Analysis of Commercially Available Products Containing Stevia

Similar documents
Sensitive Analysis of Commonly Used Artificial and Natural Sweeteners Including Stevia and Their Impurities and Degradation Products

Determination of Steviol Glycosides by HPLC with UV and ELS Detections

Steviol Glycosides from Stevia rebaudiana Bertoni

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

REBATEN. Great Taste Improvement of Stevia Sweetener DAEPYUNG

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni

INGREDIENTS

Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Impurity Profiling of Carbamazepine by HPLC/UV

The Stevia Plant. Zero in on Stevia Sweegen, Inc. All rights reserved.

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Application Note Ginseng for Ginsenosides by HPLC. Botanical Name: Common Names:

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

HPLC Analysis of Sugars

STANDARD OPERATING PROTOCOL (SOP)

Analysis of Cannabinoids in Cannabis by UHPLC Using PDA Detection

STANDARD OPERATING PROTOCOL (SOP)

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

Analysis of Cannabinoids in Hemp Seed Oils by HPLC Using PDA Detection

Application Note. Treatment of poor memory, memory loss, Alzheimer s disease, peripheral vascular disease.

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

Analysis of Emulsifiers in Foods by High Pressure Liquid Chromatography and Corona Charged Aerosol Detection

Analysis of Cannabinoids in Hemp Seed Oils by HPLC Using PDA Detection

Application Note. Authors. Abstract. Food

Technological Experiences and Advances in the Beverage Sector

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Amudha S et al., Asian Journal of Pharmthiaceutical Technology & Innovation, 04 (21); 2016; Research Article

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

High intensive sweeteners An overview of non-nutritive (artificial) sweeteners used to reduce calories

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Available online Research Article

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

EASIMIP TM PATULIN Product Code: P250 / P250B

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

UNIVERSITI TEKNOLOGI MARA

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Authors. Abstract. Introduction. Environmental

Innovation Spotlight:

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

Things you must know about stevia applications in chocolate

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Rapid Quantitative Analysis of Cannabidiol from Consumer Products Using UltraPerformance Convergence Chromatography

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

ISSN (Print)

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

Development and Validation of Improved RP-HPLC method for Identification and Estimation of Ellagic and Gallic acid in Triphala churna

Analysis of Phenolic Antioxidants in Edible Oil/Shortening Using the PerkinElmer Altus UPLC System with PDA Detection

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Tramadol Hydrochloride Extended-Release Tablets. Expert Committee Chemical Medicines Monographs 2 Reason for Revision Compliance

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

About HYET. Who We Are. Our Aims

Analysis of Phospholipids in Natural Samples by Normal Phase HPLC and Corona Charged Aerosol Detection

Ergovaline. [Methods listed in the Feed Analysis Standards] 1 Liquid chromatography Note 1, 2 [Feed Analysis Standards, Chapter 5, Section 2

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

This revision also necessitates a change in the table numbering in the test for Organic Impurities.

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at RESEARCH ARTICLE

Application Note. Introduction. Analysis of Total Aflatoxins in Food by HPLC and UHPLC

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Determination of Water- and Fat-Soluble Vitamins in Nutritional Supplements by HPLC with UV Detection

Pelagia Research Library

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Marc Plante, Bruce Bailey, and Ian N. Acworth Thermo Fisher Scientific, Chelmsford, MA, USA

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016.

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

Aripiprazole (USP) We have followed the current Aripiprazole USP monograph (USP38-NF33):

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Direct Determination of Native N-linked Glycans by UHPLC with Charged Aerosol Detection

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

DETERMINATION OF AR- TIFICIAL SWEETENERS IN LIQUID FOODS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

CORRELATION BETWEEN GLYCOSIDES IN LEAVES AND AGRONOMIC TRAITS OF STEVIA REBAUDINA BERTONI

Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS

World Journal of Pharmaceutical Research

Development and validation of RP-HPLC method for simultaneous estimation of gliclazide and metformin in pure and tablet dosage form

Transcription:

Analysis of Commercially Available Products Containing Stevia Application note The commercial use of the herb stevia refers to the extracts from the Stevia rebaudina, Bertoni plant. Although originally native to Paraguay and Brazil, it is now cultivated around the world. The plant contains at least eight diterpene glycosides ranging in both relative sweetness and abundance. For example, the two major glycosides stevioside (Figure 1) and rebaudioside A (Reb A) occur at ~ 3-10% and ~1-2% w/w, respectively in the dried plant. They are reported to be up to 250 times sweeter than sucrose. In a few countries (e.g., Japan) extracts from the stevia plant have been used as a sweetener for centuries. However, up until recently, regulations in the United States prohibited the use of Stevia extracts in food or beverages, even though they could be purchased as nutritional supplements. This recently changed. In December 2008, the FDA issued GRAS affirmations for two commercial products containing Reb A: Truvia (Coca-Cola Company) and PureVia (PepsiCo). Both companies have also announced that beverages containing this sweetener will be available in 2009. The FDA GRAS affirmation does not provide approval for the use of all Stevia components in food products, just Reb A. Therefore, Stevia products must be highly purified and characterized prior to use. This Application Note describes a routine gradient HPLC-Corona Charged Aerosol Detection (CAD ) method that can be used to characterize Stevia components in raw and commercially available products. Universal detection has merits over the use of absorbance-based detectors for this analysis. Figure 1. Stevioside. Method Parameters Column: Shiseido Capcell PAK C18 AQ, 4.6 x 250mm, 5µm Temperature: 50 o C : Corona CAD Plus Nebulizer Heater: On Filter: None Mobile Phase A: Deionized Water (DI), Acetonitrile, Trifluoroacetic Acid (TFA) (95:5:0.1) Mobile Phase B: Acetonitrile, DI (95:5) Gradient Profile: Table 1 Flow Rate: 1.0 ml/min Injection Volume: 10 µl at 10 C UV Wavelength: 210 nm Time % Mobile Phase B 0.0 5 3.0 5 30.0 90 35.0 90 40.0 5 45.0 5 Table 1. Gradient Profile.

Application note Sample Preparation and Analysis Commercially available products containing Stevia were purchased at a local supermarket. The products ranged in their classifications and recommended serving sizes (Table 2). The samples and standards were prepared in a aqueous methanol (20%) solution and sample injection concentrations are listed in Table 2. The Stevia rebaudiana Bertoni leaves were purchased from Sigma-Aldrich (St. Louis, MO). The dry leaf extract was prepared by placing 83mg of dry leaf in 10mL of hot deionized water. The solution was then filtered through a 0.2µm Nylon filter and the filter was washed with an additional 15mL of the aq. methanol solvent. The solution was then diluted 3 fold in order to fall within the standard curve concentrations. Standards of Reb A, Stevioside and Isosteviol were purchased from ChromaDex (Irvine, CA) and were certified to have > 97% purity. The stock solutions for Stevioside, Reb A, and Isosteviol were prepared at 167, 159 and 91ppm, respectively. The five point calibration curve solutions, ranging from 11 to 56ppm, as well as limit of detection (LOD) solutions were prepared by appropriate dilutions of the stock solutions. Two injections of each sample and three injections of the individual standards were analyzed. Injections of the standards and samples were interlaced over a three day period. Results and Discussion Linearity, Reproducibility, Sensitivity and Accuracy Both CAD and UV data were evaluated for linearity, sensitivity and accuracy. Three repetitive injections were made of the five different calibration solutions and the data obtained were analyzed for linearity and reproducibility. For the CAD, linear regression analysis was used (Figure 2); CAD and UV results are listed in Table 3. Linear Correlation Coefficients Rebaudioside A Stevioside CAD 0.9986 0.9978 UV @210 0.9992 0.9994 Table 3. Linearity Data. The reproducibility of the analysis was evaluated by calculating the % RSD for repetitive injections of each point on the five point curves. The average RSD calculations for the CAD and UV detection are listed in Table 4. Average % RSD Rebaudioside A Stevioside CAD 0.77% 0.52% UV @210 2.44% 1.75% Table 4. RSD Data. Product Distributor Classification Serving Size 1 packet (g) Injection Concentration (mg/ml) Truvia TM Cargill, Incorporated Table Sugar 3.5 5.9 PureVia TM Whole Earth Sweetener Company Table Sugar 2 3.6 SweetLeaf Sweetener TM SweetLeaf Dietary Supplement 1 2.6 Stevia Extract IN Cumberland Packing THE RAW TM Corp Dietary Supplement 1 1.0 Stevia Supreme TM Stevia Company, Inc. Dietary Supplement 1 1.1 SweetLeaf Stevia Wisdom Natural Extract Brands Dietary Supplement 0.025 0.086 Table 2. Product Information. The sensitivity of the CAD and UV was evaluated by determining the LOD for the Stevioside and Reb A (Table 5). The CAD was far more sensitive than UV for all components of Stevia samples (see Figures 3 and 4). Limit of Dection (mass on column) Rebaudioside A Stevioside Isosteviol CAD 4 ng 4 ng 60 ng UV @210 65 ng 65 ng > 900 ng Table 5. Limit of Detection.

The accuracy of the analysis was evaluated two ways: By spiking a known amount of the standards into a sample and calculating recovery. The recovery for Reb A was 98.4% for the CAD compared to 92.2% recovery for the UV detector. Recovery of Stevioside was 103.4% for the CAD and 101.2% for the UV detector. Rebaudioside A Stevioside CAD Response UV Response From the manufacturer s reported value. The RebA reported value was 40% of Reb A in SweetLeaf Stevia Extract compared to a CAD value of 40.04% (representing 100.1% recovery). Figure 3. Difference in Response Between s. 1600 1400 Response (peak area) 1200 1000 800 600 400 200 0 0 100 200 300 400 500 600 Mass on Column (ng) Rebaudioside A R 2 = 0.9986 Stevioside R 2 = 0.9978 UV values obtained for all products (containing either all Reb A or similar concentrations of both Reb A and Stevioside) - between 99-105% CAD/UV. For the Stevia supreme and the Stevia leaves the Reb A correlation was 76% and 95%, respectively, while those of Stevioside were 108% and 94%, respectively. Unfortunately, the actual content of each component in these products is not available from the manufacturer, so comparison to calculated results is not possible. Figure 2. Analyte Linearity. Rebaudioside A and Stevioside Concentrations in Commercial Products Linear regression analysis of the five point calibration was used to calculate a w/w% of the two major glycosides in each of the products indicated in Table 2. All of the products contained Reb A and values were calculated and are illustrated in Figure 5 for both the UV and CAD. The Truvia, PureVia, and Stevia Extract In the Raw are purified Reb A sweeteners and no Stevioside was detected. The weight % of the Stevioside was calculated for each of the other products and is presented in Figure 6. The CAD shows good correlation to the Rebaudioside A Stevioside Figure 4. Difference in Response Between s, Presented at Higher Sensitivity. CAD Response UV Response

weight percent 45.00% 40.00% 35.00% 30.00% 25.00% 20.00% 15.00% 10.00% 5.00% 0.00% CAD 0.84% 1.37% 1.53% Truvia UV PureVia SweetLeaf Sweetener 3.91% Stevia "In the Raw" 0.68% Stevia Supreme 40.04% SweetLeaf Extract 1.88% Leaves (Sigma) Figure 5. The Weight Percent of Rebaudioside A in 6 Commercially Available Stevia Sweeteners and the Dried Stevia Leaves Calculated using Corona CAD Detection and UV Detection @ 210nm. % Data for CAD. Weight Percent 40.00% 35.00% 30.00% 25.00% 20.00% 15.00% 10.00% 5.00% 0.00% CAD UV 1.70% 2.05% 34.46% 9.25% SweetLeaf Sweetener Stevia Supreme SweetLeaf Extract Leaves (Sigma) Figure 6. The Weight Percent of Stevioside in 3 Commercially Available Stevia Sweeteners and the Dried Stevia Leaves Calculated using Corona CAD Detection and UV Detection @ 210nm. % Data for CAD. Stevia in Beverages The FDA GRAS declaration now permits the commercial production of Stevia-based zerocalorie beverages. The Zieva company (Seattle, WA) began producing a line of alternative soft drinks with Stevia early in 2008 marketed as carbonated Stevia supplements. The Zevia Natural Cola and the Zevia Natural Twist flavors were purchased and diluted by diluting 1mL of each drink with 5mL of aq. Methanol solvent. The content of Reb A was calculated to be 0.016% in both drinks; the content of Stevioside was calculated to be 0.015% w/w in the twist and 0.016% w/w in the Zevia Natural Cola. Isosteviol and Other Components Isosteviol is a derivative of Stevioside and has been evaluated to determine whether there are any negative health implications when using Stevia sweeteners. This material possesses a weak chromophore and no signal was observed for the 90ppm standard by UV detection at 210 nm. On the other hand, the signal on the CAD was strong the limit of detection was determined to be ~60ng on column. The compound was not detected in any of the commercial products tested. As shown in Figures 5 and 6 the diterpene glycosides from Stevia constitute a small percentage of the table sugars total mass. Other major components in Stevia products include sugar alcohols (Erythritol), dextrose, and Inulin soluble fiber. None of these compounds have strong UV chromophores but all can be detected by charged aerosol detection. In this method, these compounds are not retained other CAD methods exist for their measurement.

The Corona Charged Aerosol Conclusion A gradient HPLC-UV-CAD method was developed for the routine analysis of sweeteners obtained from the Stevia rebaudina, Bertoni plant. The method is accurate, sensitive and reproducible. Since the sweetness and potential aftertaste of the different diterpene gyclosides is very important, many companies must ensure that there products are produced consistently using a viable analytical method. The Corona Charged Aerosol has great applicability throughout the manufacturing process to ensure that product quality and consistency remains uniform. The Charged Aerosol detector s universality and enhanced sensitivity over UV detection allows for additional components from Stevia to be detected in foods and beverages. Ordering Information Corona Plus Charged Aerosol 70-7041 Thermal Organizer Module 70-5499TA Nitrogen generator 70-6003 Pump, model 584 with RS232 70-7058 Gradient Upgrade 70-7057 Autosampler, model 542 70-4152 Column, Capcell Pak Aq 88-92044 EZChrom Elite (TM) for ESA software including PC 70-5073 ESA Biosciences, Inc. 22 Alpha Road Chelmsford, MA 01824-4171 USA +1 978.250.7000 Phone +1 978.250.7090 Fax +1 800.959.5095 US Toll free Email: info@esainc.com www.esainc.com ESA Analytical Brook Farm, Dorton, Aylesbury Buckinghamshire HP18 9NH England +44 (0)1844 239381 Phone +44 (0)1844 239382 Fax Email: info@esainc.com www.esainc.com ESA Biosciences, Inc. is an ISO 9001 and 13485 Certified Company ESA, Corona and CAD are registered trademarks of ESA Biosciences, Inc. The Corona CAD is covered by multiple patents 70-8455 Rev A