StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

Similar documents
Progeny Hip Stem. Surgical Protocol and Product Specifications

Surgical Technique and Product Specifications

ACETABULAR CUP SURGICAL TECHNIQUE

Surgical Technique. Cup System

Manza Cup HA SURGICAL TECHNIQUE.

Dual Mobility System Evaluation surgical technique

Dual Mobility System Surgical technique

FMP Surgical Technique

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Duraloc CONSTRAINED LINER

CONSENSUS ORTHOPEDICS INC.

Trilogy Acetabular System

Trilogy Acetabular System

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

OPTIONAL/ADDITIONAL INSTRUMENTS

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

Ceramic Femoral Heads and Acetabular Cup Liners

pact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation

Trilogy Acetabular System

Operative Technique Crown Cup Acetabular System

Rx90 Total Hip System Acetabular Series

Trinity. Advanced Bearing Acetabular System Surgical technique

Cementless Tapered Femoral Stem Surgical technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

System Surgical Protocol

Cementless Tapered Femoral Stem Surgical technique

CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM

Optimum implant geometry

CMA TM Cemented Modular Augmentable. Baseplate. 2 Knee

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

U2 PSA. Revision Knee. Surgical Protocol

Restoration Anatomic Acetabular System Surgical Technique

BIOLOX delta Option Ceramic Femoral Head System

Technique Guide Small Bone Fusion System

Revision. Hip Stem. Surgical Protocol

Zimmer Maxera Cup. Surgical Technique. This device is not available for commercial distribution in the United States.

ADM X3 Mobile Bearing Hip. System Surgical Protocol. Available with X3 Advanced Bearing Technology. For Use With Restoration ADM Cups and Inserts

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

BIOLOX delta Option Ceramic Femoral Head System. Product Features and Instructions for Use

Longevity Offset and Oblique Liners. Surgical Technique

Exeter X3 RimFit Acetabular Cup

PROCOTYL E Acetabular Cup System. Modular to Fit Patient s Anatomy. Versatile for Revisions.

Constrained Acetabular Insert

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

*smith&nephew CONTOUR

SURGICAL TECHNIQUE IMPROVED WEAR REDUCTION PROVEN FIXATION PRECISE INSTRUMENTATION RELIABILITY

Positioning Sleeve Surgical Technique

BiMobile Dual Mobility System Cementless & Cemented. Surgical Technique

Bi-Polar 22.2mm & 28mm System - Operative technique

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

CONSENSUS ORTHOPEDICS INC. CONSENSUS KNEE SYSTEM

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

RECOVERY. P r o t r u s i o

AVANTEON. Operative Technique & Catalogue Information AVANTEON

Optimizing function Maximizing survivorship Accelerating recovery

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

TriboFit Hip System. Issue 3 - August 2013 English

Precautionary Statement ( )

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

Active Articulation. Surgical Technique. Dual Mobility Hip System. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

Taperloc Complete Hip System. Surgical Technique

Surgical Technique. Poly and Ceramic

Integral 180 Surgical Technique

Trident All Poly Acetabular System

WristMotion Wrist Hemiarthroplasty System Instructions for Use

Zimmer MMC Cup. Surgical Technique. Large Diameter Metal-on-Metal

A novel cementless option. Zimmer NexGen Trabecular Metal Primary Patella Surgical Technique

Description Materials Indications Patient selection factors to be considered include: Contraindications Absolute contraindications include:

Signature Personalized Patient Care

Hip Resurfacing System

operative technique Kent Hip

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

TaperFit. Cemented Total Hip Replacement Surgical technique

The Leader in Orthopaedic Innovation

Bone Bangalore

SURGICAL TECHNIQUE GUIDE

UTF Stem. reduced. Surgical Protocol

HIP SYSTEM SURGICAL TECHNIQUE

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

UNDERSTANDING TRADITION, MASTERING INNOVATION. Surgical Technique

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

Trabecular Metal Primary Patella

MITCH TRH System Modular Head Operative Technique

Scan Bi-Polar 22/28. Operative Technique

Hip Product Brochure

Clinical Evaluation Surgical Technique

Technique Guide KISSloc Suture System

PMMA Spacer. X-ray Marker

Trident Constrained Acetabular Insert Surgical Protocol

Transcription:

StelKast Acetabular Surgical Protocol and Product Specifications Including ProForm, Provident, Provident Apical Threaded Hole & Systems

StelKast Acetabular Surgical Protocol Introduction StelKast offers a variety of acetabular options to meet the needs of today s orthopedic surgeons. The modular acetabular system consists of a Titanium shell and a polyethylene liner. The outside of the shell is hemispherical with a rim flare at the circumference and is textured with either porous beads or plasma spray. No hole, cluster hole or multiple hole configurations are available. Each shell includes a permanently assembled retaining ring to firmly hold the polyethylene liner, while allowing for easy removal of the liner if required. Acetabular Preparation Figure 1 Preparation of Acetabulum with Reamers Once the acetabular labrum and redundant capsule are removed, the floor of the cotyloid fossa is identified. Commonly this is crowded with osteophytes which are removed with a large curette. This portion of the nonarticular floor of the acetabulum clearly delineates the extent of the medial wall inferiorly. Reaming confluent with this level will medialize the component without perforation of the medial wall. Reaming is begun approximately 6-8 mm less than the templated size. The initial reaming is done and the reamer orbited to remove the cartilaginous debris. Sequential reaming is done in 1-2 mm increments with attention to the thickness of the acetabular walls (Figure 1). When thinning is present, the reamer should be pulled toward the opposite wall to avoid the generation of a rim defect. In addition with increasing reamer diameter the position of the reamer should mimic the final position of the acetabular component. The finished acetabulum should have the cotyloid fossa removed and the acetabular rim snug against the finishing reamer. The tightness of the fit can be trialed with the acetabular trials. The trial equal in diameter to the last acetabular reamer should be used. This will provide line to line fit with the trial shell. An implant equal to the reamer size will provide a line to line fit in the hemisphere region and a 1.25 mm total interference rim fit. It is recommended that the spherical difference between the reamer and shell not exceed 1 mm due to the flared rim of the acetabular shell. 2

Acetabular Component Insertion Insertion of the Acetabular Shell The acetabular components can be used with or without screws. This can be accomplished by selecting a shell size equal to the reamer diameter or by using a shell that is 1 mm larger than the reamer diameter for a tighter fit. Note that shell sizes are available in even numbers with 2 mm increments. NOTE: If a 36mm femoral head is desired: The ProForm and Provident Shells and Liners offer this option starting with a 54mm Shell. The Cross-Over Shell and Liners offer this option with a 52mm Shell. ProForm and Provident Shells and Liners are not compatible with the Cross-Over Shell and Liners. Figure 2 Attachment of Acetabular Inserter to Shell All Acetabular Shells have a groove that accepts an expanding end inserter. The Provident Apical Threaded Hole Shell is offered with both this groove and a threaded hole for insertion. Expanding End Inserter Once the appropriate size acetabular shell is selected and opened on the sterile field, it can be placed on a table with the inner surface of the shell face up. The alignment arrow on the shaft of the inserter is to be aligned with the retaining ring window in the rim of the cup. Place the expanding end of the inserter into the circumferential groove located on the inner surface of the shell. A quarter turn of the knob located in the middle of the inserter will lock the shell in place (Figure 2). The shell inserter is then positioned in the acetabulum to ensure anatomical placement of the shell. As a reference, the orientation guides on the shell inserter indicate 45 degrees of abduction (inclination bar) and 20 degrees anteversion (anteversion bar) (Figure 3). The shaft of the inserter should point to the posterior-superior iliac spine. Light blows are used to engage the acetabular rim while frequent checks are made on the position of the component. Figure 3 Acetabular Shell Insertion with Orientation Guides The acetabular shell can be disengaged from the inserterextractor at any time and readily reattached as needed. When the rim is engaged and the desired position is achieved, the shell is seated with firm impacts. 3

StelKast Acetabular Surgical Protocol Threaded End Inserter Once the appropriate size Provident Apical Threaded Hole Shell is selected and opened on the sterile field, it can be assembled to the Threaded End Inserter (Figure 4). The Threaded End Inserter is only for use with the Provident Apical Threaded Hole Shell. It is important that the inserter is fully seated prior to impaction to prevent damage to the inserter or shell. Light blows are used to engage the acetabular rim while frequent checks are made on the position of the component. The acetabular shell can be disengaged from the inserterextractor at any time and reattached as needed. When the rim is engaged and the desired position is achieved, the shell is seated with firm impacts. Figure 4 Provident Apical Threaded Hole Shell Assembly to Threaded End Inserter Screw Fixation The acetabular components have either cluster or multiple hole options. When a snug fit cannot be obtained on trial or acetabular defects will not allow a rim fit, an acetabular component with screws should be used. Screws are available in 5 mm increments from 15 mm to 40 mm and in 10 mm increments from 40 mm to mm. Once the cup is seated in the acetabulum, the drill guide can be placed into the screw hole on the inside of the acetabular shell. A suitable drill bit can then be carefully inserted into the drill guide to prepare the bone for the screw (Figure 6, Step 1). Figure 5 Preparation for and Insertion of Screws After drilling, the depth gauge can be inserted into the screw hole to determine the appropriate length screw. Once the screw is selected, it can be grasped with the screw holding forceps and inserted into the acetabular shell (Figure 6, Step 2). The selected screwdriver shaft and ratchet handle can be assembled and used to drive the screw into the bone. Ensure that the screw head is below the inner surface of the shell. Note: If using a flexible drill, the screw holding forceps can be used to apply a downward force on the drill. The flexible drills should not be operated in reverse. 4

Insertion of the Polyethylene Liner A hooded or non-hooded trial liner can be trialed for position and stability. The appropriate acetabular liner is then dialed into position. The liner is secured when it is pushed into the shell and locked by the retaining ring. The force necessary to seat it can be applied using digital pressure only (Figure 6). If any seating resistance is encountered, the liner is withdrawn and the shell examined for debris or soft tissue impingement. Extraction of the Polyethylene Liner Figure 6 Insertion of Acetabular Liner or Trial Occasionally at the time of final trial reduction it may be desirable to rotate the liner due to malpositioning. The polyethylene liner may be withdrawn from the shell using the liner retaining ring forceps to expand the retaining ring (Figure 7). This extraction should not harm either the liner or the shell. The liner is then withdrawn, repositioned and reseated. Figure 7 Removal of Polyethylene Liner, if Required 5

GENERAL PRODUCT INFORMATION Through the advancement of partial and total hip joint replacement, the surgeon has been provided with a means of restoring mobility, correcting deformity, and reducing pain for many patients. While the prostheses used are largely successful in attaining these goals, it must be recognized that they are manufactured from metal, ceramic, and plastic materials and that any joint replacement, therefore, cannot be expected to withstand activity levels and loads as would normal healthy bone. In addition, the system will not be as strong, reliable, or durable as a natural human joint. INDICATIONS FOR USE Stelkast Company hip implant components are indicated for single use only in skeletally mature individuals undergoing reconstruction of severely disabled and/or very painful joints. If cemented fixation is required for the component being used, then the respective component label will include the statement; This device is intended for cemented use only. Stelkast Hip System components are indicated for either cemented or cementless use for reconstruction of the articulating surface of the femoral and/or acetabular portions of the hip that are severely disabled and/or very painful resulting from non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis, rheumatoid arthritis, traumatic arthritis, correction of functional deformity, treatment of nonunion, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement unmanageable using other techniques. The components can be used for primary hip implant or for hip revision of a failed total hip arthroplasty. CONTRAINDICATIONS Stelkast Company hip implant components are contraindicated in patients with active infection, patients without sufficient bone stock to allow appropriate insertion and fixation of the prosthesis, patients without sufficient soft tissue integrity to provide adequate stability, muscle laxity or inadequate soft tissue for proper function and healing, any pathological conditions that would interfere with the performance of the system and in patients with either mental or neuromuscular disorders that do not allow control of the affected joint, and in patients whose weight, age or activity level might cause extreme loads and early failure of the system. The Biolox Delta and Zirconia ceramic heads are contraindicated for use with any other than an UHMWPE cup or metal backed UHMWPE cup WARNINGS AND PRECAUTIONS Familiarity with and attention to appropriate surgical technique for hip joint arthroplasty and the Stelkast implant system is essential for success of the procedure. Improper position of the components could result in dislocation. Only surgeons who have reviewed the literature regarding hip surgery and have had training in the technique should utilize the device. Patient selection is based on age, bone stock and size. The surgeon or his designee should instruct patients in the limitations of the prosthesis, and these patients should be taught to govern their activities accordingly. Patient lifestyles must be evaluated by the physician, and patient properly advised of any required modifications. Hip implant components must not be reused. The surgeon must not allow damage to polished bearing surfaces because this may accelerate wear of the components. Any alteration or damage to a component may reduce fatigue strength and could result in failure under load. Any prostheses so damaged must not be used. In the case of hip cup revisions in which the hip stem is not revised, ceramic femoral heads could break because of trunnion damage or mismatch. Care must be taken when ceramic heads are implanted to avoid overuse of force during seating the head on the trunnion. The stem trunnion and head bore should be dry and free of contamination prior to assembly of a ceramic head to the trunnion. Components of Stelkast Company hip implants should not be used with those of another manufacturer since articular and dimensional compatibility cannot be assured, including possible femoral head taper mismatch. Only Stelkast femoral heads should be used with Stelkast hip stems. Hip implant components have not been evaluated for safety and compatibility in the MR environment. Hip implant components have not been tested for heating or migration in the MR environment. ADVERSE EVENTS As with all hip joint implant systems, potential adverse effects include infection, loosening of the components, breakage, bending or disassembly of the components, or change in position of the components. There have been reports of sensitivity reactions to the implant components. Other potential adverse effects of hip implant joint surgery include neurovascular damage, dislocation, thromboembolic disease, acetabular pain, component failure and wear debris and other less common adverse effects. On rare occasions, amputations have been necessary. STERILITY AND HANDLING Each Stelkast Company hip implant component is supplied sterile in double sealed containers maintaining double sterile barriers. If the seals or containers are breached, then the component should not be used. The components are not represented to be "pyrogen-free." Metal and ceramic parts as well as polyethylene (UHMWPe) parts and/or components containing polyethylene or polymethylmethacrylate (PMMA) are supplied exposed to a minimum of 2.5 Mrad of gamma irradiation or Ethylene Oxide sterilization and must be kept unopened in the double protective packaging until implantation. The sterilization method used is listed on the respective component label. The sterile container is to be checked for possible damage. Do not use any component if the packages have been breached. Resterilization by any method is ruled out. Care should be utilized in the handling of the components to minimize contamination of the component surfaces. Do not allow porous surfaces to come in contact with cloth or other fiber releasing materials. In using cement for fixation, the surgeon should use care to ensure complete cement support on all parts of the prosthesis embedded in bone cement. UTILIZATION AND IMPLANTATION Selection of Stelkast Company hip implant components depends on the judgment of the surgeon with regard to the relationship to the requirements of the patient. The surgeon should become thoroughly familiar with the technique of implantation of the prostheses by: (1) appropriate reading of the literature, and (2) training in the operative skills and techniques required for hip joint arthroplasty surgery. MATERIALS USED The materials used are listed on the respective product label. INFORMATION For any further information, please contact the supplier. Please be sure to refer to the Catalog Number designated with REF CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician. 6

StelKast Acetabular Product Specifications - Including ProForm /Provident & Systems Acetabular Shells / Liners Titanium Shell with textured finishes Titanium plasma spray Titanium porous bead Locking ring to secure liner Congruent high luster finish ID Snap-in Polyethylene liner Clustered, multiple and no-hole designs Moderately Cross-linked ProArTM Polyethylene Highly Cross-linked EXpTM Polyethylene Non-hooded and 10º Hooded Options Screws 6.5mm SC1156*/ SC2677 Shells ProForm Porous Beaded 15 Provident Plasma Sprayed No Hole SC1408100 Cluster SC1408200 Multi-Hole SC1408300 Cluster SC1217 Apical Thread Cluster SC3546 46 46 46 46 48 48 48 48 64 52 52 66 52 52 54 54 68 54 54 56 56 70 56 56 58 58 72 58 58 74 76 64 64 64 66 66 66 68 68 68 70 70 72 72 Indicates Special Order Components * Shell SC3458-52 is compatible only with SC3459-52 & SC3474-52 Plasma Sprayed 20 Cluster SC3458 25 30 35 40 52 * Indicates Special Order Components * SC1156 Screws are not for use with SurpassTM Acetabular System. Liners 7

StelKast Acetabular Product Specifications - Including ProForm /Provident & Systems Liners EXp XLPE ProAr Non-Hooded 28mm SC2542 Non-Hooded 32mm 28mm 32mm 28mm 32mm SC2397 SC2543 SC2398 SC3342 SC3344 4648 * Hooded 4648 36mm 28mm 32mm 36mm SC32/ SC3343 SC3345 SC3349/ SC3459 * SC3474 * 4648 Hooded 4648 52 * 52 * Indicates Special Order Components Liners SC3459-52 and SC3474-52 are compatible only with Shell SC3458-52 Femoral Heads CoCr 28mm SC1151/ SC1152 BIOLOX delta Ceramic 32mm SC2271/ SC2272 36mm SC3261/ SC3346 28mm SC3347 32mm SC3348 36mm SC3295 +10.5 +10.5 +10.5-5 +12 * BIOLOX delta Ceramic Heads are not for use with SurpassTM Acetabular System. Last revised 12-09-13 FM-685 Rev. E 200 Hidden Valley Road McMurray, PA 15317 phone: (724) 941-6368 fax: (724) 941-5987 www.stelkast.com