Serotonin in Plasma. Electrochemistry Discover the difference. Summary. Application Note Clinical & Diagnostics

Similar documents
Serotonin in Urine. Electrochemistry Discover the difference

Metanephrines. in Urine. Clinical & Diagnostics Analysis. Introduction. Application Note ALEXYS - Clinical & Diagnostics

HVA, VMA and 5-HIAA in Urine

Iodide in Milk. Electrochemistry Discover the difference

Bisphenol A in Drinking Water

Abstract. Introduction

Articaine & Epinephrine Injection According to USP Method

retardation in infants. A wide variety of analytical methods for the analysis of

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610

Iodine HPLC Assay. Catalog Number: IOD34-H Tests For Research Use Only. Not for use in diagnostic procedures.

Aminothiols and Disulfides

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

SCIEX Vitamin D 200M Assay for the Topaz System

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Analysis of bisphenol A leaching from baby feeding bottles

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

Betadex Sulfobutyl Ether Sodium According to USP

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

International Journal of Pharma and Bio Sciences

VITAMIN B1 IN WHOLE BLOOD BY FLUORIMETRY - FAST Code Z85010

Vitamin A-E Serum HPLC Analysis Kit

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Determination of propranolol in dog plasma by HPLC method

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Author. Introduction. Abstract

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Mono- and Disaccharides

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Journal of Chemical and Pharmaceutical Research

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Alexys Neurotransmitter Analyzer for Monoamines and Metabolites

ALEXYS Neurotransmitter Analyzer for GABA & Glutamate, Histamine, LNAAs and other Amino Acids

[ APPLICATION NOTE ] UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research INTRODUCTION APPLICATION BENEFITS

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

Immunosuppressants in Whole Blood On-Line Analysis

Application Note. Author. Abstract. Introduction. Food Safety

Compilation of Clinical Applications

Determination of Clarithromycin in Human Plasma by LC-EI Tandem Mass Spectrometry: Application to Bioequivalence Study

MALDI Sepsityper Kit

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

CHAPTER 3: ANALYTICAL METHOD DEVELOPMENT AND VALIDATION

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Glutamine Kit. For the determination of glutamine and glutamate in human EDTA plasma and serum. For research use only K 7732.

Bioequivalence Studies of Two Formulations of Famciclovir Tablets by HPLC Method

New Automated Screening System for the Determination of Basic Compounds in Urine by On-Line Extraction-HPLC- DAD

colorimetric sandwich ELISA kit datasheet

Carbohydrates in Food

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Determination and pharmacokinetics of manidipine in human plasma by HPLC/ESIMS

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BACLOFEN IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

Supporting Information

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Product Catalogue 2014 / 15. Solutions for Clinical Diagnostics

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride

NOVEL RP-HPLC METHOD. B.Lakshmi et a. concentration range KEY INTRODUCTION. Diltiazem is used to. . It works by of contractionn of the. (dilate).

Pelagia Research Library

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell culture

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

SIMPLE AND VALIDATED RP-HPLC METHOD FOR THE ESTIMATION OF CARBOPLATIN IN BULK AND FORMULATION DOSAGE FORM. Subhashini.Edla* B.

Application Note. Authors. Abstract. Food

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA

Offline and online sample extraction for the quantification of benzodiazepines in human plasma or serum for clinical research

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Successful implementation of online SPE LC-MS/MS in the clinical research laboratory

RayBio Human Granzyme B ELISA Kit

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

Betadex Sulfobutyl Ether Sodium according to USP

Determination of red blood cell fatty acid profiles in clinical research

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

Transcription:

Application Note Clinical & Diagnostics The most selective LC-EC applications for Clinical & Diagnostics analysis Serotonin Catecholamines Serotonin Metanephrines VMA HVA 5-HIAA PET imaging tracer Fluorodeoxyglucose (FDG) FDG impurities Sulfides Homocysteine Glutathione Disulfides Vitamins, minerals A, C, D, E, and K Iodide Q10, Ubiquinols n Standardized, fast and reliable assay n Kit for standardized sample prep n Robust and reproducible Summary HPLC with electrochemical detection has been established as a fast and reliable method for the determination of serotonin, catecholamines and metabolites in plasma and urine [1-5]. The ALEXYS Clinical Analyzer together with a commercially available kit has been evaluated. This dedicated system has proven to be robust and reproducible in routine analysis. ALEXYS Application Note #1_00_05 Electrochemistry Discover the difference

Introduction Serotonin is involved in a variety of physiological processes, including smooth muscle contraction, blood pressure regulation and both central and peripheral nervous system neuro transmission. Abnormalities in serotonin-related processes give rise to various pathological conditions. Aberrations in its central nervous system function are thought to be involved in anorexia, anxiety, depression and schizophrenia. The quantitatively most pronounced aberration in serotonin production is encountered in patients with carcinoid tumors []. The diagnostic assessment of the carcinoid syndrome therefore can be performed by the determination of 5-HIAA in urine as well as of serotonin in plasma/serum and urine. The determination of 5-HIAA in urine serves as the basic investigation. The additional determination of serotonin in plasma/serum and urine is considered to provide complementary information. Method A complete kit contains all the necessary chemicals and materials for sample preparation and analysis. Extracted plasma samples are processed as follows: n 00 µl of extracted plasma sample is mixed with 10 µl internal standard (IS) and mixed for 5 seconds (vortex mixer). n 00 µl precipitation reagent is added to the solution and mixed for 5 seconds (vortex mixer). n The solution is subsequently centrifuged for 1 minute at 10000 x g. n The supernatant is collected and 0 µl injected in the LC system. Table 1 Set-up HPLC Flow rate Sample Mobile phase Temperature E-cell Range ALEXYS Clinical Analyzer 1.0 ml/min 10 µl, supernatant of precipitated plasma solution HPLC kit buffer (recycled during experiments) D SDC 30 C (separation & detection), AS110: C (sample cooling) 550 mv (vs. Ag/AgCl sat d) 50 na/v I-cell 0. 3.0 na ADF Analysis time 0.1 Hz < 10 minutes Figure 1: ALEXYS Clinical Analyzer. na 10 8 Serotonine IS 0 0 1 3 5 7 8 min Figure : Analysis of 10 µl plasma calibrator with a concentration of 19 µg/l serotonin.

For details about the extraction procedure of plasma from blood samples see reference [11]. The quantification of serotonin in plasma samples is performed by means of a single-point calibration method using a plasma calibrator. The plasma calibrator supplied in the kit is a lyophilized plasma sample with a known amount of serotonin. The plasma calibrator should be reconstituted by adding 5 ml HPLC-grade water and processed the same way as the extracted plasma samples. An example chromatogram of a plasma calibrator analysis is shown in figure. An internal standard method is used to compensate for recovery losses during the sample preparation step. Results Analysis of controls For validation of the analytical method plasma controls have been analyzed in both the normal (level I) and the pathological range (level II). The controls are lyophilized plasma samples which should be reconstituted by adding 5 ml HPLCgrade water and have to be processed in the same way as the plasma samples. Both Control I and Control II were analyzed and the analyte concentrations quantified using the plasma calibrator. Table Measured serotonin concentration in plasma controls level I and II Component Specified (µg/l) Specified Min Max (µg/l) Control level I Control level II RSD (%) 78 11 95 1.8 31 37 90.0 Measured serotonin concentration in plasma controls level I and II, n = (injections) x 3 (days). Concentration range specified is given for reference (source: data sheet supplied with controls). For both plasma controls level I and II the determined serotonin concentrations were within the specified concentration ranges (see table ). na 5 Serotonine IS 3 1 0 0 1 3 5 7 8 min Figure 3: Overlay of chromatograms of 10 µl injections of plasma control level I (red) and II (blue). 3

Analysis of plasma samples Plasma controls, level I (sample A) and level II (sample B), were used for the statistical evaluation of the method. The intra- na 10 assay precision of the method was determined for sample A and B. The plasma samples were worked-up 5 times and duplicate analysis were performed to determine the relative standard deviation (RSD, %). This procedure was repeated for 3 days. For plasma sample B an overlay is shown in figure 8 Serotonin IS 3 of 10 chromatograms (5 samples x duplicate injections) recorded at day 1. The RSD s found for sample A and B were smaller than 3% (see table 3). Table 3 Intra-assay precision for the analysis of serotonin in plasma sample A and B Component Sample A RSD (%) Day 1 1.7 93 Day.7 91 Day 3 1.0 95 Sample B Conc. (µg/l) Day 1 1.1 9 Day 1.8 95 Day 3 1. 9 Intra-assay precision for the analysis of serotonin in plasma sample A and B, n= 5 (samples) x (injections). For all plasma samples, controls and calibrator recoveries typically in the range of 80 100 % were found, compared to a standard. The concentration limit of detection (CLOD) for the method was approximately 0.7 µg/l for serotonin. The CLOD is calculated based on a 10 µl injection and defined as the concentration that gives a signal that is three times the peakto-peak noise. The method is linear for the determination of serotonin in the concentration range from 1 1000 µg/l [11]. The inter-assay precision of the method was determined over a time period of three days for sample A and B. Both samples were worked-up 5 times and analyzed (duplicate injection) every single day. From the obtained data the relative standard deviation calculated. Table Inter-assay precision for the analysis of serotonin in sample A and B Component Sample A Sample B 0 0 1 3 5 7 8 min Figure : Overlay of 10 chromatograms of 10 µl injections of plasma sample B. RSD (%) The RSD s found for the analysis of sample A and B were smaller than 3% (see table ).. 93 Conc. (µg/l) 1.5 95 Inter-assay precision for the analysis of serotonin in sample A and B. n= 5 (samples) x (duplicate injections) x (days).

References 1. Thomas, Labor und Diagnose: Indikation und Bewertung von Laborbefunden, TH-Books, Verlagsgesellschaft, Frankfurt/Main, 5th ed., (1998) 107-1078. I.P. Kema, E.G.E. de Vries, F.A.J. Muskiet, J Chromatogr., B 77, (000) 33-8 3. D. Mc Cormic, Gastroenterol Nurs., 5(3), (00) 105-111. D. Donaldson, J R Soc Health., 10(), (000) 78 5. E. Pussard, N. Guigueno, O. Adam, J.-F. Giudicelli, Clin Chem., (7), (199) 108-1091. S. Jovanovic, D. Mirkovic, N. Majkic-Singh, Clin Lab., (1998) 3-8 7. M. Picard, D. Olichon, J. Gomber, J. Chromatogr., 31, (1985) 5-51 8. E. Flachaire, C. Beney, A. Berthier, J. Salandre, C. Quincy, B. Renaud, Clin. Chem., 3 (1), (1990) 117-10 9. W. G. Meijer, I. P. Kema, M. Volmer, P. H. B. Willemse, E. G. E de Vries, Clin Chem., (10) (000) 1588-159. 10. R.T. Peaston and C. Weinkove, Ann. Clin. Biochem., 1, (00) 17 38 11. Recipe, Instruction manual for the serotonin in plasma kit, version,.0 (00) Conclusion The ALEXYS Clinical Analyzer in combination with a commercially available kit provides a standardized method for fast and reliable analysis of serotonin in plasma. 5

Ordering information 180.0039E ALEXYS Clinical Analyzer Antec Scientific (USA) info@antecscientific.com www.antecscientific.com T 888 57 001 For research purpose only. The information shown in this communication is solely to demonstrate the applicability of the ALEXYS system. The actual performance may be affected by factors beyond Antec s control. Specifications mentioned in this application note are subject to change without further notice. Antec Scientific (worldwide) info@antecscientific.com www.antecscientific.com T +31 71 5813333