Low Retention Tips Optimum Flow for Optimum Recovery

Similar documents
Low Retention Tips Optimum Flow for Optimum Recovery

Low Retention Tips Optimum Flow for Optimum Recovery

Thermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details

Thermo Scientific ART Pipette Tips. superior tips. for any application, any pipette

Thermo Scientific ART Pipette Tips

Midi Plant Genomic DNA Purification Kit

The new generation of TipOne Pipette Tips

Solutions for Liquid Handling

R ESEARCH G RADE LIQUID HANDLING PRODUCTS 2013/2014 PIPETTE CATALOG. Sorenson BioScience, Inc.

micropipettes clinical laboratory single channel fully autoclavable

Qualitix reliable consumables by excellence

Pipet Tips. Overview Tip Refill System Microvolume Tips Universal Fit Aerosol Barrier Tips Multi-Barrier Tips...

Eppendorf Research plus. Raise the limits NEW! Order no. A /GB4/10T/1109/FEEL/PRINT64 Printed in Germany

PRODUCT: RNAzol BD for Blood May 2014 Catalog No: RB 192 Storage: Store at room temperature

Raise the limits. Eppendorf Research plus

NEW: with integrated step counter. Count on it! The new Eppendorf Multipette M4: simple, stress-free and ergonomic

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.

Single Cell Quantitative Polymer Chain Reaction (sc-qpcr)

Wolf Laboratories Limited

I. Introduction. II. Characteristics

Thermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

FOR LABORATORY USE ONLY

Color-coded display window for easy tip selection. Precise, 4-digit volume display with integrated zoom function for optimal readability

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

Storage: Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Positive Control must be stored at -20 ⁰C and can last up to 60 days.

Standard Operation Procedure (SOP) for Biobanking Sampling Procedure Manual Use

Mouse C-peptide EIA. Cat. No. YII-YK013-EX FOR LABORATORY USE ONLY

HbA1c (Human) ELISA Kit

Mouse C-peptide ELISA

INSTRUCTION MANUAL. RNA Clean & Concentrator -5 Catalog Nos. R1015 & R1016. Highlights. Contents

Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

YK052 Mouse Leptin ELISA

Mouse C-peptide ELISA

Bovine Insulin ELISA

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

Porcine/Canine Insulin ELISA

Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

Mouse Ultrasensitive Insulin ELISA

XTRAKT FFPE Kit / Manual

ratmdr1b PE ATPase Kit Assay Protocol jav CAT. NO. SBPE06

Rat Proinsulin ELISA

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

ab MitoTox Complex I OXPHOS Activity Microplate Assay

GSI Canine IL-5 ELISA Kit-2 Plates DataSheet

ABIOpure TM Viral (version 2.0)

AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT

Chymotrypsin ELISA Kit

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Microsart Calibration Reagent

GLP-2 (Rat) ELISA. For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma

Rat C-Peptide EIA. Cat. No. YII-YK010-EX FOR LABORATORY USE ONLY

ExiPrep TM Viral DNA/ RNA Kit

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Amantadine ELISA Test Kit

LDL (Human) ELISA Kit

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

Manual (Second edition)

Thyroid Stimulating Hormone (S-TSH) Thyroid Stimulating

Procine sphingomyelin ELISA Kit

For Research Use Only Ver

GLP-2 ELISA. For the quantitative determination of GLP-2 in human serum and plasma samples.

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

C-Peptide I and II (Rat) ELISA

Human Thyroid Stimulating Hormone CLIA kit

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

Insulin (Porcine/Canine) ELISA

Minute TM Plasma Membrane Protein Isolation and Cell Fractionation Kit User Manual (v5)

Fish follicle-stimulating hormone, FSH ELISA Kit

Insulin ELISA. For the quantitative determination of insulin in serum and plasma

For Research Use Only Ver

For Research Use Only Ver

Human Obestatin ELISA

Vitamin A-E Serum HPLC Analysis Kit

See external label 2 C-8 C Σ=96 tests Cat # 3122Z MICROWELL ELISA THYROID STIMULATING HORMONE (TSH) ENZYME IMMUNOASSAY TEST KIT TSH.

Thermo Scientific ClipTip Pipetting Systems. Sealed in security Feel the difference

Pinpoint Slide RNA Isolation System II Catalog No. R1007

MasterPure RNA Purification Kit

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Ⅰ.Introduction. Ⅱ.Characteristics

Human Free Thyroxine (ft4) CLIA Kit

Adhese Universal The universal adhesive

Urine Exosome RNA Isolation Kit Product #47200

Improve Protein Analysis with the New, Mass Spectrometry- Compatible ProteasMAX Surfactant

Toxoplasma gondii IgM ELISA Kit

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research.

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Nori Rabbit IL-2 ELISA Kit DataSheet

CyBio Felix Your Automated Application Starts Here

IgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

Manual innuprep DNA/RNA Virus PLUS Kit - KFFLX

hcg (Human) CLIA Kit Catalog Number KA assays Version: 01 Intended for research use only

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

InnoZyme Myeloperoxidase Activity Kit Cat. No. CBA024

Transcription:

Low Retention Tips Optimum Flow for Optimum Recovery

Maximize Your Sample Recovery Save Valuable Reagents Pipetting detergent containing liquids can be problematic when using standard pipette tips. Some residue of liquid often remains in the tip due to differences in surface energies between the plastic pipette tip and the sample. This sometimes difficult to visualize residue causes imprecision in pipetting, and loss of valuable samples or reagents. Tip with regular liquid retention To overcome this issue we have utilized an advanced technology to create an extremely even and durable hydrophobic surface on our Low Retention Tips. This feature helps you to maximize the sample recovery, when handling detergent containing or other liquids with low surface tension. Better reproducibility in pipetting is especially beneficial in sensitive molecular biology applications, where reagents often contain detergents, for example in: PCR, real-time PCR Cloning, sequencing and other DNA & RNA techniques SDS-PAGE and other protein analysis methods Protein purification techniques Sartorius Low Retention Tip SafetySpace TM Filter Tips with Low Retention Feature Doubled Security for Sample Recovery! The extremely hydrophobic tip surface combined with the safety air gap between the sample and the filter improves the sample recovery in two ways: through better liquid flow, and by reducing the risk of the sample penetrating the filter. Thus these tips are ideal for sensitive molecular biology applications, where reagents contain detergents. prevention of cross-contamination is vital. multi-dispensing with excess liquid volume is used.

Sartorius Low Retention Tips Clearly Reduce Sample Loss Comparison of Residual Liquid Amounts Residual liquid (µl) 5,00 Test Setup Low retention tips from four manufacturers were compared against Sartorius standard and Low Retention Tips, when pipetting 120 µl of colored PCR buffer (cont. detergents and density agent) with Sartorius mline mechanical pipette. The remaining liquid amount in the tip after dispensing was measured with a gravimetric method. The test was repeated with 10 tips of each supplier and tip type. The error bars show the standard deviations. Results Sartorius Low Retention Tips retained the least amount of residue, whereas some of the other suppliers low retention tips performed similarily to Sartorius standard tips. The use of Sartorius Low Retention Tips resulted in best pipetting reproducibility, supporting the benefits of these tips e.g. in PCR setup. 4,50 4,00 3,50 3,00 2,50 2,00 1,50 1,00 0,50 0,00 Sartorius standard tip Sartorius Low Ret. Filter tip (120 µl) Sartorius Low Supplier A Low Sartorius Low Retention Tips Have High Chemical Resistance Supplier B Low Ret. Filter tip Supplier C Low (300 µl) Supplier D Low Comparison of Chemical Resistances Test Setup Low retention tips from three manufacturers were compared with Sartorius standard and Low Retention Tips. The test was performed by pipetting 1000 µl of each solvent 20 times with every test tip with full volume using Sartorius Picus electronic pipette. After rinsing three times with distilled water, the effects of this treatment to the performance of the low retention tips were analyzed with an absorbance-based test method using colored liquid as a test solution. The test was repeated with six tips of every manufacturer and tip type. Residual liquid [µl] 10 9 8 7 6 5 4 3 2 1 0 No treatment Results When comparing liquid retention after chemical treatment with non-treated tips, it was seen that the performance of Sartorius Isopropanol Acetonitrile DMF Sartorius standard tip Sartorius Low Supplier X Low Supplier Y Low Supplier Z Low Low Retention Tips was not compromised, whereas the other tips tested lost some of their functionality after the chemical treatment.

Improve Consistency Secure Reliable Results Optimum Liquid Flow Optimum recovery Save samples & reagents High Reproducibility Gain more precise and consistent pipetting results Achieve better reliability High Chemical Resistence No leachables Secure sample and result integrity

Ordering Information Low Retention Optifit Tips Fisher Low Sci. Retention Sartorius Optifit Tips RNase, DNase, Pre- Cat. VWR No. Cat. Sartorius No Description Volume Length Packaging RNase, endotoxin DNase, RNase, free DNase, Pre- sterilised Pre- Quantity 14-557-684 Order Cat. No. Code. LH-L790010 Cat. NoDescription Optifit Description Tip Low Retention Volume 0.1-10 Volume µl Length31.5 mm Length Packaging Single Packaging Tray endotoxin endotoxin free sterilised free sterilised Quantity 10 + Quantity 96 14-557-685 LH-L790010 10033-048 LH-L790012 LH-L790010 Optifit Tip Low Optifit Retention Tip Low Retention 0.1-10 µl 0.1-10 31.5 mm µl 31.5 Single mmtray Single Tray 10 + 96 10 + 96 Optifit Tip Low Retention 0.1-10 µl 31.5 mm Refill Tower 10 + 96 14-557-686 LH-L790012 10033-050 LH-L790200 LH-L790012 Optifit Tip Low Optifit Retention Tip Low Retention 0.1-10 µl 0.1-10 31.5 mm µl 31.5 Refill mm TowerRefill Tower 10 + 96 10 + 96 Optifit Tip Low Retention 0.5-200 µl 51 mm Single Tray 10 + 96 14-557-687 LH-L790200 10033-052 LH-L790202 LH-L790200 Optifit Tip Low Optifit Retention Tip Low Retention 0.5-200 µl 0.5-200 51 mmµl 51 Single mm Tray Single Tray 10 + 96 10 + 96 Optifit Tip Low Retention 0.5-200 µl 51 mm Refill Tower 10 + 96 14-557-688 LH-L790202 10033-056 LH-L790350 LH-L790202 Optifit Tip Low Optifit Retention Tip Low Retention 0.5-200 µl 0.5-200 51 mmµl 51 Refill mmtowerrefill Tower 10 + 96 10 + 96 Optifit Tip Low Retention 5-350 µl 54 mm Single Tray 10 + 96 14-557-689 LH-L790350 10033-058 LH-L790352 LH-L790350 Optifit Tip Low Optifit Retention Tip Low Retention 5-350 µl 5-350 54 mm µl 54 Single mm Tray Single Tray 10 + 96 10 + 96 Optifit Tip Low Retention 5-350 µl 54 mm Refill Tower 10 + 96 14-557-690 LH-L790352 10033-060 LH-L791000 LH-L790352 Optifit Tip Low Optifit Retention Tip Low Retention 5-350 µl 5-350 54 mm µl 54 Refill mmtowerrefill Tower 10 + 96 10 + 96 Optifit Tip Low Retention 10-1000 µl 71.5 mm Single Tray 10 + 96 14-557-691 LH-L791000 10033-062 LH-L791200 LH-L791000 Optifit Tip Low Optifit Retention Tip Low Retention 10-1000 µl 10-1000 71.5 mmµl 71.5 Single mmtray Single Tray 10 + 96 10 + 96 Optifit Tip Low Retention 50-1200 µl 71.5 mm Single Tray 10 + 96 14-557-692 LH-L791200 10033-064 LH-L791210 LH-L791200 Optifit Tip Low Optifit Retention Tip Low Retention 50-1200 µl 50-1200 71.5 mmµl 71.5 Single mmtray Single Tray 10 + 96 10 + 96 Optifit Tip Low Retention, Ext. 50-1200 µl 90 mm Single Tray 10 + 96 LH-L791210 10033-066 LH-L791210 Optifit Tip Low Optifit Retention, Tip Low Ext. Retention, 50-1200 Ext. µl 50-1200 90 mmµl 90 Single mm Tray Single Tray 10 + 96 10 + 96 Low Retention SafetySpace TM Filter Tips Fisher Low Sci. Retention Sartorius SafetySpace TM Filter Tips RNase, DNase, Pre- Cat. VWR No. Cat. Sartorius No Description Volume Length Packaging RNase, endotoxin DNase, RNase, free DNase, Pre- sterilised Pre- Quantity 14-557-693 Order Cat. No. Code. LH-LF790011 Cat. NoDescription SafetySpaceTM DescriptionFilter Tip Low Volume Ret. 0.1-10 Volume Length µl 32 mm Packaging LengthSingle Packaging Tray endotoxin endotoxin free sterilised free sterilised Quantity 10 + Quantity 96 14-557-694 LH-LF790011 10033-068 LH-LF790021 LH-LF790011 SafetySpaceTM SafetySpaceTM Filter Tip Low Filter Ret. Tip 0.1-10 Low Ret. µl 0.1-10 32 mmµl Single 32 mmtray Single Tray 10 + 96 10 + 96 SafetySpaceTM Filter Tip Low Ret. 0.5-20 µl 51 mm Single Tray 10 + 96 14-557-695 LH-LF790021 10033-070 LH-LF790101 LH-LF790021 SafetySpaceTM SafetySpaceTM Filter Tip Low Filter Ret. Tip 0.5-20 Low Ret. µl 0.5-20 51 mmµl Single 51 mmtray Single Tray 10 + 96 10 + 96 SafetySpaceTM Filter Tip Low Ret. 2-120 µl 51 mm Single Tray 10 + 96 14-557-696 LH-LF790101 10033-072 LH-LF790201 LH-LF790101 SafetySpaceTM SafetySpaceTM Filter Tip Low Filter Ret. Tip 2-120 Low µl Ret. 2-120 51 mmµl Single 51 mmtray Single Tray 10 + 96 10 + 96 SafetySpaceTM Filter Tip Low Ret. 5-200 µl 52.5 mm Single Tray 10 + 96 14-557-697 LH-LF790201 10033-074 LH-LF790301 LH-LF790201 SafetySpaceTM SafetySpaceTM Filter Tip Low Filter Ret. Tip 5-200 Low µl Ret. 5-200 52.5 mm µl Single 52.5 mm Tray Single Tray 10 + 96 10 + 96 SafetySpaceTM Filter Tip Low Ret. 5-300 µl 52.5 mm Single Tray 10 + 96 14-557-698 LH-LF790301 10033-076 LH-LF791001 LH-LF790301 SafetySpaceTM SafetySpaceTM Filter Tip Low Filter Ret. Tip 5-300 Low µl Ret. 5-300 52.5 mm µl Single 52.5 mm Tray Single Tray 10 + 96 10 + 96 SafetySpaceTM Filter Tip Low Ret. 50-1000 µl 78 mm Single Tray 10 + 96 14-557-699 LH-LF791001 10033-078 LH-LF791211 LH-LF791001 SafetySpaceTM SafetySpaceTM Filter Tip Low Filter Ret. Tip 50-1000 Low Ret. µl 50-1000 78 mm µl Single 78 mmtray Single Tray 10 + 96 10 + 96 SafetySpaceTM Filter Tip Low Ret. 50-1200 µl 90 mm Single Tray 10 + 96 LH-LF791211 10033-080 LH-LF791211 SafetySpaceTM SafetySpaceTM Filter Tip Low Filter Ret. Tip 50-1200 Low Ret. µl 50-1200 90 mm µl Single 90 mmtray Single Tray 10 + 96 10 + 96 Sartorius Low Retention Tips, Single Tray Sartorius Low Retention Tips, Refill Tower

Visit Us BN1218134