PROCEDURE FOR GENERATION AND TESTING OF MAINSTREAM TOBACCO HEATING SYSTEM (THS or IQOS) AEROSOL USING A LINEAR SMOKING MACHINE

Similar documents
The importance of offering adult smokers a portfolio of potentially less harmful products

CORESTA RECOMMENDED METHOD N 22

What is combustion and why is the absence of combustion important for heat not burn products

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Advanced in vitro exposure systems

E L E C T R O N I C VA P O R I Z E R S. User Manual

Heat-not-Burn Products: Scientific Assessment of Risk Reduction

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

MESH NEBULIZER INSTRUCTION MANUAL. Model NE-U22

Modelling the effects of user exposure to harmful emissions across the spectrum of nicotine delivery

Operator s Manual Index NOTE:

THIS PRODUCT DOES NOT CONTAIN TOBACCO OR CONCENTRATE MATERIALS.

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Assessment of the Tobacco Heating System (THS) 2.2, A Candidate Modified Risk Tobacco Product: From Concept to Early Clinical Data

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT

Please read this User s Manual completely before use to ensure full and proper function of your newly purchased SmokeStik. Please keep this manual in

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

cigarettedesigner 4.0

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Blood Glucose Monitoring System. User Guide

Operating Instructions SaHoMa -II mobile ultrasonic nebulizer

Lily 说明书 尺寸 56*118mm 封面 250G白卡白珠光 烫银 内页 128g双铜纸四色印刷 装订方式 胶装 Tas i, L i! Lily 说明书

CORESTA RECOMMENDED METHOD N 25

ProVari Owner s Manual

User Manual RECHARGEABLE KIT. Includes: 1 PLUS+ rechargeable pack 2 PLUS+ batteries 1 wall charger 1 USB cable 3 Classic Tobacco flavor tanks

Tobacco Heating System 2.2, A Candidate Modified Risk Tobacco Product: Cardiovascular Disease Risk Assessment

Cardiovascular effects of nicotine vs. cigarette smoke

Medescan Nebuliser Med - S600A Instructions Manual

V2 NOTEBOOK-CIG AND/OR V2 POWER-CIG

Items in the package:

INTERNATIONAL STANDARD

FEATURES AND PERFORMANCE OF THE HPP SMOKING MACHINE. Dritan Xhillari

JUUL and Other Emerging Tobacco Products. Emily McClelland, M.S. December 6, 2018

FOOD CALORIMETRY OVERVIEW & PURPOSE

Cigarette Smoking Machine CSM-SCSM. User s Manual

check on line for the newest version of this guide. version 1.1

The Omicron vaporizer is the world s first and only non-flame powered

Rhino Clear Sprint Atomizer

Air Quality assessment during indoor use of the Tobacco Heating System 2.2

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

FUSE AIR. Instruction Guide

ELECTRONIC CIGARETTE KIT USER MANUAL

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

Guideline for Measurement Method of Harmful Ingredients in Cigarette-type Smoking Craving Suppressant

Welcome to the world of Cottien electronic cigarettes!

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

The Effect of Puff Profile and Volume on the Yields of E-Cigarettes

Pollen Slide Mounting Protocol

USER MANUAL. Genuine. Satisfaction.

Portable Equine Nebuliser System. User Manual

LIFEBOX TROUBLESHOOTING. Tips and hints

Ketonix Manual 2016 v1.2 EN. Ketonix Manual 2016 v1.2

X [dream] Gebrauchsanweisung User manual

The concept that not all tobacco and nicotine products

Cigarettes cause cancer. Tobacco contains nicotine. Nicotine is an addictive drug.

itaste CLK 1280说明书 尺寸 56*96mm 封面材质 157g 双铜板纸单面过哑胶 内页材质 128g 双铜纸双面印刷 装订方式 胶装 U S E R M A N U A L

CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT.

Blood glucose monitor. MediTouch 2

CORESTA Recommended Method No. 84

Nebu 100s Series. Instruction Manual

Rebuildable atomizer SvoeMesto Kayfun v3.1 ES - User manual

SUPER CPAP POWER PACK

Cigarette Smoke Generator

TNCO Testing procedures

Gentleman s Brand. Ambassador kit USER GUIDE

Fraser Health Authority Accu-chek Inform II: Training Script

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

This document is a preview generated by EVS

Compressor Nebulizer Instruction Manual Part No.: 5055

Lab 7: Heat and Calorimetry

How innovation will deliver a smokefree

User Manual Verizon Wireless. All Rights Reserved. verizonwireless.com OM2260VW

Instruction Manual for minivap Vaporizer. By HERMES Medical Engineering SL.

Manufacturer s information

INSTRUCTION MANUAL. Compressor Nebulizer System NE-C25

E-cigarette consumption and puffing topography data. Dr Sudhanshu Patwardhan FDA CTP Workshop, Hyattsville, Maryland. March 9, 2015.

itaste SVD 2.0 USER MANUAL

INSTALLATION MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

Compressor Nebulizer System

Thank you for purchasing this vaporizer, this is the advanced complete. baking vaporizer making the vaporization process very fast and pure,

Dear HighQ Check System Owner :

Actual Use Study of the Potential Reduced-Risk Product (RRP): Tobacco Heating System (THS)

Development and validation of a device for measuring puffing topography of e-cigarette users

How to Rebuild and Replace the Coils in a Mutation X V4 Atomizer

SPORTSART C521M BI-DIRECTIONAL BIKE

Mini-Mist. Owner s Manual. portable nebulizer. PMM241 Rev.3 12/10

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

VP2 electronic cigarette By VaprLife

Contents.

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

Education for self administration of intravenous therapy HOME IV THERAPY. 30 minute - Baxter Pump Tobramycin

Lung Cancer Epidemiology & Prevention. A/Prof Fraser Brims

Owners manual. HTR 1.0 Exercise Bike. T +31 (0) E W ENG. Fitness Benelux

CORESTA Guide N o 18

NovoPen Echo User guide

COLOURS ON CERAMIC PRODUCTS FOR DENTAL USE

Motorised Treadmill Model No: JI1625

TH Premium RIC LI 19. Guide for Hearing Care Professionals

For use only with INSTRUCTIONS FOR USE

Transcription:

PROCEDURE FOR GENERATION AND TESTING OF MAINSTREAM TOBACCO HEATING SYSTEM (THS or IQOS) AEROSOL USING A LINEAR SMOKING MACHINE 1 P age

Table of contents / Table des matières 1 Introduction...3 1 Scope...3 2 Description of the Method...4 2.1 Principle...4 2.2 IQOS components...4 2.3 Accessories for mechanical aerosol generation...5 2.4 Aerosol generation procedure...6 2.4.1 Preparation of IQOS before use...6 2.4.2 Testing Procedure on the linear smoking machine...6 2.4.3 End of the aerosol collection...9 2.5 Cleaning the THD... 10 2.5.1 THD Cap cleaning... 10 2.5.2 THD cleaning... 11 2 P age

1 Introduction Cigarette smoke is produced when the tobacco in a cigarette burns at temperatures in excess of 600 C. At such high temperatures, the tobacco is burned to ash and generates smoke that contains thousands of chemicals, 1 including high levels of harmful and potentially harmful constituents (HPHCs) which are widely recognized to be the most likely causes of smoking-related diseases. 2 The Tobacco Heating System (THS or IQOS, its commercial name), on the other hand, heats tobacco without burning it (combusting) to generate a nicotine-containing aerosol with significantly lower levels of HPHCs. 3 HPCHs levels can be measured by collecting the aerosol from IQOS, using a commercial linear smoking machine. This document provides a detailed description of how the device should be used in this context and step by step instructions for collecting the aerosol of IQOS using a commercial linear smoking machine. 1 Scope This document describes the accessories and the procedures for generating and collecting the IQOS aerosol for the purposes of testing. Mechanical aerosol generation can be performed according to ISO 4 or other smoking regimes (e.g. Health Canada Intense) with the exception of the following requirements which cannot be fulfilled for technical reasons: Air velocity control (air flow) is essentially irrelevant as the there is no tobacco combustion involved. The butt length requirement is not applicable, as the stick is not consumed, and its length remains unchanged after usage. There is no ignition of the HeatStick by an external lighter. The puff count will depend on the puffing frequency, driven by the total heating time of the system which is fixed at 6 minutes. According to this, 12 puffs can be reached when the THS operates under intense puffing regime (55/2/30) but it is limited to 6 puffs when the aerosol 1 Rodgman, A., Perfetti, T.A., The Chemical Components of Tobacco and Tobacco Smoke, CRC Press, Boca Raton (2013). 2 See, e.g., U.S. Department of Health and Human Services, How Tobacco Smoke Causes Disease The Biology and Behavioral Basis for Smoking-Attributable Disease: A Report of the Surgeon General, Atlanta (GA): U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Center for Chronic Disease Prevention and Health Promotion, Office on Smoking and Health (2010). 3 For further information regarding the absence of combustion involved in the IQOS system, see https://www.pmiscience.com/news/absence-combustion-pmi%e2%80%99s-heated-tobacco-productplatform-1. 4 ISO 3308:2012 Routine analytical cigarette-smoking machine Definitions and standards conditions 3 Page

generation is performed under ISO puffing regimen (35/2/60). However, the total number of puffs will depend on the timing of the first puff; for example, a delay in the activation of the puffing regime could result in the device producing only five puffs under ISO. 2 Description of the Method 2.1 Principle Each IQOS device is an autonomous instrument that can be used independently. An activation bar may be used to activate more than one IQOS device simultaneously when using a linear smoking machine. In the absence of an activation bar, each IQOS can be activated manually, but in this situation, we strongly recommend that testers limit the number of devices to ensure simultaneous activation. In both cases, a consumable Heat Stick is inserted into the tobacco heating device, and throughout the aerosol generation process, the Heat Stick remains in contact with a heating blade located inside the THD. 2.2 IQOS components Tobacco Heating Device (THD) The THD and consumable HeatSticks (THS) Holder Cap Charger 4 P age

2.3 Accessories for mechanical aerosol generation Most of the accessories indicated below have been designed and developed by Philip Morris International for use with a linear smoking machine. These accessories are not commercially available for the time being but technical information, engineering drawings, and accessories themselves can be provided upon request. Adaptor plate (aluminium) Adaptor bracket (plexi-glass) THS bracket Alignment tool Activation bar 5 : 5 The activation bar allows the simultaneous activation of the THS on a linear smoking machine when a maximal capacity of the smoking machine is used (up to 20 smoking ports). However, activation can also be done manually by operators but, in this case, we strongly recommend that testers limit the number of devices to ensure simultaneous activation. 5 P age

2.4 Aerosol generation procedure Linear smoking machines should be operated following recommendations from suppliers and/or local procedures. The recommended number of HeatSticks per port varies Depending on the puffing regimen selected: - ISO puffing regimen (35/2/60) : Five HeatSticks per port - Intense puffing regimen (55/2/30): Three HeatSticksper port The aerosol collection must start after the end of the pre-heating phase (20 seconds). 2.4.1 Preparation of IQOS before use Ensure that THD is correctly cleaned before use (refer to chapter 2.5) Ensure the THD is fully charged by placing it in the Main Unit. When the THD has been inserted, close the lid. The LEDs on the Main Unit will flash for approximately 5 minutes. Once the LED signals have gone out, the THD is ready for use. 2 1 1. ON/OFF Switch 2. Charging indicator 2.4.2 Testing Procedure on the linear smoking machine 1. Fit the adaptor plate and the bracket together so that the red stopper of the adaptor plate faces the smoking port 6 P age

2. Install the adaptor bracket with its plate in front of the smoking port by fitting together the bracket and the horizontal metallic rods located on both sides of the smoking port. 3. Several brackets can be installed side by side from left to right. 4. Install the adaptor bracket of the activation bar with its plate from the position 1 to 20. Except at position 5-7 and 14-16 to allow the activation of the bar by the operator (refer to picture in step 11) 5. Check, and if necessary, adjust the alignment of the smoking port by fitting the alignment tool on the adaptor plate with the red screw on the machine side. Rotate the mobile eccentric part of the smoking machine so that the tool fits exactly into the channel 6. When the alignment is adjusted, withdraw the tool and install the THS 7. Install the activation bar on the brackets without the top of the bar. Ensure that the extremities of the bar fit with the extremities of the smoking machine. 7 P age

8. Insert the HeatStick in the THD until it touches the bottom of the THD and the filter is at the edge of the extractor. Install the THS on the bracket then place the filter inside the smoking port. 9. Repeat the operations for each smoking port to be used. 10. Install the activation bar and place the top of the bar on the THD activation switches. 11. Activate the THDs by pressing gently the top of the activation bar for 4 seconds. The LEDs on the THDs will flash for 20 seconds indicating that the pre-heating phase has started. Once the pre-heating is completed, the LEDs will stop flashing. Wait the end of the pre-heating phase before starting the aerosol generation cycle. 8 P age

If the activation bar is not used, devices can be activated manually. Activate the THD by pressing the central start switch gently for 4 seconds. The LED will flash for 20 seconds indicating that the pre-heating phase has started. Once the pre-heating is complete, the LED will stop flashing. Wait the end of the pre-heating phase before starting the aerosol generation cycle. Start Button 12. Activate the aerosol generation cycle. 13. Repeat the process until the appropriate number of HeatSticks (based on the selected puffing regimen) are consumed. Ensure that THDs used for each new aerosol generation cycle are charged (refer to 2.4.1). 2.4.3 End of the aerosol collection Clearing puffs can be drawn after removing the THD. After each aerosol collection run, remove the HeatStick from the cigarette holder using tweezers. Open the extractor and remove the HeatStick. 9 P age

2.5 Cleaning the THD Follow the procedure described bellow at the end of each day or after a maximum of 30 aerosol generation cycles. 1. Charge the THD battery. 2. Remove the THD Cap. Caution: When replacing the THD Cap, be careful to avoid touching the heating blade, which is ceramic and could break. Avoid shock and the mechanical stress. 2.5.1 THD Cap cleaning 1. Blow any dust and residual tobacco bits using industrial compressed air (if available). If necessary, use tweezers to remove remaining tobacco bits. 2. Rinse the THD Cap with running warm water (if an ultrasonic bath is available, perform steps 2.1 to 2.6 only) 2.1 Place the THD Cap in an ultrasonic bath filled with a mix of warm water and Absolute Ethanol (EtOH) (20/80 v/v; preferred temperature = 40 C or higher) for at least 5 minutes. 2.2 Remove the THD Cap from the ultrasonic bath. 2.3 Wash the dirty surfaces of the THD Cap with a cotton swab. 2.4 Rinse the THD Cap with water and then secondly with a mix of Absolute Ethanol (EtOH) and water (80/20 v/v). 10 P age

2.5 Dry it (preferably in an oven for at least 4 hours at approximately 50 C). 2.6 Once completely dried, remove the THD Cap from the oven. 3. Wash the dirty surfaces of the THD Cap with a mix of Absolute Ethanol (EtOH) and water (80/20 v/v) impregnated cotton swab. 4. Rinse the THD Cap with clean water and again with a mix of Absolute Ethanol (EtOH) and water (80/20 v/v). 5. Dry it (preferably with industrial compressed air or in an oven for at least 4 hours at approximately 50 C). If none of these drying methods are available, place the THD Cap on an absorbing tissue for at least 12 hours at room temperature. 2.5.2 THD cleaning 1. Blow off the dust and residual tobacco using industrial compressed air (if available). 2. Perform a self-cleaning as described below : 2.1 Place the THD Cap on the THD and Insert the THD in the Charger and close the Lid. Then press and hold the self-clean button for at least 4 seconds until the cleaning light starts blinking green. This means that the self-cleaning cycle has begun and will continue for a duration of 30 seconds. B A 3. Use a small wooden stick to remove the biggest residual pieces remaining in the THD. 4. Wash the dirty surfaces of the Holder with a cotton swab previously moistened with one or two drops of a mix of Absolute Ethanol (EtOH) and water (80/20 v/v) 11 P age

5. Blow off the residual dust and tobacco bits using industrial compressed air (if available). 6. Once both parts are cleaned and dried (THD Cap & THD) remount the device by putting back the Holder Cap back in place. 7. If you observe some residual dust or tobacco bits in the Charger Lid due to the accumulation of vapours generated during the self-cleaning process, clean it with a cotton swab impregnated with a mixture of Absolute Ethanol (EtOH) and water (80/20 v/v). 12 P age