PRIMUS 200 from ZEISS The essential OCT

Similar documents
PRIMUS 200 from ZEISS The essential OCT

Cirrus TM HD-OCT. Details define your decisions

Cirrus TM HD-OCT. Details defi ne your decisions

Evolving glaucoma management True diagnostic integration for the preservation of vision

PLEX Elite 9000 from ZEISS Swept-Source OCT

ZEISS AngioPlex OCT Angiography Making the revolutionary, routine.

Deeper visualizations for intervening with confidence.

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Moving forward with a different perspective

Structural examina.on: Imaging

SOCT Copernicus REVO. * - Currently import and overlay are avaibale in manual mode only

The Measure of Confidence

Mark Dunbar: Disclosure

The World s fastest OCT. As simple as pressing. the start button

HOCT-1I 1F All-in-One Optical Coherence Tomography with Fundus

Advances in OCT Murray Fingeret, OD

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

The ideal tool for early detection and monitoring of AMD.

Visualize. Analyze. Personalize. OCT + OCTA

Introducing ANGIOVUE ESSENTIAL. Built on the Avanti Widefield OCT Platform. OCT Angiography for Primary Eye Care

The only measure of RNFL Integrity: GDxPRO

Visualize. Analyze. Personalize. OCT + OCTA. with

R&M Solutions

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

Optical Coherence Tomography (OCT)

The New Frontier of Microperimetry

The New Frontier of Microperimetry

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

The Evolution of Fundus Perimetry

ZEISS AngioPlex OCT Angiography. Clinical Case Reports

Ganglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD

tracking progression we can better manage our patients. Like any tool, any instrument you ve got to

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

VisuMax from ZEISS Defining the pulse rate in refractive surgery

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

DRI OCT Triton Series A Multimodal Swept Source OCT

How to Be Efficient and Effective. Disclosure. Topics CASE CM. Case JF 2007 OHTN / POAG? How to Be Efficient and Effective with. with New Technology

The only measure of RNFL Integrity : GDxPRO

Optical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)

OCT Image Analysis System for Grading and Diagnosis of Retinal Diseases and its Integration in i-hospital

Course # Getting to Know Your OCT

Experience Spectacular Retinal Imaging with the new NIDEK F-10 Digital Ophthalmoscope

Lasers and Imaging PHOTOCOAGULATION PHOTODISRUPTION SLT PHOTOREGENERATION DIAGNOSTIC ULTRASOUND

Ultrahigh Speed Imaging of the Rat Retina Using Ultrahigh Resolution Spectral/Fourier Domain OCT

Ganglion cell complex scan in the early prediction of glaucoma

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

Navigated Laser Therapy. A New Era in Retinal Disease Management

Lasers and Imaging PHOTOCOAGULATION PHOTODISRUPTION SLT PHOTOREGENERATION DIAGNOSTIC ULTRASOUND

Choroidal Mapping; a Novel Approach for Evaluating Choroidal Thickness and Volume

OtticaFisiopatologica

Linking structure and function in glaucoma

Do You See What I See!!! Shane R. Kannarr, OD

Peripapillary Retinal Thickness. Maps in the Evaluation of Glaucoma Patients: A Novel Concept.

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Multi-spot laser coagulation with the VISULAS 532s VITE : A comparative study of 101 procedures

CLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

CLINICAL SCIENCES. Repeatability and Reproducibility of Fast Macular Thickness Mapping With Stratus Optical Coherence Tomography

Research Article Comparison of Central Macular Thickness Measured by Three OCT Models and Study of Interoperator Variability

Optical Coherence Tomography in Diabetic Retinopathy. Mrs Samantha Mann Consultant Ophthalmologist Clinical Lead of SEL-DESP

Fundus Autofluorescence. Jonathan A. Micieli, MD Valérie Biousse, MD

EasyScan: Smart Retinal Imaging

SOUTH-EAST EUROPEAN JOURNAL of OPHTHALMOLOGY 2015; 1 (1) 34 40

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Widefield Retinal Imaging with Auto Fluorescence Technology in the Optometric Practice

Analysis of Peripapillary Atrophy Using Spectral Domain Optical Coherence Tomography

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

OCT in the Diagnosis and Follow-up of Glaucoma

Corporate Medical Policy

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Research Article Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography

New Technologies in Glaucoma Management: From ERG to OCT

Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography

The Common Clinical Competency Framework for Non-medical Ophthalmic Healthcare Professionals in Secondary Care

FORUM Glaucoma Workplace from ZEISS Clinical Interpretation Guide

Optical Coherence Tomography: Pearls for the Anterior Segment Surgeon Basic Science Michael Stewart, M.D.

Learn Connect Succeed. JCAHPO Regional Meetings 2016

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

RETINAL NERVE FIBER LAYER

NIH Public Access Author Manuscript Br J Ophthalmol. Author manuscript; available in PMC 2010 April 29.

Ophthalmic Imager Role

Local Coverage Determination (LCD): Scanning Computerized Ophthalmic Diagnostic Imaging (SCODI) (L34431)

Diabetic retinopathy accounts for much of the visual impairment

Lasers and Imaging PHOTOCOAGULATION PHOTODISRUPTION SLT PHOTOREGENERATION DIAGNOSTIC ULTRASOUND

Overview. Macular OCT Artifact Study

What Is O.C.T. and Why Should I Give A Rip? OCT & Me How Optical Coherence Tomography Changed the Life of a Small Town Optometrist 5/19/2014

History/principles of the OCT What does the normal retinal OCT look like Vitreal disorders Retinal/RPE disorders Choroidal disorders

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Comparison of Spectral/Fourier Domain Optical Coherence Tomography Instruments for Assessment of Normal Macular Thickness

International Journal of Advance Engineering and Research Development EARLY DETECTION OF GLAUCOMA USING EMPIRICAL WAVELET TRANSFORM

Study of clinical significance of optical coherence tomography in diagnosis & management of diabetic macular edema

Yasser R. Serag, MD Tamer Wasfi, MD El- Saied El-Dessoukey, MD Magdi S. Moussa, MD Anselm Kampik, MD

3/23/2016. Diagnostic Services Taylor Pannell CRA, OCT-C. Services Available. Important info for the Tech to know. Visual Fields

Clinical Study Choroidal Thickness in Eyes with Unilateral Ocular Ischemic Syndrome

and at the same patient encounter. Code has been deleted. For scanning computerized ophthalmic diagnostic imaging of optic nerve and retin

IN NICU OCT UTILIZES A CONCEPT KNOWN AS INTERFEROMETRY APPLICATIONS FOR OCT THE PRIMARY USE IN THE EYE - RETINA

Five Things You re Missing with Your Fundus Camera

Science & Technologies

Exceptional versatility without compromise

The Common Clinical Competency Framework for Non-medical Ophthalmic Healthcare Professionals in Secondary Care

Optical Coherence Tomography 3D OCT-1 Maestro

Transcription:

EN 00_00I The contents of the brochure may differ from the current status of approval of the product in your country. Please contact your regional representative for more information. Subject to change in design and scope of delivery and as a result of ongoing technical development. CIRRUS, Selective Pixel Profiling, AutoCenter, and FoveaFinder are either registered trademarks or trademarks of Carl Zeiss Meditec AG or of other companies of the ZEISS Group in Germany and/or in other countries. 05 by Carl Zeiss Meditec, Inc. All copyrights reserved. 0.65 by 7.8779 Page Size Today, OCT is essential for the daily practice of quality eye care You cannot treat what you cannot see. Today, OCT makes ocular anatomy visible in ways never available before so you can see more and treat more. With ZEISS PRIMUS 00, you can join doctors around the world who have placed their trust in ZEISS, the pioneer in ophthalmic OCT, as their OCT partner. With ZEISS, you can enjoy the support of the extensive ZEISS global service network and rapid response technologies including remote diagnostics to ensure your OCT is performing at its best. Today, you can confidently invest in your practice with the certainty that comes with the all new essential OCT from ZEISS: PRIMUS 00. Carl Zeiss Suzhou Co. Ltd. Carl Zeiss Meditec, Inc. Carl Zeiss Meditec AG Modern Industrial Square -B No. Xing Pu Road, Suzhou Industrial Park, Suzhou China 56 560 Hacienda Drive Dublin, CA 9568 USA Toll-Free: + 800 6968 Phone: + 95 557 00 Fax: + 95 557 0 www.zeiss.com/med Goeschwitzer Str. 5-5 0775 Jena GERMANY Phone: +86 5 687 88 Fax: +86 5 687 5 Phone: +9 6 0 Fax: +9 6 0 www.zeiss.com/med PRIMUS 00 from ZEISS The essential OCT

Clear Visualization. Advanced Technology. Reliability. Essential elements of your first OCT. Reveal the hidden structures in the retina with the new PRIMUS 00 from ZEISS, the pioneer in ophthalmic OCT. Ideal for small practices, PRIMUS 00 delivers the essential clinical applications to help you manage your patients with certainty. ZEISS PRIMUS 00 is the technology engine with the power and performance you need to deliver the optimal level of clinical care and to grow your practice. See beyond the surface Today, optical coherence tomography (OCT) has become as essential to clinical eye care as perimetry or fundus photography. OCT gives clinical insight to better understand your patient s condition and the power to manage a broader range of pathologies within your practice. By incorporating legendary ZEISS optics and proprietary algorithms, in a compact and intuitive design, the ZEISS PRIMUS 00 is both a diagnostic and a patient education tool as it helps you to effectively communicate the essential aspects of a comprehensive treatment plan.

Vitreomacular traction syndrome (VMT) Clearer images for deeper insight ZEISS PRIMUS 00 inherits the fundamental quality of world-class ZEISS optics, providing you with clear and compelling OCT and fundus images to help you detect pathologies at the earliest possible moment. High definition B-scans With high SNR (Signal-to-Noise Ratio) and extended integration time, PRIMUS 00 reveals micro-structural details that are critical to effectively manage a broad range of diseases. Selective Pixel ProfilingTM ensures brilliant, high-definition imaging across the B-Scan for accurate diagnostic insights and assured treatment decision making. Clear fundus images Confocal Scanning Laser Ophthalmoscopy (cslo) technology is used to display high-quality fundus images. Clear, sharp fundus images are essential to accurately correlate the B-scans and corresponding fundus image. Central retinal venous occulusion (CRVO) with cystoid macula edema (CME) and subfoveal fluid Age-related macular degeneration (AMD) 5

Simplicity through smart workflow ZEISS PRIMUS 00 utilizes a simple -step process for capturing all anterior and posterior segment scans. This optimized workflow helps to increase operator efficiency while minimizing patient chair time.. Select Report-driven workflow Enables selection of desired reports and automatically sequences the required scan-protocols for acquisition.. Capture Ease of use through an intuitive design System-guided navigation Easy acquisition protocols prompt and lead you through all selected scans.. Review With its simple and sleek, yet sturdy design, ZEISS PRIMUS 00 offers you a clear view of the patient during scan acquisition. 6 Familiar slit-lamp-style joystick allows you to align and capture images with ease. Pre-selected reports Analyses are automatically prepared for you to scan and select with the click of a button. 7

// RETINA ASSESSMENT // GLAUCOMA MANAGEMENT Visualize. Assess. Act. With clear visualization of cross-sectional retinal layers and ZEISS-proven algorithms, ZEISS PRIMUS 00 enables you to make qualitative and quantitative assessments of your patient s retinal condition. Visualize the retina with high definition and 5 Line HD B-scans and measure macular abnormalities using Macular Thickness Analysis. Determine your next steps with confidence. Identify. Monitor. Manage. Identify and monitor at-risk patients for glaucoma with the comprehensive optic nerve and retinal nerve fiber layer (ONH and RNFL) reports. Easy-to-understand graphics can serve as teaching tools for patients and can help improve compliance for better disease management. 5 ETDRS measurement grid with normative data colors uses the Auto FoveaFinder TM to automatically and accurately locate the fovea, providing precise macular thickness values for each visit. Horizontal and vertical B-scans are extracted from the data cube through the center of the disc. RPE layer and disc boundaries are shown in black. ILM and cup boundaries are shown in red. Clear fundus image with options to overlay ILM-RPE thickness map or move the ETDRS to desired foveal location. OCT fundus image of the Optic Nerve Head with AutoCenter TM automatically centers the Optic Disc and RNFL circle. Large B-scan display in color or greyscale helps both with visualizing pathologies quickly and with improving patient communication. Enter or choose from predefined comments for patient report. RNFL thickness map is a topographical display of RNFL thickness. RNFL and Neuro-retinal Rim Thickness are shown in TSNIT graphs. Other key parameters are displayed in a table format with normative data colors. 5 RNFL Quadrant displays patient s RNFL average thickness in each quadrant along the calculation circle with superior and inferior normative data colors. 8 9

// ANTERIOR SEGMENT IMAGING Observe. Unveil. Clarify. The ZEISS PRIMUS 00 delivers anterior segment imaging to visualize the fi ne details of the cornea and angles in a fresh and intuitive dimension, providing new clarity for your assessment and for your patient s understanding of their condition. Visualize a clear image of the cornea, iris and sclera, along with the scan-line location. Single-line, high-defi nition angle view B-scan using the Selective Pixel Profi ling TM algorithm. Single-line, high-defi nition cornea B-scan with identifi able epithelium, Bowman s membrane and stroma. 0

The moment you see beyond the surface. This is the moment we work for. Technical Specification OCT imaging Methodology Spectral Domain OCT Optical source Super Luminescent Diode (SLD), 80 nm A-scan depth.0 mm (in tissue), 0 Points Axial resolution 5± μm (in Tissue) Transverse resolution 0 μm (in Tissue, FWHM) Fundus imaging Methodology Confocal Scanning Laser Ophthalmoscopy (cslo) Live fundus image During alignment Optical source Super Luminescent Diode (SLD), 80 nm Field of view 9º H x º V Transverse resolution 80 μm (in Tissue) Scan Reports Retina analysis Macular thickness using Auto FoveaFinder 5 Line raster with adjustable orientation Line HD with adjustable orientation Glaucoma analysis ONH and RNFL analysis using AutoCenter Anterior segment Angle view Cornea view Electrical and physical Weight 0 kg (88 lbs) Dimensions of instrument 0L x 80W x 50H (cm) Fixation Internal, External Internal fixation focus adjustment -D to +7D (Diopters) Pupil Size requirement > mm Internal Computer Operating system / processor Windows 7/Intel Core i-0e Memory GB Hard drive / internal storage 500GB/.5inch Display (resolution: 66 x 768) USB ports ports Ethernet ports ports, 0/00 with independent IP address Technical specifications are subject to change. // INSIGHT MADE BY ZEISS