Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators

Similar documents
Neutrons. ρ σ. where. Neutrons act like photons in the sense that they are attenuated as. Unlike photons, neutrons interact via the strong interaction

Neutron Detection Spring 2002

The title of the presentation is: Neutron production with clinical LINACs for BNCT studies in physical, medical and biological fields.

CLAS12 FTOF Studies: Rate and Magnetic Shielding Effects on PMT Timing Resolutions

Characteristics of PMT used in prototype array of ED

Epithermal neutron beams from the 7 Li(p,n) reaction near the threshold for neutron capture therapy

SoLID EM calorimeter study and general test system in SDU

Title. Author(s)Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; H. CitationJournal of Radiation Research, 56(2): Issue Date

Neutron Interactions Part 2. Neutron shielding. Neutron shielding. George Starkschall, Ph.D. Department of Radiation Physics

THERMOLUMINESCENT (TL) DOSIMETRY OF SLOW-NEUTRON FIELDS AT RADIOTHERAPY DOSE LEVEL

Neutron Measurements for Intensity Modulated Radiation Therapy

Thermal and Fast Neutron Detection with two CLYC Scintillators

V. 4. Design and Benchmark Experiment for Cyclotron-based Neutron Source for BNCT

Optimization of an accelerator-based epithermal neutron source for neutron capture therapy

Today, I will present the second of the two lectures on neutron interactions.

Development of a Thermal Neutron Source based on a Medical Electron Linac

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

Boron Neutron Capture Therapy (BNCT) - Low-Energy Neutron Spectrometer for Neutron Field Characterization - )

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Neutron dose evaluation in radiotherapy

Single Photon Emission Tomography Approach for Online Patient Dose Assessment in Boron Neutron Capture Therapy

NaI Detector and Photo-multiplier Tubes

Radiation Monitoring Instruments

Radiation Dosimetry at the BNL High Flux Beam Reactor and Medical Research Reactor


Progress in Reactor and Accelerator Based BNCT at Kyoto University Research Reactor Institute

Djoko S. Pudjorahardjo, Widarto, Isman Mulyadi T

THE HIGH-CURRENT DEUTERON ACCELERATOR FOR THE NEUTRON THERAPY. S.V. Akulinichev, A. V. Andreev, V.M. Skorkin

Design of a BSA for Producing Epithermal Neutron for BNCT

EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS

IPPE Iron shell transmission experiment with 14 MeV neutron source and its analysis by the Monte-Carlo method

Design and Performance Of A Thermal Neutron Beam for Boron Neutron Capture Therapy At The University Of Missouri Research Reactor

Task Test beam infrastructure in Frascati LNF, Ferrara & Perugia INFN structure and University of Bergen

SIMULATION RESPONSE OF RESISTIVE PLATE CHAMBER FOR FAST NEUTRONS USING GEANT4 MC CODE

procedures Photomultiplier tests - Requirements for SNO and standardized testing ^o^-t/l-jo-^z, R.J.Boardman 1 Abstract April 5, 1990

Imaging of Radiation Dose Using Cherenkov Light

Neutron - a tool in the cancer treatment - C. Paunoiu

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

New 50 cm Photo-Detectors for Hyper-Kamiokande

Preliminary study of MAGAT polymer gel dosimetry for boron-neutron capture therapy

Thin Quartz Detector R&D and PMT Linearity Studies

Chapter 4 RADIATION MONITORING INSTRUMENTS

The ANDANTE project: a multidisciplinary approach to neutron RBE

MCP PMT with high time response and linear output current for neutron time-of-flight detectors

A Feasibility Study of the SLOWPOKE-2 Reactor as a Neutron Source for Boron Neutron Cancer Treatment

COMPARING THE RESPONSES OF TLD 100, TLD 600, TLD 700 AND TLD 400 IN MIXED NEUTRON-GAMMA FIELDS

Chapter 4: Radiation Monitoring Instruments

GDR in Radiotherapy Treatment Fields with 18 MV Accelerators

III. Proton-therapytherapy. Rome SB - 5/5 1

5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany

arxiv: v1 [physics.ins-det] 1 Feb 2015

Distribution of Water Phantom BNCT Kartini Research Reactor Based Using PHITS

Neutron sources based on medical Linac

Application(s) of Alanine

Plastic scintillation detectors for dose monitoring in digital breast tomosynthesis

On the optimal energy of epithermal neutron beams for BNCT

nuclear science and technology

Medical Use of Radioisotopes

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Venue: IEEE NSS/MIC/RTSD Conference, Seoul, South Korea, 27 th October 2013 Workshop: NWK3/RD1 Radiation Protection and Dosimetry

AUTHOR QUERIES - TO BE ANSWERED BY THE CORRESPONDING AUTHOR

Nuclear Medicine and PET. D. J. McMahon rev cewood

RPI DOSIMETRY. Therefore the description of the work is grouped in two main areas:

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

Chapter Introduction

Detailed performance evaluation of a new 20-inch photomultiplier tube with a Box and Line dynode

The Albedo Dosimeter for Personnel Monitoring in Fast-Neutron Radiation Fields

Inhomogeneity effect in Varian Trilogy Clinac ix 10 MV photon beam using EGSnrc and Geant4 code system

Modelling the induction of cell death and chromosome damage by therapeutic protons

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

PGY-1. Resident Review Session Schedule

Double Chooz results at the double detector phase

Radiotherapy. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Thin Beryllium target for 9 Be(d,n)- driven BNCT

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

Neutron Induced Radiation Damage in BaF 2, LYSO and PWO Scintillation Crystals

The SpecMAT Project: An array of gamma ray detectors around an active target

Radiologic Units: What You Need to Know

The DAΦNE Beam Test Facility & AGILE Calibration

Multilayer Gafchromic film detectors for breast skin dose determination in vivo


Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

Study on Microdosimetry for Boron Neutron Capture Therapy

A brief presentation of The TERA Foundation

Study of neutron-dna interaction at the IPEN BNCT Research facility ABSTRACT

Environmental Testing of NI Products for Big Physics Applications

Feasibility study to develop BNCT facility at the Indonesian research reactor

George Washington University, Washington D.C, USA M.Sc. EE/Biomedical Engineering (Medical Imaging) 2002

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Application of the Multi-Model Monte-Carlo Treatment Planning System Combined with PHITS to Proton Radiotherapy

Numerical optimisation of the fission-converter and the filter/moderator arrangement for the Boron Neutron Capture Therapy (BNCT)

Radiation Detection and Measurement

Recent Progress in Vacuum Photon Detectors at Hamamatsu

Simulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation

Test Setup to Measure Gains of the Angra Photomultipliers Using the Single Photoelectron Technique

Neutron sources from Nuclear Reactors

Radiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp Advance Access publication 21 May 2007

Option D: Medicinal Chemistry

Dosimetry in digital mammography

Transcription:

Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators Aldo Mozzanica, Università degli Studi di Brescia, INFN sezione di Pavia mozzanica@bs.infn.it

2 Outlines The Boron Neutron Capture Therapy Neutrons from medical LinAcs Currently used neutron detectors Proposed detector working principles Detector and electronics description Results for flux evaluation and comparison with standard methods Spectral information from ToF Future improvements Conclusions

3 The Boron Neutron Capture Therapy Boron Neutron Capture Therapy (BNCT) is an oncology radiotherapy treatment that exploits the capture of thermal neutrons by 10B and the following emission of an particle and a nucleus of 7Li. n+10b -> + 7Li + 2.972 Mev Boron is delivered mainly to tumoral cells; specific drugs are being developed for this purpose 10B thermal neutron cross section is 103 104 times greater than body tissue one. Short range (<10 m) and high Linear Energy Transfer (LET) High damage only in the target cells 10 B-Phenylalanine, best candidate for 10 B displacement A real hope for some kinds of tumors like extended tumors (lung, liver, pancreas, skin) or tumors located in particular positions (brain).

4 The BNCT with wide-spread Radiotherapy accelerators: the PHONES project A big issue for the BNCT is the need of a nuclear reactor providing a suitable thermal neutron flux. The aim of the PHONES project is to provide a competitive thermal neutron source using clinical radiotherapy linacs. High energy photons (>10 MeV) hit an high Z target Fast Neutrons are produced by Giant Dipole Resonance Neutrons are slowed down by moderating materials Neutron capture inside the device should be kept low With as low as possible residual gamma field To obtain PHOton NEutron Source useful for medical purposes the following requirements have to be fulfilled: n A thermal neutron flux greater than 108 cm2 s A fast neutron and gamma dose per thermal neutron lower than 2*10-12 Sv cm2 n

5 PHONES project/2 Different prototypes and simulations have been developed (2005-2006) for optimizing the following parameters: Photoconverter Lead thickness Moderator shape and thickness Moderator material (D O vs. H O) 2 2 The first prototype of the PHONES photon to neutron converter faced to the Varian Clinac 1800 head at Sant'Anna Hospital - Como Best PHONES converter results, so far: Thermal neutron flux n 1.8x107 ±.1x107 2 cm s Fast neutron dose 2 12x10-12 Sv cm n In this framework a development of neutron detection methods for direct and diffused dose evaluation is of primary importance.

6 Commercial Neutron detectors: Bubble dosimeters Integral measure over time and energy Slow and not automatic readout Single shot (need hours to recovery) Poor spatial resolution TLDs Integral measure over time and energy Slow readout Calibration needed Also sensitive to photons High dynamic range BF3 counters Real time readout Gas detector with almost fixed geometry (anode wire) and size High electronics dead time (shaper) Material Activation Integral measure over time and energy A Ge o NaI detector nearby is needed. Usually one sample per time. Almost real time.

7 Can Boron loaded plastic scintillators with photomultiplier readout be successfully used? Very difficult due to the high photon/neutron ratio But the bunched particle emission suggests a different approach... Beam time structure (Varian Clinac 1800): electrons (as well as secondary photons) are emitted in a 3-5 s wide bunch at 50-150 Hz repetition rate (dose rate dependent) It means up to tens of ms empty time between two following bunches. ms 4 s Bunch emission waveform obtained under the beam with a low gain scintillation detector In this time interval there are no more electrons nor photons in the environment, only neutrons survive. --> Low background for neutron detection. Of course our detector should be sensitive also to neutrons.

8 Plastic scintillators are sensitive to neutrons in a wide energy range: Fast neutrons: neutron recoil on protons (mainly H atoms) proton energy being limited by neutron one, this process can work with neutrons with energy > 0.5-1 MeV For Slower neutrons we can take advantage of: 1H(n, )2H -> photon easy to detect (provided it stops in the sensitive volume ) Plastic scintillators are rich in Hydrogen: e.g. Hydrogen in polystyrene is 7% in mass and 50% in atom number = 0.33 barn E = 2.2 MeV Elastic scattering cross section Neutron capture cross section From Endef/Exfor database

9 A preliminary evaluation of our energy acceptance Much geometry dependent; Suppose: A bunch time width (jitters and detector dead time included) of 20 s A distance between the detector and neutron photo production region of 20 cm The fastest neutrons the detector is able to see have an energy: 20cm/2*10-6s = 10000 m/s 1.4 ev => still in epithermal neutron range, but increase with the square of the distance the slowest neutron, supposing a 20ms interval between bunches: 20cm/20*10-3s = 10 m/s < 1 ev Estimate of the number of neutrons per bunch detected * T* *N *E 250 Where is the expected flux, the cross section evaluated at 2200 m/s, N the number of H atoms in the detector, E the detector efficiency for 2.2MeV simulations) (3%, from Geant 3.2

10 Scintillator mechanical sample The detector: A polystyrene plastic scintillator 2x2x1cm3 Primary scintillation fluorine pterphenyl (PTP) - 1% weight Secondary fluorine bis-msb 0.01% Two 1 P30CW5 photomultipliers by Electron Tubes with integrated high voltage power supply facing the two opposite sides of the scintillator to avoid dark counts and improve reliability. PMTs Voltage = 1230 V The detector assembly

11 signals on the oscilloscope (1 PMT, 50 Ohm) end of the Linac bunch detector recovery (from a 1011-12 particle bunch!) 15 s spikes are signals from captured neutrons Our detection system should be able to return the number of captured neutrons and their arrival time. P.H. Information not used at the moment. The read out electronics: Signals from scintillator are digitized by a NIM discriminator, threshold 30mV The coincidence between the two scintillators (width 200ns)is shifted to LVDS and then to sampler.

12 The read out electronics/2: Digital sampling done by one Altera Cyclone II FPGA Board developed by INFNTS for VATAP2.1 asic digital read out. Analog section not used sampling up to 4 LVDS inputs Sampling rate up to 640MHz 1 Mbit on-chip memory Parallel data transfer (8bit) to a VME I/0 board SBS Bit3 bridge from VME bus to PC Trigger (on the bunch emission) given by the Linac itself For this measurements a 65536 bit shift-register has been implemented At 12.5MHz sampling frequency -> 5 ms wide acquisition gate Comparable dead time during data transfer to PC

13 Output example: each '111' corresponds to an impinging neutron. For each experimental condition several been collected. bunches have Obtaining an arrival time profile : 0000000000000000000000001110000000000000000000 0000000000000001110000000000000000000000000000 0000000000000000000000000000000001110000000000 0000000000000000000000000000000000111000000000 0000000000000000000000000000000000000000000001 1100000000000000000000000000001110000000000000 0000011100000000000000000000000000000000000000 0000000000000000000001110000000000000000000000 0000000000000000000000000000000000000000000011 Detector at 16 cm from Linac head, no moderator Profile over 1000 Linac bunches -> 600 hit per bunch The total number of hit is, bunch per bunch, proportional to the neutron flux.

14 Comparison with Al activation method: Al cylindric sample, 1cm radius, 0.5cm thickness NaI 2 x2 detector from Saint-Gobain, Ortec spectroscopy chain, CAEN V785 ADC. Correction for dead time. Efficiency obtained from Geant Simulation Capture - Hydrogen Capture - Aluminum Capture cross section comparison: Both Show 1/v behavior for Al 0.45 times smaller than the H one up to 2*103 ev. Over 2*103 ev for Al is greater: integrated cross section from 2*103 ev to 106 ev : 47eV*barn (H) vs. 880 ev*barn (Al) From Endef/Exfor database

15 Comparison with Al activation method /2: different measurements have been taken varying the distance from the linac head flux on scintillator has been evaluated counting the number of detected neutrons in the sampling gate this number has been compared with neutron flux from Al activation a normalization is needed Normalized flux (A.U.) good agreement up to 250 cm; for greater distances a bigger fraction of fast neutrons enters our gate point at 90cm shows scintillator saturation This distance corresponds to 1keV n entering the gate

16 Comparison with Al activation method /3: The Neutron flux has been measured in different positions on the back side of the Phones Moderator (1st prototype) and onaxis up to 160cm (point 8) normalized to position 5 at greater distances the detector overestimates the flux being sensitive to higher energy neutrons still follows flux variations 1 Scintillator saturation 5 6 sensitive to positioning errors 8 7 3 2 4

17 Comparison with BF3 counter BF3 counter scintillator Saturation region A 62cmx5cm cylindrical BF3 counter (Politecnico of Milan) Discriminated signal from the counter sent to the same daq after shaping BF3 and scintillator in the same position Profile over 1000 bunches Data has been normalized (different cross sections and sizes) Good agreement after 1.5 ms. Saturation effect for BF (due to a 10 3 s shaping time) from.8 to 1.5 ms. Extreme BF3 saturation soon after the bunch The same validation has been repeated at different positions.

18 Towards the ToF In principle the arrival time of a neutron depends on the speed (energy) and the path, but: absolutely no point-like source moderator thickness and travel comparable possible walls backscatter A true energy spectrum measurements possible only with MC simulation comparison. A trial... Measurements with the detector as far as possible from the Phones moderator (161cm), on axis. Neutron energy has been calculated from arrival time data Preliminary results. No correction for the cross section energy dependence included. No cross-check with other detector available. Residual gamma field blinds the detector for a longer time (on axis), lowering Emax

19 Future developments /1 To extract the maximum information from our detector Monte Carlo simulations are needed. MCNP4b-GN simulations will allow to: calculate the ratio between total and detected neutrons to reach a better flux evaluation obtain neutron spectra at the exit face of the moderator, to allow a calculation of the arrival times on a far away detector. Time domain (e.g. Geant 4) simulations to: obtain directly the arrival time spectrum on our detector adjust parameters to match measured data overall detector efficiency for an absolute flux measurement.

20 Future developments /2 Multi channel system for the mapping of the neutron field: From the electronics point of view: Straightforward upgrade to a 64 channel system exploiting the VA64TAP2.1 on board ASIC and one Hamamatsu multianode photomultiplier For the detector: A multi channel module with bulk sensitive scintillators and optical fiber readout will be designed, taking into account mainly the range of the 2.2 MeV gammas (shielding..) The front-end board connected with a 64 channel Hamamatsu MAPMT The VATA642.1 ASICS from IDEAS, providing amplification, fast shaping, discrimination and parallel trigger output.

21 Standard H (0.025eV) =.33barn - 1/v dependence atom density H = 1 5.2x1022 cm Efficiency = 3% (geo. dep.) 3 Boron loaded 10 B (0.025eV) = 3840 barn - 1/v dependence atom density B10 = 1 5.6x1020 cm efficiency = 100% Boron loaded scintillator detects up to 3*103 more neutrons for our fluxes saturation will occur much more expensive but useful if very small volumes are needed 3 Data from Bicron BC-454 datasheet Can a Boron loaded scintillator improve our system?

22 Conclusions A neutron detector useful in a medical Linac environment has been developed the comparison with activation methods states that it can give relative measurements of neutron fluxes. Has been cross-checked with a BF3 counter A powerful method providing also spectral information Monte Carlo simulations foreseen for this purpose Multi channel device for neutron field mapping is being developed.

23 Thanks... To the whole Radiotherapy Division of S. Anna Hospital, Como