ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

Similar documents
Field inspection of Phase-Array ultrasonic for polyethylene electrofusion joints

A Novel Phased Array Ultrasonic Testing (PAUT) System for On-Site Inspection of Welded Joints in Plastic Pipes

INSPECTION RESULTS OF DAMAGED POLYETHYLENE ELECTROFUSION JOINTS USING ULTRASONIC IMAGING METHOD

Inspection of Polyethylene Fusions and Electrofusions

Non-Destructive Inspection of Polyethylene Fusions and Electrofusions Dr. Ken Oliphant, P.Eng. and Dalton Crosswell, JANA Corporation

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer

INSPECTION THROUGH AN OVERLAY REPAIR WITH A SMART FLEXIBLE ARRAY PROBE.

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

Ultrasonic Phased Array for the Circumferential Welds Safety Inspection of Urea Reactor

CRACK DETECTION AND PIPELINE INTEGRITY SOLUTIONS

Numerical Modelling of Ultrasonic Phased Array Transducers and Their Application

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

COURSE DESCRIPTION FOR NONDESTRUCTIVE TESTING

Pipeline Technology Conference 2007

Ultrasonic Testing of Composite Structures

Approval and rejection criteria for Phased Array Ultrasonic Testing on PE electrofusion joints Suitable for diameters from 75 mm up to 250 mm

CHARACTERIZATION OF ANNULAR ARRAY TRANSDUCER

Optimization of Phased-Array Transducers for Ultrasonic Inspection in Composite Materials Using Sliding Probes

ADVANCED PHASED ARRAY TECHNOLOGIES

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders

SUITABILITY OF NON DESTRUCTIVE TECHNIQUES FOR TESTING POLYETHYLENE PIPE JOINTS. Peter J. Postma, René J.M. Hermkens, Kiwa Technology, The Netherlands

Feng Xiujuan National Institute of Metrology (NIM),China

Descriptions of NDT Projects Fall 2004 October 31, 2004

Automated ultrasonic testing of submerged-arc welded (SAW) pipes using phased-arrays

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Manual Ultrasonic Inspection of Thin Metal Welds

HiFFUT A New Class of Transducer

Application of portable Ultrasonic Phased Array Instrument for Rail Welds Ultrasonic Inspection Lao Jinjie a, Lu Chao b

Ultrasonic Phased Array Testing of Complex Aircraft Structures

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Developments in Ultrasonic Inspection II

10 Years Experience in Industrial Phased Array Testing of Rolled Bars

Ultrasonic Testing Level I:

Potential improvements of the presently applied in-service inspection of wheelset axles

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Intrinsically Safe Ultrasonic Testers: How important are they?

We are providing Level I, II Training and Certification as per Recommended practice SNT TC 1A 2006 in the following NDT Methods.

Linear Ultrasonic Wave Propagation in Biological Tissues

ADVANCE ULTRASONIC INSPECTION

DEVELOPMENT OF ULTRASONIC TESTING TECHNIQUE TO INSPECT CONTAINMENT LINERS EMBEDDED IN CONCRETE ON NUCLEAR POWER PLANTS

TTU Phased Array: Quality and Productivity

Introduction to Nondestructive Testing

Ultrasonic arrays are now widely used in underwater sonar

ACOUSTORAPHY Acousto-Optical (AO) Ultrasonics & Its Applications

Improved Inspection of Composite Wind Turbine Blades with Accessible Advanced Ultrasonic Phased Array Technology

Phased Array Ultrasonics and Eddy Current Examination for Graphite Components

Ultrasonic Testing of Rails Using Phased Array

Research on a Transmit-Receive Method of Ultrasonic Array for Planar Defects

Basic Physics of Ultrasound and Knobology

INTEGRATED QUALITY ASSURANCE PROGRAM FOR THE HYDRA-70 SOLID. LJ. Bond University of Denver Research Institute [DRl] Denver, CO 80208

Reliability Analysis of the Phased-Array Ultrasonic System used for the Inspection of Friction Stir Welds of Copper Canisters

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

Application of ultrasonic phased array in acoustic logging

ADVANCED NDE TECHNIQUES AND THEIR DEPLOYMENT ON HIGH PRESSURE EQUIPMENT

STUDY OF PHASED ARRAY TECHNIQUES FOR CONCRETE INSPECTION

WP Non-destructive testing of PE joints

Real Time 2D Ultrasound Camera Imaging: A Higher Resolution Option to Phased Array Bob Lasser Randy Scheib Imperium, Inc.

Detection. at first sight. One of the newest trends

Introduction to Nondestructive Testing. Outline

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

Underwater Acoustic Measurements in Megahertz Frequency Range.

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

ULTRASOUND SIMULATION HELPS TUBE MANUFACTURERS TO CALIBRATE THEIR NDT SYSTEMS S. Deutsch 1, B Bisiaux 1 and P. Gerard 2

1. SCOPE ELIGIBILITY EXAMINATION CONTENT RENEWAL & RECERTIFICATION PROCEDURE ESSENTIAL READING...

A CONTRIBUTION TO QUANTIFYING THE SOURCES OF ERRORS IN PAUT

ADVANCEMENTS IN NON DESTRUCTIVE TESTING

Ultrasonic Inspection of Adhesive Joints of Composite Pipelines

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.

Pressure Vessel Inspections Using Ultrasonic Phased Arrays By Michael Moles, Noël Dubé and Frédéric Jacques

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Ultrasound in Medicine

API. Defined Procedure. for. Ultrasonic Thickness Measurement API-UT-21

Ultrasonic Measurement of Aircraft Strut Hydraulic Fluid Level

Shcherbakov O.N., Petrov A.E., Polevoy A.G., Annenkov A.S. ULTES LLC, Moscow, Russia

Employer s Unit of Competence Ultrasonic testing of materials, products and plant

NON-CONTACT ULTRASOUND (NCU)

DIGITAL RADIOGRAPHY OF PE JOINTS

HAND HELD ULTRASONIC SIZING OF STRESS CORROSION CRACKING

Table 1: Samples used in experimental program. Block ID/thickness [ mm ]

COWLEY COLLEGE & Area Vocational Technical School

Qualification of Manual Phased Array Ultrasonic Techniques for Pipe Weld Inspection in Nuclear Power Plants

PART 1c: Time of Flight Diffraction Ultrasonic Inspector (TOFD) of Welds in Ferritic and Non-Ferritic Materials, Levels 1, 2 and 3

Other Major Component Inspection II

Controlled Cryogenic Ablation Using Ultrasonic Sensing

Inspection of High Temperature Pipe-work using Guided Waves Mark J. EVANS 1, Simon BUTLER 2

DEVELOPMENT OF ELECTROMAGNETIC ACOUSTIC TRANSDUCER (EMAT) PHASED ARRAYS FOR SFR INSPECTION

Case studies on uncertainties of ultrasonic weld testing interpretation

Oil Transmission Pipelines Condition Monitoring Using Wavelet Analysis and Ultrasonic Techniques

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

Flip Chips and Acoustic Micro Imaging: An Overview of Past Applications, Present Status, And Roadmap for the Future

Sensors & Transducers 2015 by IFSA Publishing, S. L.

Introduction to Nondestructive Testing

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis and Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRAINING PHANTOMS

Precise defect detection with sensor data fusion

Ultrasonic Thickness Procedure Pulse-Echo Thickness Gage TABLE OF CONTENTS. 1.0 Introduction Reference Documents Summary of Practice 2

PIPELINE INSPECTION AND INTEGRITY SOLUTIONS

THE DEVELOPMENT AND MANUFACTURE OF FIXED- ULTRASONIC INSPECTION REFERENCE REFLECTORS AND TRANSDUCERS FOR COMPRESSOR BLADE DOVETAILS

Transcription:

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING H. J. Shin 1, Y. H. Jang 1, J. R. Kwan 2, H. D. Lee 3 1 INDE System Co., Ltd., Suwon, Kyunggi-do, 440-746, South Korea 2 Korea Gas Safety Corporation, Kyunggi-do, 429-712, South Korea 3 Korea Institute of Construction Technology, Kyunggi-do, 411-712, South Korea ABSTRACT. Polyethylene is a widely used material for piping. Especially the demand of polyethylene piping for gas distribution is being increased. Thousands of kilometers of polyethylene piping have joints, and the joint is the weak point that should be inspected before the pipe begins service. In this study, an ultrasonic array technique is applied for the nondestructive testing of electrofusion joints in polyethylene pipe. An ultrasonic real time imaging system and array transducers are developed for the experiments. In the process of image construction, transmission and dynamic receive focusing are used. Heating wires are individually identified in ultrasonic real time images, which means that the ultrasonic array technology provides enough resolution to tell wire signals from flaw signals. Imperfect fusion joints and soil inclusion are clearly indicated in the images. Even locations of wires are appeared as is. The ultrasonic imaging technique is a very promising method for the nondestructive testing of EF joining of PE pipe. INTRODUCTION The demand of polyethylene (PE) pipeline increased in many field. A noncorrosive characteristic of PE is great benefits for the maintenance and extended periods of service life. Therefore the integrity of PE pipeline greatly depends on the quality of joints. Especially the PE pipeline for the gas energy distribution should be carefully constructed to prevent an explosive gas from leakage, and the rate of failure should be very low. Up to date efforts to have good joints were focused on the control of the joining process to follow proper procedure. A review of the electrofusion joining process for PE piping system was performed to have PE pipe system of a high integrity [1]. And intelligent, knowledge based system for EF welding was proposed [2]. To achieve the rate of failure close to zero, nondestructive testing (NDT) is strongly recommended in addition to joining process control. However, no wellknown nondestructive testing methods exist for the PE pipe fusion joints. This paper introduces a promising NDT method for electrofusion (EF) joining of PE pipe. EF joining is one of the widespread PE pipe weld methods. An estimated annual use of EF joining (in 1993) were over 15 million, and growing [1]. Figure 1 shows a) EF joining of two PE pipes with EF coupler b) a cross section of EF coupler. Spirally wound-heating wires exist between coupler and main pipes. The distance between adjacent wires is usually few (1~3) mm. The fundamental ideas of joining

process are to heat the wires and to melt the inside and outside surface of coupler and main pipes, respectively, then to consolidate fusion area. In this study, ultrasonic array technique was applied to obtain the real time ultrasonic images of the cross section of electrofusion joints. In the use of ultrasonic waves to inspect the electrofusion joint, the most difficult challenge was to distinguish the wound heating wire at the joint interface from the joint failure. An ultrasonic focusing technique was used with ultrasonic phased array system and 96elements of array transducers. Zone based transmission focusing and dynamic receiving focusing was used. And electronic scanning was used to obtain real time two dimension images of the cross section of the EF joints. Different types of flaw samples were made and tested. Finally, an NDT method for the PE pipe EF joining was proposed. (a) FIGURE 1. a) EF joining of two PE pipes with EF coupler. b) Cross section of EF coupler. Nominal radius of the main pipe is 50mm and nominal thickness of coupler is about 5mm. The center-to-center distance between wires is about 2.3mm and diameter of wire is about 0.5mm ULTRASONIC ARRAY TECHNOLOGY Ultrasonic array is one of the emerging techniques to enhance NDT quality. The preliminary study on the ultrasonic array technology for the EF joint were proposed very recently [3]. A dominant benefit of the array technique over the traditional ultrasonic technique is the capability to control ultrasonic radiation beam in real time by electronics, so that the real time two-dimensional images can be obtained. Figure 2 shows the simulation results of the ultrasonic radiation beam control by electronics for (a) focusing and steering and focusing. The focusing capability increases the inspection resolution dramatically. Figure 3 shows the electronic scanning concepts of ultrasonic beam for (a) lateral scanning by consecutive activation of array elements and dynamic depth scanning by the control of aperture size. The electronic scanning of focal point and beam path provide real time imaging capability. And the zone based transmission and dynamic receive focusing increase the signal to noise ratio [4, 5]. Basically the ultrasonic array technology greatly depends on the ultrasonic array electronics, transmission and reception beam forming algorisms, and array sensors [6-9]. Because the NDT results are obtained by real time 2D images, the NDT process using array technology is a lot faster and easier to interpret the inspection results in comparison with traditional A- and B-scan UT.

(a) FIGURE 2. (a) Ultrasonic beam focusing and ultrasonic beam steering and focusing with array technology. (a) FIGURE 3. (a) Lateral scanning of focal points by consecutive activation of array elements and dynamic depth scanning of focal points by the control of aperture size.

BASIC EXPERIMENTS AND EQUIPMENT In basic experiments, ultrasonic A-scan method was used. An average velocity of the PE was measured as 2.24 Km/s, and attenuation was measured as 3.5dB/cm and 6dB/cm at 1Mhz and 3.5MHz respectively. With a non-focused 5MHz traditional normal incident single element transducer and an ultrasonic pulse receiver, PANAMETRICS 5800, it was hard to detect back wall echoes of a PE piping thicker than 2cm. Also echoes from heating wire was small and the resolution was very poor to tell flaws from heating wires, since the gap between adjacent wires were too small as shown in Figure 1. Acoustic impedance of PE pipe was measured as 2329.6X10 3 pa s/m. For the NDT of the PE pipe EF joining in this study, an ultrasonic real time system and array transducers were developed. Figure 4 shows ultrasonic array transducers, each has 96 elements. The center frequency of the transducers determined as 3.5MHz, 5MHz, and 7.5MHz for the high penetration, general purpose, and high resolution respectively. Figure 5. shows a battery operated ultrasonic array system that is named AIM33. The system supports 96 array element transducers and has capability of real time 2D imaging, on screen sizing, image saving, and so on. The system could be connected with a B/W print, a PC monitor, and a head mount display. Therefore AIM33 is hand carry real field application system. (a) (c) FIGURE 4. Array transducer of 96 elements with the center frequency and dimension of (a) 3.5 MHz (120 X 80 X 40mm), 5 MHz (75 X 80 X 25mm), and (c) 7.5MHz (36 X 40 X 18mm). FIGURE 5. Battery operated ultrasonic array system, AIM33 (255 X 255 X 120mm, Approx. 4kg) developed by INDE System.

INSPECTION CONPTIONS FOR EF JOINTS Inspections are performed outside surface of the EF coupler as shown in Figure 5. Ultrasonic waves are focused and scanned underneath of the array transducer by ultrasonic array system. Heating wires reflects ultrasound and the wire signals are indicated in UT images. If the resolution of the ultrasonic beam is good, the heating wires are indicated individually, so that it is possible to count number of wires and to measure the distance between wires. Ultrasound is transmitted very well when the EF joint is good, in this case the fusion interface will not be detected in UT images. Imperfect fusion joints reflect ultrasound and the fusion interface will be detected in UT images. Fusion interface is forming underneath of wires, therefore the imperfect fusion interface signal will be detected underneath of wire signals in UT images. Also dislocation of wires and air or soil inclusions will be indicated in ultrasonic images. EXPERIMENTAL RESULTS Figure 6 (a) and show a good EF joint and its ultrasonic image that shows clear wire indications. All wires are individually indicated and the fusion interface is not indicated in the image, which means that the ultrasonic wave propagates very well through the interface. And the wire arrangement is well located as it should be. Figure 6 (c) and (d) show an imperfect EF joint and its ultrasonic image that shows the interface indication as well as wire indications. Because the fusion area is underneath of the wires, the imperfect interface signals are located underneath of wire indications. Figure 6 (e) and (f) show a over heated EF joint and its ultrasonic image that shows the dislocation of wire array. Figure 6 (g) and (h) show an EF joint with soil inclusion at the fusion interface and its ultrasonic image that shows the soil indication at the fusion interface area. CONCLUDING REMARKS Array technology provides good resolution and penetration power for the NDT of EF joint. In results, heating wires are individually identified in ultrasonic real time images, which means that the ultrasonic array technology provide enough resolution to tell wire signals from flaw signals. Imperfect fusion joints and soil inclusion are clearly indicated in the images. Even locations of wires are appeared as is. Therefore this array technology is a very promising method for the nondestructive testing of EF joining of PE pipe. In addition, the capability of real time displays makes the technology transfer to real field easy. ACKNOWLEDGEMENTS The author wishes to thank KOREA GAS SAFETY CORPORATION for the financial supports. The author also wishes to DAEYOUN MOLD INDUSTRIAL CO., LTD. and POLYTEC CO., LTD. for the making of various EF joining samples.

(a) (c) (d) (e) (f) (g) (h) FIGURE 6. The pictures of cross section of various EF joint samples are shown in (a) good joint (c) imperfect joint (e) over heated joint (g) soil inclusion joint, and the corresponding ultrasonic images are shown in (d) (f) (h) respectively.

REFERENCES 1. Bowman, J., A Review of the Electrofusion Joining Process for Polyethylene Pipe System, Polymer Engineering and Science, Vol. 37, No 4, pp.674-691 (1997). 2. Torsun, I.S., Day, A.J., Wood, A.S., Dib, N., Rosala, G.F., Folkers, M.J., and Hinchcliff, F.A., Intelligent Knowledge Based System for Electrofusion Welding of Polyethylene Pipes, Plastic, Rubber and Composites Processing and Applications, Vol 25, No. 4, p. 191 (1996). 3. Shin, H.J., Kwan, J.-R. and Song, S.-J., Ultrasonic Real Time Imaging Technique for the Inspection of Electrofusion Joints for Polyethylene Piping, 2001 Forum for Gas Safety, edited by Korea Gas Safety Corporation, KGS 2001-069, 2001 September 27, p.21 4. Song, S. J., Shin, H. J., Jang, Y. H., 1999. Ultrasonic Phased Array Transducers for Nondestructive Evaluation of Steel Structures, in 26 th Review of Progress in Quantitative Nondestructive Evaluation, edited by D. O. Thompson and D. E. Chimenti, AIP Conference Proceedings 509, 1999, vol. 19A, pp. 1079-1086. 5. Hwang, J. S., Shin, H. J., Song, S. J., Song, T. K., 1999. Digital Phased Array Ultrasonic Inspection System with Dynamic Focusing, 26 th Review of Progress in Quantitative Nondestructive Evaluation, 26 th Review of Progress in Quantitative Nondestructive Evaluation, edited by D. O. Thompson and D. E. Chimenti, AIP Conference Proceedings 509, 1999, vol. 19A, 1087-1093. 6. Kino, G. S.,. Acoustic waves : devices, imaging, and analog signal processing, Englewood Cliffs, NJ: Prentice-Hall, (1987). 7. Mucci, R. A., A Comparison of Efficient Beamforming Algorithms, IEEE Trans. Acoust. Speech Signal Processing, ASSP-32, 548-558, (1984). 8. Clay, A. C., Wooh, S. C., Azar, L., Wang, J., Experimental Study of Phased Array Beam Steering Characteristics, Journal of NDE, Vol. 18, No. 2, 59-71,(1999). 9. Wooh, S. C., Shi, Y., A Simulation of the Beam Steering Characteristics for Linear Phased Arrays, Journal of NDE, Vol. 18, No. 2, 39-57, (1999).

Keyword List Array ultrasonic, Polyethylene (PE), Electrofusion (EF) joining, Ultrasonic Image, Gas piping