Venue: IEEE NSS/MIC/RTSD Conference, Seoul, South Korea, 27 th October 2013 Workshop: NWK3/RD1 Radiation Protection and Dosimetry

Similar documents
Highlights from the Advanced Radiation Dosimetry European Network Training initiative (ARDENT) Marco Silari (CERN) on behalf of the ARDENT consortium

A short summary of ARDENT

Neutrons. ρ σ. where. Neutrons act like photons in the sense that they are attenuated as. Unlike photons, neutrons interact via the strong interaction

Neutron Induced Radiation Damage in BaF 2, LYSO and PWO Scintillation Crystals

COMPARISON OF RADIOBIOLOGICAL EFFECTS OF CARBON IONS TO PROTONS ON A RESISTANT HUMAN MELANOMA CELL LINE

Presented by Dr. Amir H. Mohagheghi. Annual RMCC Workshop Middle East Scientific Institute for Security (MESIS) Amman, Jordan June 17-19, 2013

The ANDANTE project: a multidisciplinary approach to neutron RBE

Neutron Measurements for Intensity Modulated Radiation Therapy

Nuclear Data for Radiation Therapy

nuclear science and technology

V. 4. Design and Benchmark Experiment for Cyclotron-based Neutron Source for BNCT

Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry

THERMOLUMINESCENT (TL) DOSIMETRY OF SLOW-NEUTRON FIELDS AT RADIOTHERAPY DOSE LEVEL

Neutron dose evaluation in radiotherapy

The application of 1.6 MeV proton microbeam to investigate radiation-induced bystander effect in MIA PaCa-2 pancreatic cancer cell line

HEALTH RISKS FROM EXPOSURE TO FAST NEUTRONS. Prof. Marco Durante

Improving personal dosimetry of medical staff wearing radioprotective garments: Design of a new whole-body dosimeter using Monte Carlo simulations

CALIBRATION OF A TLD ALBEDO INDIVIDUAL NEUTRON MONITOR

Recent advances in dosimetry in reference conditions for proton and light-ion beams

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

AUTHOR QUERIES - TO BE ANSWERED BY THE CORRESPONDING AUTHOR

Study on Microdosimetry for Boron Neutron Capture Therapy

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

PROGRESS IN HADRONTHERAPY


Epithermal neutron beams from the 7 Li(p,n) reaction near the threshold for neutron capture therapy

Calculated LET spectrum from antiproton beams stopping in water

nuclear science and technology

A Novel Concept and Technique for Individual Monitoring for Photon, Beta and Neutron Radiation

Neutron Interactions Part 2. Neutron shielding. Neutron shielding. George Starkschall, Ph.D. Department of Radiation Physics

IPPE Iron shell transmission experiment with 14 MeV neutron source and its analysis by the Monte-Carlo method

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

SIMULATION RESPONSE OF RESISTIVE PLATE CHAMBER FOR FAST NEUTRONS USING GEANT4 MC CODE

Proton and helium beams: the present and the future of light ion beam therapy

Figure 1.1 PHITS geometry for PTB irradiations with: broad beam, upper panel; mono energetic beams, lower panel. Pictures of the setups and of the

The impact of different radiation qualities on cancer cells

GDR in Radiotherapy Treatment Fields with 18 MV Accelerators

X-RAYS INDIVIDUAL DOSE ASSESSMENT USING TLD DOSIMETERS

THE HIGH-CURRENT DEUTERON ACCELERATOR FOR THE NEUTRON THERAPY. S.V. Akulinichev, A. V. Andreev, V.M. Skorkin

Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose

Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH A COMBINATION OF TLD ALBEDO AND SULPHUR ACTIVATION TECHNIQUES FOR FAST NEUTRON PERSONNEL DOSIMETRY

DPA calculations with FLUKA

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

EURADOS: Overview of actions and initiatives in radiation protection in medicine

Your co-operation partner for research. EUROPEAN UNION European Regional Development Fund

What is radiation quality?

Cancer Treatment by Charged Particles - Carbon Ion Radiotherapy -

III. Proton-therapytherapy. Rome SB - 5/5 1

Large-area Two-Dimensional Thermoluminescence Dosimetry System in Ion Beam Quality Assurance

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Out-of-field Radiation Risks in Paediatric Proton Therapy

HADRONTHERAPY: a new frontier for cancer treatment

Basic Press Information

Today, I will present the second of the two lectures on neutron interactions.

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Report to the 18 th Meeting of the CCRI(I), May 2007 Recent Activities in Measurement Standards and Dosimetry at METAS,

BIOLOGICAL EFFECTS OF

The SCK-CEN Activities in Neutron Dosimetry

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

Small field diode dosimetry

CIRMS: A Retrospective & Look Forward

Skin Model and its impact on Digital Mammography

Single Photon Emission Tomography Approach for Online Patient Dose Assessment in Boron Neutron Capture Therapy

Microdosimetric Relative Biological Effectiveness of Therapeutic Proton Beams. Chuan Jong Tung 1,2

Influence of Radiation Damage obtained under Fast Charged Particle Irradiation on Plasma-Facing Erosion of Fusion Structural Materials

Neutron-Gamma Mixed field Dosimetry on a Child phantom under Therapeutic Proton Irradiation using TL Dosimeters

Strategic Research Agenda of EURADOS, highlighting synergies

Introduction to Ion Beam Cancer Therapy

Dosimetry in digital mammography

Radiologic Units: What You Need to Know

Imaging of Radiation Dose Using Cherenkov Light

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

The title of the presentation is: Neutron production with clinical LINACs for BNCT studies in physical, medical and biological fields.

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

A brief presentation of The TERA Foundation

NEUTRONS. 1. Exposure Data

The Albedo Dosimeter for Personnel Monitoring in Fast-Neutron Radiation Fields

Radiation Monitoring Instruments

Computer modeling of radiation effects

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

A fast Monte Carlo toolkit on GPU for treatment plan dose recalculation in proton therapy

High-Dose Standardization Study For γ-rays radiation processing at NIM

ISO INTERNATIONAL STANDARD

COMPARING THE RESPONSES OF TLD 100, TLD 600, TLD 700 AND TLD 400 IN MIXED NEUTRON-GAMMA FIELDS

ACCELERATORS FOR HADRONTHERAPY

A Monte Carlo Study for Photoneutron Dose Estimations around the High-Energy Linacs

Overview of Clinical and Research Activities at Georgetown University Hospital

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters

Biological Optimization of Hadrontherapy. Uwe Oelfke

The clinical use of OSLD

Reports and Activities of International Commission on Radiation units and Measurements ICRU

IN VIVO IMAGING Proton Beam Range Verification With PET/CT

Evaluation through comet assay of DNA damage induced in human lymphocytes by alpha particles. Comparison with protons and Co-60 gamma rays

Radiation -- A Cosmic Hazard to Human Habitation in Space

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

On the optimal energy of epithermal neutron beams for BNCT

Transcription:

Venue: IEEE NSS/MIC/RTSD Conference, Seoul, South Korea, 27 th October 2013 Workshop: NWK3/RD1 Radiation Protection and Dosimetry M. Caresana a, A. Sashala Naik a,c, S. Rollet b, M. Ferrarini a,d a Polytechnic of Milan, Department of Energy, Milan, Italy b AIT Austrian Institute of Technology, Vienna, Austria c Mi.am srl, Fabiano di Rivergaro, Italy d CNAO National Centre for Oncological Hadrontherapy, Pavia, Italy ARDENT is a Marie Curie Initial Training Network funded by the European Commission 7 th Framework Programme, Grant Agreement 289198.

Outline Neutron dosimetry with CR-39 track detectors Irradiation in 0.5 to 100 MeV monoenergetic (PTB - Germany) and quasi-monoenergetic (Ithemba labs - South Africa) neutron beams Monte Carlo simulations and comparison with Experiments Conclusion & Perspectives 27/10/2013 Alvin Sashala Naik - Seoul, IEEE Conference 2

Neutron Dosimetry with CR-39 detectors Physics of track detectors When an ionizing charged particle passes through a dielectric material the transfer of energy to electrons results in a trail of damaged molecules along the particle s track B. Dorschel et al. / Radiation Measurements 37 (2003) 563 571 The tracks can be made visible by etching in NaOH at 98 C for 90 minutes. The opening of the track is then of about 5-20 µm depending on the type and energy of the hadrons 27/10/2013 Alvin Sashala Naik - Seoul, IEEE Conference 3

Neutron Dosimetry with CR-39 detectors Intercast CR-39 track detector Politrack TM automatic CR-39 reader 27/10/2013 Alvin Sashala Naik - Seoul, IEEE Conference 4

Neutron Dosimetry with CR-39 detectors CR-39 detector analysis with POLITRACK TM Automatic counting and geometrical analysis of the tracks (a) Track filtering (account for dust particles or surface defects) (b) V t and LET nc and impinging angle determination (c) LET nc distribution (d) (a) (c) (b) (d) 27/10/2013 Alvin Sashala Naik - Seoul, IEEE Conference 5

What is LET nc measured in CR-39? Etching time 60 min Alpha energy 6.1 MeV (Cf-252) Etching time 90 min Alpha energy 6.1 MeV (Cf-252) 10.0 µm 15.0 µm Residual energy=3.35mev V Tmean *t = =22.9 µm Residual energy=0 V Tmean *t = =39.5 µm Ei Er 6100 3350 LET kev nc 120 x 22.9 µm Ei Er 6100 0 LET kev nc 154 x 39.5 LET nc is also commonly referred to as the mean LET. µm 27/10/2013 Alvin Sashala Naik Seoul, IEEE Conference 6

Uses of CR-39 track detector Personal dosimetry Routine dosimetry in nuclear facilities Hadrontherapy centers for oncology Ambient dosimetry Stray radiation around particles accelerator CERN, Paul Scherrer Institute (PSI), etc. Complex radiation fields In Space: International Space Spation (ISS) Cosmic rays: aboard commercial aircrafts Advantages: Cheap, easy to use, convenient size to mount as a dosimeter 27/10/2013 Alvin Sashala Naik Seoul, IEEE Conference 7

Irradiation in 0.5 to 100 MeV neutrons In the PMMA radiator, the type of secondary particles produced is strongly dependent on the neutron beam energy (E n ): E n < 10 MeV : (n,p) reactions E n > 10 MeV : (n,p) reactions + (n,α) reactions + (n,d) reactions + (n,t) reactions http://www.oecd-nea.org/janis/ Fragmentation of O and C atoms due to inelastic scattering as the neutron cross section becomes non-negligeable for E n > 10 MeV 14/10/2013 27/10/2013 Alvin Alvin Sashala Naik Naik Seoul, - IEEE October Conference 2013 8

LET nc measured in CR-39 detectors 8 MeV neutron beam 100 MeV neutron beam Protons Background Protons + α + D + T α + D + T Protons delivering the dose for LET < 100 kev/µm and heavier hadrons delivering the dose for LET > 100 kev/µm 27/10/2013 Alvin Sashala Naik Seoul, IEEE Conference 9

Irradiation in 0.5 to 100 MeV neutrons Etching removes the first 15 µm of the surface of the detector. Around 50% of the dose is not measured because: Hadrons impinging at a low angle with respect to the detector surface are not detected due to etching. Removed layer due to etching: 15 µm θ > θ crit θ < θ crit Before etching After etching Hadrons having a low LET, e.g. protons with energy > 10 MeV are not detected due to etching Yet, a stable response of 0.54 ± 0.09 is measured for the whole range of neutron energies Caresana, M., Ferrarini, M., Parravicini, A., Sashala Naik, A. Evaluation of a Personal and Environmental Dosimeter based on CR- 39 Track Detectors in Quasi-Monoenergetic Neutron Fields. Radiat. Prot. Dosim., submitted in the proceeding of Neudos12 conference 14/10/2013 27/10/2013 Alvin Alvin Sashala Naik Naik Seoul, - IEEE October Conference 2013 10

Fluence Simulated LET distribution with FLUKA 1.E+00 PMMA CR-39 1.E-01 1.E-02 1.E-03 All hadrons excluding protons E > 10 MeV Protons only Alpha particles only 1.E-04 1.E-05 1.E-06 1.E-07 1.E-08 1.E-09 1.E-10 1.E-11 1 10 100 1000 LET kev/µm LET distribution obtained using FLUKA for 100 MeV neutrons: the LET plot illustrates the dose contribution due to the different types of secondary particles produced in the PMMA 27/10/2013 Alvin Sashala Naik Seoul, IEEE Conference 11

LET * (dn/dlet) LET * Fluence Comparison using irradiation in 100 MeV neutrons Measured LET nc in CR-39 Simulated LET in CR-39 with FLUKA 6 4.E-06 5 4 4.E-06 3.E-06 3.E-06 3 2.E-06 2 1 2.E-06 1.E-06 5.E-07 0 1 10 100 1000 mean LET (kev/µm) 0.E+00 1 10 100 1000 LET (kev/µm) Measured mean LET spectrum Alpha particles LET spectrum from FLUKA 27/10/2013 Alvin Sashala Naik Seoul, IEEE Conference 12

LET * (dn/dlet) LET*Fluence Comparison using irradiation in 100 MeV neutrons Measured LET nc in CR-39 Simulated LET in CR-39 with FLUKA 6 4.E-04 5 4.E-04 4 3.E-04 3.E-04 3 2.E-04 2 2.E-04 1 1.E-04 5.E-05 0 1 10 100 1000 0.E+00 1 10 100 1000 mean LET (kev/µm) LET kev/µm Measured mean LET spectrum Protons LET spectrum with a cut to protons higher than 10 MeV in a 10 cone normal to the detector 27/10/2013 Alvin Sashala Naik Seoul, IEEE Conference 13

Detector Response Monte Carlo simulations for neutron dosimetry (FLUKA) When looking at the energy deposited at the surface of the detector, where the tracks are produced, a simulated response close to the measured response can be found when removing the dose contribution from the particles that are not detected in CR-39. 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 Measurements FLUKA 0 10 20 30 40 50 60 70 80 90 100 110 Neutron energy (MeV) 27/10/2013 Alvin Sashala Naik - Seoul, IEEE Conference 14

Conclusion & Perspectives More calibration points at IRSN (lower + intermediate energies) and Los Alamos (higher energies) to have more experimental data More issues regarding the detection limit caused by etching have to be taken into account in the simulations in order to improve the LET comparison between experiments and simulations Evaluate the angular dependence of the detection system with a PuBe source at CERN and verify results against Monte Carlo simulations (MCNPX and FLUKA) 27/10/2013 Alvin Sashala Naik - Seoul, IEEE Conference 15

THANK YOU FOR YOUR ATTENTION! This research project has been supported by the Marie Curie Initial Training Network Fellowship of the European Community s Seventh Framework Programme under Grant Agreement PITN-GA-4 2011-289198-ARDENT 27/10/2013 Alvin Sashala Naik Seoul, IEEE Conference 16