21st Century Visual Field Testing

Similar documents
Evolving glaucoma management True diagnostic integration for the preservation of vision

FORUM Glaucoma Workplace from ZEISS Clinical Interpretation Guide

3/16/2018. Perimetry

Financial Disclosure. Visual Field Interpretation RELIABILITY VISUAL FIELD INTERPRETATION IN GLAUCOMA METHODS OF DATA PRESENTATION

Misleading Statistical Calculations in Faradvanced Glaucomatous Visual Field Loss

CLINICAL SCIENCES. Glaucoma Monitoring in a Clinical Setting

Expanding your field of vision. Visual Field Analyzers from Carl Zeiss

Visual Fields Shawn L. Cohen, M.D. Part 2 of 4. Definitions / Tables (Part 2 of 2) Static Perimetry (Humphrey, Octopus)

Access to the published version may require journal subscription. Published with permission from: Elsevier

Citation for published version (APA): Wesselink, C. (2017). Glaucoma care optimised in an ageing population [Groningen]: Rijksuniversiteit Groningen

VISUAL FIELDS. Visual Fields. Getting the Terminology Sorted Out 7/27/2018. Speaker: Michael Patrick Coleman, COT & ABOC

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

CORRELATING OF THE VISUAL FIELD INDEX WITH MEAN DEVIATION AND PATTERN STANDARD DEVIATION IN GLAUCOMA PATIENTS

Present relevant clinical findings of four landmark glaucoma trials OHTS, EMGT, CNTGS and CIGTS.

New Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD

VISUAL FIELD TESTING OCCUpies

Learn Connect Succeed. JCAHPO Regional Meetings 2017

HFA3 with SITA Faster Frequently Asked Questions

Definitions. Indications for Perimetry. Indications for Perimetry. Purposes of Perimetry. Indications for Perimetry 3/4/2015

Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial

STANDARD AUTOMATED PERIMETRY IS A GENERALLY

Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1

Diagnosing open-angle glaucoma may be particularly

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

Investigative Ophthalmology & Vision Sciences MSc Course. Glaucoma Module. Visual Field Reliability Indices. David Henson 2014.

Science & Technologies

Cirrus TM HD-OCT. Details defi ne your decisions

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Practical approach to medical management of glaucoma DR. RATHINI LILIAN DAVID

Clinical Study Visual Field Loss Morphology in High- and Normal-Tension Glaucoma

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

CLINICAL SCIENCES. (FDP) was designed to emphasize the response characteristics of the parasol

Test-retest variability in visual field testing using frequency doubling technology

The Evolution of Fundus Perimetry

Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

Glaucoma Progression. Murray Fingeret, OD

53 year old woman attends your practice for routine exam. She has no past medical history or family history of note.

The Role of the RNFL in the Diagnosis of Glaucoma

F requency doubling technology (FDT) perimetry was

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Intro to Glaucoma/2006

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma

City, University of London Institutional Repository

Author(s) Sekiya, Takuro; Yoshimura, Nagahisa. Citation Japanese journal of ophthalmology (

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors

CHAPTER 13 CLINICAL CASES INTRODUCTION

OCT in the Diagnosis and Follow-up of Glaucoma

Reading centers are important in clinical trials to

Visual Field Interpretation Anthony B. Litwak, OD, FAAO VA Medical Center Baltimore, MD

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

Hidden LED Array Perimeter IVS-201A / IVS-201B. Reliable Accurate Economical. Lis t ic

Glaucoma: Diagnostic Modalities

The improvement in perimetric results occurring over

Linking structure and function in glaucoma

Baseline Visual Field Characteristics in the Ocular Hypertension Treatment Study

MOVE IT OR LOSE IT: THE ROLE OF KINETIC VISUAL FIELDS

Citation for published version (APA): Stoutenbeek, R. (2010). Population based glaucoma screening Groningen: s.n.

Relationship Between Structure

Lifetime Risk of Blindness in Open-Angle Glaucoma.

Supplementary Appendix

Advances in OCT Murray Fingeret, OD

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

CLINICAL SCIENCES. optic neuropathy characterized

Case Report Optic Disk Pit with Sudden Central Visual Field Scotoma

Perimetry Phobia: Don t fear the field Savory Turman, COMT, CPSS

A Visual Field Index for Calculation of Glaucoma Rate of Progression

Characteristics of Frequency-of-Seeing Curves in Normal Subjects, Patients With Suspected Glaucoma, and Patients With Glaucoma

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Optic Disk Pit with Sudden Central Visual Field Scotoma

Cirrus TM HD-OCT. Details define your decisions

7/25/2018. You talk about glaucoma in cup-to-disc ratios ASSESSING THE OPTIC DISC: IS PHOTOGRAPHY STILL NECESSARY IN THE OCT ERA?

In recent years, considerable interest. Short wavelength automated perimetry. Physiological Aspects of SWAP. John M. Wild

Available online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):

International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN

As methods become available to measure the structure of

Dr Taha Abdel Monein Labib Professor of Eye Surgery Cairo University.

Automated Visual Field Analysis for Glaucoma

Learning Effect and Test-Retest Variability in Healthy Subjects and Patients with Primary Open Angle Glaucoma Using Rarebit Perimetry

Research Article Long-Term Clinical Course of Normal-Tension Glaucoma: 20 Years of Experience

PRIMUS 200 from ZEISS The essential OCT

A New Model for Assessment of Change in Visual Function in Diabetes

T he retinal ganglion cells of different sizes have distinct

LABORATORY SCIENCES. Spatial and Temporal Processing of Threshold Data for Detection of Progressive Glaucomatous Visual Field Loss

PATTERNS OF GLAUCOMATOUS VISUAL FIELD LOSS IN SITA FIELDS AUTOMATICALLY IDENTIFIED USING INDEPENDENT COMPONENT ANALYSIS

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

LUP. Lund University Publications Institutional Repository of Lund University

Sequential non-arteritic anterior ischemic optic neuropathy (NAION) Jonathan A. Micieli, MD Valérie Biousse, MD

Early detection and control of disease progression or

RETINAL NERVE FIBER LAYER

NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS

Pit-like changes of the optic nerve head

Evaluation of Retinal nerve fiber layer thickness, mean deviation and visual field

CLINICAL SCIENCES. Steven L. Mansberger, MD; Pamela A. Sample, PhD; Linda Zangwill, PhD; Robert N. Weinreb, MD

Transcription:

Supplement to Supported by an educational grant from Carl Zeiss Meditec, Inc. Winter 2011 21st Century Visual Field Testing the Evolution Continues

21st Century Visual Field Testing 21st Century Visual Field Testing the Evolution Continues Diagnostics are a key factor in disease management, especially in glaucoma. Although tremendous advances have been made in ophthalmic imaging during the past few years, visual field testing remains essential to the diagnosis and management of glaucoma. The Humphrey Field Analyzer (Carl Zeiss Meditec, Inc., Dublin, CA) has been widely recognized as the gold standard in automated visual field testing for more than 25 years, and it has provided clinicians with a widely accepted and broadly available language of perimetry that most doctors understand. All major glaucoma clinical trials have relied upon Humphrey perimetry, including the Advanced Glaucoma Intervention Study (AGIS), the Collaborative Initial Glaucoma Treatment Study (CIGTS), the Early Manifest Glaucoma Trial (EMGT), the Normal Tension Glaucoma Study (NTGS), and the Ocular Hypertension Treatment Study (OHTS). 1-5 This article briefly reviews some of the reasons why the Humphrey perimeter has come to enjoy this status. STANDARDIZATION Among the many contributions to ophthalmology made by Hans Goldmann was the first universally standardized method for manual visual field testing: Goldmann perimetry. Goldmann perimeters all over the world used the same standardized stimuli and background level, allowing doctors to communicate in a common perimetric language. The Humphrey automated perimeter can be considered to be the modern day extension of Goldmann s standardization efforts in terms of availability and worldwide acceptance. The Humphrey Field Analyzer is further enhanced by widely accepted standardized testing strategies, normative data, and analytical methods, all of which provides doctors not only with an international standard for visual field testing but also a standard language for communicating results. Such uniformity has provided universally accepted criteria for glaucoma staging and diagnosis that were not widely available even 20 years ago. TESTING ALGORITHMS Standardization by itself is insufficient if the methods used are not sensitive, reproducible, and efficient. In the early 1980s, automated threshold testing strategies could take as long as half an hour per eye, making them neither clinically practical nor well accepted by patients. While it was simple to reduce testing time by sacrificing precision and reproducibility, it was not until the late 1990s that strategies emerged that successfully reduced testing time while maintaining diagnostic performance. 6 These new strategies came to be known as the Swedish Interactive Threshold Algorithm (SITA) and now include the SITA Standard, SITA Fast, and SITA SWAP (short-wavelength automated perimetry). The SITA methods effectively cut testing time in half without giving up reproducibility or diagnostic performance. 7,8 The SITA strategies have provided clinicians with a broad set of testing options that can be tailored to specific patient needs. SITA Standard 24-2 testing can run in as little as 4 minutes and is usually the most reliable option. SITA Fast 24-2 testing can be performed in as little as 2 minutes and provides a reasonable alternative in situations that demand the briefest of true threshold tests. Some threshold testing methods save time by assuming that responses obtained at nearby test-point locations also apply to the point being tested. This shortcut blurs test points together, effectively decreasing the number of truly tested points. It is important to note that SITA is a true threshold test, which is to say that SITA methods still determine threshold at each tested location in the visual field by finding at least one brightness that can be seen and one that cannot be seen. STANDARDIZED ANALYSIS Once test data have been acquired, the next immediate task is to interpret the results. If the Humphrey perimeter is the gold standard of visual field testing, then STATPAC (Carl Zeiss Meditec, Inc.) is the universal lan- 2 I SUPPLEMENT TO GLAUCOMA TODAY I WINTER 2011

The Evolution Continues INNOVATIVE HIGHLIGHTS OF THE HUMPHREY FIELD ANALYZER SWEDISH INTERACTIVE THRESHOLD ALGORITHM (SITA) SITA is a family of testing strategies that measure threshold sensitivity and reliability parameters efficiently, thereby achieving optimal measurements in minimal time. STATPAC STATPAC is a trademark for Humphrey software that performs a series of statistical calculations on visual field test results. Displays include single-field analysis, Guided Progression Analysis (GPA), change analysis, and overview. GUIDED PROGRESSION ANALYSIS (GPA) GPA is a new approach to detecting progression events and trends that spans several platforms including the Humphrey Field Analyzer (HFA) and Cirrus HD-OCT (both products from Carl Zeiss Meditec, Inc., Dublin, CA). On the HFA, the event-based GPA identifies statistically significant progression. Two visual fields are required to establish a baseline examination. GPA flags points exceeding expected patient variability and employs strict progression criteria from the Early Manifest Glaucoma Trial. VISUAL FIELD INDEX The Visual Field Index (VFI) is a perimetric staging index that is designed to be less affected by cataracts. VFI is expressed as a percentage, where 100% represents a normal visual field and 0% represents a perimetrically blind field. VFI PLOT The VFI Plot applies linear regression analysis to series of test results to help identify patients who are progressing at rapid rates. The VFI Plot can be found in the new GPA of the HFA. guage of perimetry. STATPAC software compares results to clinically validated, world-class, proprietary agenormative and glaucoma databases. Data analyses not only include simple plain language interpretations relative to normal or to baseline, but they also provide specific quantitative information that can help doctors make difficult treatment decisions. STATPAC analysis software is universally available, simple to use, and well documented in the peer-reviewed literature. In a world where simplicity is valued but details are often necessary, the inventors of STATPAC have made consistently practical and useful design decisions, and they continue to do so a quarter of a century after the initial introduction of the product. HUMPHREY PERIMETRY PAST AND FUTURE With the recent and in many ways stunning improvements in ophthalmic imaging, it is easy to lose track of the continuing role of standardized automated visual field testing in glaucoma management. Continuing advances in this field, however, confirm the role of Humphrey perimetry as the gold standard in the diagnosis and management of glaucoma. 1. Gordon MO, Kass MA. The Ocular Hypertension Treatment Study: design and baseline description of the participants. Arch Ophthalmol. 1999;117:573-83. 2. Leske MC, Heijl A, Hyman L, Bengtsson B. Early Manifest Glaucoma Trial: design and baseline data. Ophthalmology. 1999;106:2144-2153. 3. The effectiveness of intraocular pressure reduction in the treatment of normal-tension glaucoma. Collaborative Normal-Tension Glaucoma Study Group. Am J Ophthalmol. 1998;126:498-505. 4. The Advanced Glaucoma Intervention Study (AGIS): 1. Study design and methods and baseline characteristics of study patients. Control Clin Trials. 1994;15:299-325. 5. Musch DC, Lichter PR, Guire KE, Standardi CL. The Collaborative Initial Glaucoma Treatment Study: study design, methods, and baseline characteristics of enrolled patients. Ophthalmology. 1999;106:653-662. 6. Bengtsson B, Heijl A. SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucoma. Acta Ophthalmol Scand. 1998;76:431-437. 7. Bengtsson B, Heijl A. Comparing significance and magnitude of glaucomatous visual field defects using the SITA and Full Threshold strategies. Acta Ophthalmol Scand. 1999;77:143-146. 8. Bengtsson B, Heijl A. Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma. Acta Ophthalmol Scand. 1998;76:268-272. WINTER 2011 I SUPPLEMENT TO GLAUCOMA TODAY I 3

21st Century Visual Field Testing Case Studies BY NATHAN M. RADCLIFFE, MD Case No. 1 Early Perimetric Glaucoma Figure 1A shows the Humphrey Field Analyzer (HFA; Carl Zeiss Meditec, Inc., Dublin, CA) visual field single field analysis report for a 34-year-old man with early glaucoma and an abnormal Glaucoma Hemifield Test (GHT) on Swedish Interactive Threshold Algorithm (SITA) Standard. The GHT is an automated, empirically derived algorithm that detects up-down asymmetry and symmetrically depressed visual field abnormalities. 1 By comparing five corresponding sectors from the superior and inferior hemifields, the GHT serves as a sensitive indicator of focal visual field loss. Analysis of this patient s glaucomatous visual field (Figure 1A) shows only two significantly (P <.5%) depressed points on the total and pattern deviation plots. Although only a small region of the field is depressed, these two points are deeply depressed at 12 db and 9 db below the ageadjusted normal, as seen on the total deviation plot. The fixation losses, false positive and false negative errors are all within acceptable limits, and the gaze tracker demonstrates steady fixation. The prior SITA Standard test from several months earlier was completely normal, and fluctuation between normal and abnormal results may occur in early perimetric glaucoma. 2 Note that the Visual Field Index (VFI) is still high at 96%, demonstrating that very little field loss is required in order for the GHT to become abnormal. The mean deviation is still in the positive range at +0.13 db, indicative of the overall preserved hill of vision. The focal Figure 1A. HFA Single Field Analysis. Figure 1B. Cirrus HD-OCT ONH and RNFL OU analysis. 4 I SUPPLEMENT TO GLAUCOMA TODAY I WINTER 2011

The Evolution Continues superior defect has distorted the shape of the hill of vision, however, causing the pattern standard deviation to be 2.92 db, a value found in less than 2% of the normal population. The patient was informed that a small region of the superior visual field demonstrates characteristic visual field loss from glaucoma. Figure 1B presents the bilateral Cirrus HD-OCT (Carl Zeiss Meditec, Inc.) optic nerve head (ONH) and retinal nerve fiber layer (RNFL) analysis. There is a good structure-function relationship between the inferior RNFL defect and the superior scotoma. Interestingly, the superior RNFL defect is not accompanied by an inferior perimetric deficit, indicating that a region of preperimetric neuropathy has been detected by the sensitive optical coherence tomography RNFL deviation map. 1. Asman P, Heijl A. Glaucoma hemifield test. Automated visual field evaluation. Arch Ophthalmol. 1992;110:812-819. 2. Keltner JL, Johnson CA, Quigg JM, et al. Confirmation of visual field abnormalities in the Ocular Hypertension Treatment Study. Ocular Hypertension Treatment Study Group. Arch Ophthalmol. 2000;118(9):1187-1194. Case No. 2 Moderate Glaucomatous Field Loss Figure 2A shows the results of SITA Standard testing for a 26-year-old man with juvenile primary open-angle glaucoma. The fixation losses and the false positive and false negative errors are all within acceptable limits. The gaze tracker demonstrates steady fixation with a brief period of unstable gaze about three-quarters of the way through the test. The GHT is outside normal limits. The total deviation plot reveals a paracentral superior arcuate scotoma with a more peripheral inferior arcuate scotoma, each respecting the horizontal meridian. Although a dense paracentral focal defect is present, the central visual acuity is unaffected, as reflected by the patient s 20/15 visual acuity and by the normal foveal sensitivity value of 41 db. The presence of superior and inferior hemifield defects in addition to the paracentral vision loss would place this visual loss in the moderate category, despite the seeming- Figure 2A. HFA Single Field Analysis. Figure 2B. Cirrus HD-OCT ONH and RNFL OU analysis. WINTER 2011 I SUPPLEMENT TO GLAUCOMA TODAY I 5

21st Century Visual Field Testing ly high VFI value of 90%. The mean deviation is abnormal but still modest at -3.14 db, but it is smaller than the pattern standard deviation at 5.99 db, likely because the dense superior paracentral scotoma has distorted the shape of the hill of vision. The patient was informed that there is damage to both the superior and inferior visual field and that the superior damage is approaching his central vision and must be carefully monitored. A strong structure-function relationship is seen on comparison with the Cirrus HD-OCT (Figure 2B). Case No. 3 Advanced Glaucoma A 64-year-old woman presented with blurred vision in her left eye and was found to have both cataract and glaucoma in this eye. Her visual acuity was 20/50 and could not be improved with refraction. The reliable HFA 24-2 demonstrated both superior and inferior arcuate scotomata that involved her central field, with the GHT outside normal limits. Of greatest concern was the total deviation plot demonstrating four depressed points surrounding fixation along with the foveal sensitivity value of 22 db (a value found in less than 0.5% of the normal population). The mean deviation was -7.78 db, and the pattern standard deviation was 10.57 db. The VFI is 65% in this case, and it is notable that, in this particular patient, the majority of the visual loss has occurred in the central visual field. To further investigate the central field, a central 10-2 threshold test was performed, which revealed a small central/temporal island of remaining vision. The SITA Standard strategy and stimulus size III were chosen in order to take advantage of the normative database that allows us to review the total and pattern deviation plots. Although the total deviation plot might seem to leave open the possibility of preserved fixation, the reduced foveal sensitivity on both examinations strongly suggests that the patient s visual acuity was reduced from glaucoma. In this clinician s experience, it is unlikely that glaucoma patients with reduced foveal sensitivity will regain normal visual acuity Figure 3A. HFA Single Field Analysis 24-2. Figure 3B. HFA Single Field Analysis 10-2. 6 I SUPPLEMENT TO GLAUCOMA TODAY I WINTER 2011

The Evolution Continues after cataract extraction. Although this does not always preclude cataract extraction, this finding can provide valuable insight and may help manage expected outcomes in advanced glaucoma. The patient was informed that significant visual field loss, most likely from glaucoma, was affecting her central vision. Nathan M. Radcliffe, MD, is the director of the glaucoma service and an assistant professor of ophthalmology at Weill Cornell Medical College, New York-Presbyterian Hospital, New York. He has served on the speaker s bureau for Carl Zeiss Meditec, Inc. Dr. Radcliffe may be reached at (646) 962-2020; drradcliffe@gmail.com. THE SINGLE FIELD ANALYSIS PRINTOUT The Single Field Analysis presents the results of a single central threshold test. The top of the page presents patient data, test reliability indices, and test results in the grayscale and numeric formats. The information that STATPAC adds is found in the lower half of the page. A Glaucoma Hemifield Test B Total Deviation Plots C Pattern Deviation Plots D Global Indices (VFI, MD, PSD) HFA II-i GUIDED PROGRESSION ANALYSIS (GPA) SUMMARY REPORT The new GPA Summary Report for the HFA II-i provides a concise overview of a patient s entire visual field history on a single page. A Baseline Exams: Establish initial visual field status. B VFI Rate of Progression Analysis: Trend analysis of the patient s overall visual field history. C Current Visual Field Summary: Complete report of current visual field including VFI, MD, PSD, the Progression Analysis Plot and the GPA alert. { A { B 1 2 3 { B C 1 4 D A C 1). VFI Value A summary measurement of the patient s visual field status, expressed as a percent of a normal age-adjusted visual field. 2). VFI Plot Regression analysis of VFI values and 3 to 5 year projection. 3). VFI Bar A graphical depiction of the patient s remaining useful vision at the current VFI value along with a 3 to 5 year projection of the VFI regression line if the current trend continues. 4). GPA Alert A message that indicates whether statistically significant deterioration was noted in consecutive tests. WINTER 2011 I SUPPLEMENT TO GLAUCOMA TODAY I 7

21st Century Visual Field Testing Thank you... to all our Humphrey Field Analyzer (HFA) customers for almost 3 decades of dedication in helping us innovate the most widely used visual field platform. With your support, HFA is now recognized as a standard of care, with approximately 62,000 HFAs shipped across the world. Whether you joined us in 1984 or anywhere along the journey to today with offerings such as the new Visual Field Index (VFI), the enhanced Guided Progression Analysis, and the recently launched world s first Optical Coherence Tomography and Visual Field Combined Report*, we know that, without your support, it would have been impossible to have accomplished these advances. Your choice of an HFA made it possible for us to grow and to continue to improve and expand the HFA s capabilities. We celebrate your partnership and extend our sincere thanks for your business. HFA-Cirrus Combined Report *The HFA-Cirrus Combined Report is available on the FORUM Eye Care Data Management system. VFI Plot Sincerely, The Perimetry Team at Carl Zeiss Meditec The Evolution of Innovation - Humphrey Field Analyzer 1984 HFA I 1988 HFA I, STATPAC Plus 1991 FASTPAC 1994 HFA II, Gaze tracking 2001 HFA IIi 2003 Glaucoma Progression Analysis 2010 HFA-Cirrus Combined Report 1984 2010 1986 HFA I, STATPAC 1 1989 STATPAC 2, Kinetic 1993 SWAP 1997 SITA 2002 HFA II SITA SWAP 2007 Guided Progression Analysis, VFI GLA.3384 0111