Acta Cardiol Sin 2018;34: doi: /ACS _34(2) A

Similar documents
OCT in the Evaluation of Vascular Healing Following DES Implantation: Will It Be a Helpful Tool to Reduce Stent Thrombosis?

JACC: CARDIOVASCULAR INTERVENTIONS VOL. 2, NO. 5, PUBLISHED BY ELSEVIER INC. DOI: /j.jcin

OCT Findings: Lesson from Stable vs Unstable Plaques

Usefulness of OCT during coronary intervention

Culprit Lesion Remodeling and Long-term (> 5years) Prognosis in Patients with Acute Coronary Syndrome

HCS Working Group Seminars Macedonia Pallas Hotel, Friday 21 st February Drug-eluting stents Are they all equal?

Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents

CLINICAL APPLICATIONS OF OPTICAL COHERENCE TOMOGRAPHY. Konstantina P. Bouki, FESC 2 nd Department of Cardiology General Hospital Of Nikea, Pireaus

Catch-up Phenomenon: Insights from Pathology

Abstract Background: Methods: Results: Conclusions:

SMJ Singapore Medical Journal

INTRODUCTION. Catheterization and Cardiovascular Interventions 82:E871 E878 (2013)

2010 Korean Society of Cardiology Spring Scientific Session Korea Japan Joint Symposium. Seoul National University Hospital Cardiovascular Center

Drug Eluting Stents Sometimes Fail ESC Stockholm 29 Set 2010 Stent Thrombosis Alaide Chieffo

Optical coherence tomography patterns of in-stent restenosis: Comparison between bare-metal stent and drug-eluting stent

Bifurcation Stenting: IVUS and OCT Information

Evaluation of stent placement and outcomes with optical coherence tomography

Optical Coherence Tomography for Intracoronary Imaging

Αγγειοπλαστική σε Eπαναστενωτικές Bλάβες

Assessment of plaque morphology by OCT in patients with ACS

malapposition assessed by OCT

Analysis of neointimal coverage after silolimus-eluting stent implantation using optical coherence tomography.

Drug eluting stents (DES) have decreased

Sirolimus-Eluting Stents for Treatment of In-Stent Restenosis

Very late thrombosis of sirolimus-eluting stent due to late malapposition: Serial observations with optical coherence tomography

eluting Stents The SPIRIT Trials

Results of TROFI II Study. Patrick W. Serruys, MD, PhD. Imperial college, London, UK On behalf of the PI s and the TROFI II investigators

Post PCI functional testing and imaging: case based lessons from FFR React

Results of TROFI II Study. Patrick W. Serruys, MD, PhD. Imperial college, London, UK On behalf of the PI s and the TROFI II investigators

Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial

Clinical Value of OCT. Guidance for Coronary Stenting. Giulio Guagliumi, MD

A Novel Low Pressure Self Expanding Nitinol Coronary Stent (vprotect): Device Design and FIH Experience

OCT Technology: Differences between Biodegradable and Durable Polymers: Insights from the LEADERS Trial LEADERS OCT

Clinical Application of OCT in Stent Evaluation

Vessel healings after stenting with different polymers in STEMI patients

Stent strut coverage of titanium-nitride-oxide coated stent compared to paclitaxel-eluting stent in acute myocardial infarction: TITAX-OCT study

Neointimal coverage of bare-metal and sirolimuseluting stents evaluated with optical coherence tomography

Comparison of Optical Coherence Tomographic Assessment between First- and Second-Generation Drug-Eluting Stents

Drug eluting stents From revolution to evolution. Current limitations

Declaration of conflict of interest. Nothing to disclose

BIOFREEDOM: Polymer free Biolimus A9 eluting

INDEX 1 INTRODUCTION DEVICE DESCRIPTION CLINICAL PROGRAM FIRST-IN-MAN CLINICAL INVESTIGATION OF THE AMAZONIA SIR STENT...

2yrs 2-6yrs >6yrs BMS 0% 22% 42% DES 29% 41% Nakazawa et al. J Am Coll Cardiol 2011;57:

IN-STENT RESTENOSIS. K.Boerlage-van Dijk CarVasZ 2014

OCT; Comparative Imaging Results with IVUS, VH and Angioscopy

European Heart Journal - Cardiovascular Imaging Advance Access published January 4, 2013

The BIO revolution: bioadsorbable stents. Federico Conrotto Cardiologia 2 Città della Salute e della Scienza di Torino

DEB experience in Gachon Universtiy Gil Hospital (in ISR) Soon Yong Suh MD., PhD. Heart Center Gachon University Gil Hospital Seoul, Korea.

TLR des Stents Actifs

Conflict of interest :None. Meta-analysis. Zhangwei Chen, MD

In the field of interventional cardiology, drug-eluting stent

DID OCT change our experience on coronary arteries?

Insights in Thrombosis and In-Stent Restenosis

Resolute in Bifurcation Lesions: Data from the RESOLUTE Clinical Program

Komplexe Koronarintervention heute: Von Syntax zu bioresorbierbaren Stents

LCX. President / Director of Cardiology / New Tokyo Hospital

PROMUS Element Experience In AMC

Journal of the American College of Cardiology Vol. 47, No. 7, by the American College of Cardiology Foundation ISSN /06/$32.

Shedding light on stent thrombosis

STENTYS for Le, Main Sten2ng. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

Analysis of macrophage accumulation using optical coherence tomography one year after sirolimus, paclitaxel and zotarolimus-eluting stent

Medicine OBSERVATIONAL STUDY

LM stenting - Cypher

Bioresorbable polymer drug-eluting stents in PCI

Coronary Stent Choice in Patients With Diabetes Mellitus

OCT Analysis in Patients With Very Late Stent Thrombosis

Biodegradable Stents An update and work-in

Unprotected Left Main Coronary Artery Disease in Patients With Low Predictive Risk of Mortality

Added Value of Invasive Coronary Imaging for Plaque Rupture and Erosion

Clinical Investigations

Complex PCI. Your partner in complex PCI: In-stent restenosis (ISR)

Ruofei Jia, Zening Jin, Hong Li, Jing Han. Introduction

Next Generation Drug- eluting Stent : Will It Solve the Problem?

Pathology of percutaneous interventions (PCI) in coronary arteries. Allard van der Wal, MD.PhD; Pathologie AMC, Amsterdam, NL

Supplementary Material to Mayer et al. A comparative cohort study on personalised

Journal of the American College of Cardiology Vol. 46, No. 5, by the American College of Cardiology Foundation ISSN /05/$30.

INSIDE INFORMATION YOU CAN T IGNORE

Bioabsorbable stents: early clinical results. Dr Angela Hoye MB ChB, PhD Senior Lecturer in Cardiology Hull & East Yorkshire Hospitals

Technical considerations in the Treatment of Left Main Lesions Ioannis Iakovou, MD, PhD

PCI for Left Anterior Descending Artery Ostial Stenosis

Incidence and Predictors of Stent Thrombosis after Percutaneous Coronary Intervention in Acute Myocardial Infarction

Review Article Optical Coherence Tomography Imaging in Acute Coronary Syndromes

A Case of Recoiling of Everolimus - eluting Stent at the Ostium of the Right Coronary Artery by Out - stent Plaque Progression

For Personal Use. Copyright HMP 2013

Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis

Left main coronary artery (LMCA): The proximal segment

Le# main treatment with Stentys stent. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

Stents selection and optimal implantation: sizes, design, deployment Abbott Vascular. All rights reserved.

Although drug-eluting stents (DESs) have radically

Clinical Study Age Differences in Long Term Outcomes of Coronary Patients Treated with Drug Eluting Stents at a Tertiary Medical Center

Perspective of LM stenting with Current registry and Randomized Clinical Data

Research Article Pathological Perspective of Drug-Eluting Stent Thrombosis

For Personal Use. Copyright HMP 2014

Comparison of Sirolimus Versus Paclitaxel Eluting Stents for Treatment of Coronary in-stent Restenosis F. Airoldi, et al. Am J Cardiol (2006)

Rationale for Percutaneous Revascularization ESC 2011

What is the Optimal Triple Anti-platelet Therapy Duration in Patients with Acute Myocardial Infarction Undergoing Drug-eluting Stents Implantation?

Appearance of Lipid-Laden Intima and Neovascularization After Implantation of Bare-Metal Stents

Impact of Coronary Plaque Characteristics on Late Stent Malapposition after Drug-Eluting Stent Implantation

Prevention of Coronary Stent Thrombosis and Restenosis

Transcription:

Original Article Acta Cardiol Sin 2018;34:124 129 doi: 10.6515/ACS.201803_34(2).20171115A Coronary Artery Disease Vascular Healing Response after Everolimus-Eluting Stent Implantation in Acute Coronary Syndrome Culprit Lesions: Comparison with Implantation in Stable Angina Pectoris Yutaka Goryo, 1 Teruyoshi Kume, 1 Tomoya Ueda, 2 Makoto Watanabe, 2 Ryotaro Yamada, 1 Yoji Neishi, 1 Yoshihiko Saito 2 and Shiro Uemura 1 Background: To evaluate the neointimal conditions of everolimus-eluting stents (EESs) implanted in culprit lesions of patients with acute coronary syndrome (ACS) compared with stable angina pectoris (SAP) using optical coherence tomography (OCT). EESs are second-generation drug-eluting stents that have recently been shown to be useful in patients with ACS as well as in patients with SAP. However, few studies have analyzed the intra-stent conditions of EESs that can lead to favorable results in such ACS lesions. Methods: We evaluated 41 ACS patients with EES implantation (age, 66.7 10.3 years) and 59 SAP patients enrolled as controls (age, 68.3 10.7 years). OCT examinations were performed after 9 months of follow-up after stent implantation, and the condition of the neointimal coverage over every stent strut was assessed in 1-mm intervals. In addition, neointimal thickness (NIT) over each strut was measured and tissue characteristics were examined. Results: There was no significant difference in mean NIT between the ACS (90.8 ± 88.2 mm) and SAP (87.3 ± 74.2 mm, p = 0.11) group. The rate of uncovered struts was significantly lower in the ACS group (11.5%) than in the SAP group (12.5%, p = 0.03). Neointimal tissue characteristics were also similar between groups. Conclusions: Vascular responses after EES implantation differed significantly between ACS and SAP lesions using OCT. However, these differences were considered small in clinical terms. Our OCT data support the favorable results of patients with EES implantation at mid-term follow-up, even in those with ACS. Key Words: Acute coronary syndrome Drug-eluting stent Everolimus-eluting stent Optical coherence tomography Percutaneous coronary intervention INTRODUCTION Stent implantation has been used to treat coronary artery stenosis for several decades. Treatment with bare Received: June 23, 2017 Accepted: November 15, 2017 1 Department of Cardiology, Kawasaki Medical School, Kurashiki; 2 First Department of Internal Medicine, Nara Medical University, Kashihara, Japan. Corresponding author: Dr. Yutaka Goryo, Department of Cardiology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama 701-0192, Japan. Tel: +81-86-462-1111; Fax: +81-86-462-1199; E-mail: yutaka_goryo@yahoo.co.jp metal stents (BMSs) can successfully restore the acute vessel lumen, but long-term outcomes are often compromised by in-stent restenosis (ISR). The first generation of drug-eluting stents (DESs) markedly reduced ISR compared with BMSs, however patients with acute coronary syndrome (ACS) have been shown to have a greater risk of thrombotic complications after first-generation DES implantation compared to those with stable angina pectoris (SAP). 1,2 A recent clinical trial suggested the superiority of everolimus-eluting stents (EESs), a so-called second-generation DES, over BMSs even in patients with ACS. 3 Treating ACS with second-generation Acta Cardiol Sin 2018;34:124 129 124

Vascular Healing Response to EES in ACS and SAP DESs is now the established and preferred therapeutic option. Although recent clinical trials have reported that implanted EESs show improved efficacy and safety compared with BMSs, few studies have analyzed the intrastent conditions of EESs that could lead to favorable results in such ACS lesions. Therefore, the aim of this study was to compare vascular responses in lesions treated with EES implantation using optical coherence tomography (OCT), which is the gold standard for assessing intrastent conditions between ACS and SAP lesions. METHODS Study population Consecutive patients who underwent percutaneous coronary interventions (PCIs) with EESs (Xience TM ;Abbott Vascular, Santa Clara, CA) for de novo lesions at Nara Medical University Hospital from October 2010 to February 2014 were enrolled. Patients with ACS and SAP were retrospectively analyzed and compared in this study. The interventional strategy and stent selection were left to the discretion of the operator. All patients received 100 mg of aspirin with either 75 mg of clopidogrel or 200 mg of ticlopidine after the PCI. Follow-up (9 months) coronary angiography is routinely performed in our institution. Dual antiplatelet therapy was generally continued until follow-up coronary angiography. All of the enrolled patients received OCT examinations (ILUMIEN or ILUMIEN OPTIS OCT Intravascular Imaging System; St. Jude Medical, St. Paul, MN) during follow-up coronary angiography. We excluded patients with ISR or unclear OCT images due to insufficient blood removal at the 9-month follow-up coronary angiography (Figure 1). This study was complied with the Declaration of Helsinki with regard to investigations in humans. The study protocol was approved by the Ethics Committee of Nara Medical University, and written informed consent was obtained from each patient prior to enrolment. OCT imaging and analysis OCT was performed during follow-up angiography after the administration of intracoronary nitroglycerin (0.2 mg). An OCT catheter was placed distal (> 10 mm) to the stented lesion and pulled back using an automatic pull back system. Cross-sectional OCT images of the stented segments at 1-mm intervals were analyzed. We evaluated the apposition and neointimal coverage of each stent strut and neointimal characteristics. Incomplete stent apposition was defined as a strut detached by more than 108 m from the inner vessel wall. This definition was made based on the resolution limit of OCT (20 m)andbothstrutthickness(81 m) and polymer thickness of the EES (7 m). 4,5 Acoveredstrut was defined as a neointimal thickness (NIT), defined as thedistancebetweenthecenterofthestrutandthe neointimal surface, of > 30 m (Figure 2). 6 We classified the neointimal tissue characteristics into three patterns: homogeneous, heterogeneous, and layered (Figure 3). 7 Thrombus was defined as a mass protruding into the lumenwithanirregularsurface. 8 The OCT findings were then compared between the ACS and SAP groups. Statistical analysis Continuous variables are presented as mean standarddeviationormedian(25th,75thpercentiles),and were compared using the Student s t-test. Categorical variables are expressed as percentages and were compared using the chi-square test. A p value of < 0.05 were considered to be statistically significant. All statistical analyses were conducted using JMP for Mac version 11.0 (SAS Institute, Cary, NC). RESULTS A total of 100 patients (100 lesions) including 41 with ACS [acute myocardial infarction (AMI), n = 34; un- Figure 1. Patient flow chart. ACS, acute coronary syndrome; CoCr, cobalt chrome; f/u, follow-up; IVUS, intravascular ultrasound; M, months; OCT, optical coherence tomography; pts, patients; SAP, stable angina pectoris; TLR, target lesion revascularization. 125 Acta Cardiol Sin 2018;34:124 129

Yutaka Goryo et al. A B Figure 2. Stent strut condition by optical coherence tomography images. (A) Malapposed strut without coverage. (B) Covered struts and neointimal thickness (NIT). (C) Well-apposed struts to the vessel wall without coverage. stable angina pectoris, n = 7] and 59 with SAP were studied. The baseline clinical characteristics are shown in Table 1. In terms of risk factors, past smokers were more frequent in the ACS group than in the SAP group. The baseline medications are shown in Table 2. Calcium channel blockers were preferentially used for hypertension in the SAP group, and the ACS group more frequently received -blockers and angiotensin-converting enzyme inhibitors (ACE-Is) than the SAP group. At the 9-month follow-up visit, dual antiplatelet therapy was interrupted for non-cardiac surgery in one patient with ACS (2.50%) and four with SAP (6.06%, p = 0.35). The procedural characteristics are listed in Table 3. The target vessel, selected stent size and balloon diameter used C A B C Figure 3. Neointimal tissue characteristics on optical coherence tomography. (A) Homogeneous pattern. (B) Heterogeneous pattern. (C) Layered pattern. Table 2. Baseline medications Aspirin, n (%) 41 (100) 56 (94.9) 0.14 Clopidogrel, n (%) 40 (97.6) 57 (96.6) 0.78 Ticlopidine, n (%) 0 (0)0. 01 (1.69) 0.40 Warfarin, n (%) 0 (0) 0 0(0)0 1.00 Cilostazol, n (%) 01 (2.44) 04 (6.78) 0.33 EPA, n (%) 02 (4.88) 02 (3.39) 0.71 Statin, n (%) 38 (92.7) 51 (86.4) 0.33 Nicorandil, n (%) 07 (17.1) 08 (13.6) 0.63 Isosorbide, n (%) 0 (0) 0 01 (1.69) 0.40 Nytroglycerin, n (%) 01 (2.44) 03 (5.08) 0.51 CCB, n (%) 08 (19.5) 26 (44.1) 0.01 blocker, n (%) 27 (65.9) 21 (35.6) < 0.01 < ACE-I, n (%) 25 (61.0) 13 (22.0) < 0.01 < ARB, n (%) 16 (39.2) 27 (45.8) 0.50 Insulin, n (%) 2 (4.88) 05 (8.47) 0.49 ACE-I, angiotensin converting enzyme inhibitor; ACS, acute coronary syndrome; ARB, angiotensin II receptor blocker; CCB, calcium channel blocker; EPA, eicosapentaenoic acid; SAP, stable angina pectoris. Values are numbers (%) of patients. Table 1. Baseline clinical characteristics No. of patients 41 (AMI 34 UAP 7) 59 Male gender, n (%) M 34 (82.9), F 7 M 45 (76.3), F 14 0.42 Age, years old 66.7 10.3 68.3 10.7 0.43 Follow up, days.304 68.7.284 63.2 0.07 Risk factor Hypertension, n (%) 27 (65.9) 45 (76.3) 0.25 Dyslipidemia, n (%) 38 (92.7) 51 (86.4) 0.33 Diabetes mellitus, n (%) 16 (39.0) 20 (33.9) 0.60 Current smoker, n (%) 03 (7.32) 06 (10.2) 0.62 Past smoker, n (%) 29 (70.7) 27 (45.8) 0.01 BMI, kg/m 2 23.5 3.82 24.3 4.00 0.22 Family history, n (%) 14 (34.2) 17 (28.8) 0.57 Previous cardiac surgery 0 0 1.00 Hemodyalysis, n (%) 03 (7.50) 05 (8.47) 0.86 ACS, acute coronary syndrome; BMI, body mass index; ISR, in-stent restenosis; SAP, stable angina pectoris. Values are expressed as mean standard deviation (SD) or n (%). Acta Cardiol Sin 2018;34:124 129 126

Vascular Healing Response to EES in ACS and SAP for post-dilatation were similar between groups. OCT examinations at follow-up A total of 2540 OCT cross-sections and 20622 stent struts were analyzed. The OCT findings are shown in Table 4. The minimum lumen area and mean NIT at 9 months of follow-up were similar between the ACS and SAP groups. Most stent struts were well-apposed to the vessel wall in both groups. However, uncovered stent struts were observed significantly less frequently in the ACS group than in the SAP group. No evidence of thrombus was detected in either group. With regards to neointimal tissue characteristics, no significant differences were noted between the groups, with a homogeneous patterninmorethan98%ineach. DISCUSSION The main findings of this study areas follows: 1) the mean NIT of EESs implanted in the culprit lesions of the ACS group were not significantly different compared with the SAP group; 2) the rate of uncovered struts was significantly lower in the ACS group than in the SAP group at 9 months of follow-up; and 3) the neointimal tissue characteristics were similar between the groups. These results are similar to previous studies of vessel reactions to EESs. 4,9,10 ThemeanNITandappositionofthestent Table 3. Procedural characteristics No.oftargetlesion,n(%) 0.15 LAD 28(68.3) 34(57.6) LCX 1 (2.44) 08 (13.6) RCA 12(29.3) 17(28.8) No. of stent, n 46 67 Stent diameter, mm 2.85 0.33 2.87 0.41 0.96 Stent length, mm 22.9 7.25 23.9 8.83 0.77 Post dilatation, n (%) 38 (92.7) 53 (89.8) 0.62 Balloon diameter for post dilatation, mm 2.98 0.33 3.10 0.50 0.23 ACS, acute coronary syndrome; LAD, left anterior descending artery; LCX, left circumflex artery; RCA, right coronary artery; SAP, stable angina pectoris. Values are expressed as mean standard deviation (SD) or n (%). Table 4. OCT findings at follow-up angiography Cross-sections, n 1000 1540 Total struts, n 8023 12599 MLA in stented segment, mm 2 5.66 1.63 5.50 2.06 0.36 Neointimal area at MLA site, mm 2 1.30 1.14 1.07 0.81 0.47 Median NIT, m 70 (IQR; 40-120) 60 (IQR; 40-120) 0.11 Average NIT, m 90.8 88.2 87.3 74.2 0.11 Presence of thrombi, n (%) 0 0 1.00 Uncovered struts, n (%) 922 (11.5) 1574 (12.5) 0.03 Well-apposed struts, n (%) 7981 (99.5)0 12541 (99.5)0 0.52 Neointimal characteristics Homogeneous pattern, n (%) 983 (98.3) 1525 (99.0) 0.11 Heterogeneous pattern, n (%) 004 (0.40) 0004 (0.26) 0.54 Layered pattern, n (%) 13 (1.3) 0011 (0.71) 0.14 ACS, acute coronary syndrome; MLA, minimum lumen area; NIT, neointimal thickness; SAP,stable angina pectoris. Neointimal area defined as stent area lumen area. Values are expressed as mean standard deviation (SD) or n (%). 127 Acta Cardiol Sin 2018;34:124 129

Yutaka Goryo et al. struts in these previous studies ranged from 100 to 119 m for NIT and 97.3% to 99.9% for apposition of stent struts. With first-generation sirolimus-eluting stents, previous OCT studies have shown that the incidence of incomplete stent apposition and inadequate coverage were significantly greater in ACS lesions than in SAP lesions at mid-term follow-up, and that this deficient stent condition remained at long-term follow-up. 11,12 In ACS patients, culprit lesions often showed plaque rupture and a proportion of ruptured cavities persisted even at follow-up. Stent struts implanted at such ruptured sites demonstrated persistent or late acquired incomplete stent apposition at follow-up. These findings represent risk factors for late or very late stent thrombosis 13,14 and could explain why first-generation DES implantation is more frequently associated with clinical events during follow-up in ACS patients than in SAP patients. In contrast to first-generation DESs, a previous OCT study and the present results showed that second-generation EES implants promoted a favorable arterial healing response in terms of stent strut apposition and coverage, even in patients with ACS. 9 These OCT data may support better clinical outcomes of EESs in ACS patients than in SAP patients. The frequency of uncovered struts was significantly lower in the ACS lesions than in the SAP lesions in the present study. The culprit lesions in the patients with ACS showed local but stronger inflammation within vulnerable plaques compared to those in the patients with SAP. 15 In a previous intravascular ultrasound (IVUS) study in the BMS era, systemic inflammation conditions such as diabetes mellitus were reported to possibly increase neointimal hyperplasia. 16 We therefore speculate that the enhanced inflammation in ACS lesions may have stimulated neointimal proliferation, leading to a low rate of uncovered struts after EES implantation compared with SAP lesions. In the DES era, late or very late stent thrombosis is a rare but fatal event. Some studies have reported that incomplete stent strut coverage is a morphologic risk factor for stent thrombosis. 17-19 The lower rate of uncovered struts in the ACS patients with EES implantation in the present study implies that the use of EESs for patients with ACS may prevent stent thrombosis. With regards to qualitative OCT analysis, we analyzed the neointimal characteristics using OCT, and more than 98% of the cases with neointimal hyperplasia showed a homogeneous pattern comprising smooth muscle cells with rich collagen and elastin, even in the patients with ACS. 20 Furthermore, no evidence of thrombus detected by OCT was seen in our study. Considering previous OCT results and our favorable results, EESs with low-dose everolimus (100 g/cm 2 ) and a fluoropolymer with antithrombotic effects may provide an excellent vascular healing profile, even when the EES is implanted in ACS culprit lesions. 21 Fukuhara et al. reported that neointimal characteristics detected by OCT after DES implantation maybe related to late neointimal progression or regression, and that neointima with a homogeneous pattern was the only predictor of late neointimal regression during mid-term follow-up. 20 The relationship between neointimal characteristics and long-term neointimal behavior including atherosclerotic changes within neointima (neoatherosclerosis) remains unclear. Patients treated with EESs should thus receive long-term followup, irrespective of whether they have ACS or SAP. Several limitations must be considered when interpreting the present study. First, this study was a singlecenter, retrospective, observational study. There was no randomization. In addition, the sample size was relatively limited, raising the possibility of selection bias. These limitations mean that we cannot make definitive conclusions. Second, we analyzed the strut condition without considering within-lesion correlation matrix, which may have led to lesion bias. Third, we did not evaluate patients with ISR and other types of stents. Finally, the follow-up period was limited to 9 months. Therefore we could not assess the correlations between the OCT findings and clinical outcomes such as stent thrombosis andlatecatch-upisr.studieswithlong-termfollow-up and a larger population are needed to confirm our results. CONCLUSIONS Vascular response after EES implantation differed significantly between ACS and SAP lesions using OCT. However, these differences were considered small in terms of clinical relevance. Our OCT data support the favorable results of patients with EES implantation at midterm follow-up, even in ACS patients. However, careful long-term follow-up is warranted. Acta Cardiol Sin 2018;34:124 129 128

Vascular Healing Response to EES in ACS and SAP DECLARATION OF CONFLICT OF INTEREST All the authors declare no conflict of interest. REFERENCES 1. Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773-80. 2. Urban P, Gershlick AH, Guagliumi G, et al. Safety of coronary sirolimus-eluting stents in daily clinical practice: one-year follow-up of the e-cypher registry. Circulation 2006;113:1434-41. 3. Palmerini T, Biondi-Zoccai G, Della Riva D, et al. Clinical outcomes with drug-eluting and bare-metal stents in patients with ST-segment elevation myocardial infarction: evidence from a comprehensive network meta-analysis. J Am Coll Cardiol 2013;62:496-504. 4. Inoue T, Shite J, Yoon J, et al. Optical coherence evaluation of everolimus-eluting stents 8 months after implantation. Heart 2011;97:1379-84. 5. Tanigawa J, Barlis P, Di Mario C. Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. EuroIntervention 2007;3: 128-36. 6. Sawada T, Shite J, Negi N, et al. Factors that influence measurements and accurate evaluation of stent apposition by optical coherence tomography. Assessment using a phantom model. Circ J 2009;73:1841-7. 7. Gonzalo N, Serruys PW, Okamura T, et al. Optical coherence tomography patterns of stent restenosis. Am Heart J 2009;158: 284-93. 8. Kume T, Akasaka T, Kawamoto T, et al. Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 2006;97:1713-7. 9.MizoguchiT,SawadaT,ShinkeT,etal.Detailedcomparisonof intra-stent conditions 12 months after implantation of everolimus-eluting stents in patients with ST-segment elevation myocardial infarction or stable angina pectoris. Int J Cardiol 2014; 171:224-30. 10. Choi HH, Kim JS, Yoon DH, et al. Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography. Int J Cardiovasc Imaging 2012;28:491-7. 11.HassanAK,BergheanuSC,StijnenT,etal.Latestentmalapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J 2010;31:1172-80. 12. Kubo T, Imanishi T, Kitabata H, et al. Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris a serial optical coherence tomography study. JACC: Cardiovascular Imaging 2008;1:475-84. 13. Cook S, Wenaweser P, Togni M, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 2007;115:2426-34. 14. Ishigami K, Uemura S, Morikawa Y, et al. Long-term follow-up of neointimal coverage of sirolimus-eluting stents--evaluation with optical coherence tomography. Circ J 2009;73:2300-7. 15. Hansson GK, Libby P, Tabas I. Inflammation and plaque vulnerability. J Intern Med 2015;278:483-93. 16. Kornowski R, Mintz GS, Kent KM, et al. Increased restenosis in diabetes mellitus after coronary interventions is due to exaggerated intimal hyperplasia. A serial intravascular ultrasound study. Circulation 1997;95:1366-9. 17. Jimenez-Valero S, Moreno R, Sanchez-Recalde A. Very late drugeluting stent thrombosis related to incomplete stent endothelialization: in-vivo demonstration by optical coherence tomography. J Invasive Cardiol 2009;21:488-90. 18. Wenaweser P, Daemen J, Zwahlen M, et al. Incidence and correlates of drug-eluting stent thrombosis in routine clinical practice. 4-year results from a large 2-institutional cohort study. J Am Coll Cardiol 2008;52:1134-40. 19. Finn AV, Joner M, Nakazawa G, et al. Pathological correlates of late drug-eluting stent thrombosis strut coverage as a marker of endothelialization. Circulation 2007;115:2435-41. 20. Fukuhara K, Okura H, Kume T, et al. In-stent neointimal characteristics and late neointimal response after drug-eluting stent implantation: a preliminary observation. J Cardiol 2016;67:437-41. 21. Kolandaivelu K, Swaminathan R, Gibson WJ, et al. Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings. Circulation 2011;123:1400-9. 129 Acta Cardiol Sin 2018;34:124 129