IN-VITRO STUDY OF FILTERING EFFICIENCY IN VENA CAVA FILTERS

Similar documents
Clinical Guide - Inferior Vena Cava Filters (Reviewed 2006)

Inferior Vena Cava Filters- Are they Followed up? By Dr Nathalie van Havre Dr Chamica Wijesinghe Dr Kieren Brown

Spontaneous Tilting after Placement of the Gu nther-tulip Inferior Vena Caval Filter: A Case Report 1

Impact of Unilateral Common Iliac Vein Occlusion on Trapping Efficacy of the Greenfield Filter: An in Vitro Study 1

Indications. The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli

Optimal Filter Placement

Inferior Venacaval Filters Valuable vs. Dangerous Valuable Annie Kulungowski. Department of Surgery Grand Rounds March 24, 2008

Inferior Vena Cava (IVC) filter insertion. An information guide

IVC filter retrieval program effects on retrieval rates and number of patients lost to follow-up

IVC FILTERS: A CASE REPORT REVIEWING THE INDICATIONS FOR PLACEMENT, RETRIEVAL AND ANTICOAGULATION

Expanding Horizons: AngioVac Suction Thrombectomy at UTHealth

Inferior Vena Cava Filter Retrieval

Special comment. (inferior vena cava filter, IVCF) Mobin-Uddin % [4] 1 IVCF

Carry this card with you at all times. Show this card to any medical professional treating you. Patient Implant Card. Option ELITE Vena Cava Filter.

Percutaneously Inserted AngioVac Suction Thrombectomy for the Treatment of Filter-Related. Iliocaval Thrombosis

THROMBOEMBOLIC EVENTS AFTER IVC FILTER PLACEMENT IN TRAUMA PATIENTS. Lidie Lajoie, MD SUNY Downstate Department of Surgery December 20, 2012

Inferior Vena Cava Filter for DVT

NOTE: Deep Vein Thrombosis (DVT) Risk Factors

IVC Filters: For Whom, Why and When?

I am NOT: Disclosures. The Problem of the Con-Position Non Thinking! Against New Ideas. Against New Therapies. Against Endovascular Therapies

PREVENTION AND TREATMENT OF VENOUS THROMBOEMBOLISM

Sample page. POWER UP YOUR CODING with Optum360, your trusted coding partner for 32 years. Visit optum360coding.com.

Perforated inferior vena cava filter removal by concurrent femoral and internal jugular vein approaches

Meissner MH, Gloviczki P, Comerota AJ, Dalsing MC, Eklof BG, Gillespie DL, et al. J Vasc Surg. 2012;55:

INFERIOR VENA CAVA FILTERS QUIZ 10 QUESTIONS MAY 5, 2014

M Johnson Disclosures

VIVO-EU Results: Prospective European Study of the Zilver Vena TM Venous Stent in the Treatment of Symptomatic Iliofemoral Venous Outflow Obstruction

IVC Filters: Rate of Insertion, Indications, Effects on Prognosis, Evidence Basis for Current Practices. Paul D. Stein, MD

Straub Endovascular System &

STRUT PERFORATION OF INFERIOR VENA CAVA FILTERS. Robert Herbert. Department of Mechanical Engineering. The Ohio State University.

J Jpn Coll Angiol, 2009, 49:

Deep Venous Thrombosis, Pulmonary Embolus and IVC Filters. Michael Meuse, M.D. Vascular and Interventional Radiology

Case Report Aspiration Thrombectomy in a Patient with Suprarenal Inferior Vena Cava Thrombosis

Supplementary Online Content

Endovascular treatment of acquired arteriovenous fistula with severe hemodynamic effects: a case report

with Vena Caval Umbrella

Intervention for Deep Venous Thrombosis and Pulmonary Embolus

Information for patients. Vena Cava Filters. Sheffield Vascular Institute. Northern General Hospital

ORIGINAL INVESTIGATION. Indications, Complications, and Management of Inferior Vena Cava Filters

EKOS. Interventional Vascular 3 February, Imagine where we can go.

Case-based topics to touch on Beware of devices that sit in veins. Asymptomatic PE management conundrum. nd Should we be testing for hypercoagulabilit

Division of Vascular Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 2

Complex Iliocaval Reconstruction PNEC. Seattle WA. Bill Marston MD Professor, Div of Vascular Surgery University of N.

Percutaneous Mechanical Thrombectomy for Acute Iliofemoral DVT with the Aspirex Catheter: The Dijon Experience

Inferior Vena Cava Filters

B. Tardy*, P. Mismetti**, Y. Page*, H. Décousus**, A. Da Costa +, F. Zeni*, G. Barral ++, J.C. Bertrand*

(This is a sample cover image for this issue. The actual cover is not yet available at this time.)

CHAPTER 4 Basic Physiological Principles

Complications of Inferior Vena Caval Filters

Catheter-Related Thrombosis A Catalyst of Complications

Acoustic Pulse Thrombolysis Treatment

Case Endovascular management of non maturing dyalisis vascular access

Chronic Thromboembolic Pulmonary Hypertension (CTEPH): A Primer

22F coil-reinforced cannula. Designed with a balloon actuated, expandable funnel shaped distal tip

Understanding of the importance of venous

Intro: Slide 1. Slide 2. Slide 3. Basic understanding of interventional radiology. Gain knowledge of key terms and phrases

Deep Vein Thrombosis

368 Computational Modeling of Renal Vein Inflow with IVC Filters March 2010 JVIR crease in deep vein thrombosis 8 years after placement of a permanent

Catheter Tip Design. Disclosure. In Vitro Performance of Long-Term Hemodialysis Catheters. ASDIN 10th Annual Scientific Meeting Final

VTE in the Trauma Population

Surgical approach for DVT. Division of Vascular Surgery Department of Surgery Seoul National University College of Medicine

Emerging Tools for Lytic-Free, Single-Session Treatment of Venous Thromboembolic Disease

Reducing Thrombotic Burden in Arterial Interventions. Mario Galli, MD Cardiovascular Interventional Unit S. Anna Hospital, Como, Italy

Properties and modelling of the venous blood flow. 1111, Budapest, Műegyetem rkp. 3. D ép. 3. em Tel: Fax:

Inferior vena cava (IVC) thrombosis is along the clinical

Bare Metal Stents vs Stent Grafts

PREVENTION AND TREATMENT OF VENOUS THROMBOEMBOLISM

BEDSIDE ULTRASOUND BEDSIDE ULTRASOUND. Deep Vein Thrombosis. Probe used

Cover Page. The handle holds various files of this Leiden University dissertation.

Technique de recanalisation: mon expérience avec Aspirex

Corresponding Author: Dr. Kishan A Bhgwat

Clinical Commissioning Policy Statement: Patent Foramen Ovale (PFO) Closure. April Reference: NHSCB/A09/PS/a

A Primer on Central Venous Access: Peripherally-Inserted Central Catheters, Tunneled Catheters, and Subcutaneous Ports

Top Ten Reasons For Failure To Prevent Postoperative Thrombosis

Minimally Invasive Thrombectomy Using the AngioVac System. Brian J. deguzman, MD AmSECT Tampa, FL April 14, 2015

Deep Vein Thrombosis

DISORDERS OF VENOUS SYSTEM

The hallmark of percutaneous thrombus management

How to best approach chronic venous occlusions?

Transcatheter closure of patent foramen ovale using the internal jugular venous approach

Blood Vessels. veins. valve. to the heart. capillaries from the heart. arteries. Visual 25-1

Mabel Labrada, MD Miami VA Medical Center

Pharmaco-mechanical techniques stand alone procedures? Peter Neglén, MD, PhD SP Vascular Center Limassol Cyprus

Venous interventions in DVT

Challenging Case of Pulse Infusion Thrombolysis Using a Unique Pump System for a Patient With Deep Vein Thrombosis: A Case Report

VENOUS THROMBOEMBOLISM: DURATION OF TREATMENT

Guidelines, Policies and Statements D20 Statement on Peripheral Venous Ultrasound

2019 ABBOTT REIMBURSEMENT GUIDE CMS Physician Fee Schedule

Innovative Endovascular Approach to Pulmonary Embolism by Ultrasound Enhanced Thrombolysis. Prof. Ralf R.Kolvenbach MD,PhD,FEBVS

Complex Retrieval of Embedded Inferior Vena Cava Filters in Interventional Radiology

Is it Necessary to Verify Blood Return in Monthly Port Flushes?

Bard Meridian Filter Fracture

Introducer Curving Technique for the Prevention of Tilting of Transfemoral Günther Tulip Inferior Vena Cava Filter

The hallmark of percutaneous thrombus management

Ultrasound-enhanced, catheter-directed thrombolysis for pulmonary embolism

What is the real place of venous echo Doppler in aircrew member flying rehabilitation after a thromboembolism event?

Closed-loop CFD Model of the Self-Powered Fontan Circulation for the Hypoplastic Left Heart Syndrome

Diagnosis and Treatment of Deep Venous Thrombosis and Pulmonary Embolism

Versatility and Proven Safety

We Catch. What Others Miss

Transcription:

IN-VITRO STUDY OF FILTERING EFFICIENCY IN VENA CAVA FILTERS Marcelo Peixer Corbellini, corbellini@labcet.ufsc.br Amir Antônio Martins de Oliveira Jr., amir.oliveira@gmail.com Universidade Federal de Santa Catarina, Centro Tecnológico, Departamento de Engenharia Mecânica, Campus Universitário, Trindade, Florianópolis, Santa Catarina, Brasil Fernando Marcelo Pereira, fernando@biokyra.com Universidade Federal do Rio Grande do Sul, Escola de Engenharia, Departamento de Engenharia Mecânica, Rua Sarmento Leite 425, Cidade Baixa, Porto Alegre, Rio Grande do Sul, Brasil Abstract. Inferior vena cava filters are used in order to avoid pulmonary embolism. Three commercial vena cava filters were evaluated for their clot trapping efficiency and pressure loss due to insertion of blood clots. An in vitro flow circulation system was built with a simulated inferior vena cava. Blood thrombi were made from fresh bovine blood and cut into different lengths. Blood clots were inserted in the system and the clot trapping efficiency was measured by computing the clots trapped by the filters. Pressure loss was measured with an open manometer as clots were inserted in the system. Results indicate a notable increase in efficiency as longer clots are used in the experiments. For a larger number of blood clots (>3) a strong decrease in filter efficiency is observed. There was no difference in the pressure loss measured for the first ten clots among the filters tested and a higher pressure was measured for larger number of captured thrombi. In conclusion, we have found no significant difference in the clot trapping efficiency among the filters but different values for the pressure loss and clot trapping efficiency for larger numbers of captured thrombi. Keywords: pulmonary embolism, inferior vena cava filters, clot trapping efficiency, pressure loss. 1. INTRODUCTION Pulmonary embolism (PE) is a potential deadly disorder caused by migration of blood clots and subsequent occlusion of a pulmonary artery. In the USA, over 2, fatal cases of PE are registered every year (Horlander, 23). Inferior vena cava (IVC) filters have been used to prevent PE by mechanical trapping of dislodged thrombi in cases of failed or contra-indicated anticoagulation treatments for patients with deep venous thrombosis (Kaufman, 29; Hammond, 29; Aziz, 2). Several characteristics have been recognized for an ideal IVC filter as: high filtering efficacy with no impedance of flow, non thrombogenic and retrievable (Kinney, 23). Despite the presence of several inferior vena cava filters in the market it is stated that the ideal filter has not yet been developed (Kinney, 23; Lorch, 22). Thus, a crucial factor in selecting a vena cava filter is how efficiently a filter can capture risky thrombi. Clinical trials are usually the last stage in the medical product development process, however, these studies have limitations, especially for the numerous different clinical variables encountered among patients, which makes results comparison difficult (Becker, 1992). In order to have a more stable condition, we have developed an experimental setup for the evaluation of inferior vena cava filters. In this experiment the clot trapping efficiency of three commercial filters was studied. The filters are: Tulip (Cook Medical Inc., Bloomington, IN, USA), (Cordis Corporation, Bridgewater, NJ, USA) and ( Biomédica, Ribeirão Preto, Brazil). 2. MATERIAL AND METHODS 2.1 In vitro model The in vitro model consists of four components: 1) circulation system, 2) IVC model, 3) thrombi insertion section and 4) manometer (Fig. 1). The circulation system is driven by a physiologic flow simulator pump (PhysioPulse, Shelley Medical Imaging Technologies). The pump is computer controlled and allows precise flow regulation. The simulated IVC model is made of round, transparent Tygon tubing (Saint Gobain, Les Miroirs, Courbevoie, France). Its inlet is connected to the insertion section, that is a glass bifurcation simulating the confluence of the iliac veins having a side-port for thrombi insertion without interruption of flow. An open manometer is used to measure pressure immediately before and after the test section. Static pressure at location is maintained at -15 cmh2o by adjusting the height of outflow port. The blood is simulated by a 32 % (mass) solution of glycerin. The density of this working fluid is 1,7 g/cm3 and its viscosity is 2,51 Pa.s which corresponds to that of blood (Waite and Fine, 27, p. 15). Thrombi were made from fresh bovine blood inserted in 3 and 5 mm round glass tubes and allowed to coagulate within 24 hours. The filled glass tubes were refrigerated at 4 ºC prior to use.

Computer Manometer Fluid reservoir Vena cava filter Pump Thrombi inserction section IVC model Figure 1. In vitro model for inferior vena cava filter testing. 2.2 Experimental parameters All three vena cava filters were tested in an ideal nontilted horizontal position of the flow model in a 28 mm IVC tube. A constant fluid flow of 2 lpm is used during the efficiency and pressure tests. The 3 mm diameter thrombi were cut in length of 6, 11, 16 and 21 mm and used for the efficiency tests. The 5 mm diameter thrombi were cut in 35 mm length for the efficiency and pressure tests. 2.3 Testing protocols 2.3.2 Filter efficiency Ten clots of the same size were serially introduced into the system and their progress was observed. A clot was considered captured when it was retained in the filter for at least one minute. Capture was recorded independently for each clot in a sequence and the total of clots retained in the filter after each run was computed. The test was repeated times for every combination of filter and clot size (3x6; 3x11; 3x16; 3x21 mm). 2.3.1 Pressure loss and sequential test Up to fifty clots were sequentially introduced into the system as the pressure change was computed for every captured clot. The test was interrupted when one of the situations occurred: fifty clots were introduced; the pressure loss was higher than 2 cmh2o; the filter did not capture any clot in a sequence of ten clots; the filter migrates until the end of the test section. The test was repeated three times for every filter. The sequential test is the efficiency for the first ten introduced clots compared to the total number of clots introduced during the pressure loss protocol. 3. RESULTS AND DISCUSSION 3.1 Efficiency measurements The in vitro clot trapping efficiency of the three vena cava filters are presented in Fig. 2 and Fig. 3.

Clot trapping efficiency (%) 9 8 7 6 5 4 3 2 Clot trapping eficiency (%) 9 8 7 6 5 4 3 2 6 mm 11 mm 16 mm 21 mm Thrombi lenght (mm) Figure 2. Filter efficiency of the tested vena cava filters. 2 3 4 5 Inserted clots Figure 3. Sequential filter efficiency for the tested vena cava filters. There is notable difference of efficiency according to the length of the blood clots as shown in Fig. 1. filter was most effective (18%) when tested with 6 mm thrombi. For 11, 16 and 21 mm efficiency was 34, 58 and 81% respectively. had the best efficiency for the longest clots (83%) and 57, 27, 17% efficiency as thrombi decreased in length. had the best performance for 11 and 16 mm clots (36 and 7% respectively) and efficiency of 78 and 15% for 21 and 6 mm clots. It is observed a variation of efficiency according to blood clot length. However results don t indicate important difference of efficiency when filters are compared for the same test conditions. The length of the clots directly affects the filter efficiency since clot hydrodynamics is altered as its length increases. There is a tendency of clots to drape more easily around the filter structures because of a possible transverse clot orientation at the moment of the impact with the filter. It was observed that clots that reach the filter in a parallel orientation to the flow tend not to be captured by the filter. Several experimental studies have been conducted to evaluate the vena cava filters mentioned in this study (Xian, 1995; Lorch, 22; Stoneham, 1995;, 25). However, results cannot be compared or extrapolated from one study to another since a standardized experimental protocol has not yet been defined. Although the exact number and size of thrombi proved to be human lethal is not identified, it is known that large thrombi (> 7 mm) are easily captured by vena cava filters. In order to perform a comparative study we used the 3 mm thrombi, which associated with a large size of vena cava (28 mm) and low flow velocity (2 L/min.) simulate a critical condition for clot capture. A good filter performance in these conditions indicates better results with more favorable parameters. Figure 3 shows clot trapping efficiency for the first ten and for all clots inserted (5 mm thrombi). All filters had a great decrease in clot trapping ability as efficiency was computed from all inserted clots. and had a high efficiency for the first ten clots ( and 97%, respectively) while was 73% efficient. As efficiency was calculated for all inserted thrombi, efficiencies decreased to 38% (), 55% () and 57% (). These findings indicate poor filter efficiency in the presence of a large thrombic load. The same pattern was noted by Xian et al (1995). We observed that as the capture section was being fulfilled a high velocity flow channel was created where the subsequent thrombi were preferentially passing through. As early this channel was created the steepest was the slope of the curves which indicate the inability of the filter to capture high volumes of thrombi. 3.1 Pressure measurements Figure 3 shows pressure loss measured for the vena cava filters. As expected, pressure loss was higher as more thrombi were captured. For all filters there is no significant difference in pressure loss until ten or less thrombus were captured. However, a significant difference was noted as filters were able to capture more than ten clots. Higher pressure measurements were registered for filter as the maximum pressure was 15.3 cmh2o for 22 captured clots. filter reached a pressure of 9.1 cmh2o maximum for 27 captured clots. was able to capture only 11 clots as ten sequential inserted clots were not captured. Maximum pressure in this condition was 2. cmh2o. An influence of the filter in pressure measurements was noted for the test.

18 16 Differential pressure (cmh2o) 14 12 8 6 4 2 2 4 6 8 12 14 16 18 2 22 24 26 28 3 Trapped clots Figure 4. Differential pressure caused by clot insertion for the tested vena cava filters. It is notable that no significant difference was observed for the clot trapping efficacy of the vena cava filters. However as blood clots volume increased (>3) there was a difference in efficiency and pressure loss measured for all three tested vena cava filters. 4. CONCLUSION The efficiency of all tested vena cava filters decreased as shorter clots were used. As length of thrombi influences efficiency of vena cava filters, filters might not be efficient to prevent pulmonary embolism caused by numerous small clots. Filters also showed a drastically decrease in efficacy when a large embolic load was used, and differential pressure increased as clots were inserted in the test section, which restricts the use of these vena cava filters in patients in advanced stages of deep venous thrombosis. 5. REFERENCES Aziz, F., Comerota, A.J., 2. Basic Data Underlying Clinical Decision-Making in Endovascular Therapy. Annals of Vascular Surgery, 24: 966-979. Becker D.M., Philbrick J.T., Selby J.B., 1992. Inferior vena cava filters: indications, safety, and effectiveness. Archives of Internal Medicine, 152:1985-1994., D.M., Godoy, J.M.P., Centola, M., 25. Avaliação in vitro de um novo filtro de veia cava. Jornal Vascular Brasileiro, 4:327-32. Hammond, C.J. et al., 29. Audit of the use of IVC filters in the UK: experience from three centres over 12 years. Clinical Radiology, 64:52-5. Horlander K.T., Mannino D.M., Leeper K.V., 23. Pulmonary embolism mortality in the United States, 1979-1998: an analysis using multiple-cause mortality data. Archives of Internal Medicine, 163(14):1711-7. Kaufman, J.A. et al., 29. Development of a Research Agenda for Inferior Vena Cava Filters: Proceedings from a Multidisciplinary Research Consensus Panel. Journal of Vascular and Interventional Radiology, 2:697 77. Kinney T.B., 23. Update on inferior vena cava filters. Journal of Vascular Interventional Radiology, 14:425 44. Lorch, H. et al., 22. Efficacy of Permanent and Retrievable Vena Cava Filters: Experimental Studies and Evaluation of a New Device. Cardiovascular Interventional Radiology, 25:193 199. Stoneham, G.W., Burbridge, B.E., Millward, S.F., 1995. Temporary Inferior Vena Cava Filters: In Vitro Comparison with Permanent IVC Filters. Journal of Vascular and Interventional Radiology, 6:731-736. Waite, L, Fine, J., 27. Applied Biofluid Mechanics. New York: McGraw Hill. 314p.

Xian, Z.Y. et al., 1995. Multiple Emboli and Filter Function - An in Vitro Comparison of Three Vena Cava Filters. Journal of Vascular and Interventional Radiology, 6:887-893. 6. RESPONSIBILITY NOTICE The authors are the only responsible for the printed material included in this paper.