Myocardial Blood Flow from Dynamic PET using Independent Component Analysis

Similar documents
Effects of Motion and Tissue Weighting on PET Myocardial Blood Flow Estimates

Photon Attenuation Correction in Misregistered Cardiac PET/CT

Biases affecting tumor uptake measurements in FDG-PET

Tumor cut segmentation for Blemish Cells Detection in Human Brain Based on Cellular Automata

Reproducibility of Uptake Estimates in FDG PET: a Monte Carlo study

ECG Beat Recognition using Principal Components Analysis and Artificial Neural Network

On the feasibility of speckle reduction in echocardiography using strain compounding

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

Animals. Male C57Bl/6 mice (n=27) were obtained from Charles River (Sulzfeld, Germany) and

Normal LV Ejection Fraction Limits Using 4D-MSPECT: Comparisons of Gated Perfusion and Gated Blood Pool SPECT Data with Planar Blood Pool

OPTIMIZATION OF Rb-82 PET ACQUISITION AND RECONSTRUCTION PROTOCOLS FOR MYOCARDIAL PERFUSION DEFECT DETECTION

Modifi ed CT perfusion contrast injection protocols for improved CBF quantifi cation with lower temporal sampling

Group-Wise FMRI Activation Detection on Corresponding Cortical Landmarks

Automatic Hemorrhage Classification System Based On Svm Classifier

Comparison between 1-compartmental and 2-compartmental model in calculation of myocardium blood flow in 82 Rb PET imaging

NMF-Density: NMF-Based Breast Density Classifier

Supplementary Information Methods Subjects The study was comprised of 84 chronic pain patients with either chronic back pain (CBP) or osteoarthritis

Although qualitative perfusion SPECT provides valuable

Nature Neuroscience: doi: /nn Supplementary Figure 1. Behavioral training.

Uptake of 18 F-FDG in malignant tumors is subject to

Typical PET Image. Elevated uptake of FDG (related to metabolism) Lung cancer example: But where exactly is it located?

Detection Of Functional Significance of Coronary Stenoses Using Dynamic. Values Of Myocardial Blood Flow And Coronary Flow Reserve

Functional Elements and Networks in fmri

International Journal of Engineering Trends and Applications (IJETA) Volume 4 Issue 2, Mar-Apr 2017

Effective Diagnosis of Alzheimer s Disease by means of Association Rules

MRI Image Processing Operations for Brain Tumor Detection

Precision and accuracy of clinical quantification of myocardial blood flow by dynamic PET: a technical perspective

Metabolic volume measurement (physics and methods)

I. INTRODUCTION DYNAMIC positron emission tomography (PET) scans

PCA Enhanced Kalman Filter for ECG Denoising

Bayesian Bi-Cluster Change-Point Model for Exploring Functional Brain Dynamics

DATA MANAGEMENT & TYPES OF ANALYSES OFTEN USED. Dennis L. Molfese University of Nebraska - Lincoln

LEFT VENTRICLE SEGMENTATION AND MEASUREMENT Using Analyze

Contributions to Brain MRI Processing and Analysis

Copyright 2008 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 6915, Medical Imaging 2008:

Prediction of Successful Memory Encoding from fmri Data

NIH Public Access Author Manuscript Mol Imaging Biol. Author manuscript; available in PMC 2011 April 1.

Supplementary Online Content

A numerical 3D coronary tree model

Early Learning vs Early Variability 1.5 r = p = Early Learning r = p = e 005. Early Learning 0.

Automatic cardiac contour propagation in short axis cardiac MR images

A Survey on Brain Tumor Detection Technique

Multichannel Classification of Single EEG Trials with Independent Component Analysis

Edge Detection Techniques Using Fuzzy Logic

Overview. Connectivity detection

1 Introduction. Abstract: Accurate optic disc (OD) segmentation and fovea. Keywords: optic disc segmentation, fovea detection.

Enhanced Endocardial Boundary Detection in Echocardiography Images using B-Spline and Statistical Method

Classification of ECG Data for Predictive Analysis to Assist in Medical Decisions.

Accepted Manuscript. Identification of Exercise-Induced Ischemia using QRS Slopes. Reza Firoozabadi, Richard E. Gregg, Saeed Babaeizadeh

Ø We used a standard dose of 5 instead of 3 mci in order to ensure optimal signal to noise in the data

An ECG Beat Classification Using Adaptive Neuro- Fuzzy Inference System

LUNG CANCER continues to rank as the leading cause

THE data used in this project is provided. SEIZURE forecasting systems hold promise. Seizure Prediction from Intracranial EEG Recordings

PET in Radiation Therapy. Outline. Tumor Segmentation in PET and in Multimodality Images for Radiation Therapy. 1. Tumor segmentation in PET

arxiv: v2 [cs.cv] 8 Mar 2018

Cancer Cells Detection using OTSU Threshold Algorithm

Cronfa - Swansea University Open Access Repository

Frequency Tracking: LMS and RLS Applied to Speech Formant Estimation

Comparative Study of K-means, Gaussian Mixture Model, Fuzzy C-means algorithms for Brain Tumor Segmentation

Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance

Proceedings of the UGC Sponsored National Conference on Advanced Networking and Applications, 27 th March 2015

LUNG NODULE DETECTION SYSTEM

Precision of pre-sirt predictive dosimetry

Experimental Assessment of Infarct Lesion Growth in Mice using Time-Resolved T2* MR Image Sequences

Qualitative and Quantitative Assessment of Perfusion

Restoration Analysis of Various Type of MRI Brain Tumor Using Blind De-Convolution Pre-Processing Technique

Feasibility of a New C-arm angiography (DYNA-CT) based three-dimensional algorithm in combination with myocardial perfusion assessment

Segmentation of Tumor Region from Brain Mri Images Using Fuzzy C-Means Clustering And Seeded Region Growing

Classification and Statistical Analysis of Auditory FMRI Data Using Linear Discriminative Analysis and Quadratic Discriminative Analysis

A New Approach For an Improved Multiple Brain Lesion Segmentation

Brain Tumour Diagnostic Support Based on Medical Image Segmentation

Final Report: Automated Semantic Segmentation of Volumetric Cardiovascular Features and Disease Assessment

FREQUENCY DOMAIN BASED AUTOMATIC EKG ARTIFACT

Robust Estimation for Brain Tumor Segmentation

Previous animal and clinical studies with 15 O-water and

Detection of Glaucoma and Diabetic Retinopathy from Fundus Images by Bloodvessel Segmentation

Myocardial Twist from X-ray Angiography

PET-MRI in Cardiac Imaging: Initial Experience

Table 1. Summary of PET and fmri Methods. What is imaged PET fmri BOLD (T2*) Regional brain activation. Blood flow ( 15 O) Arterial spin tagging (AST)

DISCLOSURE. Myocardial Mechanics. Relevant Financial Relationship(s) Off Label Usage

Vital Responder: Real-time Health Monitoring of First- Responders

Assessment of cardiac function with 3D echocardiography. Đánh giá chức năng tim bằng siêu âm tim 3D

Assessing Functional Neural Connectivity as an Indicator of Cognitive Performance *

Quick detection of QRS complexes and R-waves using a wavelet transform and K-means clustering

EARLY STAGE DIAGNOSIS OF LUNG CANCER USING CT-SCAN IMAGES BASED ON CELLULAR LEARNING AUTOMATE

Cardiovascular magnetic resonance in acute myocardial infarction

arxiv: v1 [cs.lg] 4 Feb 2019

doi: /

Copyright 2007 IEEE. Reprinted from 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, April 2007.

Philips Gemini TF camera (Philips, Cleveland OH), with an 18 cm coronal and a 57 cm axial

Recognition of English Characters Using Spiking Neural Networks

LUNG NODULE SEGMENTATION IN COMPUTED TOMOGRAPHY IMAGE. Hemahashiny, Ketheesan Department of Physical Science, Vavuniya Campus

Computational Cognitive Science

Neuron, Volume 63 Spatial attention decorrelates intrinsic activity fluctuations in Macaque area V4.

Enhanced Detection of Lung Cancer using Hybrid Method of Image Segmentation

Detection of Mild Cognitive Impairment using Image Differences and Clinical Features

Fully-Automatic Determination of the Arterial Input Function for Dynamic Contrast-Enhanced Pulmonary MR Imaging (DCE-pMRI)

BRAIN STATE CHANGE DETECTION VIA FIBER-CENTERED FUNCTIONAL CONNECTIVITY ANALYSIS

Validating the Visual Saliency Model

Sum of Neurally Distinct Stimulus- and Task-Related Components.

Transcription:

2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSSIMIC) M07-4 Myocardial Blood Flow from Dynamic PET using Independent Component Analysis Alexander Karpikov, Hemant Tagare, Senior Member, IEEE, Tim Mulnix, Jean-Dominique Gallezot, Albert Sinusas, Chi Liu, Member, IEEE, and Richard E. Carson, Member, IEEE Abstract-Generation of parametric images of myocardial blood flow (MBF) from dynamic PET requires a reproducible and reliable method to obtain left and right ventricular time-activity curves. We propose the use of Independent Component Analysis (ICA) on PET temporal information to segment the image data into three categories: right ventricle (RV), left ventricle (LV) and myocardium. ICA is an established signal processing technique that assumes that the dynamic signal in each voxel is a linear mixture of signals from statistically independent sources. The mixing process is due to cardiac motion and partial volume effects. Due to its ability to find the intensity of the underlying sources, ICA generates a 3D map of the mixing coefficients that allows the segmentation of structures. Dynamic cardiac PET data were acquired with a Siemens Biograph mct PETtCT scanner using Rb-82 and [ I5 0)water in nonhuman primate and pigs with injections of different activities. The Dice similarity coefficient (DSC) was used to compare the segmentations between scans of different species with different tracers. The LV and RV regions were used to calculate input functions for kinetic analysis and MBF estimation. Pairwise comparisons of the segmentations between different [ I5 0)water PET scans gave DSC of 0.91 ± 0.09 and 0.92±0.08 for the RV and LV segmentations, respectively. For Rb-82 PET scans, the DSC values were of 0.89 ± 0.09 and 0.85±0. for RV and LV. We used contrast CT as a gold standard for the LV and RV segmentations. Pairwise comparisons of the segmentations between different contrast CT and Rb-82 PET scans gave DSC of 0.86 ± 0.09 and 0.85±0.09 for the RV and LV, respectively. Our work shows the reliability and reproducibility of the results of the segmentation algorithm. High quality parametric images of MBF and the kinetic parameters were obtained. These results suggest that ICA may be useful to extract time-activity curves for kinetic MBF analysis. The effects of partial volume on input TAC determination were also evaluated. cardiac PET data is challenging due to the higher noise level of PET data compared to CT or MR!. Independent Component Analysis (lca) is an established technique in signal processing [1]. It has been successfully applied to the blind deconvolution problem, i.e., finding the independent signals from their mixtures without knowing the mixing coefficients. Dynamic cardiac PET data provide another example of a problem of mixed signals. Signals from blood in LV and RV plus the myocardium signal are mixed due to cardiac motion and the partial volume effect. In this work, we used ICA to segment the data in order to get reproducible and reliable RV and LV T ACs for MBF analysis. ICA segments data using its temporal properties: the source corresponding to the R V is highest during the initial bolus passage through the RV. The L V source is active at a later stage when tracer enters the LV. The myocardium source has slower kinetics. For MBF calculations we used standard kinetic models [2,3] applied to nonhuman primate and pig PET data with Rb-82 and [ '5 0]water. A. Data acquisition II. METHODS Scans were performed on Biograph mct TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.). A rhesus monkey and two pigs were studied with [ '5 0]water and Rb-82. Injections of different activities were used for this study. All the scans were in the resting state to permit assessment of reproducibility. Table I summarizes the information about the scans. I. INTRODUCTION pet imaging is an important tool for studying cardiac function including myocardial blood flow (MBF). The accuracy of MBF computation depends on the accuracy of the input time-activity curves (T ACs) of the model. Accurate estimation of input curves requires careful segmentation of the left ventricle (LV) and right ventricle (RV). Segmentation of Manuscript received November 13, 2012. research contract from Siemens Medical Solutions. This work was supported by a Alexander Karpikov, Tim Mulnix, Jean-Dominique Gallezot, Chi Liu, and Richard E. Carson are with the PET center, Yale University, New Haven, CT 06520 USA Hemant Tagare is with Departments of Diagnostic Radiology and Biomedical Engineering, Yale University, New Haven, CT 06511 USA Albert Sinusas is with Departments of Internal Medicine and Diagnostic Radiology, Yale University, New Haven, CT 06520 USA Rhesus [ 15 O]water 5 no monkey Pig#l Rb-82 3 no Pig#2 Rb-82 3 yes [ 15 O]water 2 PET data were acquired in list mode format and reconstructed using Siemens TrueX reconstruction algorithm, a 3D PSF ordinary-poisson ordered-subset-expectationmaximization reconstruction algorithm [4] with TOF. Parameters for the reconstruction were 3 iterations and 21 subsets with 2x2x2 mm voxels. The frame duration for the dynamic PET reconstruction was 3s. The time interval 978-1-4673-2030-6/12/$3l.00 2012 IEEE 2222

between adjacent frames was Is, i.e., with overlapping frames to increase temporal sampling. Contrast CT scan was acquired for Pig #2. B. lca Algorithm For a dataset with m voxels and n time points, consider a linear mixture of k independent components (here k=3), which can be written as a matrix product: x = As (1) where x is the mxn data matrix, each row corresponding to a time point of a particular voxel. s is a kxn matrix, with each row being a source vector corresponding to the T AC of each component. A is the mixing matrix (mxk) which has only spatial dependency (See Fig. 1). ICA considers the distribution of the radioactivity values (ignoring their order) and assumes that components are statistically independent and have non Gaussian distribution. This assumption allows ICA to estimate A as well as s. For further theoretical discussions of ICA as well as different numerical implementation, please refer to [1]. We used Fast ICA [5], an algorithm based on a fixed-point iteration scheme maximizing non-gaussianity (skewness) of the distribution of the source vectors as a measure of statistical independence. As a standard step of Fast ICA data preprocessing (whitening) the dimensionality of the data was reduced by applying PCA and keeping only first seven PCA eigenvalues..:...- + # of components (k=3) l m time points DSC=o DSC<l DSC=l Fig. 2. Schematic depiction of Dice similarity coefficient (DSC). B. Parametric image model The 4-parameter kinetic model for Rb-82 data was applied pixel-by-pixel with the LV input function and 2 spill-in terms [2]: CT(t) = Kl * CA(t)<iS>exp (-k2 * t) + VACA(t) + VRVCRV(t) (3) where CT is the tissue activity, Kl is the myocardium inflow, kz is the myocardial tissue egress (outflow), and CA(t) and CRV(t) are the arterial (LV) and RV TACs, respectively. An example ofca(t) and CRV(t) curves is shown in Fig. 3. A Similar 4-parameter kinetic model is used for [ 15 0]water data [3]: CT(t) = MBF * PTF * CA(t) * exp <is> (-MBF * :J + VACA(t) + VRVCRV(t) (4) where V T is volume of distribution or partition coefficient of water (VT=O.91), and PTF is the perfusible tissue fraction. 6 x 5 5 2 Fig. 1. Schematic representation of ICA algorithm. A. lca III. ANALYSIS Fast ICA was applied to the [ '5 0]water and Rb-82 cardiac PET data. The number of independent components was chosen to be three (RV, LV, and myocardium). The Dice similarity coefficient (DSC) [6] was used to compare the consistency of the segmentations across scans of different injections: DSC = 2 B n Y (2) B+Y where B (blue) and Y (yellow) are two segmentations represented by their voxel locations, n is the intersection of two regions and + is the sum of two regions (Fig. 2). DSC takes values between zero and one and is equal to one for two identical segmentations. sec Fig. 3. An example of CA(t) and CRV(t) curves estimated from lcaderived regions from a pig study Both CA (t) and CRV(t) curves have highly non-gaussian distribution functions. This is demonstrated by the long-tailed histogram of CRV(t) shown in Fig. 4. ICA was thus expected to be an effective algorithm for defining LV and RV regions, since it finds independent components by maximizing non Gaussianity of each source. 2223

sec the myocardial region are included in the kinetic model. Mathematically, this idea can be expressed as: CA(t)=aCA true(t)+ (I-a) C m (t) (5) Fig. 4. An example of CRV(t) curve (left panel) and its histogram (right panel) showing a non-gaussian distribution. ICA gives the mixing matrix A (mx3) as its output. The three components correspond to RV, LV or myocardium as shown in Fig. 5. By identifying the component corresponding to the L V and choosing only pixels with component scores above a certain threshold, we obtain the mask region to derive the LV input curve. The same procedure is applied for the RV curve. The thresholds were chosen in consistent way such that the volumes for RL and VL are the same for across the runs. This is used to compare the consistency of the segmentations. The numerical value of the thresholds was chosen based on the visual assessment of the shape of the regions and input curves derived from those regions. where the measured arterial input function CA(t) is contaminated by spill-in from the myocardium, i.e., the measurement is the linear combination of the true arterial function CA true and the myocardium signal C m. The situation when a=o corresponds to no partial volume effect (zero bias). Simulations were performed using experimentally measured input curves from Rb-82 and [ 15 0]water scans. These input curves were obtained by using a very stringent threshold for the ICA mixing matrix giving LV ROIs which suffer minimal partial volume effect. C m was modeled using typical kinetic parameters for the myocardium. For a given value of a, the biased LV curve was calculated with Eq. 5, the model fitting was applied, and the percent bias in the kinetic parameters was determined. IV. RESULTS AND DISCUSSIONS In these initial data, reliable segmentation of tissues with different T ACs was achieved with ICA. Pairwise comparisons of the segmentations between different PET scans gave high values of DSC, as shown in Table II. Rhesus C5O]water 0.91 ± 0.09 0.92±0.08 monkey (5 scans) Myocardium N x tat LV Pig#1 Rb-82 0.89± 0.09 0.84±0.1O (3 scans) Pig#2 Rb-82 0.88 ± 0.09 0.86±0. (2 scans) [ 15 O]water (3 scans) Fig. 5. Application oftca for RV and LV segmentation. Images on the bottom are the lca-derived component maps A basis function implementation of weighted least squares minimization was used to fit the voxel T ACs to the kinetic models. Noise equivalent counts (NEC) were used as weights. The model produces parametric images of VRV, VA' PTF and MBF. We investigated the influence of the partial volume effect on the kinetic model parameters. Specifically, the simulation concerned the bias in the LV and RV curves measured in the vicinity of the myocardium, since the partial volume effects of Fig. 6 shows examples of high quality parametric images of MBF, PTF, VA and VRV from [ '5 0]water in the rhesus monkey. Gaussian smoothing (FWHM= 3.5 mm) was applied to the data after the fitting. The numerical values of the resulting parametric images were consistent with the literature; for example, the peak values of LV and RV volume fractions were near l.0. A more thorough quantitative evaluation of this approach is underway. 2224

reliability and accuracy vs. arterial input function measurements. Fig. 8. Choice of ROI (Pig #2 data) for the [ACt) input curve (left panel) and the corresponding input curves (right panel). Fig. 6. Examples of parametric images from [ '; O]water in the rhesus monkey! Top left: MBF (myocardial blood flow) [ml/(min. cm l )]. Top right: PTF (perfusible tissue fraction). Bottom left: VRV (Right ventricle blood volume). Bottom right: V A (Left ventricle arterial blood volume). V A and V RV are the spill-in coefficients for the myocardium. MBF and PTF images were filtered based on the myocardium segmentation obtained using ICA. In one pig study, we used contrast CT as a gold standard for the LV and R V segmentations. See Fig. 7 for the comparison of contrast CT and [ 15 0]water scan. The thresholds for CT and PET segmentations were chosen in consistent way such that the volumes for RL and VL are the same across CT and PET segmentations. Pairwise comparisons of the segmentations between different contrast CT and Rb-82 PET scans gave DSC of 0.86 ± 0.09 for the RV segmentations and 0.85±0.09 for the L V segmentations. Fig. 9 shows the results of simulation studies for partial volume effect described by Eq. 5. The graph displays the bias introduced by partial volume effects. We can clearly see that the partial volume effect become more pronounced with increasing ex, i.e., increasing LV ROI size. Based on the substantial magnitude of these biases, careful selection of the region, i.e., careful selection of the ICA threshold, will be important for accurate kinetic parameter estimation. V. SUMMARY AND FUTURE WORK Based on these initial data, our work demonstrates the reliability and reproducibility of segmenting LV and RV structures using ICA. Since this technique was used in 2 species and with 2 tracers, it suggests that ICA may be a highly robust approach to extract regions for voxel-by-voxel measurement of myocardial blood flow with PET. Our future work will include optimization of the thresholding procedure for RV and LV segmentation to control the partial volume effect. In addition, comparisons of Rb-82 and [ 15 0]water MBF measurements will be performed in animal and human studies. We will also validate MBF computations in animal scans with microspheres experiments. RB-82 Fig. 7. Contrast CT for Pig #2 averaged over one cycle (left panel). [ I5 O]water scan for the same pig averaged over 40 sec after the injection (right panel). An important step in this evaluation includes the optimization of thresholding of the LV and RV ICA-derived components to produce the respective TACs. Fig. 8 displays the change in the LV input curve corresponding to changes in ROI used to derive it. MBF clearly depends on the choice of the ROI used to derive the LV input function. Specifically, the use of LV input function derived from larger ROls would bias the LV T AC, underestimating the activity at early times and possibly overestimating it at later times, if the myocardial activity exceeds that in the blood pool. Ultimately, MBF values using ICA-derived T ACs will be assessed for test/retest 25 20 :- 30! 15...0«20 '::Jt:'- > 50 0 0 0.1 0.2 0.3 0.1 0.2 0.3 40 [150]water 50 40 - *" 40 j 30 g 30 20 :0 " > <1: 20 0.1 0.2 0.3 0 0 0.1 0.2 0.3 Fig. 9. Kinetic coefficients bias due to the partial volume effect in the LV region for Rb-82 (top) and [ I5 O]water (bottom). The term a defines the magnitude of the partial volume effect. 2225

ACKNOWLEDGMENT We thank Zhongdong Sun for programming support and the staff of the Yale PET Center for the studies that formed the basis of this work. This work was sponsored by a grant from Siemens Medical Systems. [I] REFERENCES A. Hyvarinen, J. Karhunen, and E. Oja, Independent component analysis. New York: J. Wiley, 2001. [2] G. EI Fakhri, A. Sitek, B. Guerin, M. F. Kijewski, M. F. Oi Carli, and S. C. Moore, "Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses," JNM, vol. 46, pp 1264-1271, May 2005. [3] H. J. Harms, P. Knaapen, S. de Haan, R. Halbmeijer, A. A. Lammertsma, and M. Lubberink, "Automatic generation of absolute myocardial blood flow images using [O-15]H20 and a clinical PETICT scanner," European Journal of Nuclear Medicine and Molecular imaging, vol. 38, pp. 930-939, May 2011. [4] V. Y. Panin, F. Kehren, C. Michel, and M. Casey, "Fully 3-0 PET reconstruction with system matrix derived from point source measurements," Ieee Transactions on Medical imaging, vol. 25, pp. 907-921, Jul 2006. [5] A. Hyvarinen, "Fast and robust fixed-point algorithms for independent component analysis," Ieee Transactions on Neural Networks, vol., pp. 626-634, May 1999. [6] K. H. Zou, S. K. Warfield, A. Bharatha, C. M. C. Tempany, M. R. Kaus, S. 1. Haker, W. M. Wells, F. A. Jolesz, and R. Kikinis, "Statistical validation of image segmentation quality based on a spatial overlap index - Scientific reports," Academic Radiology, vol. II, pp. 178-189, Feb 2004. 2226