Potential and Limitations for Determining Lycopene in Tomatoes by Optical Methods

Similar documents
Handling & Processing Section. Color and Pigment Development of Mature-green Tomatoes Treated with Hot Water

Nippon Shokuhin Kagaku Kogaku Kaishi Vol. /., No.1, -/+ -// (,**1) 351. a, b,

Carotenoid Extraction and Quantification from Capsicum annuum Richard D. Richins, James Kilcrease, Laura Rodgriguez-Uribe and Mary A.

LYCOPENE FROM BLAKESLEA TRISPORA CHEMICAL AND TECHNICAL ASSESSMENT (CTA)

Isolation of five carotenoid compounds from tangerine tomatoes

Effect of Pulsed Electric Field on Lycopene Extraction

UV Spectrophotometric Estimation of Alprazolam by Area Under Curve And First Order Derivative Methods in Bulk and Pharmaceutical Dosage Form

Relative Measurement of Zeaxanthin Stereoisomers by Chiral HPLC

RECOVERY AND ISOMERIZATION OF CAROTENOIDS FROM TOMATO PROCESSING BY PRODUCTS

Asian Journal of Food and Agro-Industry ISSN Available online at

THE EFFECT OF FRYING AND STEAMING ON β-carotene CONTENT IN ORANGE AND YELLOW SWEET POTATO (Ipomoea batatas (L) Lam.)

Vitamin C Assay Kit. ( DNPH method )

Introduction. Cell Biology OLM

MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON

Comparative study of analytical method development of fluconazole in tablets and capsule by ultraviolet spectrophotometric method

What Is the Relationship Between the Amount of Transmitted Light Through a Solution and Its Concentration?

Validated UV Spectrophotometric Method Development And Stability Studies Of Acamprosate Calcium In Bulk And Tablet Dosage Form

Pelagia Research Library

HarvestLab John Deere Constituent Sensing

Available online Research Article

Bioactive Compounds In Watermelon Flesh And Rind

Biology 2180 Laboratory #3. Enzyme Kinetics and Quantitative Analysis

Independent Research Investigation

Development and validation of UV spectrophotometric estimation of lisinopril dihydrate in bulk and tablet dosage form using area under curve method

0 9 : >?! 0 (.56± E

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

For more information, please contact: or +1 (302)

Determination of Copper in Green Olives using ICP-OES

Ascorbic Acid Assay Kit Manual Catalog #

Trans Fat Determination in the Industrially Processed Edible Oils By Transmission FT-IR Spectroscopy By

IJRPC 2011, 1(4) Rohan et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (3): (

Lycopene and Total Carotenoid Content as Descriptors for Citrullus lanatus: Limitations and Preliminary Trials

Research Article Derivative Spectrophotometric Method for Estimation of Metformin Hydrochloride in Bulk Drug and Dosage Form

Work-flow: protein sample preparation Precipitation methods Removal of interfering substances Specific examples:

Enzyme Analysis using Tyrosinase. Evaluation copy

Available Online through Research Article

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

Assay Kit for Measurement of Proteoglycan. (Sulfated Glycosaminoglycan Quantification Kit)

Development and validation of spectrophotometric method for simultaneous estimation of Sumatriptan and Naproxen sodium in tablet dosage form

International Journal of Advances in Pharmacy and Biotechnology Vol.3, Issue-1, 2017, 1-7 Research Article Open Access.

BIOL 305L Laboratory Four

LIFESTYLE MANAGEMENT

Student Manual. Background STUDENT MANUAL BACKGROUND. Enzymes

ENZYME ACTIVITY. Readings: Review pp , and in your text (POHS, 5 th ed.).

5. BIOCHEMICAL COMPOSITION AND FOOD VALUE OF RIBBON FISH L. SAVALA

STANDARD OPERATING PROTOCOL (SOP)

Thermal Degradation Kinetics of Pigments and Visual Color in Watermelon Juice

Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC

What Is the Relationship Between the Amount of Transmitted Light Through a Solution and Its Concentration?

Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000

Development and Validation of UV- Spectrophotometric Method for Estimation of Simvastatin in Bulk and Solid Dosage Form.

Procine sphingomyelin ELISA Kit

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Spectrophotometric Method for Estimation of Sitagliptin Phosphate in Bulk...

Lutein Content Analysis in Green and Red Spinach (Amaranthus tricolor L.) by Visible Spectrophotometry. Abstract

Journal of Chemical and Pharmaceutical Research, 2018, 10(2): Research Article

PHARMA SCIENCE MONITOR AN INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES

Irena Vovk 1, Breda Simonovska 1, Danica Agbaba 2 and Gordana Popović 2

Analysis of Polyphenoloxidase Enzyme Activity from Potato Extract Biochemistry Lab I (CHEM 4401)

Method Development and Validation of Emtricitabine in Bulk by UV Spectroscopy

ab Oxalate Assay Kit (Colorimetric)

Biodiversity Study & Biomass Analysis

THE ULTRAVIOLET ABSORPTION SPECTRUM OF PEPSIN. (From the Laboratory of General Physiology, Harvard University, Cambridge)

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

CHAPTER 4 EFFECT OF OXALIC ACID ON THE OPTICAL, THERMAL, DIELECTRIC AND MECHANICAL BEHAVIOUR OF ADP CRYSTALS

Using the ISO characterized reference print conditions to test an hypothesis about common color appearance

Reagent Set DAS ELISA, Alkaline phosphatase label SRA 22001, SRA 23203, SRA 27703, SRA & SRA ToRSV, ArMV, GFLV, AnFBV and PDV

Dopa oxidase. Reaction: The reaction is the conversion of L-dopa (L-3,4- dihydroxyphenylalanine) to dopachrome (red). dopa oxidase

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

DEVELOPMENT OF UV SPECTROPHOTOMETRIC METHOD FOR THE ESTIMATION OF EZETIMIBE FROM TABLET FORMULATION

Evolutions of β-carotene and Lycopene in a Natural Food Colorant from Gac (Momordica cochinchinensis Spreng) Arils during Drying

Annealing Influence on the Optical Properties of Nano ZnO

Enzymatic Assay of PROTEASE (EC )

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Mobile FTIR Analyzers from Agilent. Expedite Food QA/QC Improve Food Production, Safety and Quality

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

RayBio DPP4 Inhibitor Screening Kit

Journal of Chemical and Pharmaceutical Research

THE CREATININE LEVEL OF BLOOD SERUM AS AN INDICATOR OF CARCASS COMPOSITION 1 PAUL R. WUTHIER AND P. O. STRATTON

Thermal inactivation of lipoxygenase and hydroperoxytrienoic acid lyase in tomatoes

Jagua (Genipin-Glycine) Blue (Tentative)

Cuvette Assay for GSH/GSSG (Reduced/Oxidized Glutathione) For Research Use Only INTRODUCTION

Observed amount of compound in sample % recovery = 100 Amount of all compound present in sample. The recovery values are summarized in Table 4.

For the rapid, sensitive and accurate measurement of Triglyceride in various samples.

Enhancement of lycopene extraction from tomato peels by enzymatic treatment

Determination of Cannabis Extract Potency Degradation Mechanism and Rate by Infrared Spectroscopy

Human Creatinine Urinary Detection Kit

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

210 J App Pharm Vol. 6; Issue 2: ; April, 2014 Mustafa et al, 2014

Permanent City Research Online URL:

Nitrate/Nitrite Assay Kit Manual Catalog #

Nitrate and Nitrite Key Words: 1. Introduction 1.1. Nature, Mechanism of Action, and Biological Effects (Fig. 1)

Supporting Information 3,4-Dihydroxyphenylalanine Peptides as. Nonperturbative Quantum Dot Sensors of

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

INFUSED SMOOTHIES MARY CLIFTON MD MEDICAL MARIJUANA & CBD OIL EXPERT ON MEDICAL MARIJUANA & CBD OIL

Development and Validation of Analytical Method for Determination of Andrographolide in Bulk Powder

INTERNATIONAL JOURNAL OF PHARMACY & LIFE SCIENCES

Q: How do I get the protein concentration in mg/ml from the standard curve if the X-axis is in units of µg.

O. Repeat the measurement in all relevant modes used in your experiments (e.g. settings for orbital averaging).

Transcription:

Potential and Limitations for Determining Lycopene in Tomatoes by Optical Methods Gordon E. Anthon and Diane M. Barrett Department of Food Science and Technology University of California Davis, CA 9566 USA Keywords: lycopene, tomato, color Abstract Lycopene in tomatoes and tomato products is routinely determined by extraction into organic solvents and spectrophotometric quantification. The direct determination of lycopene, by measuring the color or other optical properties of a tomato homogenate, would be an attractive alternative. We have evaluated two instruments for this purpose. The color of tomatoes and tomato products is routinely determined with a reflectance colorimeter such as a LabScan (Hunter Lab). We have examined whether the parameters determined with this instrument correlate sufficiently well with the lycopene content of raw tomato juice to allow for the prediction of lycopene levels. CIE a values were not linearly related to lycopene content but could be fit to a logarithmic regression line. A better, but still logarithmic, fit was obtained when the parameter optical density at 56 nm minus the optical density at 7 nm, was plotted versus lycopene. The absorbance of light transmitted through tomato juice was also measured with a Hunter Lab UltraScan. The parameter, absorbance at 56 nm minus absorbance at 7 nm was linearly related to the lycopene content of the tomato juice. The slope of the regression line, however, was affected by the method used to homogenize the tomato. Measured values for (A56-A7) were also substantially lower in cooked versus raw tomato juice samples that contained equal amounts of lycopene. Evidently, factors other than the total lycopene content greatly affect the absorbance values measured by the UltraScan. INTRODUCTION In tomatoes, lycopene is the principal carotenoid, comprising about 95% of the total, and is responsible for the red tomato color. Intuitively it seems apparent that the intensity of tomato color should correlate with the total lycopene content. Correlations between color, usually reported as CIE a value, and lycopene content have been reported and proposed as a way to estimate the lycopene content (Arias et al., 2; D'Souza et al., 992). In addition, direct measurements of light absorbance by tomato juice, at the wavelengths of maximum absorbance by lycopene, have also been shown to correlate with lycopene content. This also has been proposed as an alternative method for estimating lycopene in tomatoes (Davis et al., 23). Here we have evaluated these methods and examined some of the factors that may affect their usefulness. MATERIALS AND METHODS Tomatoes used to prepare fresh tomato homogenates were both processing types (evaluated in annual variety evaluation program; specific varieties not specified) and fresh market type ( Early Girl ). Homogenates were prepared either by grinding in a blender with added water (in some cases at a : ratio of water to tomato, in others at a 3: ratio), or by grinding in a mortar and pestle followed by passing through a screen to remove any large pieces of skin. Various dilutions of these homogenates were then examined. When homogenized in a blender, samples were allowed to stand for one hour prior to measuring to allow any air bubbles to completely dissipate. Microwave hot-break juice from tomatoes was prepared and stored frozen as described (Barrett and Anthon, 2). For Proc. 9 th IS on the Processing Tomato Ed. W.J. Ashcroft Acta Hort. 724, ISHS 26 243

optical measurements 5 g of juice was diluted to 2 ml with water. Absorbance measurements of the tomato homogenates and hot-break juice samples were made with an UltraScan XE (Hunter Associates Laboratory, Reston, VA), as described by Davis et al. (23). Measurements were made in transmittance mode using a 2 ml, cm path-length cuvette. The absorbance difference between 7 nm and 56 nm was then determined. The same samples were also analyzed with a LabScan (Hunter Associates Laboratory, Reston, VA), which measures reflected rather than transmitted light. From these measurements both the optical densities and CIE a values were determined. All measurements with both instruments were made in triplicate and averaged. Lycopene contents of the homogenates were determined by extraction in hexane:ethanol (3:4) and spectrophotometric quantification (Barrett and Anthon, 2). RESULTS AND DISCUSSION The ability of the UltraScan to determine lycopene levels was examined by preparing a series of homogenates from both fresh market and processing type tomatoes. Tomatoes were ground in a blender with various amounts of added water to produce homogenates with a range of lycopene contents, as determined by solvent extraction and spectrophotometric quantification. Following the procedure of Davis et al. (23), the absorbance difference between 56 and 7 nm (A56-A7) was then measured in the UltraScan and compared with the lycopene levels (Fig. A). A linear relationship between the absorbance difference and the lycopene content was found, in agreement with the results of Davis et al. (23). The slope of the regression line for homogenates prepared in a blender (.269) also agrees with the value reported by Davis et al. (.3) for fresh tomato homogenates. One difficulty encountered when preparing fresh tomato homogenates in a blender was the presence of air bubbles. Numerous air bubbles, which increase the light scattering and thus the measured absorbance of the sample, are present immediately after blending. To eliminate any effect these would have on the absorbance measurements, samples were allowed to sit for at least an hour between blending and absorbance measurements to allow the bubbles to dissipate. After this amount of time bubbles were no longer visually apparent and the measured absorbance values were stable. To avoid the introduction of bubbles we tried homogenizing the tomatoes with a mortar and pestle rather than a blender. Tomatoes homogenized in this way also showed a linear relationship between the absorbance difference and the lycopene content (Fig. B) but the slope of this line is only.79 or 63% of that obtained when a blender was used (Fig. A). Apparently, for a given lycopene content in a tomato, the absorbance of a homogenate, measured in the UltraScan, depends on the method used to homogenize the tomato. Factors other than the lycopene content, such as the particle size and other physical properties of the solution, must also exert a substantial effect. The biggest apparent difference between these two sets of samples was the finer particle size of the blender samples. A comparison of the complete absorbance spectra of a sample prepared in a mortar and pestle with that of one prepared in a blender gives some indication as to the origin of the discrepancy. Since blender samples give higher (A56-A7) values for a given amount of lycopene (Fig. ), it was possible to select two samples, one prepared in a mortar and pestle and one prepared in a blender, that had very different lycopene contents (6.3 and 43.4 mg/l respectively), yet gave similar (A56-A7) values of approximately.. The complete absorbance spectra of the two samples (Fig. 2) confirms that the absorbance difference between 56 nm and 7 nm is nearly the same (.4 and.75) in each. The big difference between the two spectra is that the background absorbance in the blender-prepared sample is higher and rises much more sharply with decreasing wavelengths. This rising baseline indicates that, in this sample, more of the absorbance measured at 56 nm is actually from background absorbance not lycopene. This would give a larger (A56-A7) value and explain the similarity in this value for the two samples despite the difference in lycopene contents. The same samples that were analyzed with the UltraScan were also examined with 244

a LabScan, which measures the amount of light reflected rather than absorbed. This is the commonly used method for measuring the color of tomato products for which results are reported as CIE L, a, b values or combinations of these parameters. A plot of the CIE a values versus lycopene content (Fig. 3A) shows that they are not linearly related to each other. A logarithmic regression line gives a reasonable fit to the data, which agrees with what others have reported (Arias et al., 2). A better correlation, although still not linear, was obtained by plotting optical densities rather than CIE a values. By analogy to the method used for UltraScan XE absorbances, the difference in optical densities between 56 and 7 nm was calculated to correct for optical density due to factors other than lycopene. A plot of this difference versus lycopene content (Fig. 3B) also gives a curve that can be fit with a logarithmic regression line. One advantage that the LabScan measurements appear to have over those obtained with an UltraScan is that the method used to homogenize the tomatoes has less of an effect on the measurement. Data from tomato homogenates prepared in both a blender and a mortar and pestle fall along the same regression line (Fig. 3) which was not the case when measurements were made in the UltraScan (Fig. ). In addition to looking at raw tomatoes, Davis et al. (23) examined the use of an UltraScan to determine lycopene in thermally processed tomato products. They showed that the parameter (A56-A7) was approximately linear with the amount of lycopene in the sample, although the correlation was not as good as with raw tomato homogenates. Significantly, the slope of the regression line was different for thermally processed and raw tomatoes, with processed tomatoes giving only about 75% as much of an absorbance difference for the same lycopene content. To examine the effect of thermal treatment, we determined the lycopene contents of a number of tomato homogenates, prepared either from raw tomatoes or from tomatoes given a microwave hot-break. Two homogenates with identical lycopene contents, one raw and one hot-break, were then selected and the UltraScan absorbance and LabScan optical density spectra determined. The spectra of the two samples are quite different, in spite of the fact that the lycopene contents of the two are the same (Fig. 4). At all wavelengths, and especially below 6 nm, the absorbance of the hot-break juice was substantially lower than that of the raw juice (Fig. 4A). The parameter, proposed by Davis et al. (23) as the measure of lycopene content, A56- A7, was only 59% as large for the hot-break sample versus the raw sample. Similarly, the optical density difference, OD56-OD7, was also only 56% as large in the hotbreak versus the raw sample (Fig. 4B). A possible explanation for this change in the absorbance spectrum due to heating may be that heat caused a significant amount of the trans-lycopene to isomerize to cislycopene, which has less absorbance. This does not appear to be the case, however. We measured the absorbance spectra of hexane extracts of the two samples and found them to be identical (data not shown). This indicates that no isomerization or other change in the lycopene resulted from the heating of the tomato juice. This agrees with the report of Nguyen and Schwartz (998) who showed, by HPLC methods, that trans-lycopene does not isomerize to any significant extent during thermal processing of tomato juice. The reason why the same amount of trans-lycopene gives a very different absorbance spectra (and visibly different color) in raw and cooked juices is at present unclear but presumably reflects changes in the tomato matrix caused by heating. CONCLUSIONS If samples are homogenized under carefully controlled conditions and optimally diluted it is likely that lycopene contents can be estimated to within a reasonable error by absorbance or reflectance measurements. The successful application of these methods, however, requires that the tomatoes be thoroughly homogenized, accurately diluted, transferred to a glass cell, and read in an analytical instrument. This is almost as many steps as in simple solvent based spectrophotometric methods (e.g. Barrett and Anthon, 2; Fish et al., 22). Other than avoiding volatile organic solvents and their associated costs, it is hard to see much of an advantage to these methods. An inherent limitation in 245

their use is the need to construct a calibration curve, for which solvent extraction and spectrophotometric determination will still be needed. Furthermore, since properties of the tomato matrix can have a strong effect on the optical measurements, lycopene determined by these optical methods will always be less certain than those determined by solvent extraction and direct measurement. ACKNOWLEDGEMENTS The authors thank Gordon Leggett of Hunter Labs for the loan of the UltraScan XE used in this work. This work was supported by funds from the California League of Food Processors. Literature Cited Arias, R., Lee, T.-C., Logendra, L. and Janes, H. 2. Correlation of lycopene measured by HPLC with the L*, a*, b* color readings of a hydroponic tomato and the relationship of maturity with color and lycopene content. J. Agric. Food Chem. 48:697-72. Barrett, D.M. and Anthon, G.E. 2. Lycopene content of California-grown tomato varieties. Acta Hort. 542:65-73. Davis, A.R., Fish, W.W. and Perkins-Veazie, P. 23. A rapid spectrophotometric method for analyzing lycopene content in tomato and tomato products. Postharvest Biol. Technol. 28:425-43. D'Souza, M.C., Singha, S. and Ingle, M. 992. Lycopene concentration of tomato fruit can be estimated from chromaticity values. HortSci. 27:465-466. Fish, W.W., Perkins-Veazie, P. and Collins, J.K. 22. A quantitative assay for lycopene that utilizes reduced volumes of organic solvents. J. Food Comp. Anal. 5:39-37. Nguyen, M.L. and Schwartz, S.J. 998. Lycopene stability during food processing. Proc. Soc. Exp. Biol. Med. 28:-5. 246

Figures A A56- A7 2.5.5 y =.269x -.4 A56-A7 B 2.5.5 y =.79x +.23 R 2 =.99 R 2 =.9387 2 4 6 8 2 4 6 8 Fig.. Absorbance difference between 56 and 7 nm, measured in the UltraScan XE, versus lycopene content of the tomato homogenate. A. Tomatoes homogenized in a blender. B. Tomatoes homogenized in a mortar and pestle. 3 Absorbance 2 4 5 6 7 nm Fig. 2. UltraScan absorbance spectra of tomato homogenates prepared either in a blender (solid line) or mortar and pestle (dashed line). The lycopene content of the blender sample was 43 mg/l; the mortar and pestle sample contained 6 mg/l. 247

A CIE a value 4 35 3 25 2 5 5 y =.537Ln(x) - 8.849 R 2 =.944 B OD56-OD7.4.2.8.6.4.2 y =.353Ln(x) -.3479 R 2 =.9732 2 4 6 8 2 4 6 8 Fig. 3. Analysis of raw tomato homogenates with a LabScan. A. CIE a value versus lycopene content. B. Optical density difference versus lycopene content. Closed symbols indicate homogenates made with a blender; open symbols, homogenates made with a mortar and pestle. A.8 B 2.5.5 2 Absorbance.2.9.6.3 Optical Density.5.5 4 5 6 7 4 5 6 7 nm nm Fig. 4. Comparison of the spectra of raw (solid lines) and microwaved (dashed lines) tomato samples. Both samples contained 25 mg/l lycopene. A. Absorbances measured in the UltraScan. B. Optical density measured in the LabScan. 248