Product Catalog. EXCOR Pediatric The Ventricular Assist Device for Children

Similar documents
EXCOR VAD. with Stationary Driving Unit Ikus. Instructions for use: version Berlin Heart GmbH Wiesenweg Berlin Germany

Why Children Are Not Small Adults? Treatment of Pediatric Patients Needing Mechanical Circulatory Support

Pediatric Mechanical Circulatory Support (MCS)

Understanding the Pediatric Ventricular Assist Device

EHY-2000 Plus. Loco-Regional Hyperthermia Device. ffor complementary cancer treatment

EHY-3000 series. Oncothermia systems for multi-local. cancer treatment

Technical Data Sheet SONOFLOW CO.55 V1.0

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

With extended functionality the sensors are also applicable for the detection of air bubbles.

Extracorporeal Circuit Cannulae { VENOUS}

VENTRICULAR ASSIST DEVICE - BERLIN HEART NURSING CARE

Implantable Ventricular Assist Devices and Total Artificial Hearts. Policy Specific Section: June 13, 1997 March 29, 2013

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

The Gold Standard in Pediatric VAD Therapy A Compilation of Publications Demonstrating the Clinical Excellence of EXCOR Pediatric

Cardioplegia Circuit Products { CARDIOPLEGIA ADAPTERS}

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip.

Oral surgery and implantology. Easy and flexible. NEW. Respects your needs. Today and tomorrow.

Quality Management System Certification. Understanding Quality Management System (QMS) certification

Quality assurance in medical device industry

SENSATION and CS300 Smaller meets faster. IABP System

Mechanics of Cath Lab Support Devices

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

MEDICAL POLICY Ventricular Assist Devices

NEGATIVE PRESURE WOUND THERAPY PROGRAM

Solutions at GE Inspection Technologies

Kit Assembly. Enhanced Simplicity OPERATIONAL BENEFITS. Automatic venous chamber adjustment. User friendly interface

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

Dräger Alcotest 5510 Alcohol Screening Device

thoracic stent graft system Smallest delivery profile as from 20 F

NEUROSURGERY LiquoGuard

Golden standard for non-invasive body shaping Focused

aks bed concepts for the day-to-day nursing routine for homecare and in-patient applications

Mechanical Support in the Failing Fontan-Kreutzer

Ventricular Assisting Devices in the Cathlab. Unrestricted

UNIVERSITY OF UTAH HEALTH CARE HOSPITALS AND CLINICS

Flexi-Needles. BMI_FLEXINEEDLES_v2 web

Modern Left Ventricular Assist Devices (LVAD) : An Intro, Complications, and Emergencies

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM

EHY-3000 series. Oncothermia systems for multi-local. cancer treatment

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

MultiStim SWITCH and MultiStim SENSOR Setting the trend in nerve stimulation

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

Blood Flow Measurement Devices Market - Global Industry Analysis, Size, Share, Growth, Trends and Forecast, Single User License: US $ 4595

Mechanics of Cath Lab Support Devices

EMS and Nursing Considerations in VAD Patient Care

MagPro by MagVenture. Versatility in Magnetic Stimulation

Acute Mechanical Circulatory Support Right Ventricular Support Devices

HLS CANNULAE SOLUTIONS FROM TIP TO TIP

Automated Blood Pressure Monitor

CyBio Felix Your Automated Application Starts Here

CHANGING THE WAY HEART FAILURE IS TREATED. VAD Therapy

ER75 Electro-Acoustic Ear Simulator. Operating Manual

EMS: Care of the VAD Patient. Brittany Butzler BSN RN VAD Coordinator Froedtert and the Medical College of WI

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

RECOMMENDED INSTRUCTIONS FOR USE

New ventricular assist devices. FW Mohr Clinical seminar: Devices for severe heart failure ESC congress Stockholm 2010

Negative Pressure Wound Therapy

Dräger Alcotest Handheld Product Suite

THE USE of VENTRICULAR ASSIST DEVICES in CHILDREN: CURRENT OPTIONS & FUTURE TRENDS

MagPro by MagVenture. Versatility in Magnetic Stimulation

Dräger Alcotest 3820 Alcohol Screening Device

accurate perception. Stethoscopes

Advancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis

Sensitivity. is the basis of accurate perception. Stethoscopes

Device Preparation (all steps to be performed per standard interventional technique)

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Dental Line. 3D digital panoramic system. radiology ahead

Pulsation Systems. Setting the standard for durable and consistent pulsation. Detacher controlled. Master controlled. Individual. Vacuum operated.

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Introducing the COAPT Trial

Exceptional versatility without compromise

Veterinary Infusion Solutions

Arterial Puncture Wrist

1/21/2016. HeartMate II Indications for Use. Ventricular Assist Device Overview. Jon G. Echterling MSN, CCRN, FNP-BC. Learning Objectives

ECMO as a bridge to durable LVAD therapy. Jonathan Haft, MD Department of Cardiac Surgery University of Michigan

experiences that matter

Sleep diagnostics systems

VAD come Destination therapy nell adulto con Scompenso Cardiaco

Achieving Physiologic Perfusion with Ventricular Assist Devices: Comparison of Control Strategies

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

the truly automated all-in-one hearing screener

MICS & FEMORAL CANNULAE

OPENING UP A NEW WORLD

Evaluation of Native Left Ventricular Function During Mechanical Circulatory Support.: Theoretical Basis and Clinical Limitations

Case - Advanced HF and Shock (INTERMACS 1)

:- HEINE GAMMA G -Series Shockproof and Latex-free Sphygmomanometers

Destination Therapy SO MUCH DATA IN SUCH A SMALL DEVICE. HeartWare HVAD System The ONLY intrapericardial VAD approved for DT.

New Core Alignment Fusion Splicer FSM-50S

A GUIDE TO OUR NIBP TECHNOLOGY

Dräger Alcotest 3820 Alcohol Screening Device

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

SiOCX TF prosthetic sockets

Our Leading Range of Products. Pipettes designed for micromanipulation, denuding and handling

RLS /M MX SERIES

HEINE Dermatoscopes. Magnification Magnification x 40x* (digital)

Fear turns into satisfaction. PerioScan the gentle prophylaxis competence

Setting big things into motion.

Transcription:

Product Catalog EXCOR Pediatric The Ventricular Assist Device for Children

About Berlin Heart Berlin Heart Develops, Produces and Provides Innovative Devices for Mechanical Supporting of the Heart. While only the EXCOR Pediatric is approved for use in the US, our products INCOR, EXCOR Adult and EXCOR Pediatric span the entire range of medical indications for patients of all ages from newborn babies to adults. With reiable and globally successful products, Berlin Heart is one of the industry s market leaders. Our claim is to develop innovative solutions with utmost precision and reliability. The short time to market and technological features of our products are unique and exemplary. Our future developments shall continue to meet the demands of our customers and the market. With our solid position we will continue our course of worldwide expansion based on innovative products, while relying on strategic international partnerships.

EXCOR Pediatric The Ventricular Assist Device for Children LVAD / BVAD EXCOR Pediatric is a mechanical circulatory support system that provides short- to medium-term assistance to the failing left and right ventricle. EXCOR has performed well in several thousand cases with proven benefits and safety. The system is specifically designed for infants and children with life-threatening heart failure refractory to optimal medical therapy. Your young patients benefit directly from restored hemodynamics, a result of the improved circulation provided by the device. Treatment with the EXCOR Pediatric may also improve the quality of life for patients with severe heart failure. Patients of every age accept the system and gain valuable time while waiting for an organ transplant or in some patients recovery of their own heart. When using this system, many patients are able to participate in everyday activities, pursue their hobbies. move freely around the hospital. EXCOR Pediatric Proven Quality for Optimal Therapeutic Success in the Youngest Patients EXCOR Pediatric is designed for reliable use over a period ranging from days to several months and even years. The selected materials, surfaces and geometries are optimized so that complications are avoided even with long-term treatment. As a manufacturer specializing in mechanical circulatory support systems, we have incorporated unequalled clinical experience and scientific competence into our products, so that today a fully developed system with proven therapeutic success and minimized complications is available for clinical use. EXCOR VAD systems are currently used in more than 150 specialized centers worldwide, with new centers requesting the device on a regular basis. Extensive Product Range for Individualized VAD Therapy The EXCOR system incorporates paracorporeal, pulsatile membrane pumps and implantable silicone cannulae. The Berlin Heart EXCOR satisfies all anatomical, clinical and practical requirements of VAD therapy with an extensive portfolio of differently sized blood pumps with different valve configurations, a wide selection of atrial, apex and arterial cannulae, as well as stationary and mobile driving units. EXCOR Pediatric EXCOR Drivers Berlin Heart Services

The Paracorporeal VAD System for your Youngest Patients 10 ml blood pump 15 ml blood pump 25 ml blood pump 30 ml blood pump Blood Pumps with PU Valves Article no. Pump volume [ml] Connector diameter [Ø mm] P10P-001 10 6 P15P-001 15 9 P25P-001x01 25 9 P30P-001x01 30 9 P50P-001 50 12 P60P-001 60 12 P80P-001* 80 12 Blood Pump Characteristics Features Description Housing material Polyurethane, transparent for permanent visual inspection Coating Carmeda BioActive heparin coating Pump membrane Three-layer redundant membrane De-airing port For air removal after pump connection Pump valves Tri-leaflet polyurethane (PU) valves Weight 45 g to 140 g (10 ml / 80 ml pump) Blood Pumps with Tilting Disk Valves Article no. Pump volume [ml] Connector diameter [Ø mm] P50M-001* 50 12 P60M-001* 60 12 P80M-001* 80 12 EXCOR Pediatric 9 50 ml blood pump 8 7 6 5 4 3 50 ml 60 ml EXCOR Drivers 60 ml blood pump 2 30 ml 25 ml 1 15 ml 10 ml 10 20 30 40 50 60 Pump Size Selection for Young Patients *For Use in Canada under Special Access Currently not approved in the US. Berlin Heart Services

Driver rental Accessories Article no. T00L-002 T00L-001* L20H-002x01 L20H-003x01 Description Accessory set PU valves Accessory set tilting disk valves Driving tube, red Driving tube, blue Connector Sets Article no. Description A06-009 Connecting set, Ø 6 to Ø 9 mm A09-012 Connecting set, Ø 9 to Ø 12 mm Cannula extension Sets Article no. Description A06-006 Cannula extension set, Ø 6/6 mm A09-009 Cannula extension set, Ø 9/9 mm A12-012 Cannula extension set, Ø 12/12 mm Connecting set for cannulae *For Use in Canada under Special Access Currently not approved in the US.

EXCOR Pediatric System Overview Apex Cannulae Atrial Cannulae Arterial Cannulae Adapter Blood Pumps Ø 5 mm C14A-040 C15V-040 C80G-040 22 cm 20 cm 20 cm Ø 6 mm C18A-020 25 cm C19V-020 25 cm C80G-021 25 cm A06-006 A06-009 P10P-001 Apex cannula Ø 9 mm C22A-004 C22V-004 C60G-004 27 cm, 22 cm cut off* 28 cm, 23 cm cut off* C25V-004 28 cm, 23 cm cut off* C85G-004 A09-009 28 cm, 23 cm cut off* 28 cm, 23 cm cut off* C00P-004 A09-012 P15P-001 P25P-001x01 P30P-001x01 27 cm, 21 cm cut off** Atrial cannula Ø 12/9 mm C22A-004 C22V-004 C60G-004 27 cm 28 cm 28 cm C25V-004 C85G-004 28 cm 28 cm C00P-004 27 cm** Arterial cannulae * With/without stage All indications are nominal values, individual products may vary. ** For Use in Canada - Currently not approved in the US. Ø 12 mm C27A-001 C22V-002 C60G-002 26,5 cm 33 cm 33 cm C26V-002 C85G-002 33 cm 33 cm C00P-001 26 cm** 35 30 25 20 15 10 cm 35 30 25 20 15 10 cm 35 30 25 20 15 10 cm A012-012 P50P-001 P60P-001 P80P-001**

EXCOR Pediatric Cannulation Options Cannulae Article no. Inner diameter [mm] Cannula length [mm] Head length [mm] Head angle [ ] Remark Apex cannulae C14A-040 5 220 14 0 C18A-020 6 250 18 0 C22A-004 12/9 270/220* 22 0 C27A-001 12 265 38 0 Atrial cannulae C15V-040 5 200 15 80 C19V-020 6 250 19 85 C22V-004 12/9 280/230* 22 45 C25V-004 12/9 280/230* 25 45 C22V-002 12 330 22 45 C26V-002 12 330 26 45 Arterial cannulae C80G-040 5 200 4,5 80 C80G-021 6 250 5 80 C60G-004 12/9 280/230* 0 60 with flexible metal reinforcement C85G-004 12/9 280/230* 0 85 with flexible metal reinforcement C60G-002 12 330 0 60 with flexible metal reinforcement C85G-002 12 330 0 85 with flexible metal reinforcement COOP-001** 12 260 0 - graft adapter COOP-004** 12/9 270/210* 0 - graft adapter EXCOR Pediatric EXCOR Pediatric LVAD apical EXCOR Pediatric LVAD atrial Cannulae Characteristics Features Shaft material Velour Geometry Tunneling * With/without stage All indications are nominal values, individual products may vary. Description Flexible, long-term implantable, medical grade silicone Polyester velour sheathing for tissue ingrowth Variety of diameters, lengths, angles and shapes Cannula tunneling tip, included in delivery ** For Use in Canada - Currently not approved in the US. EXCOR Drivers Berlin Heart Services EXCOR Pediatric BVAD left apical EXCOR Pediatric BVAD left atrial

EXCOR Driving Systems Ikus Stationary Driving Unit for EXCOR Paracorporeal VAD System The Ikus driving unit is designed for stationary use with the EXCOR Adult and EXCOR Pediatric blood pumps. Pneumatic pump supply system for pulsatile blood flow Flexible: for all pump sizes, driving pressures at rates from 30 to 150 bpm Triple redundancy of core components for maximum safety Up to 30 minutes battery operation for patient mobility within the hospital Drives Article no. D03I-111 EXCOR Stationary Driving Unit Ikus (115V/60Hz) Features Description For use with pump sizes 10, 25, 30, (univentricular/ 50, 60, 80* ml biventricular) Systolic pressure 60 to 350 mmhg Diastolic pressure -100 to 0 mmhg Pump frequency 30 to 150 bpm Relative systolic duration 20 to 70% Input voltage AC 115 V Front panel Ikus stationary driving unit Power input 575 VA Mains power fuse 5 A (115 V) Protection class IPX1 min. 30 minutes. Alarm after 30 minutes Battery operation (at max. 30 C ambient temperature, otherwise less) Battery charge duration 6 h 2000 operating hours or 6 months (at max. 30 C ambient Maintenance interval temperature, otherwise 1000 operating hours or 3 months) Ambient temperature, operation Ambient temperature, transportation and storage Relative ambient air humidity +10 to +30 C with restrictions up to +35 C -10 to +50 C 6 h rest phase after transport before commissioning 45 to 75 % *For Use in Canada under Special Access Currently not approved in the US. Please read the instructions for use carefully for detailed information prior to use of the Berlin Heart products. EXCOR Pediatric EXCOR Drivers Berlin Heart Services

Ikus Safety and Flexibility for all patients Triple drive pneumatic redundancy safeguards against failure Flexible driving unit on castors, for the full pump range from 10 ml to 80 ml stroke volume For univentricular and biventricular support Synchronous, asynchronous or separate pulse operation mode for both ventricles Display allows perfect monitoring of actual drive parameters Acoustic and visual warning system Battery operation time of at least 30 minutes Screenshot User interface for pump adjustment

EXCOR Driving Systems Excor mobile Quality of Life Through Mobility Minimum weight for maximum flexibility and patient comfort High reliability by redundancy of the pneumatic components Easy battery changing with continuous operation 10 hours univentricular battery operation Excor mobile driving system caddy Excor mobile driving system Article no. D01E-001* Features Description For use with pump sizes (univentricular/biventricular) 60 and 80 ml Systolic pressure (limit) 250 mmhg Diastolic pressure (limit) -100 mmhg Pump frequency 60 to 90 bpm Relative systolic duration 40 to 60 % Power consumption (at 80 bpm) Battery operation left approx. 12 W; right approx. 8 W univentricular: approx. 10 h biventricular: approx. 5 h Emergency battery operating time max. 15 min Recharge time approx. 3 h Weight of accumulator battery 1.1 kg Weight (carrying unit, driving units and batteries) 9 kg Operating temperature + 10 C to + 40 C Ambient atmospheric pressure Relative humidity < 95 % Protection class IPX1 Maintenance interval (driving unit) > 900 hpa, approx. 1000 m above mean sea level 10 million pump cycles or 6 months EXCOR Pediatric Excor mobile battery Excor mobile battery Article no. Features Dimensions Weight Output voltage Capacity under load Charging time Protection class 1400165x00 Description 88 x 245 x 50 mm 1.12 kg 21.6 VDC nominal 24.6 VDC no load 5 h approx. 3 h approx. IPX1 *For Use in Canada under Special Access Currently not approved in the US. EXCOR Drivers Berlin Heart Services

Berlin Heart Services Our Services for your Benefit The Scientific Method Our Clinical Science The Berlin Heart Clinical Science team will support you in your efforts to publish scientific results related to your experience with Berlin Heart products: Design of clinical trials or post-market follow-up evaluations Statistical analysis Scientific assessments of our continuous product development Customized Service around the World Customer Service any Day and any Time Our customer service and logistics team has specialized experience with worldwide shipping and customs matters to ensure the best shipping methods and the quickest possible delivery times in order to meet your most urgent needs. This team is able to organize shipments in any part of the world, always in accordance with the local regulatory requirements, and provide you with the products and equipment you need at any time, any day of the year. Inside North America: Emergency Hotline: 866 249 0128 You Need Support? Call us 24 Hours, 365 Days a Year for Clinical Assistance Our clinical affairs team with a long standing experience in the field of mechanical circulatory support provides excellent support for all clinical and technical matters (patient selection, timing, implantation, follow up, data analysis and subsequent recommendations). In person, on site or advising by phone they are available throughout the year, 24 hrs a day. Inside North America: Emergency Hotline: 866 249 0128 EXCOR Pediatric EXCOR Drivers Successful VAD Treatment Interdisciplinary collaboration is necessary for optimum clinical success: not only is patient selection and VAD implantation crucial, but integration across all functional patient care disciplines including social care should be achieved. Berlin Heart Services

Please read the instructions for use carefully for detailed information prior to use of the Berlin Heart products. If you have any additional questions, please don t hesitate to contact us. Berlin Heart Inc. 200 Valleywood Suite B-100 The Woodlands Texas 77380 Phone (281) 863-9700 Fax (281) 863-9701 info@berlinheart.com www.berlinheart.com Berlin Heart GmbH Wiesenweg 10 12247 Berlin Germany Phone +49 30 81 87-26 00 Fax +49 30 81 87-26 01 info@berlinheart.de www.berlinheart.de Humanitarian Device. Authorized by Federal law for use in the treatment of pediatric patients with severe isolated left ventricular or biventricular dysfunction who are candidates for cardiac transplant and require circulatory support. The effectiveness of this device for this use has not been demonstrated. MPC21.3 May 2014 Berlin Heart GmbH