Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ

Similar documents
Bone Bangalore

Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

Product Information. *smith&nephew POLARCUP Dual Mobility System

DISLOCATION OF THE TOTAL HIP Arthroplasty

CLINICAL PAPER / ORTHOPEDIC

TOTAL HIP REPLACEMENT:

Stability without compromise. Epsilon Durasul Constrained Insert

76 F: Plays tennis, lives independently, told she has weak bone

Case Report Anterior Subluxation after Total Hip Replacement Confirmed by Radiographs: Report of Two Cases

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Dissociation of Polyethylene Liner of the Dual Mobility Acetabular Component after Closed Reduction of Dislocation: A Case Report

Dual Mobility Cups. Kris Govaers, MD, PhD Dendermonde Belgium

The Leader in Orthopaedic Innovation

Optimum implant geometry

Preventing complications in THR

Influences of head/neck ratio and femoral antetorsion on the safe-zone of operative acetabular orientations in total hip arthroplasty

ACETABULAR CUP SURGICAL TECHNIQUE

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Dual Mobility System Evaluation surgical technique

*smith&nephew POLARCUP Dual Mobility System. Product Information

Dual Mobility System Surgical technique

Socket wall addition device in the treatment of recurrent hip prosthesis dislocation

Navigation for total hip arthroplasty

Presented by : Frank Filice (PT) London Health Sciences Centre

Chronic Lymphedema of the Lower Limb: A Rare Cause of Dislocation of Total Hip Arthroplasty

Ceramic Femoral Heads and Acetabular Cup Liners

Manza Cup HA SURGICAL TECHNIQUE.

Trabecular Metal Acetabular Revision System Cemented Constrained Liner

Constrained acetabular liners in hip revision surgery. A low-cost solution for senile patients

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Biomechanical concepts of total shoulder replacement. «Shoulder Course» Day 1. Richard W. Nyffeler Orthopädie Sonnenhof Bern. 11. Sept.

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

CERAMIC-ON-METAL. References: Cat No: version 2

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Metha Short Hip Stem System

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Duraloc CONSTRAINED LINER

Design Rationale. ECHELON Primary Hip System

Understanding Hip Implant Options

HIP SYSTEM SURGICAL TECHNIQUE

Measuring the Impact of Femoral Head Size on Dislocation Rates Following Total Hip Arthroplasty

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Optimum implant geometry

Reaching new heights. Comprehensive. Efficient. Simple.

Longevity Offset and Oblique Liners. Surgical Technique

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe

Preoperative Planning. The primary objectives of preoperative planning are to:

Total Hip Arthroplasty Performed Using Conventional and Computer-Assisted, Tissue- Preserving Techniques 6

HipNav: Pre-operative Planning and Intra-operative Navigational Guidance for Acetabular Implant Placement in Total Hip Replacement Surgery

Disclosure. Direct Anterior THA via Extension Table. History 11/3/2015

PLR. Proximal Loading Revision Hip System

The Spatial Location of Impingement in Total Hip Arthroplasty

Recently, the new generation of metal-on-metal total hip resurfacing. arthroplasty is well known for preserving the proximal femoral bone stock,

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

In Vivo Dissociation Of A Dual Articulation Bearing In Revision THA -Case Report-

CONGENITAL HIP DISEASE IN YOUNG ADULTS CLASSIFICATION AND TREATMENT WITH THA. Th. KARACHALIOS, MD, DSc PROF IN ORTHOPAEDICS

BIOTRIBOLOGICAL AND MECHANICAL ANALYSIS OF TOTAL HIP ARTHROPLASTIY FAILURE: How to break the code

Vasu Pai D orth, MS, National Board [orth],mch, FRACS, FICMR Total Hip Arthroplasty

Restoration Anatomic Acetabular System Surgical Technique

Progeny Hip Stem. Surgical Protocol and Product Specifications

CASE 56 Hip Pain. ? Diagnosis

Your Pre-operative Guide

RECOVERY. P r o t r u s i o

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

DIRECT SUPERIOR HIP APPROACH IN TOTAL HIP ARTHROPLASTY. Anil Thomas, MD Adult Reconstruction Peachtree Orthopedics Atlanta, GA

Totally Hip Preservation to Revision. Gothenburg, Sweden 29 March - 1 April 2017 WEDNESDAY 29 MARCH. Arrivals THURSDAY 30 MARCH

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006

PINNACLE REVISION CUP SYSTEM

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

An Investigation into the Dynamic Loading of Ceramic-on-Ceramic Total Hip Replacements and its Relevance to Squeaking

R. Bouchet, N. Mercier, D. Saragaglia ORIGINAL ARTICLE. KEYWORDS Dislocation; Total hip prosthesis; Dual mobility cup; Posterior approach

Case Report Inflammatory Pseudotumor Complicated by Recurrent Dislocations after Revision Total Hip Arthroplasty

Proximal Modular Stem Design Dual Press With a Dual-Tapered K2 Trapezoid Stems

Cementless Tapered Femoral Stem Surgical technique

Cementless femoral stem type SF

R3think your options. For US distribution only.

TaperFill. Surgical Technique

Early complications after revision total hip arthroplasty with cemented dual-mobility socket and reinforcement ring

Bi-Polar 22.2mm & 28mm System - Operative technique

Total Hip Replacement Surgery

EFORT Instructional Course

Exeter. Technical Guide

Ovation Hip System. Surgical Technique

Optimum implant geometry

Finite Element Study of Acetabular Cup Contact Region for Total Hip Replacement (THR)

FMP Surgical Technique

A Proven Concept. Alloclassic Zweymüller Stem

PMMA Spacer. X-ray Marker

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

The role of the transverse acetabular ligament in total hip arthroplasty

Metasul LDH Large Diameter Head

Informed Consent for HRA

Optimizing function Maximizing survivorship Accelerating recovery

Cementless Tapered Femoral Stem Surgical technique

Hip dislocation after total hip arthroplasty can be classified

Anterior Approach. Skills Stations

Transcription:

Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ Department of Orthopedics and Traumatology Medical University of Silesia Head of Department: prof. dr hab. n med. Damian Kusz

Can it be avoided?

Dislocation after hip replacement is a serious complication (reoperation is often required)

Risk factors: elderly after femoral neck fx neuromuscular disorders (low muscle tone and motor coordination) noncompliant patients (low chair, leg crossing) obesity Dislocation after hip replacement surgical errors; aiming for correction of leg length discrepancy, revision surgeries, improper cup or stem positioning women Werner BC I wsp. Instability after total hip arthroplasty. WJO, 2012; 18(3): 122-130 Nevelos J I wsp. What Factors Affect Posterior Dislocation Distance in THA? Clin Orthop Relat Res (2013) 471: 519 526

Causes of hip instability in obese (BMI >30) THA patients Soft tissue impingement during walking and sitting is relevant in morbidly obese Biomechanics of failure modalities in total hip arthroplasty, Elkins JM, University of Iowa, 2013

Dislocation after hip replacement High risk group it is right to maintain higher jump-distance Jump-distance depends on: level of anteversion and inclination of the cup cup and neck relation head diameter and its cover presence of antiluxation rim of the cup Craig J. Delia Valle: Causes of Hip Instability: An Algorithmic Approach to Treatment. Current Concepts Joint Replacement, Orlando, Winter 2015, 85-86

Jump distance Nevelos J I wsp. What Factors Affect Posterior Dislocation Distance in THA? Clin Orthop Relat Res (2013) 471: 519 526

Jump distance Jump distance: is lowered by cup inclination (0,25 mm per 1 0 with 32 mm head diameter) is increased by cup anteversion (0,05 mm per 1 0 ) is increased by head diameter (0,4 mm per 1 mm of head diameter when inclination is 45 0 ) Nevelos J I wsp. What Factors Affect Posterior Dislocation Distance in THA? Clin Orthop Relat Res (2013) 471: 519 526

Elhadi Sariali E i wsp. Mathematical evaluation of jumping distance in total hip arthroplasty. Influence of abduction angle, femoral head offset, and head diameter. Acta Orthopaedica. 2009; 80 (3): 277-282 ~ 50% of dislocations is associated with cup position Murphy SB. Acetabular Cup Placement. CCJR, Winter 2015; Orlando: 75

Beverland DE i wsp. Bone Joint J, 2016; 98B Supp A: 37-43 Main cause of higher cup inclination error during patient positioning (internal rotation and adduction)

Prevention of disclocation after THA Increasing jump-distance: dual mobility cup anatomical head with large diameter (anatomical) Constrained acetabular component

Prevention of disclocation after THA Dual mobility cup provide highest jump distance, which is a result of larger head diameter Disadvantages: van Heumen M I wsp: Dual mobility acetabular component in revision total hip arthroplasty for persistent dislocation. J Orthopacd Traumatol (2015) 16:15-20 Increased polyethylene wear (wearing on the metal cup increases risk of aseptic loosening) Potential iliopsoas conflict Inability to perform close reduction after dislocation Lachiewicz PF: The Dual Mobility Cup: The French Connection. Current Concepts Joint Replacement, Orlando, Winter 2015, 91

Prevention of disclocation after THA Anatomical heads with large diameter: better mobility and jump-distance thin both cup and PE insert (resistant to wear with ceramic or ceramic coated metal head) Disadvantages: it is possible to deform the cup during implantation faster wear Lombardi AV: Large Diameter Heads: Problem Solved or New Ones Created? Current Concepts Joint Replacement, Orlando, Winter 2015, 89-90

Prevention of disclocation after THA Constrained cups are reserved for patients: with Alzheimer s, after revision procedures with damaged abductors after revision procedures because of dislocation, especially with improper positioning of the implants lowered muscle tone because of neurological illnesses or immobility Callagham JJ: Constrained Liners: Yesterday's Solution?. Current Concepts Joint Replacement, Orlando, Winter 2015, 87-88

Large head? Biomechanics of failure modalities in total hip arthroplasty, Elkins JM, University of Iowa, 2013

Revision algorithm Type 1: malposition of the acetabular component cup revision and larger head Type 2: malposition of the femoral component stem revision and larger head Type 3: abductor deficiency dual mobility or constrained cup Type 4: impingement removing the impingement and larger head Type 5: late wear replacement and larger head Type 6: unclear etiology dual mobility or constrained cup Delia Valle CJ: Causes of Hip Instability: An Algorithmic Approach to Treatment. Current Concepts Joint Replacement, Orlando, Winter 2015, 85-86

Patient D.Z., born 1935, BMI 36 Primary THA 2011 Dislocation 2011 Case 1

Acetabular breaking after dislocation Infection treated by implant removal

Surgery - 12-2012: antiprotrusion cage GAP II, RESTORATION stem Dislocation at home Surgery 02-2013: PE insert removal, AVANTAGE cup

Dislocation at home Surgery 03-2013: reimplantation of antiprotrusion cage GAP II 52 60 mm and antiluxation AVANTAGE cup 44 54 mm

Patient B. G., born 1947, BMI 44, primary THA 2013, traumatic dislocation 01-2016, and again 02-2016 Case 2

Patient L. K., born 1951, BMI 50, primary THA 1995, revision surgeries 2002, 2004, 2011, 2012, dislocation december 2013 Case 3

Larger head: Summary provides larger jump-distance, increases joint mobility and helps to restore leg length new type of cups with thinner cup and PE insert allow to implant large head (size close to anatomical) theoretically increasing head >36mm is not relevant, when inclination is steep

Most effective treatment of dislocation is prevention done by surgeon and patient Werner BC I wsp. Instability after total hip arthroplasty. WJO, 2012; 18(3): 122-130

Thank you for your attention