Blood Pressure Monitor PASESA

Similar documents
Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( The story so far.

a central pulse located at the apex of the heart Apical pulse Apical-radial pulse a complete absence of respirations Apnea

TODAY S TOPIC Blood Pressure & Pulse Wave Measurement Combined in One Procedure Re-classification of Risk Patients

Non-Invasive Method of Blood Pressure Measurement Validated in a Mathematical Model

Abstract. (Left Mouse-click to begin and move to next slide.)

Medical Review Approaches to the Diagnosis of Liver Fibrosis

A GUIDE TO OUR NIBP TECHNOLOGY

Which method is better to measure arterial stiffness; augmentation index, pulse wave velocity, carotid distensibility? 전북의대내과 김원호

AN INTRODUCTION TO DOPPLER. Sarah Gardner, Clinical lead, Tissue viability service. Oxford Health NHS Foundation Trust.

Change in Elasticity Caused by Flow-Mediated Dilation Measured Only for Intima Media Region of Brachial Artery

Impedance Cardiography (ICG) Method, Technology and Validity

Investigation and evaluation of arterial pulses, blood pressure, and jugular venous pressure

5.2. MEASUREMENT OF BLOOD PRESSURE

Onpulse TM technology and the geko TM device: The development of a novel system for the prevention of venous thromboembolism

Arterial stiffness index: A new evaluation for arterial stiffness in elderly patients with essential hypertension

Blood Pressure Estimation Using Photoplethysmography (PPG)

Monitoring Cardiac Health Using a Laser Doppler Approach to Measure Pulse Wave Velocity

Device Equivalence Evaluation Form

NONINVASIVE CONTINUOUS BLOOD PRESSURE DETERMINATION. D. Barschdorff*, M. Erig*, E. Trowitzsch**

Clinical application of Arterial stiffness. pulse wave analysis pulse wave velocity

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time

BP-600 Noninvasive Blood Pressure Sensor

Cardiovascular Diseases Detecting via Pulse Analysis

1 Non-invasive measurement of arterial pressure

CVS Hemodynamics. Change in blood pressure:

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

Name of Policy: Computerized Pulse Waveform Analysis

AGENDA for 04/04/14 AGENDA: HOMEWORK: Due Tues, Online Quiz: OBJECTIVES:

!"#$ Blood Pressure Monitor. Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33

M1 Classic. Digital Blood Pressure Monitor. Instruction manual page 1 SYS. mmhg DIA. mmhg. PULSE/min

Vascular Testing. and. You

Impedance Cardiography (ICG) Application of ICG for Hypertension Management

PHONOCARDIOGRAPHY (PCG)

Device Equivalence Evaluation Form

New indices of arterial stiffness measured with an upper-arm oscillometric device in active versus inactive women

HUMAN ANATOMY AND PHYSIOLOGY

A Simulation for Estimation of the Blood Pressure using Arterial Pressure-volume Model

Association between novel arterial stiffness indices and risk factors of cardiovascular disease

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

JAMES R. KNIGHT

EVALUATION OF NONINVASIVE PULSE TRANSIT TIME METHODOLOGIES FOR DIAGNOSIS OF HYPERTENSION DANIEL JOHN BADGER. A thesis submitted to the

Physiology lecture 15 Hemodynamic

Special Lecture 10/28/2012

Biomedical Instrumentation E. Blood Pressure

CVS Hemodynamics. Faisal I. Mohammed, MD,PhD.

Blood Pressure Determination Using Analysis of Biosignals

Blood Flow Measurement Devices Market - Global Industry Analysis, Size, Share, Growth, Trends and Forecast, Single User License: US $ 4595

DEVELOPMENT OF NON-INVASIVE STEERING-TYPE BLOOD PRESSURE SENSOR FOR DRIVER STATE DETECTION. Received December 2017; revised April 2018

Nomogram of the Relation of Brachial-Ankle Pulse Wave Velocity with Blood Pressure

MX3 Plus English. Introduction. Table of contents. 1 How to obtain meaningful blood pressure readings

All WALES LYMPHOEDEMA GUIDANCE:

2. Measure a subject's blood pressure and heart rate both at rest and during exercise.

Lectures on Medical Biophysics Department of Biophysics, Medical Faculty, Masaryk University in Brno. Biophysics of cardiovascular system

Simulation of the Blood Pressure Estimation using the Artery Compliance Model and Pulsation Waveform Model

SYNCHRONIZED MEASUREMENTS OF MAXIMUM BLOOD FLOW VELOCITIES IN CAROTID, BRACHIAL AND FEMORAL ARTERIES, AND ECG IN HUMAN POSTURE CHANGES

Device Equivalence Evaluation Form

LAB: Blood Pressure Measurable Indicator of the Health of the Circulatory System!

Carotid and radial pulse feature analysis with EMFi sensor

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

APPLICATION OF PHYSICAL METHODS FOR DETERMINATION OF FUNCTIONAL PARAMETERS OF ARTERIES IN RHEUMATIC PATIENTS

Declaration of Equivalence Form

Comparative Study of Arterial Compliance Using Invasive and Noninvasive Blood Pressure Waveform

AUTOMATIC WRIST Blood PReSSuRe MonIToR InSTRucTIon Manual

Non- invasive vascular testing. Pros and Cons of ABIs and Alternative Physiologic Assessments

Cardiac Cycle MCQ. Professor of Cardiovascular Physiology. Cairo University 2007

Keun-Ho Kim and Sang-Suk Lee* Department of Oriental Biomedical Engineering, Sangji University, Wonju , Korea

BIOL 219 Spring Chapters 14&15 Cardiovascular System

Introduction of diverse devices to measure arterial stiffness

The Circulatory System. Lesson Overview. Lesson Overview The Circulatory System

Special Lecture 11/08/2013. Hypertension Dr. HN Mayrovitz

Wrist Energy Fuzzy Assist Cancer Engine WE-FACE

Blood Pressure Monitors Nissei

Duplex Ultrasound. A Detailed Look at Your Blood Vessels

Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination

Modeling of a Ring for Blood Pressure Measurement in COMSOL Multiphysics for Medical Applications

BP210 BP250. Automatic Blood Pressure Monitor. Medical Diagnostic Device

Device Equivalence Evaluation Form

EFFECTS OF MECHANICAL PUMPING ON THE ARTERIAL PULSE WAVE VELOCITY : PERIPHERAL ARTERY AND MICRO-VESSELS

PULSE WAVE VARIABILITY WITHIN TWO SHORT-TERM MEASUREMENTS. David Korpas, Jan Halek

CHAPTER 4 ESTIMATION OF BLOOD PRESSURE USING PULSE TRANSIT TIME

Suzuka medical university of Science and technology, 2 Ehime University medical department,

Choosing Mindray SpO2

WHAT IS AORTIC PULSE WAVE VELOCITY?

iworx Sample Lab Experiment HC-5: Body Position, Exercise, and Cardiac Output

Neurostyle. Medical Innovation for Better Life

Optimising your Doppler settings for an accurate PI. Alison McGuinness Mid Yorks Hospitals

What effects will proximal or distal disease have on a waveform?

Cut-Off Value of the Ankle-Brachial Pressure Index at Which the Accuracy of Brachial-Ankle Pulse Wave Velocity Measurement is Diminished

The Conduit Artery Functional Endpoint (CAFE) study in ASCOT

IABP Timing & Fidelity. Pocket Reference Guide

Clinical Evaluation of an Oscillometric NIBP Technology During Hemodialysis According to the British Hypertension Society Protocol

Chapter 15: Measuring Height, Weight, and Vital Signs. Copyright 2012 Wolters Kluwer Health Lippincott Williams & Wilkins

Biology Unit 3 The Human Heart P

Arterial Age and Shift Work

Influence of 50-Hz electric and magnetic fields on human blood pressure

High Blood Pressure Blood Pressure Monitoring at Home -- F...

Blood Pressure Passport Simply fill in

Aerobic and Anaerobic Respiration Revision 2

Transcription:

Blood Pressure Monitor PASESA new oscillometric device with AVI&API PASESA Prevent ArterioSclerosis and Enjoy Successful Aging

PASESA, digital blood pressure monitor for medical use Sit still for two minutes and you can check the condition (elasticity) of your blood vessels, while measuring your blood pressure at the same time. We developed this Japan s original technology with the collaboration of National Institute of Advanced Industrial Science and Technology and RIKEN, the Institute of Physical and Chemical Research. PASESA is useful and effective in preventing arteriosclerosis. PASESA has obtained marketing approval required by Japanese Pharmaceutical Affairs Law, and is now used mainly in university hospitals.

Principle of AVI (Arterial Velocity pulse Index) Principle: AVI shows the characteristics of the pulse waveform when the cuff pressure is higher than maximum blood pressure. RIKEN recently found that the pulse waves in pressure area which has usually been ignored represent the stiffness and the nature of the central arteries near the heart. Due to aging and arteriosclerosis, the waveform changes (from left to right in below patterns). The upper waveforms are those of cuff pressure pulse wave, and the lower are the differentiated waveforms (differentiated pulse wave). Aging, arteriosclerosis and increased peripheral vessel resistance increase the reflected wave, which in turn increase telesystolic waveforms (P2) and result in a sharp fall of waveform. Since the waveform is unaffected by the reflected wave at the beginning (P1), only Vr of differentiated pulse wave amplitude increases. Thus the value of the characteristics of the pulse waveform (Vr/Vf) becomes the index that changes according to the size of the reflected wave. Definition: Calculate the ratio of the speed changes at upper arm artery during systolic period (Vf) and diastolic period (Vr) (Vr/Vf). AVI = 20 x (Vr/Vf) Characteristics: The value of AVI increases by factors which increase the reflected wave (aging, arteriosclerosis and increased peripheral vessel resistance) P1 P2 International Journal of Cardiology Available online 17 March 2015 The accuracy of central blood pressure waveform by novel mathematical transformation of noninvasive measurement

Principle of API (Arterial Pressure volume Index) Principle: The more elastic the arteries, the more drastic the arterial volume changes when the cuff pressure decreases. The blood vessel stiffness is converted into numerical values using the gradient of the curve as index. Definition: It calculates the relation between cuff pressure and arterial volume from cuff pressure data, and approximate it to an arctangent function (A*arctan(B*X+C)+D). API=1/B Characteristics: Reportedly, API represents the condition of peripheral (upper arm) artery, and the value of API increases by aging and arteriosclerosis. Note the Note the expansion of upper arm artery

Onset of arteriosclerosis has been rapidly increasing in areas affected by the Great East Japan Earthquake PASESA has been useful in physical examinations for detecting economy-class syndrome (deep vein thrombosis) 63rd JAMT Congress 2014 Luncheon Seminar May 18 2014 Arteriosclerosis among victims of the Great East Japan Earthquake: a possible new method for detecting arteriosclerotic disease by Kazuhiko Hanzawa, MD, PhD, Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences According to the measurement results by PASESA, people living in temporary housings where they have easier access to medical facilities are in better physical condition.

PASESA Printed report of detailed measurement result (A4) For doctors For examinees Pulse wave amplitude graph Velocity pulse wave graph Pulse wave graph (Pulse wave chart) Blood vessel index reference value graph Blood pressure Pulse AVI / API History graph Categories of blood pressure

http://www.riken.jp/en/outreach/transfer/products/