Impedance Cardiography (ICG) Method, Technology and Validity

Similar documents
Impedance Cardiography (ICG) Application of ICG for Hypertension Management

Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency

CARDIOVASCULAR MONITORING. Prof. Yasser Mostafa Kadah

Hemodynamic Monitoring and Circulatory Assist Devices

FUNDAMENTALS OF HEMODYNAMICS, VASOACTIVE DRUGS AND IABP IN THE FAILING HEART

Cardiac Output Monitoring - 6

QUIZ 1. Tuesday, March 2, 2004

Determination of left ventricular stroke volume from the arterial pressure wave

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow

Introduction. Invasive Hemodynamic Monitoring. Determinants of Cardiovascular Function. Cardiovascular System. Hemodynamic Monitoring

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Shock, Monitoring Invasive Vs. Non Invasive

The circulatory system

Chapter 9, Part 2. Cardiocirculatory Adjustments to Exercise

THE CARDIOVASCULAR SYSTEM

Introduction to Physiology (Course # 72336) 1. Adi Mizrahi Textbook Chapter 12

Radboud University Nijmegen Medical Centre Why measure cardiac output in critically ill children?

Cardiac Output MCQ. Professor of Cardiovascular Physiology. Cairo University 2007

Special Lecture 10/28/2012

Goal-directed vs Flow-guidedresponsive

Edwards FloTrac Sensor & Performance Assessments of the FloTrac Sensor and Vigileo Monitor

Cardiovascular Structure & Function

Hemodynamic monitoring beyond cardiac output

Cytoreductive Surgery and Hyperthermic Intraperitoneal Chemotherapy

Heart Pump and Cardiac Cycle. Faisal I. Mohammed, MD, PhD

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC

During exercise the heart rate is 190 bpm and the stroke volume is 115 ml/beat. What is the cardiac output?

escco, estimated Continuous Cardiac Output device DESEBBE OLIVIER SAUVEGARDE CLINIC, LYON, FRANCE

Relax and Learn At the Farm 2012

An Introduction to Electrical Cardiometry

BIOL 219 Spring Chapters 14&15 Cardiovascular System

Principles of Biomedical Systems & Devices. Lecture 8: Cardiovascular Dynamics Dr. Maria Tahamont

Calculations the Cardiac Cath Lab. Thank You to: Lynn Jones RN, RCIS, FSICP Jeff Davis RCIS, FSICP Wes Todd, RCIS CardioVillage.

Cardiovascular Physiology. Heart Physiology. Introduction. The heart. Electrophysiology of the heart

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

Mechanics of Cath Lab Support Devices

Invasive Cardiac Output Monitoring and Pulse Contour Analysis. Harshad B. Ranchod Paediatric Intensivist Chris Hani Baragwanath Hospital COPICON 2011

Cardiovascular Management of Septic Shock

BUSINESS. Articles? Grades Midterm Review session

TOPIC : Cardiogenic Shock

CVICU EXAM. Mrs. Jennings is a 71-year-old post-op CABG x5 with an IABP in her left femoral artery

Cath Lab Essentials: Basic Hemodynamics for the Cath Lab and ICU

PCV and PAOP Old habits die hard!

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

SymBioSys Exercise 2 Cardiac Function Revised and reformatted by C. S. Tritt, Ph.D. Last updated March 20, 2006

Useful Ectopics: Case Study. Effects of vasodilation and the diagnostic value of ectopic heartbeats

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004

Physiologic Based Management of Circulatory Shock Kuwait 2018

Mechanics of Cath Lab Support Devices

Weeks 1-3:Cardiovascular

Cardiovascular Physiology

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

Department of Intensive Care Medicine UNDERSTANDING CIRCULATORY FAILURE IN SEPSIS

*Generating blood pressure *Routing blood: separates. *Ensuring one-way blood. *Regulating blood supply *Changes in contraction

FloTrac Sensor and Edwards PreSep Central Venous Oximetry Catheter Case Presentations

Cardiac output and Venous Return. Faisal I. Mohammed, MD, PhD

Cardiac Cycle MCQ. Professor of Cardiovascular Physiology. Cairo University 2007

E/Ea is NOT an essential estimator of LV filling pressures

For more information about how to cite these materials visit

Blood pressure. Formation of the blood pressure: Blood pressure. Formation of the blood pressure 5/1/12

Index of subjects. effect on ventricular tachycardia 30 treatment with 101, 116 boosterpump 80 Brockenbrough phenomenon 55, 125

CONSIDERATIONS ABOUT THE LUMPED PARAMETER WINDKESSEL MODEL APPLICATIVITY IN THE CARDIOVASCULAR SYSTEM STRUCTURE

EVOLUCIÓN DE LA MONITORIZACIÓN CARDIOVASCULAR EN LA UCI

Admission of patient CVICU and hemodynamic monitoring

Blood Flow, Blood Pressure, Cardiac Output. Blood Vessels

Disclosures. Afterload on the PV loop. RV Afterload THE PULMONARY VASCULATURE AND ASSESSMENT OF THE RIGHT VENTRICLE

(D) (E) (F) 6. The extrasystolic beat would produce (A) increased pulse pressure because contractility. is increased. increased

BME 5742 Bio-Systems Modeling and Control. Lecture 41 Heart & Blood Circulation Heart Function Basics

Rhythm Disorders 2017 TazKai LLC and NRSNG.com

2.6 Cardiovascular Computer Simulation

Cardiac Output. Graphics are used with permission of: adam.com ( Benjamin Cummings Publishing Co (

Impedance Cardiography

Special Lecture 11/08/2013. Hypertension Dr. HN Mayrovitz

SUPPLEMENTAL MATERIAL

Καθετηριασμός δεξιάς κοιλίας. Σ. Χατζημιλτιάδης Καθηγητής Καρδιολογίας ΑΠΘ

Ventricular Assisting Devices in the Cathlab. Unrestricted

Mechanisms of heart failure with normal EF Arterial stiffness and ventricular-arterial coupling. What is the pathophysiology at presentation?

Hemodynamics: Cardiac and Vascular Jeff Davis, RRT, RCIS

Chapter 13 The Cardiovascular System: Cardiac Function

HEMODYNAMIC ASSESSMENT

Images have been removed from the PowerPoint slides in this handout due to copyright restrictions.

Adaptive servo ventilation improves cardiac pre and after load in heart failure patients with Cheyne-Stokes respiration

Impella Ins & Outs. CarVasz November :45 12:15

RV dysfunction and failure PATHOPHYSIOLOGY. Adam Torbicki MD, Dept Chest Medicine Institute of Tuberculosis and Lung Diseases Warszawa, Poland

PulsioFlex Patient focused flexibility

The Cardiovascular System

Unit 4 Problems of Cardiac Output and Tissue Perfusion

Cath Lab Essentials : LV Assist Devices for Hemodynamic Support (IABP, Impella, Tandem Heart, ECMO)

Circulation. Blood Pressure and Antihypertensive Medications. Venous Return. Arterial flow. Regulation of Cardiac Output.

The Use of Dynamic Parameters in Perioperative Fluid Management

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

-12. -Ensherah Mokheemer - ABDULLAH ZREQAT. -Faisal Mohammad. 1 P a g e

Ventriculo-arterial coupling and diastolic elastance. MasterclassIC Schiermonnikoog 2015

PHYSIOLOGY MeQ'S (Morgan) All the following statements related to blood volume are correct except for: 5 A. Blood volume is about 5 litres. B.

Transcription:

Method, Technology and Validity

Hemodynamic Basics Cardiovascular System Cardiac Output (CO) Mean arterial pressure (MAP) Variable resistance (SVR) Aortic valve Left ventricle Elastic arteries / Aorta Arterioles Flow Pressure Resistance SVR = MAP / CO MAP = CO x SVR CO = MAP / SVR

Hemodynamic Basics Parameters of Hemodynamics Pressure Blood Pressure (BP) Force against vessel walls Flow Cardiac Output (CO) Liters of blood pumped by heart in one minute Resistance Systemic Vascular Resistance (SVR) Force that must be overcome to expel blood from the heart

Thermodilution Typical Invasive Hemodynamic Monitoring Application: Pulmonary artery catheter (PAC) Bolus application with cold water (10 C, 5-10 ml) into right atrium Recording of temperature in the pulmonary artery Problems: Highly invasive (risk of bleedings, thrombosis and ruptures) Non continuous Cost-intensive

1mA @ 100 khz Impedance Cardiography (ICG) Non-invasive Beat-to-beat Hemodynamic Monitoring Diastole Systole Aortic valve is closed No blood flow in the aorta Red blood cells are orientated randomly Aortic valve opens Blood flow in the aorta (Windkessel function) Alignment of red blood cells Sources of the measured impedance change

ICG waveform and fiducial points Automatic detection of fiducial points Calculation of hemodynamic parameters (e.g. Stroke Volume [SV], Cardiac Output [CO], Thoracic Fluid Content [TFC])

Equation for Stroke Volume Estimation dzmax SV VEPT LVET Z 0 V EPT ( male) (0.17 H) 4.25 3 0.524 W H 16.58 V EPT ( female ) (0.17 H) 4.25 3 W 0.524 H 26.58 SV V EPT dz max Z 0 LVET W H Stroke Volume Patient related parameter (depending on weight, height, gender, ACM) Amplitude of the systolic wave of the ICG Base impedance (overall impedance of the thorax) Left Ventricular Ejection Time: time interval between opening and closing of the aortic valve, validated by ACM [ms] Weight of patient [kg] Height of patient [cm] Bernstein D.P., Crit Care Med, 1986

ACM Arterial Compliance Modulation Latest ICG technology for higher accuracy Earlobe sensor for registration of peripheral pulse wave Calculation of aortic compliance based on pulse wave velocity and curve shape parameters Detection of true X-point

ACM Arterial Compliance Modulation How does ACM work? Invasive aortic pressure curve allows accurate detection of aortic valve closing ACM curve clearly reflects the fiducial points of the aortic pressure curve and can be measured non-invasively Based on ACM the true X-point in the ICG signal can be defined

ACM Arterial Compliance Modulation Result of ACM technology stable and accurate LVET

ICG Hemodynamic Parameters Flow Stroke Volume / Index (SV / SI) Cardiac Output / Index (CO / CI) Resistance Systemic Vascular Resistance / Index (SVR / SVRI) Contractility Fluid Systolic Time Ratio (STR) Pre-ejection Period (PEP) LV Ejection Time (LVET) Velocity Index (VI) Acceleration Index (ACI) Thoracic Fluid Content (TFC)

Hemodynamic Components and Implications for Treatment Cardiac Output (CO) Heart rate (HR) Stroke Volume (SV) Preload Fluid Afterload Resistance Contractility (-) Neg. Chronotropes (+) Pos. Chronotropes (-) Neg. Diuretics (+) Volume Expanders (-) Vasodilators (+) Vasoconstrictors (-) Neg. Inotropes (+) Pos. Inotropes

Accuracy Richard Summers, et al. / Academic Emergency Medicine, 2003 Multicenter study including 680 patients comparing TD and ICG CO mean bias ± SD: -0.124 ± 0.75 (l/min) Albert, et al. / America Journal of Critical Care, 2004 Study including 29 patients with CHF comparing TD and ICG CO mean bias ± SD: -0.08 ± 0.26 (l/min) and correlation of r=0.89 to TD Van de Water, et al. / Chest, 2003 Study including 53 patients comparing TD and ICG CO mean bias ± SD: -0.18 ± 1.09 (l/min) and correlation of r=0.81 to TD

ICG Reproducibility N = 96 stable outpatient cardiac rehab patients highly reproducible on same-day show device sensitivity to normal hemodynamic changes on inter-day measurements...provides a baseline for objective determination of responses to therapeutic interventions. Parameter Day 1 vs. Day 2 95% conf. int. Variability (%) SI 39.9 44.3 + 5% CI 2.7 3.0 + 6% VI 40 50 + 10% SVRI 1921 2235 + 7% TFC 32 34 + 3% Verhoeve PE, et al. J Card Fail. 1998;4(3 suppl):53.

Reproducibility: ICG vs. Thermodilution (TD) N = 52 post-cabg patients with 3 sequential TD and ICG measurements superior intrapatient reproducibility compared with thermodilution via PAC. Comparison Correlation (R value) Stand. Dev. (l/min) TD 2 vs. TD 1 0.83 1.02 TD vs. TD TD 3 vs. TD 2 0.84 1.01 TD 3 vs. TD 1 0.83 1.07 ICG 2 vs. ICG 1 0.97 0.44 ICG vs. ICG ICG 3 vs. ICG 2 0.98 0.39 ICG 3 vs. ICG 1 0.97 0.43 Van De Water JM, Miller TW. Chest. 2003;123(6): 2028-2033.

ICG Limitations Physical Height: between 1.20 m and 2.30 m Weight: between 30 kg and 155 kg (Note: No age limit, just height and weight) Precautions HR > 250 bpm Septic shock (end stage sepsis) Severe aortic sclerosis Severe aortic valve regurgitation Extremely high blood pressure (MAP > 130) Cardiac arrhythmia Intra-aortic balloon pump

Applications of ICG ICG Monitoring Hypertension Management Cardiovascular Diagnosis Pacemaker Adjustment Fluid Management