUE FOR TREATING THYROID CANCER

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

Disclosure. Paul Medin teaches radiosurgery courses sponsored by BrainLAB Many animals (and humans) were harmed to make this presentation possible!

Sarcoma and Radiation Therapy. Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington

Dose Homogeneity of the Total Body Irradiation in vivo and in vitro confirmed with Thermoluminescent Dosimeter

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

A Dosimetric study of different MLC expansion aperture For the radiotherapy of pancreas cancer

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

A simple technique for craniospinal radiotherapy in the supine position

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Electron therapy Class 3: Clinical procedures

Protocol of Radiotherapy for Breast Cancer

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Comparing Study between Conventional and Conformal Planning Radiotherapy

Assessment of radiation dose to the chest wall and lung of the patients with breast cancer under electron beam therapy

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

Lung cancer remains the most common cause of cancerrelated

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital

A new geometric and mechanical verification device for medical LINACs

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

To investigate the safe levels of radiotherapy administered to patients who have an implanted cardiac device.

Contribution of CT to Quantitative Radiation Therapy Planning

Painful vertebral metastases are a frequent manifestation of malignancies

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

The role of Radiation Oncologist: Hi-tech treatments for liver metastases

Do Advances in Radiotherapy Planning Technology Lead to Improved Palliative Radiotherapy?

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised April 2014

Most patients who present with inoperable, locally

First, how does radiation work?

Left Chest Wall and Supraclavicular Irradiation Using Photon and Electron Energies

Endobronchial High Dose Rate Brachytherapy for Control of NSCLC

Corporate Medical Policy

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

EXPERIMENTAL RESULTS IN PERCENTAGE DEPTH DOSE (PDD) DETERMINATION AT THE EXTENDED DISTANCES *

Intensity Modulated RadioTherapy

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Computerized Treatment Planning in Radiation Therapy of Intact Breast: Influence of Number of CT-Cuts

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

The Four R s. Repair Reoxygenation Repopulation Redistribution. The Radiobiology of Small Fraction Numbers. The Radiobiology of Small Fraction Numbers

A new score predicting the survival of patients with spinal cord compression from myeloma

Aytul OZGEN 1, *, Mutlu HAYRAN 2 and Fatih KAHRAMAN 3 INTRODUCTION

FEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS

Diode calibration for dose determination in total body irradiation

MRC Lung Cancer Working Party - Bolger J.J, Hopwood P, Blehan N.M, Cartmell J, Girling D.J, Machin D, Stephens R.J and Bailey A.J.

Advances in external beam radiotherapy

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

A Smart Setup for Craniospinal Irradiation

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

Breast radiotherapy in women with pectus excavatum (funnel chest): is the lateral decubitus technique an answer? A dosimetric study

Additional Questions for Review 2D & 3D

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Dosimetry of conformal dynamic arc radiotherapy and intensity modulated radiotherapy in unresectable cholangiocarcinoma

Leila E. A. Nichol Royal Surrey County Hospital

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

Defining Target Volumes and Organs at Risk: a common language

Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,

Dose escalation for NSCLC using conformal RT: 3D and IMRT. Hasan Murshed

Disclosure SBRT. SBRT for Spinal Metastases 5/2/2010. No conflicts of interest. Overview

Ashley Pyfferoen, MS, CMD. Gundersen Health Systems La Crosse, WI

GUIDELINES FOR RADIOTHERAPY IN EARLY BREAST CANCER

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Out-of-field organ doses from therapeutic irradiation during childhood: is there an excess risk for second cancer induction?

Does the IMRT technique allow improvement of treatment plans (e.g. lung sparing) for lung cancer patients with small lung volume: a planning study

Cardiovascular disease after radiation therapy

A dosimetric comparison of proton and photon therapy in unresectable cancers of the head of pancreas

Proton Treatment. Keith Brown, Ph.D., CHP. Associate Director, Radiation Safety University of Pennsylvania

Clinical Commissioning Policy Proposition: Proton Beam Therapy for Cancer of the Prostate

A Subset Analysis of Radiation Therapy Oncology Group Trial 97-14

A SIMPLE METHOD OF OBTAINING EQUIVALENT DOSES FOR USE IN HDR BRACHYTHERAPY

Implementation of Hybrid IMRT Breast Planning

Andrew K. Lee, MD, MPH Associate Professor Department tof fradiation Oncology M.D. Anderson Cancer Center

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Radiotherapy techniques in brain tumors (2D, 3D CRT, IMRT) including craniospinal irradiation

Accurate Accurate boost or Simply Accuboost

Transcription:

Journal of the Egyptian Nat. Cancer Inst., Vol. 8, No., June: -, 00 Spinal Cord Doses in Palliative Lung Radiotherapy Schedules HODA AL-BOOZ, FRCR FFRRCSI M.D.* and CAROL PARTON, Ph.D.** The Departments of Clinical Oncology* and Medical Physics**, Bristol Haematology and Oncology Centre, Bristol, United Kingdom. ABSTRACT Aim: We aim to check the safety of the standard palliative radiotherapy techniques by using the Linear quadratic model for a careful estimation of the doses received by the spinal cord, in all standard palliative lung radiotherapy fields and fractionation. Material and Methods: All patients surveyed at this prospective audit were treated with palliative chest radiotherapy for lung cancer over a period from January to June 005 by different clinical oncology specialists within the department. Radiotherapy field criteria were recorded and compared with the recommended limits of the MRC trial protocols for the dose and fractionation prescribed. Doses delivered to structures off the field central axis were estimated using a standard CT scan of the chest. Dose estimates were made using an SLPLAN planning system. As unexpected spinal cord toxicity has been reported after hypofractionated chest radiotherapy, a sagittal view was used to calculate the isodoses along the length of the spinal cord that could lie within the RT field. Equivalent dose estimates are made using the Linear- Quadratic Equivalent Dose formula (LQED). The relative radiation sensitivity of spinal cord for myelopathy (the a/b dose) cord has been estimated as a/b = Gy. Results: 7Gy in fraction and 39Gy in 3 fraction protocols have spinal cord equivalent doses (using the linear-quadratic model) that lie within the conventional safe limits of 50Gy in fractions for the 0% isodose. However when the dosimetry is modelled for a MV 0cm isocentric linnac in 3 dimensions, and altered separations and air space inhomogeneity are considered, the D-Max doses consistently fall above this limit on our 3 model patients. Conclusion: The 7Gy in fraction and 39Gy in 3 fraction protocol would risk spinal cord damage if the radiotherapist was unaware of the potential spinal cord Correspondence: Dr Hoda Al-Booz, Consultant in Clinical Oncology Bristol Haematology and Oncology Centre, hodabooz@doctors,org.uk doses. Alterative doses are suggested below 5.5 Gy/ fractions (7 days apart) would be most acceptable. Key Words: Spinal cord doses Palliative lung radiotherapy Spinal cord tolerance. INTRODUCTION Palliative radiotherapy is used for more than 80% of cases with lung cancer at diagnoses. The publication of successful United Kingdom Medical Research Council (MRC) randomized trials of hypo-fractionated accelerated radiotherapy has changed practice in the UK (Table ) [-]. The MRC studies have concluded that palliation is just as successful with or fractions of radiotherapy as with prolonged courses and toxicity (mainly radiation oesophagitis) is reduced [,]. There was a trend to survival benefit from longer regimens in patients with good performance status and no significant weight loss [3]. Where long fractionation schedules of to 5 fractions were common as palliation; short courses of or fractions now predominate. The MRC trials showed a good safety profile, but now that the doses and fractionation schedules have been incorporated into standard practice, unexpected spinal cord toxicity has been seen [5]. This observational study was planned to discover why this might have happened and to perform a risk assessment for our department. In this study, we have audited practice in a large UK oncology centre, to see if the patient selection criteria and radiotherapy techniques used in the trials have been maintained in routine clinical practice.

Spinal Cord Doses in Palliative Lung Radiotherapy Table (): Randomized trials of hypofractionated radiotherapy for the palliation of non-small cell lung cancer. Reference Doses Patients Palliation Survival Median survival (days) MRC, 99 [] 7Gy/# Vs 30Gy/# 79 77 MRC, 99 [] Gy/# Vs 7Gy/# Poor PS (WHO -) 0 MRC, 99 [3] 7Gy/# Vs 3Gy/ & 39Gy/3# Good PS (WHO ) Quicker with 7Gy/ # Longer with 39Gy/3# (3% @ yrs) 70 Rees et al, 997 [] 7Gy/# Vs.5Gy/5# 80 PATIENTS AND METHODS Patients surveyed at retrospective audit were all patients treated with palliative chest radiotherapy for lung cancer over the period from January to April 003. Radiotherapy field arrangements, field size constraints, doses, dose points for calculation, beam quality, fractionation and treatment times were recorded. These were compared with the recommended limits of the MRC trial protocols for the dose and fractionation prescribed. All patients had received conventional isocentric simulator planning in the supine position. Field borders were defined by simulator wire markers, and recorded to radiographic film or digital image. Simulator field borders represent the 50% isodose. Beam arrangements were all anterior-posterior opposed parallel isocentric pairs, using MV photon linear accelerators at 0 cm source to isocentre distance. The typical penumbra of the treatment machine with this beam arrangement is 7-8mm between the 50% and 90% isodose at the isocentre. In some cases, beam shapes were modified from standard square or rectangle using shadow tray mounted lead blocks or multileaf collimators. Doses were calculated at the field centre, mid-plane dose. No corrections for tissue inhomogeneity, nor correction of air, were performed. Plans that exceeded the dose or field size constraints of the MRC trial protocol appropriate for that dose and fractionation regimen were examined further. Doses delivered to structures off the field central axis were estimated using a standard CT scan of the chest. Dose estimates were made using an SLPLAN planning system. As unexpected spinal cord toxicity has been reported after hypofractionated chest radiotherapy, a sagittal view was used to calculate the isodoses along the length of the spinal cord that could lie within the RT field. Equivalent dose estimates were made using the Linear-Quadratic Equivalent Dose formula (LQED) []. The relative radiation sensitivity of spinal cord for myelopathy (the a/b dose) cord has been estimated as a/b = Gy [7]. RESULTS The audit identified sixty-seven patients treated. Five different radiotherapy doses and schedules were used. All had been used in arms of the MRC fractionation trials. Field sizes exceeding 0 cm were identified in 3 of 7 patients (%), and exceeding 00 cm in 5 patients (0.07%). This is summarized in Table (). Chest wall separations varied in all patients. Three patients were chosen to represent the smallest, medium and large separation to be able to represent the data. Spinal cord equivalent doses were estimated for three patient chest CT images. The saggital images are shown in Fig. () (image made up of 3 saggital scans). The three patients differed in the separation at the field centre of patient A= 9.7 cm. Patient B= 0cm and patient C= 3 cm. For each patient a typical palliative anterior-posterior field of 0 cm size was modelled. For each patient, the dose to the spinal cord was estimated at three points, D max, superior, and inferior field margin. Each estimate was tried on 3 different

Hoda Al-Booz & Carol Parton 3 chest CT images. The linear quadratic equivalent doses in Gy per fraction at α/ß = for each point are shown in Table (3) for a patient with separation 9.7cm, Table () for a patient with separation 0cm and Table (5) for a patient with separation 3cm. The planning system uses pixel-by-pixel correction for tissue density. This means that the effect of an air gap in the lungs and trachea is accounted for in dose estimates. Table (): Radiotherapy field sizes compared with radiotherapy dose and schedule delivered. Regimen Dose in Gy Overall treatment time Number treated Number who received Rt fields exceeding 0cm (%) Number who received Rt fields exceeding 50cm (%) Number who received Rt fields exceeding 00cm (%) (8%) 7 7 3 (9.5%) 7 (30.3%) 3 (3%) 0 5 5-7 8 5 (.5%) 5 (.5%) (%) 3-8 7 (70%) 5 (50%) 39 3 7-9 (0%) (0%) 7 3 (%) 8 (.8%) 5 (7.%) Total Patient Patient Patient 3 Fig. (): Saggital image of chest for patient, and 3. Doses to the spinal cord estimated at three points from an anterior 0cm field: Superior (A), D max (B) and inferior (C). Table (3): Estimated percentage doses, and spinal cord equivalent doses expressed as equivalent dose in Gy fractions at the three points (D max, Superior, and Inferior) for standard patient with 9.7cm separation. Dose in Gy/ Fraction / 7/ 0/5 3/ 39/ 3 Eq. Dose in Gy with Gy/ fractions. α/ß = (for CNS) 3. 5 33 7.9 5 D Max. % 0.5 Gy 59. Gy 3.5 Gy 53 Gy 57.5 Gy Superior point (7%) 39. Gy 57.7 Gy 35.3 Gy 5. Gy 55. Gy Inferior point (5%) 38. Gy 5.7 Gy 3. Gy 50.3 Gy 5. Gy

Spinal Cord Doses in Palliative Lung Radiotherapy Table (): Estimated percentage doses, and spinal cord equivalent doses expressed as equivalent dose in Gy fractions at the three points (D max, Superior, and Inferior) for standard patient with 0cm separation. Dose in Gy/ Fraction / 7/ 0/5 3/ 39/ 3 Eq. Dose in Gy with Gy/ fractions. α/ß = (for CNS) 3.Gy 5 33 7.9 5 D Max 3.7 38Gy 55.9Gy 3.Gy 9.Gy 53.9Gy Superior point (98%) 35.8Gy 5.9Gy 3.3Gy.9Gy 50.9Gy Inferior point (97%) 35.5Gy 5.Gy 3Gy.Gy 50.Gy Table (5): Estimated percentage doses, and spinal cord equivalent doses expressed as equivalent dose in Gy fractions at the three points (D max, Superior, and Inferior) for standard patient 3 with 3 cm separation. Dose in Gy/ Fraction / 7/ 0/5 3/ 39/ 3 Eq. Dose in Gy with Gy/ fractions. α/ß = (for CNS) 3. 5 33 7.9 5 D Max 9.3% 0Gy 59Gy 3Gy 5.3Gy 5.8Gy Superior point (3%) 37.7Gy 55.Gy 3Gy 9.3Gy 53.5Gy Inferior point (%) 37.3Gy 55Gy 33.Gy 8.8Gy 53Gy DISCUSSION The UK MRC trials of altered fractionation radiotherapy to palliate lung cancer symptoms have been successful in changing practice [- ]. Although the aim of treatment is palliation, the median survival of those patients range between and 9 months. For these patients. Late toxicity becomes an important issue. The 7Gy in fraction and 39Gy in 3 fraction schedule has been reported to cause spinal cord toxicity [3]. Our analysis of the schedules used in current practice in a large regional cancer centre suggest that the 7Gy in fraction and 39Gy in 3 fraction protocol would risk spinal cord damage if the radiotherapist was unaware of the potential spinal cord doses. Both schedules have spinal cord equivalent doses (using the linear-quadratic model) that lie within the conventional safe limits of 50Gy in fractions for the 0% isodose [8]. However when the dosimetry is modelled for a MV 0cm isocentric linnac in 3 dimensions, and altered separations and air space inhomogeneity are considered, the D-Max doses consistently fall above this limit on our 3 model patients. The MRC protocol for the 39Gy in 3 fraction schedule advised that posterior spinal cord blocking should be used for the last fractions, to reduce spinal cord dose. No such advice has been given for the 7Gy in fraction protocol. Table (): Randomized trials of palliative radiotherapy regimens. Side effects for the different dose schedules. D: Dysphagia, M: Radiation Myelopathy. Reference Doses Patients Fraction 5 or 3 MRC, 99 7/ Vs 30/ D= 0% M=0.%@ yr.%@ yr D= 0% M=.5%@yr.5%@yr MRC, 99 / Vs 7/ Poor PS (WHO -) D= 3% D= 5% MRC, 99 7/ Vs 39/3 Good PS (WHO ) D= 50% D= 8% Rees et al, 997 7/ Vs 0/5 D= 50% M=0.8% D= 38% M=.3%

Hoda Al-Booz & Carol Parton 5 The risk of high D-max areas within the beams increases for a MV lineac with patient separation. The effect appears greater when the air gaps of lung and trachea are also considered as in our model patients. As a result of this risk assessment, we advise caution in the use of 7 Gy in fractions or 39 Gy in 3 fractions without special consideration. The risks appear greater in larger patient with greater separations, in larger fields or where the separations vary in the saggital plane. Many of our patients required large area palliative radiotherapy fields of greater than 0cm (%), 50cm (.8%) and 00cm (7.%). In these high risk situations, the Gy in fraction, or 0 Gy in 5 fraction schedules would be predicted to be safer treatment options. Palliative regimens are delivered in parallel opposing fields. Most departments would use MV Linear accelerators for such treatment. Fig. () shows the normalized relative-axis dose profiles from parallel-opposed beams for a xcm field at source to skin distance (SSD) of 0cm and for patient diameters of 5 to 30 cm in 5cm increments. It indicates that:..00 0.90 0.80.30.0..00 0.90 0.80 RELATIVE DOSE PROFILES Co-0 Co-0 5 cm 8 Fig. (): Relative central-axis dose profiles as a function of X-ray energy ( 0 Co or,, and 8 MV) and patient thickness (5,0, and 30 cm). Because of the symmetry, only half of the profile is shown []. cm 30 cm 0 cm Co-0 8 Co-0 8 DEPTH FROM MIDLINE Doses at the surfaces are increased with an increase in separation. It is obvious that separations of more than 8 cm should not be treated with parallel-opposed fields if critical organs are present in the high dose region. Doses along the spinal cord are shown in Table () to be above the TD5/5 for the spinal cord (50 Gy) [8] in the commonly used palliative regimens (7 Gy/ fractions and 39 Gy/3 fractions). Although it is our policy to shield the cord posteriorly in the last fraction for the 39 Gy/3 fractions, it is often missed. Also, it appears that restricting to the acceptable field size (< 0cm ) is also not done. As the spinal cord s tolerance dose has been shown to be sensitive to the length of the cord [9-], such doses are not thought to be safe for use in good performance patients who s survival is thought to be longer than the majority of palliative patients. Radiation Myelopathy has been reported following the use of 7 Gy/ fractions and 39 Gy/3 fractions [5]. The annual risk was found to be small, 0.8% (95% CI 0.%-.%) and.3% (95% CI 0.%-.7%) respectively. The cumulative -year risks were % and.5%. This supports that these regimens should be used very cautiously. However, this complication was only seen 8 months after treatment and the median survival of this group of patients is around months. In conclusion, for those prescribed 39 G/3 fractions, 3 Gy in fractions may be more appropriate to be used although doses are still considered to be high. For the 7 Gy/ fractions (7 days apart), doses are also high along the spinal cord, Table (). REFERENCES - Medical Research Council Lung Cancer Working Party. Inoperable non-small cell lung cancer: a Medical Research Council randomized trial of palliative radiotherapy with two fractions or ten fractions. Br J Cancer. 99; 3: 5-70. - Medical Research Council Lung Cancer Working Party. A Medical Research Council (MRC) randomized trial of palliative radiotherapy with two fractions or a single fraction in patients with inoperable non-small cell lung cancer (NSCLC) and poor performance status. Br J Cancer. 99; 5: 93-9. 3- Macbeth FR, Bolger JJ, Hopwood P, Bleehen NM, Cartmell J, Girling DJ, et al. Randomized trial of palliative two fractions versus more intensive 3-

Spinal Cord Doses in Palliative Lung Radiotherapy fraction radiotherapy for patients with inoperable nonsmall cell lung cancer and good performance status. Medical Research council Lung Cancer Working Party. Clin Oncol. 99; 8:7-75. - Rees GJG, Devrell CE, Barley VL, Newman HFV. Palliative radiotherapy: two versus five fractions. Clin Oncol. 997; 9: 90-95. 5- Macbeth FR, Wheldon TE, Girling DJ, Stephens RJ, Machin D, Bleehen NM, et al, Medical Research Council Lung Cancer Working Party, Radiation Myelopathy: estimates of risk in 8 patients in three randomized trials of palliative radiotherapy for nonsmall cell lung cancer. Clin Oncol. 99; 8: 7-8 - Taylor, J.M.G., H.R. Withers. Estimating the parameter in the -component model for cell survival from experimental quantal response data. Radiat. Res. 985; : 358-3. 7- Barton M. Tables of equivalent dose in Gy fractions: a simple application of the linear quadratic formula. Int J Radiat Oncol. Biol. Phys. 995 Jan5; 3 (): 37-8. 8- Emami B, Lyman J, Brown A, Coia L, Goitein M, Munzenrider JE, et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radiation Oncol Biol Phys. 99; : 9-. 9- Withers H.R., Taylor J.M.G., Maciejewski B. Treatment volume and tissue tolerance. Int. J. Radiat. Oncol. Biol. Phy. 988; : 75-759. - Withers, H.R., Taylor J.M.G. Volume effect in spinal cord. Letter to the Editor. Br. J. Radiol. 988; : 973. - Perez CA, Brady LW, eds. Principles and Parctice of radiation oncology, 3 rd ed. Philadelphia: Lippincott- Raven. 998; 8-30.