Quantitative Determination of Terpenes in Cannabis Using Headspace Solid Phase Microextraction and GC/MS

Similar documents
AppNote 5/2010. A Novel Automated Blood Analyzer for the Determination of Immunosuppressants in Whole Blood INTRODUCTION

AppNote 3/2013. Automated Determination of Total Fat, Saturated Fat, Monounsaturated Fat and Trans Fat Content in Food Samples KEYWORDS ABSTRACT

AppNote 3/2008. Determination of Aldehydes and Ketones in Oily Matrices using a Novel Dynamic Headspace Sampler Coupled to GC/MS INTRODUCTION

Direct Thermal Extraction Analysis of Food Packaging Material

AppNote 1/2005. Blood Alcohol Analysis Using an Automated Static Headspace Method ABSTRACT

AppNote 4/2002. Stir Bar Sorptive Extraction: Capacity and Competition Effects KEYWORDS ABSTRACT. SBSE, SPME, capacity

KEYWORDS ABSTRACT. 3-MCPD, Glycidol, edible oil, lab automation, ISO , AOCS Cd 29c-13, DGF C-VI 18 (10)

AppNote 10/2002. Detection of Spoilage Markers in Food Products using a Mass-Spectrometry Based Chemical Sensor KEYWORDS ABSTRACT

KEYWORDS ABSTRACT AppNote 3/2002

AppNote 1/2015. Automated Sample Preparation for Metabolomics Studies Using the Gerstel MPS Dual Head WorkStation

AppNote 4/2015. Automated Desorption, SPE Extraction, and LC/MS/MS Analysis of Dried Blood Spots KEYWORDS ABSTRACT

AppNote 8/2007. Rapid Multidimensional GC Analysis of Trace Drugs in Complex Matrices KEYWORDS ABSTRACT

Automated Hydrolysis, Extraction and Determination of Opioids in Urine using a Novel Robotic Autosampler and LC-MS/MS Platform

AppNote 3/2001. Elimination of Polar Matrix Components Prior to GC Analysis using Stir Bar Sorptive Extraction (SBSE) KEYWORDS ABSTRACT

AppNote 5/2012. Qualitative Analysis of Coconut Water Products using Stir Bar Sorptive Extraction Combined with Thermal Desorption-GC/MS KEYWORDS

AppNote 9/2000. Flavor Profi ling of Different Olive Oils with Rancidity-Monitoring by Thermal Extraction GC/MS KEY WORDS ABSTRACT

Drugs of Abuse in Oral Fluids: Automated SPE Extraction and LC/MS/MS Determination using a Robotic Autosampler

AppNote 11/2008. Analysis of Drugs and Metabolites in Blood and Urine using Automated Disposable Pipette Extraction KEYWORDS ABSTRACT

2-Step Multi-Volatile Method (2-Step MVM) for Characterization of Aroma Compounds in Bread

AppNote 2/2014. Fully Automated SPE-GC/MS Determination of Δ9-Tetrahydrocannabinol (THC) and its Metabolites in Serum Samples KEYWORDS ABSTRACT

AppNote 4/1994. Identification of Furan Fatty Acids as Minor Components of Human Lipids by Multidimensional GC-MSD

AppNote 1/1995. Quantification of 4-Heptanone in Urine by Headspace GC-MS Analysis Using a Multipurpose Sampler

AppNote 5/2013. Thermochemolysis A Simple and Rapid Methylation Method Based on TMAH for Gas Chromatographic Analysis of Linseed Oil and Amber

using the Agilent 7696A Sample Prep

AppNote 11/2006. Performance Evaluation of a Thermal Desorption System for Detection of Basic Drugs in Forensic Samples by GC/MS KEYWORDS ABSTRACT

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds

AppNote 6/1994. Identification of Furan Fatty Acids in Nutritional Oils and Fats by Multidimensional

AppNote 3/1993. Identification of Fatty Acid Methyl Esters as Minor Components in Fish Oil by Multidimensional GC-MSD: New Furan Fatty Acids

Simplified Cannabis Terpene Profiling by GCMS

Restek PAL SPME Fibers cat.#

Interested in conducting your own webinar?

AppNote 6/1996. Analysis of Plasticizers in Medical Products by GC-MS with a Combined Thermodesorption - Cooled Injection System

SPME-LC Fibers for a Variety of Applications

Forensic Analysis of Blood Alcohol Concentration

The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample

Innovations in Large Volume Injection

Analysis of short chain organic acids in tobacco and in some flavored e-liquids

Agilent GC-MS: Headspace-GC-MS systems for the analysis of Residual Solvents and Terpenes

LC-MS/MS Method for the Determination of Tenofovir from Plasma

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

Rapid and Robust Detection of THC and Its Metabolites in Blood

Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

Improving The Quality And Efficiency Of Terpene Extraction From Cannabis Plant

Comparison of PAL SPME Fibers with established Fibers

Analysis and Quantitation of Cocaine on Currency Using GC-MS/MS. No. GCMS No. SSI-GCMS-1501

Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note Introduction

Analysis of Cannabinoids in Cannabis by UHPLC Using PDA Detection

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

CANNABIS ANALYTICS. Toward a Chemotype-Based Labeling System

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column

Pesticide analysis in Hops and Cannabis by GC-MS-MS

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Modified QuEChERS Procedure for Analysis of Bisphenol A in Canned Food Products

Quantitation of Four Regulated Phthalates in Plastic Consumer Products by Gas Chromatography Time-of-Flight Mass Spectrometry

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

AppNote 3/2001. Elimination of Polar Matrix Components Prior to GC Analysis using Stir Bar Sorptive Extraction (SBSE)

GC/MS Identification of Flavor and Fragrance Allergens in Some Common Snack Foods Using an Agilent J&W DB-17ms Capillary GC Column

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Medical Cannabis Terpene Measurement using the SRI 8610C FID GC

Off-flavour Analysis in Food Using a Simple and Rapid SPME-GC/TQMS Method with Dedicated Off-flavour Database

GC-µECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Analyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol

From passive sampling of sediment to lipid based concentrations

12025 NE Marx St. Portland, OR Green Leaf Lab proudly follows / ISO/IEC 17025:2005(E) Quality Standards

Possibility of Use a Saliva for Determination Ethanol and Opiates

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff

Determination of Allergens in Fragrance Products Using Agilent Deconvolution Reporting Software Application Brief

Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column

Method Development and Research for Measuring Emissions from Spray Polyurethane Foam (SPF) Insulation. John Sebroski, Bayer MaterialScience LLC

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Type Analysis of Citrus Essential Oils by Multidimensional Supercritical Fluid Chromatography/ Gas Chromatography

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Rapidly Analyze a Wide Range of Glycol Ethers by GC-MS Using the New Rxi -1301Sil MS Column

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data

New GCMS Applications

Determination of Residues of 1,3-Dichloropropene in Grapes by Capillary Gas Chromatography with Mass Selective Detection

Analysis of Cannabinoids in Hemp Seed Oils by HPLC Using PDA Detection

Author. Introduction. Abstract

Life Science and Chemical Analysis Centre. John Heim

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Analysis of Cannabinoids in Hemp Seed Oils by HPLC Using PDA Detection

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Sue D Antonio Application Chemist Cedar Creek, TX

GE Healthcare Life Sciences. Quality matters. Whatman TM filters for air monitoring

A comparison study of the analysis of volatile organic acids and fatty acids

MALAYSIAN MALAYSIAN COCOA WORKSHOP ON THE SAFE USE OF PESTICIDES IN COCOA AND HARMONIZED

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS

Key Advantages of Comprehensive Cannabis Analysis

Improved Characterization of Perfumes with GC GC-TOFMS

Transcription:

Quantitative Determination of Terpenes in Cannabis Using Headspace Solid Phase Microextraction and GC/MS Michael Halpenny, Katherine K. Stenerson MilliporeSigma, 595 North Harrison Road, Bellefonte, PA 16823, USA INTRODUCTION Well known for their characteristic flavor and fragrance characteristics, terpenes are contained in the derived essential oils of cannabis. Analysis of cannabis for terpene concentrations can be applied to strain identification, referred to as fingerprinting, and for concentration accuracy when applied to medicinal treatments. Terpenes have high vapor pressures, are extremely volatile and thus are an excellent candidate for static headspace GC analysis. In this work, headspace SPME (HS-SPME) was combined with GC/ MS for the quantitative analysis of several selected terpenes in cannabis. The conventional approach for terpene analysis in cannabis involves a solvent extraction followed by GC/FID analysis. HS-SPME offers several advantages over the solvent extraction method in that it is non-destructive to the sample, requires a very small sample size, produces minimal interference from co-extracted matrix, protects the GC instrument from contamination, and can be easily automated. EXPERIMENTAL Three terpenes were selected for quantitative measurement by HS-SPME: -Pinene, R-(+)- Limonene, and Linalool. SPME was performed using an XYZ autosampler as shown in Figure 1. This enhanced method reproducibility and allowed for minimal hands-on time during sample preparation. The cannabis used for the study was provided courtesy of Dr. Hari H. Singh, program Director at the Chemistry & Physiological Systems Research Branch of the National Institute on Drug Abuse at the National Institute of Health. The strain of the cannabis sample was unknown, and HS-SPME analysis of this sample showed it to have much lower terpene content than what is typically reported for many strains sold for medical and recreational use [1]. Thus, in order to evaluate method accuracy in relevant concentration ranges, the sample had to be spiked with additional amounts of terpenes. Spiking was done by weight using a solution of terpenes in Hexane. Samples were allowed to equilibrate for 10 minutes after the spike was added and prior to proceeding with HS-SPME analysis. Quantitation of the spiked samples was done by external standard analysis, against a 5-point matrix matched calibration curve in cannabis.

RESULTS & DISCUSSION The results of analyses of the five point cannabis matrix-matched calibration curves for each terpene are shown in Figure 2. The unspiked cannabis was used as a zero point in each calibration. Linearity was good for all three terpenes across the indicated ranges. The high sensitivity of the HS-SPME method made it necessary to reduce the sample size to 100 mg and to open the splitter in the GC inlet during desorption. These measures were necessary to prevent overloading the GC/MS system. -Pinene Figure 1. MultiPurpose Sampler (MPS) in use during terpene analysis. Instrumentation. Analyses were performed on a 6890 GC equipped with a 5973N MSD (Agilent Technologies) and a MPS Sampler with SPME Option (GERSTEL), controlled by MAESTRO software, integrated with the Agilent software, using one method and one integrated sequence table for the complete system. Analysis conditions. MPS: SPME (PDMS fused silica) d f = 100 μm d o =24 ga Equilibration: 40 C (5 min), at 60 rpm Extraction: 40 C (10 min), at 250 rpm (headspace) Desorption: 270 C (3 min) Postbake: 270 C (5 min) S/SL: 270 C (isothermal) SPME liner, d i = 0.75 mm Pneumatics: constant flow Column: 60 m Equity-1 (Supelco), d i = 0.25 mm d f = 0.25 μm Oven: 60 C (2 min); 5 C/min; 140 C; 15 C/min; 250 C (0 min) MSD: full scan, 50-500 amu 300 C transfer line temp. Sample preparation. 0.1 g ground cannabis weighed into 20 ml clear glass, screw top vial with 8 ml deionized water added. Response (area counts) Response (area counts) Response (area counts) Conc. (mg/g) Linalool Conc. (mg/g) (+)-Limonene Conc. (mg/g) Figure 2. Head-space SPME extracted calibration curves of cannabis spiked with terpenes. - 2 -

An example of a chromatogram of a terpene-spiked cannabis sample is shown in Figure 3. For comparison, an unspiked sample of the same cannabis is shown in Figure 4. As indicated by the response scales on the Y-axis for the chromatograms, the terpenes targeted in the spiking study ( -Pinene, (R)-(+) Limonene and Linalool) were present in the unspiked cannabis, but at levels significantly lower than the spiked samples. In the lower scale chromatogram shown in Figure 4, heavier terpenes are also visible eluting towards the end of the run. Several of these were previously identified, and include Caryophyllene, Bergamotene, Farnesene, and other sesquiterpenes [2]. Table 1 shows a summary of method accuracy and reproducibility from analysis of spiked replicates. Accuracies for the targeted terpenes were > 90 % with RSD values of < 5 %. Abundance (R)-(+) Limonene 4.00E+06 2.00E+06 Hexane from spiking solution a-pinene Linalool Time--> 0 10 20 Figure 3. HS-SPME GC/MS analysis of cannabis spiked with terpenes: 3-7 mg/g. Abundance (R)-(+) Limonene 20000 10000 a-pinene Linalool Time--> 0 10 20 Figure 4. HS-SPME GC/MS analysis of unspiked cannabis, unknown variety. Compound Table 1. Results of analysis of spiked cannabis sample using HS-SPME method. Spike Conc. [mg/g] Avg. amount measured [mg/g] Accuracy [%] RSD (n=3) [%] α-pinene 1.08 1.11 103 0.9 (R)-(+)-Limonene 6.69 6.11 91 2.7 Linalool 3.72 3.62 97 3.0-3 -

CONCLUSIONS An HS-SPME method was developed which allows for an easy and accurate determination of terpene content in cannabis. The method was shown for three important terpenes found in cannabis: -Pinene, (R)-(+) Limonene and Linalool, however it could also be used for other terpenes as well. The method does not require organic solvents, and with the use of an autosampler, is highly reproducible and requires little hands-on sample preparation time. In addition, due to the high sensitivity of the SPME technique, very little sample is required. Using headspace produces a very clean chromatographic analysis with little to no background from co-extracted matrix, which in turn will maintain the cleanliness of the GC system. Using GC/MS offers the added benefit of spectral confirmation of peaks to ensure that identification is accurate with no co-eluting interferences. REFERENCES [1] Williams, K. Cannabinoids and Terpenoids: The Future of Cannabis Connoisseurship. 2/21/2014, www.leafly.com/news/tags/connoisseur (accessed June 2016) [2] Stenerson, K.K. Headspace SPME-GC/MS Analysis of Terpenes in Hops and Cannabis; MilliporeSigma Reporter 34.4: 3-6. ACKNOWLEDGEMENTS The authors would like to thank Bob Shirey and Yong Chen of MilliporeSigma for their many helpful discussions on SPME. - 4 -

- 5 - GERSTEL Application Note No. 189, 2017

GERSTEL GmbH & Co. KG Eberhard-Gerstel-Platz 1 45473 Mülheim an der Ruhr Germany +49 (0) 208-7 65 03-0 +49 (0) 208-7 65 03 33 gerstel@gerstel.com www.gerstel.com GERSTEL Worldwide GERSTEL, Inc. 701 Digital Drive, Suite J Linthicum, MD 21090 USA +1 (410) 247 5885 +1 (410) 247 5887 sales@gerstelus.com www.gerstelus.com GERSTEL AG Wassergrabe 27 CH-6210 Sursee Switzerland +41 (41) 9 21 97 23 gerstelag@ch.gerstel.com www.gerstel.ch GERSTEL K.K. 1-3-1 Nakane, Meguro-ku Tokyo 152-0031 SMBC Toritsudai Ekimae Bldg 4F Japan +81 3 5731 5321 +81 3 5731 5322 info@gerstel.co.jp www.gerstel.co.jp GERSTEL LLP Level 25, North Tower One Raffles Quay Singapore 048583 +65 6622 5486 +65 6622 5999 SEA@gerstel.com www.gerstel.com GERSTEL Brasil Av. Pascoal da Rocha Falcão, 367 04785-000 São Paulo - SP Brasil +55 (11)5665-8931 +55 (11)5666-9084 gerstel-brasil@gerstel.com www.gerstel.com.br Information, descriptions and specifications in this Publication are subject to change without notice. GERSTEL, GRAPHPACK and TWISTER are registered trademarks of GERSTEL GmbH & Co. KG. Copyright by GERSTEL GmbH & Co. KG Awarded for the active pursuit of environmental sustainability