ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

Similar documents
Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Pediatric pacemakers & ICDs:

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

Figure 2. Normal ECG tracing. Table 1.

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Timing cycles. Objectives Upon completion of this program the participant will be able to:

Electrocardiography for Healthcare Professionals

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Temporary Pacemakers

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Is This Thing Working?

Sinus rhythm with premature atrial beats 2 and 6 (see Lead II).

Pacing troubleshooting. NASPE training Lancashire & South Cumbria Cardiac Network

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

SARASOTA MEMORIAL HOSPITAL

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Antibradycardia Pacemakers

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Pacing Codes and Modes Concepts

Practice Questions.

Biventricular Pacemakers Sensing

Chapter 80 Implantable Cardiac Devices

Active Fixation Models: 7740, 7741 and 7742 Passive Fixation Models: 7731, 7732, 7735 and 7736

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

The Cardiac Pacemaker Case Study and its implementation in Safety-Critical Java and Ravenscar Ada

ICD: Basics, Programming and Trouble-shooting

BEDSIDE ECG INTERPRETATION

TIP CARD. Model Temporary External Pacemaker

Advanced ICD Concepts

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

Model 5392 EPG Temporary Pacer

CONSULTA CRT-P Model C4TR01

Cardiac Cycle. Each heartbeat is called a cardiac cycle. First the two atria contract at the same time.

Intermittent episodes of paced tachycardia: what is the cause?

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

Diagnostic capabilities of the implantable therapeutic systems

Temporary pacemaker : Programming &Trouble shooting

MONITORING PATIENTS WITH A TEMPORARY EXTERNAL EPICARDIAL PACEMAKER PURPOSE POLICY STATEMENTS SITE APPLICABILITY PRACTICE LEVEL/COMPETENCIES

11/21/18. EKG Pop Quiz. Michael Giocondo, MD Cardiac Electrophysiology Saint Luke s Cardiovascular Consultants

CORONARY ARTERIES HEART

Ass. Prof. Tomon Thongsri, MD Buddhachinaraj Phitsanuloke Hospital

RN-BC, MS, CCRN, FAHA

TEMPORARY PACEMAKERS HINTS ( DUAL CHAMBER 5392 PACER)

EKG Abnormalities. Adapted from:

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

You have a what, inside you?

Troubleshooting ICD. NASPE Training Lancashire & South Cumbria Cardiac Network

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

Pediatric Pacemaker Implantation Endocardial or Epicardial

Friedman, Rott, Wokhlu, Asirvatham, Hayes 201. Figure 65.7 Shortening of the AV interval during pacing.

Pacing Lead Implant Testing. Document Identifier


You have a what, inside you?

Human Anatomy and Physiology II Laboratory Cardiovascular Physiology

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

UNDERSTANDING YOUR ECG: A REVIEW

Electrocardiography for Healthcare Professionals

8/20/2012. Learning Outcomes (Cont d)

Implantation of a Permanent Tined Endocardial Electrode into Right Atrium during Open-heart Surgery: Report of 3 Cases

Cardiac rhythm detailed monitoring by an implanted pacemaker: The iecg solution

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

IBHRE Prep Key. Key.

A Rare Type of Pacemaker Mediated Tachycardia

3/26/15 HTEC 91. EKG Sign-in Book. The Cardiac Cycle. Parts of the ECG. Waves. Waves. Review of protocol Review of placement of chest leads (V1, V2)

Cardiac Telemetry Self Study: Part One Cardiovascular Review 2017 THINGS TO REMEMBER

Full file at

12 th International Winter Arrhythmia School Collingwood, Ontario February 7, Dr. Derek Yung. MD, FRCPC

Project Title Temporary Pacemaker Training Simulator

Pacemakers 12/04. Pacemakers. 1. What is a pacemaker?

Cardiovascular System Notes: Physiology of the Heart

Acute Evaluation of the Post Atrial Stimulation Evoked Response at Various Sites

12/1/2010. Human Heart. CS5219 Term Project Pacemaker: Modeling and Verification. Natural Pacemaker. Bradycardia

The conduction system

EHRA Accreditation Exam - Sample MCQs Invasive cardiac electrophysiology

Cardiac Pacing. Learning outcomes. Introduction. The cardiac impulse - its formation and its failure CHAPTER. To understand:

Contents. Example: Pacemaker in DDD Mode. I. Introduction II. Website and Relevant Documents III. Background Information IV.

Solara CRT-P MRI SureScan W1TR06

Lab Activity 24 EKG. Portland Community College BI 232

Interpreting Electrocardiograms (ECG) Physiology Name: Per:

Permanent Pacemaker Implantation Post Cardiac Surgery: A Cautionary Tale

Pacemaker Function Assessed by External Holter ECGRecording: A High Rate of Mild Malfunction

Welcome. Chris Stamper Technical Field Engineer.

Azure XT DR MRI SureScan W2DR01

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

PATIENT WITH ARRHYTHMIA IN DENTIST S OFFICE. Małgorzata Kurpesa, MD., PhD. Chair&Department of Cardiology

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

1 Cardiology Acute Care Day 22 April 2013 Arrhythmia Tutorial Course Material

Single-Lead DDD System: A Comparative Evaluation of Unipolar, Bipolar and Overlapping Biphasic Stimulation

BHRS Prep course Pub style Quiz NOT A

Call Medtronic at 1 (800) to verify the patient s current implanted system

Size (mm) (H W D) Mass (g) Volume (cc)

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

PART I. Disorders of the Heart Rhythm: Basic Principles

COGNIS. Specifications. COGNIS: Model N119 ZIP TELEMETRY CARDIAC RESYNCHRONIZATION THERAPY

OLBI Stimulation in Biatrial Pacing? A Comparison of Acute Pacing and Sensing Conditions for Split Bipolar and Dual Cathodal Unipolar Configurations

Transcription:

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ ΤΖΩΡΤΖ ΔΑΔΟΥΣ ΕΠΙΚΟΥΡΟΣ ΚΑΘΗΓΗΤΗΣ Α.Π.Θ. ΜΑΡΙΑ ΚΑΡΑΛΙΟΛΙΟΥ ΕΙΔΙΚΕΥΟΜΕΝΗ ΙΑΤΡΟΣ ΚΑΡΔΙΟΛΟΓΟΣ Β ΚΑΡΔΙΟΛΟΓΙΚΗ ΚΛΙΝΙΚΗ Α.Π.Θ. ΙΠΠΟΚΡΑΤΕΙΟ Γ.Ν.Θ.

5 Why a Pacemaker is Implanted A pacemaker is implanted to: Provide a heart rate to meet metabolic needs In order to pace the heart, it must capture the myocardium In order to pace the heart, it must know when to pace, i.e., it must be able to sense Today s pacemakers also: Provide diagnostic information About the pacing system About the patient We ll discuss how a pacemaker performs these functions in upcoming CorePace modules.

The Diseased Heart May: Prevent, or delay, impulse generation in the SA node Prevent, or delay, impulse conduction via the AV node SA node Inhibit impulse conduction via the bundle branches AV node

Intrinsic Pacemaker The heart generates electrical impulses that travel along a specialized conduction pathway Typically, the sinus node (SA node) generates the impulses Conduction paths include: Bachman s Bundle AV node Bundle of HIS Bundle Branches Purkinje Network This pattern of conduction makes it possible for the heart to pump blood efficiently

Cardiac Conduction Review SA node Atria Ventricles AV node Bundle branches

Implantable Pacemaker System Lead wire(s) Implantable pulse generator (IPG) Myocardial tissue

Implantable Pacemaker Circuit Implantable pulse generator (IPG): Battery Lead Circuitry Connector(s) Leads or wires Cathode (negative electrode) Anode (positive electrode) Body tissue IPG Anode Cathode

The Pulse Generator Contains a battery to provide energy for sending electrical impulses to the heart Houses the circuitry that controls pacemaker operations Includes a connector to join the pulse generator to the lead(s) Connector Block Circuitry Battery

Leads are Insulated Wires Deliver electrical impulses from the pulse generator to the heart Sense cardiac depolarization Lead

Lead Characterization Position within the heart Endocardial or transvenous leads Epicardial leads Fixation mechanism Active/Screw-in Passive/Tined Polarity Unipolar Bipolar Insulator Silicone Polyurethane Shape Straight J-shaped used in the atrium

Endocardial Passive Fixation Leads The tines become lodged in the trabeculae, a fibrous meshwork, of the heart Inserted via a cut-down or transvenous sheath Tines

Transvenous Active Fixation Leads The helix, or screw, extends into the endocardial tissue Allows for lead positioning anywhere in the heart s chamber The helix is extended using an included tool Inserted via a cut-down or transvenous sheath

Epicardial Leads Leads applied directly to the surface of the heart Fixation mechanisms include: Epicardial stab-in Myocardial screw-in Suture-on Applied via sternotomy or laproscopy

Lead Polarity Unipolar leads May have a smaller diameter lead body than bipolar leads Usually exhibit larger pacing artifacts on the surface ECG Bipolar leads Usually less susceptible to oversensing of non-cardiac signals (i.e., myopotentials, EMI, etc.) Unipolar lead Bipolar coaxial lead To tip (cathode)

20 Unipolar Pacing System The lead has only one electrode the cathode at the tip The pacemaker can is the anode Anode + When pacing, the impulse: Flows through the tip electrode (cathode) Stimulates the heart Returns through body fluid and tissue to the IPG can (anode) Cathode -

Bipolar Pacing System The lead has both an anode and cathode The pacing impulse: Flows through the tip electrode located at the end of the lead wire Stimulates the heart Returns to the ring electrode, the anode, above the lead tip Anode + Anode Cathode - Cathode

Lead Insulators Silicone insulated leads Inert Biocompatible Biostable Repairable with medical adhesive Historically very reliable Polyurethane Silicone Polyurethane insulated leads Biocompatible High tear strength Low friction coefficient Smaller lead diameter Newer bipolar lead insulation

24 Rate and Interval Review Calculated on the horizontal axis At 25 mm/s speed Each small box = 40 ms Each bold box = 200 ms How do you convert intervals to rate? 60,000 / (Interval in ms) = Rate in bpm Click for Answer

Single Chamber and Dual Chamber Pacing Systems

27 Single Chamber System The pacing lead is implanted in the atrium or ventricle, depending on the chamber to be paced and sensed How else can you describe this system? Click for answer Ventricular pacemaker with a bipolar lead

Paced Rhythm Recognition Atrial pacing at a rate of 60 ppm

Paced Rhythm Recognition Ventricular pacing at a rate of 60 ppm The spike is an artifact created by the pacemaker s output

30 Paced Rhythm Recognition On the ECG, note the difference between the paced and intrinsic beats. Why do you think this is? Click for answer Because the paced beat originates and is conducted differently than the intrinsic beat.

Advantages/Disadvantages of Single Chamber Pacing Systems Advantages Disadvantages Implant only one lead Pacemaker itself usually smaller Single ventricular lead does not provide AV synchrony Ventricular based pacing linked to AF and HF hospitalizations Single atrial lead does not provide ventricular backup if A-V conduction is lost

33 VVI Mode Chamber paced: Ventricle Chamber sensed: Ventricle Response to sensing: Inhibited A ventricular sense: Inhibits the next scheduled ventricular pace

38 VVI Example Chamber paced: Ventricle Chamber sensed: Ventricle Response to sensing: Inhibition VVI 60 = Lower Rate timer of 1000 ms Pacing every 1 second if not inhibited Lower Rate Timer 1000 ms Lower Rate Timer 1000 ms Lower Rate Timer. V P V P V P

39 VVI Example VVI 60 Chamber paced: Ventricle VVI 60 = Lower Rate timer of 1000 ms Pacing every 1 second if not inhibited Chamber sensed: Ventricle Response to sensing: Inhibition A ventricular sense interrupts the pacing interval, resets the lower rate timer, and inhibits the next scheduled paced (x) Lower rate timer 1000 ms Lower rate timer 1000 ms x V P V P V S V P

40 VOO Mode VOO 60 The intrinsic ventricular event cannot be sensed, and thus, does not interrupt the pacing interval. 1000 ms 1000 ms 1000 ms V P V P V P V P Chamber paced: Ventricle Chamber sensed: None Response to sensing: None VOO results in fixed-rate pacing in the ventricle. Placing a magnet over the pacemaker usually results in this behavior at known rates, for example, 85 ppm.

Dual Chamber System Two leads One lead implanted in the atrium One lead implanted in the ventricle These systems can be unipolar or bipolar Are these leads in the picture active or passive fixation? Click for answer Passive fixation. Note, the tines look like small grappling hooks, but are actually soft silicone.

Paced Rhythm Recognition Dual chamber pacing at a rate of 60 ppm The spike followed closely by the P- or R-wave is how we tell if the pacemaker has captured the myocardium

44 DDD Mode Chamber paced: Atrium & ventricle Chamber sensed: Atrium & ventricle Response to sensing: Triggered & inhibited An atrial sense: Inhibits the next scheduled atrial pace Re-starts the lower rate timer Triggers an AV interval (called a Sensed AV Interval or SAV) An atrial pace: Re-starts the lower rate timer Triggers an AV delay timer (the Paced AV or PAV) A ventricular sense: Inhibits the next scheduled ventricular pace

46 DDD Examples The Four Faces of DDD Atrial and ventricular pacing A P V P A P V P Atrial pace re-starts the lower rate timer and triggers an AV delay timer (PAV) The PAV expires without being inhibited by a ventricular sense, resulting in a ventricular pace

47 DDD Examples The Four Faces of DDD Atrial pacing and ventricular sensing A P V S A P V S Atrial pace restarts the lower rate timer and triggers an AV delay timer (PAV) Before the PAV can expire, it is inhibited by an intrinsic ventricular event (R-wave)

48 DDD Examples The Four Faces of DDD Atrial sensing, ventricular pacing A S V P A S V P The intrinsic atrial event (P-wave) inhibits the lower rate timer and triggers an AV delay timer (SAV) The SAV expires without being inhibited by an intrinsic ventricular event, resulting in a ventricular pace

49 DDD Examples The Four Faces of DDD Atrial and ventricular sensing A S V S A S V S The intrinsic atrial event (P-wave) inhibits the lower rate timer and triggers an AV delay timer (SAV) Before the SAV can expire, it is inhibited by an intrinsic ventricular event (R-wave)

50 Dual Response to Sensing DDD The pacemaker can: Inhibit and trigger A P-wave inhibits atrial pacing and triggers an SAV interval An atrial pace triggers a PAV interval An R-wave inhibits ventricular pacing We ll see later how a PVC can affect atrial timing

54 DDI Mode Chamber paced: Atrium & ventricle Chamber sensed: Atrium & ventricle Response to sensing: Inhibited An atrial sense: Inhibits the next scheduled atrial pace Re-starts the lower rate timer An atrial pace: Re-starts the lower rate timer Starts an AV delay timer (the Paced AV or PAV) A ventricular sense: Inhibits the next scheduled ventricular pace

55 DDI Example Why would we want a dual chamber pacing mode that does not trigger an SAV? P P P P P P P P P P P P What rhythm is this? Click for Hint The underlying rhythm is an atrial tachycardia.

56 DDI Example Why would we want to use DDI? To control pacemaker timing during atrial tachycardias Avoids a fast paced ventricular response to AT/AF DDD tracking the AF May limit patient symptoms during AT/AF DDI Not tracking the AF Click to change 540ms = 110bpm This function has come to be called Mode Switching

65 Nuggets Note that in both the single and dual chamber examples: When the device paces for the purposes of timing capture is assumed Some newer devices have algorithms to check for capture Sensing is critical to timing If the device fails to sense, undersensing, it will usually pace If it oversenses, e.g., senses myopotentials, it will inhibit pacing

66 Remember This Strip? Intermittent loss of capture (LOC) Note how the underlying timing is unaffected by the failure to capture For timing purposes, pace = capture Click for Answer DD D Review question: Name some possible causes for this condition. Incomplete fracture, insulation failure, lead dislodgement, poor connection in header, programming error, change in pacing thresholds

72 Diagnose This Strip Undersensing, the device fails to reliably see P-waves How do we know this is undersensing? Click for Answer DD D Because: The atrial lower rate timer is not inhibited there are atrial pacing spikes The intrinsic P-waves do not start an SAV

85 Status Check Identify the most likely pacemaker that resulted in this strip Click for answer Atrial pacemaker Ventricular pacemaker Dual chamber pacemaker

86 Status Check Which pacemaker modes could be operating on this strip? Assume normal pacemaker operation Click for Answer A. DDD B. VVI C. AAI D. DOO A. DDD Yes, the intrinsic rate could be faster than the lower rate, and the PAV/SAV is longer than the P-R interval. B. VVI Yes, the ventricular rate is faster than the lower rate, thus inhibiting the IPG. C. AAI Yes, the atrial rate is faster than the lower rate, thus inhibiting the IPG. D. DOO No, DOO results in fixed rate pacing. No sensing is possible, no inhibition is possible.

87 Status Check Which pacemaker modes could be operating on this strip? Assume normal pacemaker operation Click for Answer A. DDD B. VVI C.AAI D.DOO A. DDD Yes, this is very likely the DDD mode. B. VVI Yes, it could be, but the consistent A-V relationship should make us suspicious. C. AAI No, not possible. Cannot have ventricular pacing in the AAI mode. D. DOO No, DOO results in fixed rate pacing. No sensing is possible, no inhibition is possible. We would see atrial and ventricular pacing if this was DOO.

88 Status Check Which pacemaker modes could be operating on this strip? Assume normal pacemaker operation Click for Answer A. DDD Yes, this is very likely the DDD mode. This is sometimes called tracking, as the ventricle is tracking the atrium. A. DDD B. DDI C.VOO D.DOO B. DDI Not possible. The consistent AV intervals suggest the P-wave is triggering an SAV. DDI inhibits only, triggering not possible. C. VOO Not likely because of the consistent AV intervals. Unable to diagnose until we see the IPG response to an intrinsic ventricular event (evidence of sensing). D. DOO No, DOO results in fixed rate pacing. No sensing is possible, no inhibition is possible. We would see atrial and ventricular pacing if this was DOO.

ΕΥΧΑΡΙΣΤΩ

97 Status Check Provide an explanation for why the pacemaker did not capture (think of the electrical concepts)? Click for answer Lead fracture, failing battery, improper programming, insulation failure any or all might explain this. We ll discuss how to determine the cause in Evaluation and Troubleshooting.

98 Status Check Identify the most likely pacemaker that resulted in this strip Click for answer Atrial pacemaker Ventricular pacemaker Dual chamber pacemaker