Introduction. Study Objective. Methodology. Results. Data Analysis. Interpretation

Similar documents
Introduction. Study Objective. Methodology. Results. Data Analysis. Interpretation

Chemistry Reference Ranges and Critical Values

Chemistry Reference Ranges and Critical Values

Evaluation of VACUETTE CAT Serum Fast Separator Blood Collection Tube for Routine Chemistry Analytes in Comparison to VACUTAINER RST Tube

1. PROTOCOL. Comparison Study Summary. Tuality Healthcare 324 SE 9 th Ave. Suite E Hillsboro, OR July 30, 2014

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

Comparison of VACUETTE Heparin Gel Tubes for Common Chemistry Analytes

COBAS, ACCU-CHECK INFORM, MODULAR and LIFE NEEDS ANSWERS are trademarks of Roche Roche

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information

Total Cost of Ownership (TCO): An evidence-based approach to compare laboratory equipment

1 PROTOCOL. Comparison Study Summary. Springs Memorial Hospital. Springs Memorial Hospital 800 W. Meeting St. Lancaster, SC (803)

BIOO RESEARCH PRODUCTS. Aspartate Transaminase (AST) Color Endpoint Assay Kit Manual Catalog #:

Pitfalls in Linear Regression Analysis

1.4 - Linear Regression and MS Excel

M.D.IPA, M.D.IPA Preferred, Optimum Choice and Optimum Choice Preferred STAT Laboratory List Revised Jan. 5, 2017

Aspartate Transaminase (AST) Color Endpoint Assay Kit Manual Catalog #:

Method Comparison Report Semi-Annual 1/5/2018

Coping with Analytical Interferences

1 PROTOCOL. Comparison Study Summary

ENROLLMENT CONFIRMATION

Evaluation of Cheongmeak DCS TM Reagents for Chemistry Analyzers

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with:

TABLE OF CONTENTS GENERAL INFORMATION... 1

Simple Linear Regression

Specimen Collection Requirements

Simple Linear Regression the model, estimation and testing

The analytical phase

SCATTER PLOTS AND TREND LINES

Decimal degree. 1:1,500,000 Area of collection

Comparison of Three Whole Blood Creatinine Methods for Estimation of Glomerular Filtration Rate Before Radiographic Contrast Administration

Technical guide on efficient sample preparation for clinical diagnosis

Clinical Evaluation for. Embrace No Code Blood Glucose Monitoring System

Evaluation Report of the Pneumatic Tube Transport System (PEVCO) connecting Dialysis Hospital to. Mubarak Hospital. Dr.

More to Life. Where research becomes the basis of discovering newer ways of alleviating human suffering and empowering an individual with good health.

CRITERIA FOR USE. A GRAPHICAL EXPLANATION OF BI-VARIATE (2 VARIABLE) REGRESSION ANALYSISSys

Stability of VACUETTE Lithium Heparin Separator tubes with modified centrifugation conditions

Chapter 3 CORRELATION AND REGRESSION

IDEXX Catalyst One Chemistry Analyzer for In-house Measurement of Total Thyroxine (TT 4 ) Concentration in Serum from Dogs and Cats

USING THE ACCESS AMH ASSAY IN YOUR LABORATORY

BIOCHEMICAL REPORT. Parameters Unit Finding Normal Value. Lipase U/L Amylase U/L

Inspector's Accreditation Unit Activity Menu

IODINE AFFINITY. 3. Extraction Shells: Paper, 80 x 22 mm (Note 1)

Evaluation of VACUETTE SECONDARY Tubes

Evaluation of Accuracy and User Performance of the TRUE METRIX Self-Monitoring Blood Glucose System

Section 3 Correlation and Regression - Teachers Notes

Testing Kits. Pregnancy Test Kits. Hepatitis Test Kits. HIV - 1 & 2 Test Kits

Setting of quality standards

REGRESSION MODELLING IN PREDICTING MILK PRODUCTION DEPENDING ON DAIRY BOVINE LIVESTOCK

1. The figure below shows the lengths in centimetres of fish found in the net of a small trawler.

Specimen Collection Requirements

Clinical Study Thrombin-Accelerated Quick Clotting Serum Tubes: An Evaluation with 22 Common Biochemical Analytes

NORTH SOUTH UNIVERSITY TUTORIAL 2

The Adiponectin Turbidimetric Immunoassay Reagent Kit

BIOO LIFE SCIENCE PRODUCTS

CLINICAL CHEMISTRY REAGENTS. Product Profile

Monitoring Hepatitis C

ACCESS hstni SCIENTIFIC LITERATURE

Clinical Accuracy and User Performance of the TRUE METRIX AIR Blood Glucose Monitoring System

To be used for the ease of test requisitioning on select patients only; all components may be ordered separately

Speed Accuracy Trade-Off

SCIEX Vitamin D 200M Assay for the Topaz System

Glucose Analytical Comparability Evaluation of the YSI 2300 STAT Plus and YSI 2900D Biochemistry Analyzers

Biochemical investigations in clinical medicine

CERTIFICATE OF ACCREDITATION

PLACE LABEL HERE. Radiation Therapy Oncology Group Phase II Nasopharyngeal Cancer Follow-Up Form

DEPARTMENT: Regulatory Compliance Support

Evaluation of Accuracy and User Performance of the TRUE METRIX Blood Glucose Monitoring System

COBAS INTEGRA / cobas c C.f.a.s.

Alaska Native Medical Center Anchorage, AK

RITUXIMAB RHEUMATOLOGY VASCULITIS

Conditional Distributions and the Bivariate Normal Distribution. James H. Steiger

TRACEABILITY and UNCERTAINTY 7

NORMAL LABORATORY VALUES FOR CHILDREN

Multiple studies are available concerning the use of

PRELIMINARY RESULTS: SERUM CHEMISTRY VALUES BEFORE AND AFTER THE INTRAVAGINAL ADMINISTRATION OF 5% NONOXYNOL-9 CREAM

General Chemistry Scheme Guide

EXAM COVER SHEET. Course Code: CLS 432. Course Description: Clinical Biochemistry. Final Exam. Duration: 2 hour. 1st semester 1432/1433.

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

In Vitro Diagnostic Glucose Test System

(a) y = 1.0x + 0.0; r = ; N = 60 (b) y = 1.0x + 0.0; r = ; N = Lot 1, Li-heparin whole blood, HbA1c (%)

Ph D. Synopsis 4. WORK PLAN AND METHODOLOGY

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

Statistics for Psychology

Advanced Hematology Five-Part Differential. Simple Operation

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

1. Calibra - H - Store at 2-8 ºC.

The NGAL Turbidimetric Immunoassay Reagent Kit

GENERAL INFORMATION CLINICAL LABORATORY PHONE DIRECTORY

Evaluation and comparison of automated analysers on hepatic enzymes

FreeStyle Lite A Blood Glucose Meter That Requires No Coding

Biology 345: Biometry Fall 2005 SONOMA STATE UNIVERSITY Lab Exercise 5 Residuals and multiple regression Introduction

Quality Initiative In Pathology. Harmonisation of Laboratory Testing

HZAU MULTIVARIATE HOMEWORK #2 MULTIPLE AND STEPWISE LINEAR REGRESSION

QUALITROL 2H Insert. 01 Inglês - Ref.: 72. Ref.:72. Precautions and warnings

CERTIFICATE OF ACCREDITATION

VITROS MicroSlide Assay Summary

JOB AID CRITICAL VALUES AND TESTS W/O MICRO CRITICAL TESTS. Always call results for the following test(s):

Section 3.2 Least-Squares Regression

BASIC METABOLIC PANEL

Transcription:

WHITE PAPER COMPARISON STUDY BETWEEN THE HETTICH EBA 200S (HP) BLOOD TUBE PACKAGE 8 (FORMALLY HELMER QUICKSPIN PLUS) AND A TRADITIONAL 3 LITER CENTRIFUGE IN BLOOD CHEMISTRY DETERMINATIONS

Introduction The Hettich EBA 200S (HP) Blood Tube Package 8 is a small high-speed clinical bench top centrifuge developed for stat sample applications. The fixed angle rotor holds up to 8 tubes and accommodates tube capacities from 2.7mL (with included inserts) to 15mL. The EBA 200S Blood Tube Package - 8 has spin times programmable in increments of one minute and speeds up to 8000 RPM programmable in increments of 100. Study Objective This study examined and compared chemistry test results for 17 analytes in samples centrifuged in the EBA 200S Blood Tube Package - 8 and a traditional 3L centrifuge. Methodology Two SST tubes (BD, 13x100mm) were taken from 20 individuals and centrifuged in the EBA 200S Blood Tube Package - 8 at 7500 RPM for two minutes and in the traditional 3 liter centrifuge at 3500 RPM for ten minutes. Post centrifugation, the serum was tested for the following: glucose, BUN, creatine, albumin, total protein, calcium, total bilirubin, CPK, CKMB, troponin, alkaline phosphatase, SGPT, SGOT, amylase, Na, Cl, and CO2. The Roche Integra 700 analyzer was used to test the serum. Results Table 1 shows the statistical analysis. Table 2 displays the percentage difference between each sample processed in the EBA 200S Blood Tube Package - 8 and each sample processed in the traditional 3 liter centrifuge. Table 3 shows original data for chemistry results. The group of scatter plot charts collectively labeled Chart 1 shows the plot points defined by the analyte result for the EBA 200S Blood Tube Package - 8 on the x-axis and the result for the traditional 3 liter centrifuge on the y-axis. Data Analysis Linear regression was used to analyze the results from each centrifuge. Correlation coefficients range from 0.85 to 1.00. Slopes range from 0.85 to 1.20, and y-intercepts range from -22.62 to 10.52. The average percentage differences for the analytes with number of samples >10 range from 0.85% (Na) to 28.76% (troponin). Analytes with more than ten samples account for 15 of the 17 analytes tested. Interpretation SST tubes centrifuged in the EBA 200S Blood Tube Package - 8 for just two minutes consistently achieved separation of serum and cells and produced samples suitable for blood chemistry testing. Additionally, the general 45 degree linear trend demonstrated in Chart 1 indicates a near one-to-one relationship between the values for the analyte test results for the EBA 200S Blood Tube Package - 8 and the traditional 3 liter centrifuge.

than eight percent. Troponin has 13 sample values accounted for, and the numerical values are generally small numbers with a small range for normality (0.00-0.03). For the purposes of this study, these numbers were only available to the second decimal place, meaning that very small variances, even well within the normal range, reflect large differences in terms of percentage. Analytes with significantly small sample populations for the purposes of this test include CPK, with only five samples available for testing, and amylase, with only seven samples available for testing. Conclusion Results indicate that the EBA 200S Blood Tube Package - 8 is capable of preparing samples suitable for blood chemistry tests in only two minutes, and that it provides comparable clinical efficacy to the traditional 3 liter centrifuge that was tested in the study. The EBA 200S Blood Tube Package - 8 provides faster turnaround times (2 minutes versus 10 minutes) without sacrificing the quality and accuracy of the test results.

Table 1: Statistical Analysis Table 2: Percentage Difference in Result Values by Sample and Analyte The chart above shows the percentage difference between the value for the result of the analyte tested in the traditional 3 liter centrifuge versus the value for the same analyte tested in the EBA 200S Blood Tube Package - 8. For example, it could be correctly stated that for glucose sample number 10, there is a 0.81% difference between the result achieved in the traditional 3 liter centrifuge and the result achieved in the EBA 200S Blood Tube Package - 8. A designation of NA indicates that the sample was not tested for that analyte.

Table 3a: Original Data Table 3b: Original Data

Table 3c: Original Data Table 3d: Original Data

Chart 1

www.helmerinc.com 2008 Helmer Inc. All rights reserved. All trademarks are the property of Helmer Scientific. S2R009/B WHITE PAPER S2F010 2-16