To perform an exam, begin by selecting which type of exam you wish to perform. The exam type will always default to the last exam type you selected.

Similar documents

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

ReSound Forte and ReSound Smart 3D App For Android Users Frequently Asked Questions

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Connectivity guide for. BeMore app

Patients & Physicians

Demo Mode. Once you have taken the time to navigate your RPM 2 app in "Demo mode" you should be ready to pair, connect, and try your inserts.

Connectivity guide for ReSound Smart 3D app

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

Simple Caption Editor User Guide. May, 2017

Using the Eraser Tool for Occlusal Reduction

Items in the package:

TruLink Hearing Control App User Guide

CentriVet GK Blood Glucose & Ketone Monitoring System

Fandrich-Rhodes Weightbench Instructions

TruLink Hearing Control App User Guide

E L E C T R O N I C VA P O R I Z E R S. User Manual

Connectivity guide for ReSound Smart 3D app

Diabetes Management App. Instruction Manual

MedRx HLS Plus. An Instructional Guide to operating the Hearing Loss Simulator and Master Hearing Aid. Hearing Loss Simulator

ArcEquine User Manual

Quick guide to connectivity and the Interton Sound app

Hearing Control App User Guide

Blood Glucose & Ketone Monitoring System

Thrive Hearing Control Application

SANAKO Lab 100 STS USER GUIDE

Step-by-Step RECD Guide

Electroconvulsive Therapy (ECT) Patient Information Leaflet

System. User Manual for Self-Testing

Share/Follow. User Guide. A feature of Dexcom G5 Mobile CGM System

SU UPRIGHT OWNER S MANUAL PLEASE CAREFULLY READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR UPRIGHT!

HRM Triax 100 is engineered to provide quick, one-touch access to a variety of critical information during training and in competition.

CONSOLE GUIDE & SET-UP INSTRUCTIONS STANDARD CONSOLE

Custom instruments. Insio primax User Guide. Hearing Systems

ShadeVision v Color Map

Voice Switch Manual. InvoTek, Inc Riverview Drive Alma, AR USA (479)

Monitor Instructions for Models: CHB-R6 CHB-UV6

Coach Morse - Morse Code Practice Unit

OTM1 OARTEC SLIDER USER MANUAL Software Version 2.11

Actiwatch. Clinician Guide

Quick guide to connectivity and the ReSound Smart 3D app

Electroconvulsive Therapy (ECT) Patient Information Leaflet

MINI MASSAGER. Relaxation,Anywhere, Anytime

Sanako Lab 100 STS USER GUIDE

CONSOLE GUIDE & SET-UP INSTRUCTIONS STANDARD CONSOLE

MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015

TRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

Tips for Youth Group Leaders

Electroconvulsive Therapy (ECT) Patient Information Leaflet

Beltone Solus Pro 1.9 Fitting Guide

GLOOKO FOR ios MIDS USER GUIDE

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler

1724 Lab: Frog Skeletal Muscle Physiology (Marieb Exercise 16A) Marieb/iWorx / Ziser, 2002

Testing Digital Hearing Aids

ssociation of Children s Diabetes Clinicians Clinicians Continuous Glucose Monitoring (CGM) Training for Healthcare Professionals and Patients

Thrive Hearing Control Application

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

Video Captioning Basics

TRAINING MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

EKG and Sound.

How to use mycontrol App 2.0. Rebecca Herbig, AuD

Neuro-Audio Version 2010

How to use mycontrol App 2.0. Rebecca Herbig, AuD

RELEASED. first steps. Icon Icon name What it means

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

How to use your gonal-f pre-filled pen

Blood Glucose Monitoring System. User Guide

MINI MASSAGER. Relaxation, Anywhere, Anytime

Dear Embrace Owner Embrace N0 Code

BLINDED MODE USERS GUIDE SUPPLEMENT

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

ShoreTel Trunk Side Integration Guide

ATLANTIS WebOrder. ATLANTIS ISUS User guide

How to install the Wahoo RPM Cadence on your bike: How to install the Wahoo RPM Cadence using the Shoe Clip Mount:

The following describes general use of ELIOS device

Version February 2016

iworx Sample Lab Experiment AN-5: Cockroach Leg Mechanoreceptors

CROS System Initial Fit Protocol

CoaguChek Outpatient Clinic: CoaguChek XS - Quick Reference Guide

PROFESSIONAL CARE OXYJET air. powered. Downloaded from manuals search engine. filter. OxyJet

Table of Contents Morning Set-up (GSI equipment, only)... 2 Opening AudBase... 3 Choosing a patient... 3 Performing Pure-Tone Air & Bone

SPORTSART C521M BI-DIRECTIONAL BIKE

SymlinPen (SĬM-lĭnPen) 120 (pramlintide acetate) Pen-Injector

Nord.cTracICA.Cr USER'S MANUAL A CAUTION QUESTIONS? .. Visit our website'at. new products, prizes, fitness tips, and much more!

Welcome! With a little effort you can have a big effect

Contour Diabetes app User Guide

Dräger Alcotest Handheld Product Suite

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe

Guess: Correct or Incorrect. Trial (perform in random order)

Heart Rate and Body Position

Lightened Dream. Quick Start Guide Lightened Dream is a dream journal designed to wake you up in your dreams.

ELECTROMYOGRAM ANALYSIS OF MUSCLE FUNCTION INTRODUCTION

User Instruction Manual. Read this User Instruction Manual carefully before you start testing.

How to use FitDay.com to track your calories (v1.0)

Sleep Shepherd. BIue. User Manual

Motorised Treadmill Model No: JI1625

Transcription:

Exam To perform an exam, begin by selecting which type of exam you wish to perform. The exam type will always default to the last exam type you selected. Your exam type choices are Source (Yuan) Points, Jing-well Points, Ryodoraku Points, and Single Point. A description of each follows: Source (Yuan) points are the most energetically active points on the channels, with 4-6 times more energetic activity than other points. These points are most associated with the internal organs and with the general energetic state of the channels. Source point graphs tend to show greater variability than Jing well graphs, and therefore tend to manifest imbalances more readily than Jing well graphs. Tsing (Jing-well) points are the beginning and ending points of the 12 main meridians, and are the connection points between the main channels and the tendino-musculo branches. These points were used more than 50 years ago by Kobei Akabane to measure meridian energetics using the novel approach of counting the number of strokes of burning wood across the point required to produce the sensory perception of heat. For this reason, these points are sometimes referred to as Akabane Points.

Since then, these methods were adapted to electronic measurement, with good results. Jing well graphs measure the general energetic balance of the meridians, as do Source point graphs. The Jing well points, because they are the connections to the tendinomusculo branches, may tend to reveal imbalances associated with musculoskeletal complaints, as well as more chronic conditions. Jing well graphs do not show as much variability as Source point graphs, but the variability they show is clinically important. If the Jing well points show imbalances, these must be substantially corrected before the Source point imbalances can be successfully addressed. Therefore, it is a good idea to, at least initially, take both types of measurements on patients. Ryodoraku examination is generally used in Japanese Ryodoraku acupuncture, as pioneered by Yoshio Nakatani, MD, PhD in the early 1950 s. This exam uses Source points for 8 of the 12 meridians, but uses other points for the Small Intestine, Large Intestine, Kidney and Bladder meridians. These are the points Dr. Nakatani originally incorporated into his method. This exam is for those wishing to perform traditional Japanese Ryodoraku Acupuncture. For more information about Dr. Nakatani and the development of Ryodoraku acupuncture, please visit the AcuGraph website at www.acugraph.com. Single Point Exam: This exam is designed for the repeated measurement of a single acupuncture point to assess skin resistance responses to various stimuli. At the completion of each measurement, a dot is placed on the graph with the measured value plotted. Subsequent measurements are then plotted and connected to show the relative change in the readings (see illustration, below.) This exam does not produce any record that is saved in the software.

Screening Mode: This optional feature is available to those users who have purchased the AcuGraph Screening Module add on. When the Screening Mode icon is active, the exam only requires measurement of the hands. The purpose of this feature is to allow rapid and comfortable screening without the need for the patient to remove his or her shoes. Because the screening exam is not a complete exam, treatment information is not available for this exam. The screening exam may be used to print the AcuGraph Screening Report a very useful report for public screening and practice-marketing events. To purchase the AcuGraph Screening Module, please contact your AcuGraph distributor. Speaking Exam: The AcuGraph software provides audio direction during an exam so the user can focus on the patient without the need to continually look at the computer screen. The voice prompts during the exam speak the name of the point to be measured next. The volume level of the voice prompts and the probe tones can be set with the sliders on the exam screen. Skin Tone: The AcuGraph software allows you to choose the skin tone of the pictures shown during the exam. To select between light and dark skin tone, visit the "Measurement" tab of the Preferences section.

Performing an exam is quite easy and straightforward. The following tips will help you perform exams quickly and accurately: Probe Tip: Insert a cut cotton swab in the probe end so that the cotton of the swab makes good contact with the metal of the probe tip. Standard cotton swabs are generally readily available at drug stores and medical supply companies. We also offer pre-cut swab tips on our website at www.acugraph.com. Moisture: Moisten the cotton generously with water or saline solution, and shake off any excess. An easy way to do this is to keep a small spray bottle near your AcuGraph unit to occasionally spray the probe tip during exams. You may wish to lightly tap the moistened probe once on a towel to remove excess moisture after moistening the tip. The probe tip should be damp enough to leave a small moist spot on the patient's skin, but not wet enough to drip or run. Be careful to not get any other part of your AcuGraph unit wet. Do not use distilled water to wet the probe tip. Standard tap water, mineral water, or saline solution are all acceptable choices. For best results you should re-wet the probe tip after completing about 12 readings. A convenient time to re-wet the probe is when moving from reading the hands to reading the feet. Hand Mass: Have the patient hold the hand mass with a medium grip in one hand. The hand selected is not important, and may be changed for convenience. A tight grip is not necessary. In the case of a Tsing (Jing-well) point exam, have the patient hold the hand mass in the hand opposite the hand being examined. Point Location: Be consistent in your point locations. Use the same point and same landmarks on the left side that you used on the right side. This may sound obvious, but

careless point location is the number one cause of erroneous readings. A difference of just a few millimeters can change the reading significantly. Training Mode: If you are unsure of proper point location, or unable to duplicate consistent readings on the same patient, try using the Training Mode of measurement. This feature is activated in the Measurement window of the Preferences section. When the Training Mode is active, each measurement consists of the following two steps: 1. Locate the point precisely: Contact the patient s skin with the probe in the vicinity of the acupoint to be measured. Slowly slide the probe across the skin until a sharp increase in the reading is noted. This sharp increase indicates you have located the point exactly; this is where to take the reading. If you move off the point, simply move back on until you have located the point of the highest reading. Now remove the probe from the skin. 2. Measure the point: Place the probe at exactly the point of highest reading you located in step one. The probe will read for two seconds to allow the reading to stabilize, then will capture the reading into the software. Now move on to the next point and repeat steps one and two. Careful point location in this manner will produce very consistent and reliable graphs. Always take the reading at the point of highest conductance. Once you have practiced enough to feel confident in your point locations, you may deactivate the Training Mode in the Preferences section. Pressure and Angle: Be consistent in pressure and vector of probe placement. Light pressure of 1-3 ounces is adequate, and the angle of the probe tip to the skin should always be perpendicular. To keep pressure consistent, simply rest the probe on the skin, with the weight of the probe being the only pressure used. Timing: To take accurate measurements, you should hold the probe on the acupoint until the readings stabilize, usually 1-3 seconds. Due to the nature of the tissue being measured, readings may never completely stabilize on a single number, but readings will reach a plateau of slower movement after 1-3 seconds of measurements. This is the time to take the measurement. To take the measurement, simply remove the probe from the skin; the measurement will automatically be entered into the correct field in the program, and the probe controller

will emit a short double-beep sound to indicate the measurement was accepted. Timed Measurements: If you prefer to take all your measurements after a timed measurement interval, you can set the measurement interval in the preferences area. With an automatic timed measurement interval, simply hold the probe on the point with correct technique until you hear the double-beep sound indicating the measurement has been taken. Then move to the next point. Technique: Measurements will be most accurate when the skin is contacted and released with a quick, intentional movement. When you are ready to record the measurement, remove the probe from the skin with a quick movement. If the software is not capturing the correct value (i.e. the value drops sharply) when you lift off a point, you are probably not lifting the probe off the patient quickly enough. It may take a little practice to achieve best results. Correcting Errors: During the examination, if you take an erroneous reading or you wish to repeat a measurement for any reason, you may move back to a specific point by holding the SHIFT key and pressing the TAB key on your keyboard. Each press of the TAB key will move backwards in the exam by one field. You may also simply click with the mouse in the field for the measurement you wish to take. Manual Entry: You may also enter measurements manually by typing the values into the measurement fields and moving between fields with the TAB key. If you choose to manually enter values, the AcuGraph probe still must be attached to the computer to access the exam screen. If you want to start the exam over, simply press the Restart Exam icon. Any values already entered will be erased and the exam will start over at the beginning. When you take the last measurement with the probe, AcuGraph will automatically save the measurements and display the patient's exam results. A NOTE ABOUT READING CONSISTENCY: Some users attempt to determine the accuracy of the AcuGraph exam by performing back-to-back exams and comparing them. They are disappointed to note that readings are not always the same when a meridian is examined twice or more in a short period of time.

This occurs because the act of measuring an acupuncture point causes a certain amount of electric charge to course through the meridian being measured. Studies have shown that acupuncture meridians display capacitance or the ability to store electric charge. This means that the act of taking the first reading charges up the meridian, and subsequent readings for the next several hours may be affected by this artificial change in charge. Therefore, it is most correct and reliable to use the results from the first exam obtained, rather than repeating an exam a few minutes after the previous exam. Similarly, it is not effective or accurate to perform an exam directly after treatment. Best results are obtained by waiting at least 24 hours between exams. Intentional, repeated measurements are a misuse of this equipment, and provide no clinically relevant or accurate information. By following these guidelines, you'll find your readings to be consistent, accurate and reliable. For additional training in reading technique and interpretation, consider one of our live seminars or seminars on DVD. Visit www.acugraph.com for more information.