Testing Inhaled Generics

Similar documents
Caption: The equipment required for testing Fluticasone Propionate (FP) Inhalation Powder in line with a new product-specific monograph (USP36-NF31).

Go With the Flow REGULATORY LANDSCAPE. Mark Copley at Copley Scientific

Understanding cascade impaction and its importance for inhaler testing

Characterizing the Performance of Metered Dose Inhalers with Add-On Devices: New Methods For Clinically Relevant Testing

Assessing the role of breathing simulators in OIP testing

INTRODUCTION. size and total nozzle area decrease with stage number. Volumetric air flow rate through

Draft Guidance on Fluticasone Propionate; Salmeterol Xinafoate. Fluticasone Propionate; Salmeterol Xinafoate. Powder/Inhalation

Assessing Quality of Inhaled Products And Links to Efficacy and Safety

Inhalation Product Research at FDA

Device Design Similarity

Drug/Device Combination Products: Bioequivalence

OPTIMISING ANALYTICAL STRATEGIES FOR THE DEMONSTRATION OF BIOEQUIVALENCE IN A GENERIC NEBULISER

COMMENTS. Submitted by The International Pharmaceutical Aerosol Consortium

EPAG Perspective - Regulatory Advances Related to Nasal Spray Pumps. Dr G.Williams Nasal Drug Delivery Management Forum London, 15 Apr 2010

Optimising the application of in vitro test methods for the demonstration of bioequivalence in orally inhaled products

Current Challenges and Opportunities in Demonstrating Bioequivalence

Equivalence Evaluation of Valved Holding Chambers (VHCs) with Albuterol Pressurized Metered Dose Inhaler (pmdi)

Metered Dose Inhalers (MDIs) In Vitro Measures to Confirm Patient Perceptions: HFA vs. CFC

International Pharmaceutical Aerosol Consortium on Regulation and Science

University of Groningen. Technology in practice Lexmond, Anne

Qualifying Container Closure Systems for OINDP: Current & Future Regulatory Expectations. Julie D. Suman, Ph.D. November 14, 2014

Year in review. Vit Perlik Director of Regulatory Science and Clinical Development

DISSOLUTION TESTING - Exploring the Link Between Particle Size & Dissolution Behavior for OINDPs

Understanding Regulatory Global Requirements for Nasal Drug Products. Julie D. Suman, Ph.D. April 8, 2016

IMPROVING THE REALISM AND RELEVANCE OF MOUTH-THROAT MODELS FOR INHALED PRODUCT TESTING

Generic Inhaled Medications

Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U.S.A. Phone: Fax:

Sub-components in Nicotine cessation products?

Implications of the new CHMP Guideline on the Pharmaceutical Quality of Inhalation and Nasal Products

Considerations for Evaluation of Bioequivalence and Interchangeability of Orally Inhaled Products

The Role of EPAG in Standards and Regulatory Guidance Development

Biopharmaceutics of Non-Orally Administrated Drugs

Lawrence X. Yu, Ph.D. Director (acting) Office of Pharmaceutical Science Food and Drug Administration

MDI. Recommended Equipment

IPAC-RS/UF Orlando Inhalation Conference March 20, S.T. Horhota 1, C.B. Verkleij 2, P.J.G. Cornelissen 2, L. Bour 3, A. Sharma 3, M.

Orally Inhaled Corticosteroids to 2022

A NEW, ADVANCED HIGH- THROUGHPUT SYSTEM FOR AUTOMATED INHALER TESTING

Adapting Pharmacopeial Testing for Pharmaceutical Equivalence Studies. Julie D. Suman, Ph.D. March 29, 2016

Dry Powder Inhaler. Developing an Efficient. 3M Conix DPI. White Paper / Spring Proven Solutions that Enable Your Success

The abbreviated impactor measurement concept

Quality of Nasal and Inhalation Drug Products

Technology and Quality of Inhalation Drug Products

Last updated: July 2011

COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP) GUIDELINE ON THE PHARMACEUTICAL QUALITY OF INHALATION AND NASAL PRODUCTS

COPLEY SCIENTIFIC. Quality Solutions for Inhaler Testing. metered-dose inhalers dry powder inhalers nebulisers nasal sprays

Patient. Device Clinician. Safety & efficacy

REDUCING VARIABILITY IN TEST RESULTS FOR OINDPS WITH AUTOMATED ACTUATION

COPLEY SCIENTIFIC. Quality Solutions for Inhaler Testing Edition. metered-dose inhalers dry powder inhalers nebulisers nasal sprays

PRACTICES OF COATING COLLECTION SURFACES OF CASCADE IMPACTORS: A SURVEY OF MEMBERS OF THE EUROPEAN PHARMACEUTICAL AEROSOL GROUP (EPAG)

Meeting the Quality Challenge for Orally Inhaled Drug Products. Review Impact of Emerging EMA/MHRA Guidelines and Standards

What Do Cascade Impaction Measurements Tell Us: In Vitro Aspects. Context of Presentation

in the ICH Regions Table of Content Annexes to Guideline and 3. Why is Q4B necessary? Q4B Annexes? for Human Use

EPAG Sponsored Workshop on Abbreviated Impactor Measurement (AIM) and Efficient Data Analysis (EDA) Concepts in Inhaler Testing. Overview of AIM EDA

Patricia KP Burnell Inhalation Product Development

Philippine Strategy for the. Free Alternatives. under the National CFC Phase-out Plan (NCPP)

PREMIXES FOR MEDICATED FEEDING STUFFS FOR VETERINARY USE. Praeadmixta ad alimenta medicata ad usum veterinarium. Effervescent powders

Misty Max 10 nebulizer

AEROSOL THERAPY: THE PRACTICALITIES

EVALUATION AND RECOMMENDATION OF PHARMACOPOEIAL TEXTS FOR USE IN THE ICH REGIONS ON DISINTEGRATION TEST GENERAL CHAPTER Q4B ANNEX 5(R1)

Clinical Endpoint Bioequivalence Study Review in ANDA Submissions. Ying Fan, Ph.D.

CLINICAL RELEVANCE OF IN VITRO PARTICLE SIZING DATA. Steve Newman, PhD Nottingham, UK November 2006

VARIABILITY IN CASCADE IMPACTION: SOURCES, IMPACT AND STRATEGIES FOR REDUCTION

First to Market or 505 (b)2 CMC Considerations IPAC-RS/UF Orlando Inhalation Conference Orlando, Florida

HARD TWO-PIECE HPMC CAPSULES FOR PHARMACEUTICAL APPLICATIONS IN INHALATION

Inhaled Corticosteroids for the Treatment of Chronic Asthma in Adults & Adolescents aged 12 years & over

Device Change Management for Inhaled Products. Loy Britto, Ph.D. GlaxoSmithKline ISAM Congress Munich 2015

ASTRAZENECA v GLAXOSMITHKLINE

BEDFORDSHIRE AND LUTON JOINT PRESCRIBING COMMITTEE

Process Drift and it s Resolution in the Manufacture of Drug Products. MDI s and DPI s Metered Dose Inhalations and Dry Powder Inhalations

ORANGE BOOK ORANGE BOOK

rj.;!i U.S. FOOD & DRUG - ADMIN ISTRATION

Dose. Route. Units. Given. Dose. Route. Units. Given

Public Assessment Report Scientific discussion. Salmeterol/Fluticasone Sandoz (salmeterol xinafoate, fluticasone propionate) SE/H/1323/03/DC

Advance in inhaler technique: changes in delivery devices, Authorized Generics, and Advance in technology for monitoring inhaler adherence

Teva Pharmaceuticals USA Attention: Scott D. Tomsky Vice President, US Generics Regulatory Affairs 425 Privet Road Horsham, PA 19044

ISO Process and Standards Under Development. ISO Principles

Public Assessment Report Scientific discussion. Flumetor (salmeterol xinafoate/fluticasone propionate) SE/H/1068/01-02/DC

TRAINING DEVICE OPPORTUNITIES AND SOLUTIONS FOR A CHANGING RESPIRATORY MARKET

ADVANCIA : A TRUE PLATFORM & INNOVATIVE SYSTEM OFFERING EFFICIENT NASAL DOSE DELIVERY

Bioequivalence Requirements: USA and EU

WHITE PAPER ACCESS TO GOOD QUALITY DIETARY SUPPLEMENTS

Proposal on subsidy changes for some respiratory inhalation products and access restrictions to combination inhalers.

905 UNIFORMITY OF DOSAGE UNITS

The FDA Critical Path Initiative

Work plan for the joint CHMP/ CVMP Quality Working Party (QWP) for 2018

Everything for Inhalation

Q&A for submission of applications for prequalification of Zinc Sulfate tablets and Zinc Sulfate oral liquid (solution)

Public Assessment Report. Scientific discussion. AirFluSal Aerosol 25/125 and 25/250 micrograms pressurised inhalation, suspension

Disclosure. Objectives. Objectives. Introduction. Introduction. Non-Sterile Compounding/Calculations

GMMMG Asthma Formulary Inhaler Options August 2017

Demonstrating Bioequivalence of Locally Acting Orally Inhaled Drug Products

Understanding the links between drug delivery route and in vitro test methods Mark Copley, Sales Director, Copley Scientific

Ensuring the Quality of Some Drug-Device Combination Products - FDA Perspective

Position within the Organisation

INTRODUCTION. Asthma Drug Delivery - 1

The Montreal Protocol and the Phase-out of CFC-based Metered Dose Inhalers. Paul Krajnik UNIDO, Montreal Protocol Branch

December 4, 2017 VIA ELECTRONIC SUBMISSION

INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE

Delivering Aerosol Medication in ICU

NEBULIZERS, METERED DOSE INHALERS, AND DRY POWDER INHALERS

Transcription:

Generic Bioequivalence Testing Inhaled Generics By Mark Copley at Copley Scientific New product-specific FDA guidance and USP monographs support the development of popular inhaled products. This article reviews their value in the rapidly growing generic sector Keywords Bioequivalence Inhaled route Product-specific guidance USP monographs Aerodynamic particle size distribution Central to the development of a new generic product is the need to demonstrate bioequivalence (BE) in order to confirm pharmaceutical equivalence to the reference labelled drug (RLD) being replicated. Such evidence is typically supplied in the form of in vitro and in vivo test data. In vitro tests are usually the first step and preferable to the manufacturer from the perspective of ease, cost and speed, but choosing a testing strategy that yields suitable data is also important. For certain widely used pharma products, the FDA has released product-specific guidance to support the generic submission process; drugs for administration by the inhaled route are no exception. This follows a signalled policy change in June 2010 to actively provide guidance for the demonstration of BE for specific products, rather than simply dealing with requests for information on demand (1). Designed to facilitate generic drug product availability, this guidance helps the generic industry to identify the most appropriate methodology for developing drugs and generating the evidence needed to support ANDA (Abbreviated New Drug Application) approval (2). In addition to this guidance, there are now a growing number of product-specific US Pharmacopeia (USP) monographs for inhaled products, which closely detail appropriate testing for off-patent active ingredients. The FDA and USP are discrete, independent bodies, so there is no obligation to adhere to USP monographs as part of a submission process, even though it is common practice to do so to reduce the risk of inadequate data provision. Monographs describe the tests required to ensure the substance is of the appropriate strength, quality and purity (3), and provide a standard that can be used by the FDA to assess compliance and by manufacturers to guide testing strategies. Product-specific monographs may therefore be helpful to ensure efficient generic development; however, in certain instances, they point to the use of test equipment that is not included in the USP general chapters. In this article, we examine the drivers for developing product-specific tests and explore the reasons why they may call for the use of unique equipment. A key focus are new USP monographs specified for fluticasone propionate (FP) and salmeterol, plus draft monographs for these two active ingredients in combination. These additions reflect activity to develop generic versions of Flovent /Flixotide, Serevent and Advair /Seretide respectively, the latter of which though now off-patent has proven notoriously difficult to replicate and continues to command around $6 billion in annual sales (4). Ensuring Efficiency The number of generic submissions to the FDA has risen exponentially over the last decade or so, with substantial expansion in the generic sector in particular in India, where annual growth rates remain in excess of 25% (5). A stated aim of publishing product-specific guidance is to streamline the process of providing support with the design of BE studies, as a way of improving efficiency (1). Furthermore, better quality submissions have the potential to reduce the burden of regulatory assessment without increasing risk. For generic developers, time to submission is crucial, with the potential prize of a 180-day exclusivity period in certain circumstances (6). Guidance on how to design BE studies is, therefore, valuable in ensuring an efficient development process that will result in data which can robustly satisfy regulatory requirements. While it does not appear that it is mandatory to follow the guidance, the ease and reduced risk of doing so makes it likely that such an approach will be relatively attractive. In summary then, product-specific guidance has benefits for both the regulators and generic developers alike a happy confluence of interests that perhaps helps to explain the steadily increasing number of products covered by successive guidance releases over the past few years. 22 Innovations in Pharmaceutical Technology Issue 55

Key generic targets in the inhaled area include drugs routinely used for asthma and chronic obstructive pulmonary disease (COPD). As the global incidence of respiratory illness rises, delivering safe, efficacious and inexpensive treatment is becoming increasingly important, with governments seeking to control and contain spiralling healthcare costs. Many generics are destined for home markets in developing countries, but the overall potential export market for generics is sizeable. Overall, across all pharma product types, around 40% of generic drugs and over-the-counter products used in the US are now produced by India, making FDA approval essential (7). Factors for Testing The general FDA guidance and USP chapters relating to orally inhaled and nasal drug products (OINDPs) are defined in terms of their applicability to certain product types: dry powder inhalers (DPIs), metered dose inhalers (MDIs), nebulisers and nasal sprays (8,9,10). Key tests include the measurement of delivered dose the amount of the active ingredient(s) a patient will receive under representative delivery conditions and the aerodynamic particle size distribution (APSD) of that dose. APSD influences deposition behaviour in the pulmonary system, and is used to assess the likelihood of a drug being delivered successfully to the target region within the lung. The test equipment and methods defined in the USP general chapters have evolved over a number of years, and represent the view of experts and stakeholders with regard to current best practice. This raises the question of how test methods introduced in the productspecific USP monographs differ and, indeed, why do they do so? For an ANDA submission, the defining goal is to demonstrate BE to an RLD, essentially reproducing the performance that ultimately led to regulatory approval for the original product. The fact that patents generally expire after 20 years dictates that the development work associated with the RLD is likely to have been carried out some time ago, often prior to the definition of current test methods. One way of approaching in vitro testing within this context is therefore to duplicate the test equipment and method used in the development of the original product, rather than to introduce the complicating factor of comparing results generated using a different set-up. This approach reduces the risk that the data generated such as delivered dose, impactor drug mass-per-stage or fine particle dose are influenced by the equipment type or test method used, and hence reduces the burden associated with method validation and specification setting. Monographs, unlike general chapters, typically include the name of an ingredient or preparation, and their development often begins with the manufacturers of that product drafting a document for consideration by the wider community (3). This heritage is often particularly visible in productspecific monographs, which tend to include hitherto proprietary test methods that are derived in some way from those originally deployed. Although these are broadly similar to those detailed in the general chapters, there are in certain cases some important differences. The Evolution of Inhaled Product Testing The use of inhalers to deliver drugs via the lung is far newer than traditional methods of drug delivery, such as oral solid dosage, which means the test methods associated with their development and with quality control are too. The first inhalers were commercialised in the 1950s, 60s and 70s, predominantly by large pharma companies like 3M, AstraZeneca, GlaxoSmithKline and Sanofi (or their predecessors). Ensuring the safety and efficacy of these products was essential for their introduction, so these companies led the way in evolving new test methods, with some designing and manufacturing their own analytical equipment to meet requirements (11-13). The need to move towards more standardised testing grew with the establishing market, and pharmacopoeial general chapters were subsequently established from the 1980s onwards, supported by expertise within the pioneering organisations. As a result, some proprietary equipment found its way into the resulting chapters, but some did not. Companies remained free to validate their own test methods using preferred equipment, and some continue to do so, even today. The general pharmacopoeia chapters for OINDP testing continue to evolve, reflecting on-going development and understanding, and the requirements of the market. As a result, all the relevant pharmacopoeias, including the USP and European Pharmacopoeia (Ph Eur), are not fully harmonised. For example, there is an MDI content uniformity apparatus unique to the British Pharmacopoeia for testing pressurised inhalers (14). The additional need to ensure consistent quality during the complete product lifecycle adds to the complexity of refining the general chapters to ensure best practice. 24 Innovations in Pharmaceutical Technology Issue 55

In some areas, unique pieces of equipment are specified Figure 1: Glass sample collection apparatus is specified in place of the standard dose uniformity sampling apparatus for inhalation powders (left) and for inhalation aerosols (right) both aerosol and powder, have also been proposed (22,23). The monographs for FP and salmeterol (and draft monographs for FP/salmeterol combinations) cover both delivered dose uniformity (DDU) testing and APSD measurement. The equipment specified is very similar to that detailed in the general chapters, with the Andersen Cascade Impactor (ACI) specified for APSD measurement. This is one of two cascade impactors routinely used for OINDP characterisation, the other being the Next Generation Impactor. Figure 2: The modified induction port specified for APSD measurement necessitates the use of a modified ACI pre-separator for inhalation powders (left) and a modified ACI inlet cone for inhalation aerosols (right) However, in some areas, unique pieces of equipment are specified, including: Glass sample collection apparatus specifically for DDU testing of inhalation aerosols Glass sample collection apparatus specifically for DDU testing of inhalation powders Modified induction port to be used with the ACI for all APSD measurements Modified version of the ACI pre-separator (for inhalation powders only) Modified version of the ACI inlet cone (for inhalation aerosols only) Guidance and Monographs FDA product-specific draft guidance is now available for a number of active ingredients routinely used to treat asthma and COPD. These include salbutamol (albuterol) (15), budesonide (16), FP/salmeterol (17) and, new this year, ipratropium bromide (18). This guidance references test equipment outlined in the general chapters of the USP. Product-specific USP monographs are in place for FP and salmeterol as follows: FP inhalation aerosol (MDI delivery) (2013) (19) FP inhalation powder (DPI delivery) (2013) (20) Salmeterol inhalation powder (DPI delivery) (2014) (21) Further draft monographs covering FP and salmeterol in combination, Like the glass sample collection apparatus for inhalation powders, the modified induction port specified in all five monographs for APSD measurement has an inlet geometry similar to that of the Glass Twin Impinger (GTI), indicative of its heritage (13). However, it is manufactured from either aluminium or 316 stainless steel, to match the impactor. Mouthpiece adapters designed for the GTI can be used to interface the induction port with the device, while an O-ring-less tapered exit enables interfacing with the ACI. The modified versions of the ACI pre-separator and inlet cone for inhalation powders and inhalation aerosols respectively accommodate the modified induction port. Innovations in Pharmaceutical Technology Issue 55 25

Product-specific guidance can be extremely helpful in defining in vitro test strategies The new monographs specify the 28.3L/min version of the ACI (Stages 0 to 7, plus filter stage) in all cases, despite the fact that a flow rate of 60L/min is specified for testing powders. 60L/min and 90L/ min modified versions of the ACI designed to, among other things, restore the full cut-off diameter range of the impactor at higher flow rates, now form part of the general chapter (24). However, these modified versions of the ACI, although in use for some time now, post-date the equipment available when the initial development of these RLDs was undertaken. With regard to test conditions, the total air volumes specified in the inhalation powder monographs are: 2L for DDU testing, a figure that is widely accepted as broadly reflecting the lung capacity of a typical COPD/asthma patient 3L for APSD measurement, a figure most likely to have been specified as a compromise, to achieve adequate volume changes in the ACI Mark Copley is the Sales Director at Copley Scientific Ltd. Prior to this, he was Technical Sales Manager and Product Specialist for the company s range of inhaler testing equipment. He also provides application support and consultancy, runs focused training workshops for the inhaled drug testing sector, and sits on the editorial advisory panel of Inhalation Magazine. An invited member of the European Pharmaceutical Aerosol Group impactor sub-team, Mark has also made recommendations to the Inhalanda working group, leading to subsequent revisions to Ph Eur and USP monographs. He holds a Masters degree in Aerospace Engineering from the University of Bath. Email: sales@copleyscientific.co.uk The need for accurately timed flow control, in order to obtain the above volumes, can be achieved using a fast-acting solenoid valve, as specified in the general chapter set-up for DPI testing, which is also designed to ensure a constant flow rate through the cascade impactor during testing. A Crucial Role Product-specific guidance can be extremely helpful in defining in vitro test strategies that will robustly demonstrate BE and satisfy regulatory requirements. Product-specific monographs also have a role to play in ensuring the consistent quality of widely used drugs as they transition into generic products. Although some of these call for the use of test methods that differ from those in the general chapters, the equipment required is now readily and commercially available. Its use may be helpful in generic development and in ensuring an ongoing supply of safe, efficacious and inexpensive drug products. References 1. FDA Guidance for Industry, Bioequivalence recommendations for specific products. Visit: www. fda.gov/downloads/drugs/ GuidanceComplianceRegula toryinformation/guidances/ ucm072872.pdf 2. FDA Guidance, Compliance and Regulatory Information, Productspecific recommendations for generic drug development. Visit: www.fda.gov/drugs/ guidancecomplianceregula toryinformation/guidances/ ucm075207.htm 3. USP Fact Sheet, USP Standards: Monographs. Visit: www.usp. org/sites/default/files/usp_pdf/ EN/regulator/monograph_ backgrounder_dec_2011.pdf 4. Nisen M, The bestselling prescription drugs in the world last year. Visit: www. qz.com/349929/best-sellingdrugs-in-the-world 5. World s pharma innovation base moving to India, says IBEF, Manufacturing Chemist, CPPR Industry/University Cooperative, October 2013 6. FDA Guidance for Industry, 180-day generic drug exclusivity under the Hatch- Waxman Amendments to the Federal Food, Drug and Cosmetic Act. Visit: www.fda. gov/downloads/drugs/.../ guidances/ucm079342.pdf 7. Munroe T and Chatterjee S, Analysis: Indian pharma draws more FDA scrutiny as U.S. imports rise. Visit: www.reuters. com/article/2013/09/12/usindia-drugs-analysisidusbre98b17c20130912 8. FDA guidance for industry metered dose inhaler and dry powder inhaler drug products, Chemistry, manufacturing and control documentation, November 1998. Visit: www.fda. gov/downloads/drugs/.../ guidances/ucm070573.pdf 9. USP general chapter 601, Aerosols, nasal sprays, metered dose inhalers and dry powder inhalers 10. USP general chapter 1601, Products for nebulization characterization tests 11. Mitchell JP and Nagel MW, Cascade impactors for the size characterization of aerosols from medicinal inhalers: Their uses and limitations, Journal of Aerosol Medicine 16(4): pp341-377, 2003 12. Van Oort M and Downey B, Cascade impaction of MDIs and DPIs: Induction port, induction cone and 26 Innovations in Pharmaceutical Technology Issue 55

pre-separator lid designs recommended for inclusion in the general test chapter Aerosols USP 601, Stimuli to the revision process, Pharmacopoeial 22(2): pp2,204-2,210, 1994 13. Collins S, Determination of emitted dose from dry powder inhalers: An alternative to the USP unit spray sampling apparatus, Drug Delivery to the Lungs 8: pp116-120, 1997 14. Preparations for inhalation of the British Pharmacopoeia, Content of active ingredient delivered by actuation of the valve 15. Draft Guidance on albuterol sulfate, June 2013. Visit: www. fda.gov/downloads/drugs/ guidancecomplianceregulatory Information/Guidances/ucm 346985.pdf 16. Draft guidance on budesonide, recommended September 2012. Visit: www. fda.gov/downloads/drugs/.../ Guidances/UCM319977.pdf 17. Draft guidance on fluticasone propionate; salmeterol xinafoate. Visit: www.fda. gov/downloads/drugs/ GuidanceComplianceRegula toryinformation/guidances/ UCM367643.pdf 18. Draft Guidance on ipratropium bromide. Visit: www.fda.gov/ downloads/drugs/ GuidanceCompliance RegulatoryInformation/ Guidances/ucm436831.pdf 19. New introduction: Fluticasone propionate inhalation powder, Second supplement to USP 36-NF31, December 2013 20. New introduction: Fluticasone propionate inhalation aerosol, Second supplement to USP 36-NF31, December 2013 21. New introduction: Salmeterol inhalation powder, Second supplement to USP37-NF33, December 2014 22. USP Pharm Forum 41(1) fluticasone propionate and salmeterol inhalation aerosol, February 2015 23. USP Pharm Forum 41(1) fluticasone propionate and salmeterol inhalation powder, February 2015 24. Chapter 601, Inhalation and nasal drug products: Aerosols, sprays, and powders Performance quality tests, first supplement to USP 37-NF32, August 2014