MADIT-RIT: Simple programming change averts most inappropriate ICD therapy

Similar documents
MADIT Studies: CRT in the Non-LBBB Patient and Other Findings. Arthur J. Moss, MD

Shock Reduction Strategies Michael Geist E. Wolfson MC

Comparison of clinical trials evaluating cardiac resynchronization therapy in mild to moderate heart failure

Endpoints When Treating VT/VF in Patients with ICDs Programming Wojciech Zareba, MD, PhD

Response of Right Ventricular Size to Treatment with Cardiac Resynchronization Therapy and the Risk of Ventricular Tachyarrhythmias in MADIT-CRT

Recurrent Implantable Defibrillator Discharges (ICD) Discharges ICD Storm

Tech Corner. ATP in the Fast VT zone

HF and CRT: CRT-P versus CRT-D

Arthur J. Moss, MD Professor of Medicine/Cardiology University of Rochester Medical Center Rochester, NY. DISCLOSURE INFORMATION Arthur J.

La gestione di un paziente con ICD: come evitare gli shock inappropriati e prolungare la sopravvivenza del paziente. Maurizio Gasparini

Preventing Sudden Death Current & Future Role of ICD Therapy

Dialysis-Dependent Cardiomyopathy Patients Demonstrate Poor Survival Despite Reverse Remodeling With Cardiac Resynchronization Therapy

Εκθορηίζεις απινιδωηή και θνηηόηηηα: μέθοδοι μείωζης ηων θεραπειών απινίδωζης

Implantable Cardioverter Defibrillator Therapy in MADIT II Patients with Signs and Symptoms of Heart Failure

CRT-P or CRT-D From North Alberta to Nairobi

Device Interrogation- Pacemakers, ICD and Loop Recorders. Dulce Obias-Manno, RN, MHSA, CCDS,CEPS, FHRS Device Clinic Coordinator, MHVI

Tachyarrhythmia Suspicion and Detection

Subcutaneous Implantable Cardioverter Defibrillator (S-ICD)

Primary prevention of SCD with the ICD in Nonischemic Cardiomyopathy

Who does not need a primary preventive ICD?

The Role of ICD Therapy in Cardiac Resynchronization

Reducing Inappropriate and Appropriate Therapy in Primary Preven7on Pa7ents

Reducing unnecessary and inappropriate therapy in secondary prevention patients

A BS TR AC T. n engl j med 367;24 nejm.org december 13,

Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patients

THE ROLE OF ICD THERAPY FOR PRIMARY PREVENTION Leonard Ganz, M.D. Pittsburgh, PA

ICD THERAPIES: are they harmful or just high risk markers?

Cardiac Resynchronization ICD Therapy: What is New?

PARAD/PARAD+ : P and R Based Arrhythmia Detection

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

State of the art of ICD programming: Lessons learned and future directions

Continuous ECG telemonitoring with implantable devices: the expected clinical benefits

Defibrillation testing should be routinely performed at the time of implantable cardioverter-defibrillator implantation Contra

Mahmoud Suleiman MD. On behalf of the Israeli ICD Registry Scientific Committee. Jan 11, National ICD Registry

Cardiac Devices CRT,ICD: Who is and is not a Candidate? Who Decides

Strategic Programming of Detection and Therapy Parameters in Implantable Cardioverter-Defibrillators Reduces Shocks in Primary Prevention Patients

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

Introduction. CLINICAL RESEARCH Clinical Trial Design. Mohammad Saeed 1 *, Mehdi Razavi 1, Curtis G. Neason 2, and Simona Petrutiu 2. Aims.

Large RCT s of CRT 2002 to present

Diagnostic capabilities of the implantable therapeutic systems

HRS Abstract from the ALTITUDE Clinical Science Program as presented at Heart Rhythm Society Conference, May 2011; San Francisco, CA USA

How is it possible to preview acute HF?

Risk Stratification of Sudden Cardiac Death

Clinical course and prognostic relevance of antitachycardia pacing-terminated ventricular tachyarrhythmias in implantable cardioverterdefibrillator

Selecting the Best ICD for your Patient-SICD v. TV. Martin C. Burke DO, FACOI CorVita Science Foundation & Academic Medical Center, Amsterdam

Device Update Implantable Cardioverter Defibrillator (ICD) 박상원

Summary, conclusions and future perspectives

Primary prevention ICD recipients: the need for defibrillator back-up after an event-free first battery service-life

SPORTS AND EXERCISE ADVICE IN PATIENTS WITH ICD AND PPM

Journal of Arrhythmia

Critical Analysis of Dual-Chamber Implantable Cardioverter-Defibrillator Arrhythmia Detection

A Comparison of Empiric to Physician-Tailored Programming of Implantable Cardioverter-Defibrillators

Shocks burden and increased mortality in implantable cardioverter-defibrillator patients

OHTAC Recommendation: Internet- Based Device-Assisted Remote Monitoring of Cardiovascular Implantable Electronic Devices

ESC Guidelines. ESC Guidelines Update For internal training purpose. European Heart Journal, doi: /eurheart/ehn309

Antiarrhythmic Drugs and Ablation in Patients with ICD and Shocks

CRT-D or CRT-P: HOW TO CHOOSE THE RIGHT PATIENT?

Impact of Shocks on Mortality in Patients with Ischemic or Dilated Cardiomyopathy and Defibrillators Implanted for Primary Prevention

What You Should Know About Subcutaneous and Transvenous ICD

Biventricular Pacemakers (Cardiac Resynchronization Therapy) for the Treatment of Heart Failure

Devices and Other Non- Pharmacologic Therapy in CHF. Angel R. Leon, MD FACC Division of Cardiology Emory University School of Medicine

ESC Stockholm Arrhythmias & pacing

Cardiac resynchronization therapy for mild-to-moderate heart failure

Chapter 2. Long-term follow-up of primary and secondary prevention implantable cardioverter defibrillator patients

Arrhythmia/Electrophysiology

Device management and generator changes at end of life: what do we want to avoid? Dr Stephen Pettit, Consultant Cardiologist

The Therapeutic Role of the Implantable Cardioverter Defibrillator in Arrhythmogenic Right Ventricular Dysplasia

Implantable cardioverter-defibrillators and cardiac resynchronization therapy

CONTAK RENEWAL CLINICAL SUMMARY

NEED A DEFIBRILLATOR? NOW YOU HAVE OPTIONS.

Clinical endpoints for VT/VF suppression in Patients with ICDs: Living longer and feeling better

Effectiveness of Implantable Cardioverter-Defibrillator Therapy for Heart Failure Patients according to Ischemic or Non-Ischemic Etiology in Korea

Live Better Electrically

INNOVATIONS IN DEVICE THERAPY:

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Sudden Cardiac Death

/$ -see front matter 2011 Heart Rhythm Society. All rights reserved. doi: /j.hrthm

SVT Discriminators. Definition of SVT Discrimination. Identify which patient populations might benefit from these features

LONGITUDINAL SURVEILLANCE REGISTRY OF ACUITY SPIRAL LEAD

Cardiac resynchronisation therapy (biventricular pacing) for the treatment of heart failure

CONTAK RENEWAL 3 AVT CLINICAL SUMMARY

BENEFIT OF CRT IN MILDLY SYMPTOMATIC HEART FAILURE RECENT DATA FROM MADIT-CRT AND RAFT

Evaluation of Sum Absolute QRST Integral as a Clinical Marker for Ventricular Arrhythmias. Markus Kowalsky Group 11

The patient with electric storm

Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure

Prognostic Importance of Defibrillator Shock

Device detected VT: How much VT is significant and is VT ablation the answer?

Arrhythmia/Electrophysiology

Sudden death as co-morbidity in patients following vascular intervention

Protocol. This trial protocol has been provided by the authors to give readers additional information about their work.

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

A Closer Look Product Education at a glance

ICD: Basics, Programming and Trouble-shooting

NHS. Implantable cardioverter defibrillators (ICDs) for arrhythmias. National Institute for Health and Clinical Excellence. Issue date: January 2006

Device Based Therapy for the Failing Heart: ICD and Cardiac Resynchronization Rx

Cover Page. The handle holds various files of this Leiden University dissertation.

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART II

SUBCUTANEOUS ICD ITS JOURNEY FROM PROOF OF CONCEPT TO CURRENT EVOLUTION

Current guidelines for device-based therapy of cardiac

Where Does the Wearable Cardioverter Defibrillator (WCD) Fit In?

Transcription:

Print MADIT-RIT: Simple programming change averts most inappropriate ICD therapy NOV 6, 2012 Steve Stiles Los Angeles, CA - A large randomized trial has identified specific programming criteria for implantable cardioverter defibrillator (ICD) devices that, compared with conventional programming, cut the risk of inappropriately delivered therapy by almost 80% [1]. The alternate programming also led to a significant drop in mortality in the patients with primary-prevention ICDs by more than one-half over a follow-up averaging 1.4 years. The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) supports the use of a fairly easy adjustment to standard ICD programming that could largely alleviate a problem that has long been a weakness of the therapy. Inappropriate treatment of non-life-threatening arrhythmias adds to the distress of patients with the devices and may worsen outcomes. The study is published online today in the New England Journal of Medicine, with lead author Dr Arthur J Moss (University of Rochester, NY), to coincide with his presentation of the trial here at the American Heart Association 2012 Scientific Sessions. ICD survival value underestimated "The results were striking and a little unexpected," Moss told heartwire. "They first of all showed a reduction in inappropriate therapy due mostly to antitachycardia pacing [ATP], but in addition there was the significant reduction in mortality." Ordinarily in such patients, ICDs might be counted on to cut the rate of death by about 30%, according to Moss. But with the more successful of the two alternative programming strategies in MADIT-RIT which initiated device therapy, usually ATP, only with a heart rate of >200 bpm "it reduced mortality an additional 55%."

This is a large randomized trial that supports absolutely all the studies that have come before it, with a large and clearly significant outcome. So I think this is huge. Allowing patients to tolerate the arrhythmias until the heart rate reached that threshold did not increase the prevalence of fainting spells, contrary to some concerns. But it did seem to help ICDs more frequently avoid delivering therapy to relatively benign supraventricular arrhythmias and some nonsustained ventricular arrhythmias. With conventional programming, ATP tends to kick in at about 170 bpm, Moss observed, but such therapy often isn't needed, because many rhythms in the range of 170 to 200 bpm tend to stop spontaneously without ill effects. And avoiding ATP is a good idea; among other reasons, it's well-known to occasionally induce ventricular fibrillation. Dr Bruce L Wilkoff Dr Bruce L Wilkoff (Cleveland Clinic, OH) observed for heartwire that MADIT- RIT builds on a rich history of more limited studies like PREPARE, EMPIRIC, and two PAINFREE trials, as well as other analyses that explored programming strategies for lowering rates of delivered ICD therapy. "It would have been very surprising to me if this had not been a positive study, but what we didn't have before was a large, randomized clinical trial," Wilkoff said. "This is a large randomized trial that supports absolutely all the studies that have come before it, with a large and clearly significant outcome. So I think this is huge." MADIT-RIT, he said, "implies that we've underestimated the survival benefit and overestimated the morbidity of defibrillators." In his editorial accompanying the trial's publication [2], Wilkoff writes that MADIT-RIT shows "the value of ICD therapy is greatly influenced and in many ways determined by the programming choices made by the physician. A patient's unnecessary exposure to painful shocks and his or her very survival may depend on these choices. Choose wisely!"

"High-rate" vs "delayed" vs conventional therapy Dr Arthur J Moss The trial randomized 1500 patients at 98 centers, predominantly in the US but also Canada, Europe, Israel, and Japan. They had either ischemic or nonischemic disease with an indication for a primary-prevention ICD or cardiacresynchronization therapy device with an ICD (CRT-D), which had to have been their first such device. Patients with atrial fibrillation were excluded. They were assigned to one of three ICD-programming groups with the primary goal of finding their rate of a first occurrence of inappropriate ATP or shocks: a "high-rate-therapy" group with a 2.5-second delay before starting ATP at a heart rate of >200 bpm; a "delayed-therapy" group with longer delays at different prespecified heart-rate thresholds; and conventional programming with delays of 2.5 seconds for heart rates of 170 to 199 bpm and of 1.0 second for rates >200 bpm. Hazard ratio (HR) for a first occurrence of inappropriate therapy and for death in the high-rate a and delayed-therapy b groups vs conventional programming c in MADIT-RIT End point First occurrence of inappropriate therapy High-rate vs conventional programming, HR (95% CI), p Delayed vs conventional programming, HR (95% CI), p 0.21 (0.13-0.34), <0.001 0.24 (0.15-0.40), <0.001 Death 0.45 (0.24-0.85), 0.01 0.56 (0.30-1.02), 0.06 a. 2.5-second delay before starting ATP at a heart rate of >200 bpm b. Rhythm-detection algorithm and a 60-second delay at heart rates of 170 to 199 bpm, a 12-second delay at a rate of 200 to 249 bpm, and a 2.5-second delay at >250 bpm c. Delays of 2.5 seconds for heart rates of 170 to 199 bpm and of 1.0 second for rates >200 bpm

Moss and his colleagues did complete a preliminary analysis of treatment effects by prespecified subgroups according to age, sex, heart-failure etiology and NYHA class, presence of left bundle branch block, QRS duration, and LVEF. "In every single one of them, the hazard ratio stayed below one," Moss said. "There was absolute consistency." Wilkoff said MADIT-RIT "also tells us a lot about the nature of defibrillator therapy." Generic medications by and large achieve the same therapeutic effects as their proprietary matches, he notes, and ICDs all deliver shocks determined by the same physics regardless of which company makes them. "But, a defibrillator is a different device the moment I program it, and this study shows you how different it is." MADIT-RIT was funded by Boston Scientific, from which Moss discloses receiving a research grant; disclosures for his coauthors are found at www.nejm.org. Wilkoff discloses board membership with Spectranetics, Medtronic, and St Jude Medical. Sources 1. Moss AJ, Schuger C, Beck CA, et al. Reduction in inappropriate therapy and mortality through ICD programming. N Engl J Med 2012; DOI: 10.1056/NEJMoa1211107. Available at: http://www.nejm.org. 2. Wilkoff BL. Improved programming of ICDs. N Engl J Med 2012; Available at: http://www.nejm.org. Related links ALTITUDE: "Inappropriate" ICD shocks off the hook for mortality increase [Arrhythmia/EP > Arrhythmia/EP; May 06, 2011] Inappropriate ICD shocks up mortality in analysis, again [Arrhythmia/EP > Arrhythmia/EP; Jan 25, 2011] Successful primary-prevention ICD shocks present mortality paradox [Arrhythmia/EP > Arrhythmia/EP; Dec 10, 2010] More strategic defibrillator programming can reduce shocks [Arrhythmia/EP > Arrhythmia/EP; May 13, 2010] ICD effectiveness: Do patients appreciate their limits? The debate continues [Arrhythmia/EP > Arrhythmia/EP; Sep 22, 2008] Aggressive programming to treat arrhythmia with pacing before shocks safely reduces ICD morbidity [heartwire > News; May 11, 2007] Better programming, concomitant drugs can reduce ICD shocks [heartwire > News; Dec 20, 2006]

Standardized ICD programming is as effective as customized physiciantailored management [heartwire > News; May 10, 2005] ICD treatment of VT/VF followed by an increased all-cause mortality risk in MADIT-2 subanalysis [HeartWire > Heart failure; Dec 10, 2004] Antitachycardia pacing safe and effective in fast VT [heartwire > News; Oct 19, 2004] Antitachycardia pacing to treat fast VT results in 70% fewer shocks compared with normal ICD [HeartWire > News; May 20, 2003] Copyright 1999-2012 theheart.org by WebMD. All rights reserved. Privacy policy info@theheart.org