Distal Radius Surgical Technique Guide

Similar documents
3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

System. Humeral Nail. Surgical Technique

AcUMEDr. FoREARM ROD SYSTEM

Conventus CAGE PH Surgical Techniques

SYNFLATE SYSTEM SURGICAL TECHNIQUE

Surgical Technique Guide

Double Engine Orthopedic Bone Nail System Universal Humeral Nail

IM Hip Nailing Surgical Technique

Zimmer ITST Intertrochanteric/ Subtrochanteric Fixation System. Abbreviated Surgical Technique

Surgical Technique & Product Catalogue. Guide for Open & MIS Procedures

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

Distal Ulnar Locking Plate

TABLE OF CONTENTS. 2 (8144 Rev 2)

Balloon in Balloon (BIB )

TRAUMATOLOGY. Trochanter

RECOMMENDED INSTRUCTIONS FOR USE

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

FASSIER DUVAL TELESCOPIC IM SYSTEM S RESCUE SYSTEM 2.0

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:

PediNail Pediatric Femoral Nail

FAST1 Intraosseous Infusion System. Training Session

SURGICAL TECHNIQUE GUIDE

Surgical Technique Guide

01/2006, Vidacare Corporation, all rights reserved. Vidacare, EZ-IO Product System and EZ-Connect are trademarks of the Vidacare Corporation.

Directions For Use. All directions should be read before use

fassier DUVal TelescoPIc IM system s RESCUE SYSTEM 2.0

ER REBOA Catheter. Instructions for Use

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

humerus InSafeLOCK Nail

Surgical Technique. Intramedullary locked Nailing With Screws for Humerus Fractures Solid/Cannulated. Humeral Interlocking Nail.

AcUMEDr. Olecranon Threaded Compression Rod

Technique Guide. SureLock Distal Targeting Device. C-arm guided targeting for trochanteric fixation nail.

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Zimmer Natural Nail System

Surgical Technique. Forearm Fracture Solutions

DISTAL ELBOW SET. proximal ulna plate SURGICAL TECHNIQUE GUIDE

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

Education for Self Administration of Intravenous Therapy HOME IV THERAPY PICC. Portacath

How to Use ENBREL : Vial Adapter Method

Standard Operating Procedure for cannulation

Quick Reference Guide

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER

US Patent No. 6,309,396B1. G. David Ritland, M.D.

CLARIVEIN INFUSION CATHETER

Surgical Technique.

Title: EZ-IO. Effective Date: January SOG Number: EMS Rescinds:

Forearm Fracture Solutions. Surgical Technique

Taperloc Complete Hip System. Surgical Technique

U2 PSA. Revision Knee. Surgical Protocol

AXS Catalyst Distal Access Catheter

NeoGen Femoral Nail System

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

M.I.S. MAKE IT SMART IN ONE SYSTEM. Surgical Technique. Hip Knee Spine Navigation

TITANIUM TIBIAL NAIL SySTEM

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

Nit-Occlud. Coil System for PDA Closure IMPLANTATION POCKET GUIDE. Rx only CV / B. Braun Interventional Systems Inc.

Technique Guide Hammertoe Correction System

PERFORATED CLICK X Augmentable pedicle screws for osteoporotic bone

Phoenix Tibial Nail System

Mini External Fixator.

Technique Guide. *smith&nephew SPEEDSCREW Fully Threaded Knotless Implant

Sirus Antegrade Femoral Nail System Surgical Technique

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

STRENGTH FROM WITHIN. Surgical Technique for Representatives

Z-MED II BALLOON AORTIC AND PULMONIC VALVULOPLASTY CATHETER. Instructions for Use

A Locking IM Rod that won't back out. Simple and straight to the point! SURGICAL TECHNIQUE

Uncompromised Exposure

Directions For Use. All directions should be read before use. Page 1 of 8

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Olecranon Locking Plate II

Imbibe Bone marrow aspiration needle. Operative technique

GREENS SURGICALS. Redefining Excellence INSTRUMENT SYSTEM PREPARED BY: DR. VINAY KUMAR

Femoral Recon Nail System FRN

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

For Intramedullary Fixation of Proximal Femoral Fractures. Surgical Technique

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems.

Expert A2FN. Designed for small statured patients.

LUMBAR POSTERIOR MINIMALLY INVASIVE SYSTEM. Surgical Technique

ARROW EZ-IO Intraosseous Vascular Access System Procedure Template

TIBIAL NAILING SYSTEM OPTIONS MADE EASY

limbsandthings.com Advanced Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

Aesculap Targon TX. Intramedullary Nail for Tibial Fractures...going to X-tremes. Aesculap Orthopaedics

Femoral Recon Nail System FRN

The AperFix II System

M/DN Femoral Interlocking & Recon Nail Intramedullary Fixation Surgical Technique

I SEE THE BROADEST RANGE OF PRODUCTS THRU my smallest possible incision.*

THE FIRST PERCUTANEOUS LOCKED FLEXIBLE INTRAMEDULARY NAIL SYSTEM FOR HAND FRACTURES

Surgical Technique. DISCLOSURE: This device is not approved for sale in the U.S.A. Customer Service:

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

Asnis. Micro Cannulated screw system. Xpress operative technique

Correction System. Surgical Technique

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

Transcription:

Distal Radius Surgical Technique Guide

About IlluminOss IlluminOss minimally invasive procedure incorporates a PET or Dacron balloon catheter that is delivered through a small pathway into the intramedullary canal transiting the fracture site. Using a standard syringe, IlluminOss light activated, biocompatible monomer is infused into the balloon, causing it to expand, fill and conform to the patients intramedullary canal. Only upon the activation of IlluminOss visible light source (436nm) will the monomer infused balloon begin to cure. The cured implant stabilizes the fracture and provides both longitudinal strength and rotational stability to the affected bone. Features & Benefits A patient conforming implant for rapid repair and stabilization of fractures. A small diameter, flexible catheter allows surgeons to determine the entry position of the implant unlike a rigid metal implant. The implant expands within the patient s intramedullary canal, filling and conforming to the patients unique canal geometry. The procedure to repair and stabilize the bone is a simple and straightforward which may provide faster operative times benefiting the patient. The implant is radiolucent allowing for better visualization of the cortex during the post operative treatment phase. Cures on demand, only through the applications of visible light. Screws and plates can be used anywhere along the implant. Indication The IlluminOss System is indicated for use in fracture alignment reduction. It provides stabilization for bone fractures using a minimally invasive technique in which the bone is not subjected to significant weight bearing forces. This document is intended as an outline for the surgical technique of the repair of the distal radius. The IlluminOss implant can be used for either the left or the right radius. Pre Operative Set Up Ensure that the IlluminOss delivery instrumentation has been sterilized and is delivered to the OR. Set-up and activate the light box prior to start of the procedure to confirm operative status. Note: The light box must be set-up outside the sterile field and on the same side as the target radius nearest to pathway being made into the of the patient. The light guide is not sterile it remains outside of the surgical field. The light fiber is a predetermined length (183cm) and ensure that the light box is close enough to make the connection. Implant Diameter & Length The IlluminOss implant range in a variety of diameters and lengths. The determination of an implant length and diameter maybe preformed pre-operatively or after the start of the procedure. In determining the appropriate IlluminOss implant length to select, measure the radius from the radial styloid to the fracture site. The IlluminOss implant should span across the length of the fracture site in order to stabilize it. Select an implant that achieves cortical contact along the length of the fracture.

Reduce Fracture & Creating Initial Pathway Position the patient in the supine position and reduce the fracture by traditional methods. A stitch incision should be made at the radial styloid. A straight awl is used to make an initial entry portal at the radial styloid (Figure 1). Check the position with AP and lateral views. Note: The operating table must be radiolucent as the arm must be visualized in two planes using the image intensifier. Figure 1 Insert Cannulated Awl Into Canal Insert the cannulated awl into the initial pathway (Figure 2). The cannulated awl enlarges the canal allowing for the sheath and dilator to be placed within the intramedullary canal. Figure 2 Insert Guidewire Into Cannulated Awl Deliver the guidewire into the medullary canal through the cannulated awl. Once in position, remove the stylet from the back of the awl and insert the ball-tipped guidewire through the awl and across the fracture (Figure 3). Remove the cannulated awl leaving the guidewire in position. Figure 3 Preparation Of Canal Place the IlluminOss flexible cannulated burrs over the ball tip guidewire to clean the canal providing proper space for delivery of the implant (Figure 4). Start with the smallest diameter burr mounted on either a power drill or a hand reamer to clear the canal. Burrs are used in 1.0mm increments to achieve a minimum diameter of 5.5mm within the medullary canal. After clearing the canal, remove the burr from the canal leaving the ball tip guidewire in place across the fracture site. Note: Select the desired implant size and deliver to the sterile field. Figure 4

Insert Dilator & Sheath Insert the dilator into the tear away sheath. Verify that the guidewire is in position crossing the fracture. Place the dilator and tear away sheath assembly over the guidewire into the intramedullary canal (Figure 5). Confirm positioning of the sheath assembly via fluoroscopy. Once in position, remove the dilator and guidewire, leaving the tear away sheath in place across the fracture site. Remove Air From Catheter Carefully remove the catheter assembly from the sterile packaging. Leave the protective tube covering the balloon in place as this will assist in the priming preparation of the implant. Attach the empty 20cc syringe provided in the kit to the black stopcock luer and open the valve. Evacuate all of the air out of the implant by drawing a vacuum with the syringe, and then close the stopcock to maintain the vacuum (Figure 6). Detach syringe from stopcock luer and expel any collected air out of the syringe. Repeat this process to ensure all air has been removed from the balloon catheter. Close the luer to maintain the vacuum within the implant. Warning: Do not use an implant that will not hold a vacuum. Discard that implant and replace it with a new sterile implant. Figure 5 Figure 6 Figure 6 Transfer Monomer Into Syringe Remove the blue cap from the monomer vial and insert the transfer spike into the top of the vial. Attach the syringe to the transfer spike and, turn assembly over, and slowly draw the monomer into the syringe (Figure 7). Consolidate any air bubbles and expel any residual air from the syringe. Prime Distal End Of Balloon Attach the syringe containing the monomer to the closed stopcock luer. Slide the protective tube covering the balloon back towards the syringe about 15mm, exposing the front portion of the balloon (Figure 8). Open the stopcock valve on the catheter, where the residual vacuum will pull and infuse monomer slowly into the catheter. Figure 7 Figure 8 Apply some pressure to the plunger on the syringe for several seconds, the monomer will travel the entire length of the balloon catheter. The tip of the exposed balloon beyond the protective tube shall start to slightly expand in diameter (Figure 9). Note: Do not try and fully inflate the balloon to its full size, the purpose of this step is to transfer monomer to the distal end of the implant Figure 9

Prime Proximal End Of Balloon When sufficient monomer has been withdrawn from the distal end of the balloon, causing the balloon to deflate, the protective tube is advanced forward, away from the syringe, and over the tip of the catheter. Leave approximately 20mm of the protective tube on the balloon. The middle portion of the balloon catheter is exposed while the tip of the balloon is still contained within the confines of the protective tube. Gently infuse a small amount of monomer into the balloon by depressing on the syringe plunger. With two fingers on the outside of the balloon gently advance in a wiping motion the monomer forward towards the distal tip of the syringe. Pull a vacuum on the syringe again and at the same time gently pull the protective tube back towards the syringe into position covering the entire balloon (Figure 10). The simultaneous action of a vacuum drawn on the syringe and the compression of the protective tube on the balloon will expel all the air from the balloon catheter into the syringe. Leave the monomer filled syringe attached to the catheter. The IlluminOss implant has now been prepared and is ready for implantation. Figure 10 Note: Do not attempt to fully inflate the balloon as it may be difficult to fully deflate and reinsert into the tube. Do not attempt to perform the balloon catheter preparation within the medullary canal. Insert The Balloon Catheter Into Sheath Remove the protective tube from the balloon catheter and introduce the prepared balloon into the tear away sheath previously positioned in the intramedullary canal (Figure 11). For proper position use fluoroscopy, ensuring that the fracture reduction has been maintained and the sheath is still spanning the fracture site. Note: Care must be taken when inserting the prepared catheter through the sheath. Support the length of the balloon catheter during insertion. Do not force or significantly bend the balloon during its delivery into the sheath as damage to the implant may occur. Figure 11 Remove Tear Away Sheath While holding the balloon catheter in position, break the wings of the tear away sheath and slowly separate the sheath in half while withdrawing it from the canal. Remove and discard the sheath (Figure 12). The removal of the sheath leaves the balloon exposed within the canal. Use fluoroscopy to confirm the position of the balloon spanning the fracture site and ensure the fracture remains sufficiently reduced. Minor adjustments to the balloon position may be required. Figure 12

Infuse Balloon With Monomer Infuse the monomer from the attached 20cc syringe by opening valve and applying moderate pressure to syringe plunger (Figure 13). With the infusion of monomer into the balloon, the spiral radiopaque marker stripe on the outside of the balloon allows visual guidance of implant conforming to the canal as well as its positioning along the length of the bone. Once resistance is felt on the syringe plunger, or it cannot be advanced any further, close the stopcock valve (Figure 14). Reconfirm fracture alignment with fluoroscopy. Multiple vials of monomer may have to be opened to achieve a fully filled implant. Leave the syringe attached to the catheter. Figure 13 Warning: If adjustment of either the balloon position or the bone is required, depressurize balloon by opening the stopcock and aspirating monomer out of the implant with the syringe to disengage it from contact with the cortex of the canal. Carefully reposition balloon or reduce the fracture. Attempts at repositioning a fully filled balloon may cause damage to the implant. Figure 14 Photodynamic Curing Process Pass the end of the light fiber off the sterile field and connect it to the light guide until it snaps in place. Insert the timer key into the slot on the front of the light box. Ensure the timer changes to the prescribed time shown on the timer key. Toggle the foot pedal switch on the front of the light box from the standby position to the enabled position. Depress and release the foot pedal to initiate the light curing cycle (Figure 15). The system runs automatically and the timer counts down the residual time until the implant is cured. At the completion of the curing cycle no further light is delivered to the implant. After the curing process has completed, unscrew the blue cap and remove light fiber from balloon catheter and discard. Note: Ensure that the proper timer key is being used by comparing timer key setting to the setting on the timer key flag located on the light fiber tether. Figure 15 Warning: Do not stop the curing process or remove the light fiber prior to the completion of the curing cycle. Cut The Proximal End Of The Catheter Using a pair of surgical scissors, cut the braided catheter tube as far back to the plastic connector as possible and then discard (Figure 16). Note: Cutting the braided catheter shorter than as described above will cause difficulty in separating it from the implant. Figure 16

Place Stabilizer Over Catheter Slide the stabilizer over the catheter shaft and advance it forward to contact the proximal end of the implant (Figure 17). Use fluoroscopic imaging to ensure that the serrated end of the stabilizer is in contact the proximal end of the implant (Figure 17). Rotate the stabilizer knob clockwise several times while applying moderate pressure to the stabilizer to score the end of the PET balloon. Figure 17 Attach Slap Hammer To Stabilizer Open the slap hammer by pulling on the lever exposing the jaw tips. Slide the jaw tips over the catheter protruding from the stabilizer. Once the jaw tips are over the catheter, close the handle lever to close the slap hammer causing it to tighten and grip onto the catheter (Figure 18). Removal Of Catheter From Implant Hold the stabilizer handle with one hand and apply forward pressure against the proximal end of the balloon. With the second hand, grasp the sliding hammer portion of the slap hammer instrument. Apply in one quick full, sharp stroke, separating the catheter from the implant (Figure 19). Figure 18 Implant Strength & Stability The implant provides longitudinal strength and rotational stability over it s length (Figure 20). Screws and plates can be used in conjunction anywhere along the length of the implant. Should the use of ancillary fixation be required, do not select a screw size that is greater than one third the diameter of the IlluminOss implant. Figure 19 Figure 20

Notes

Notes

Notes Contraindications This product is contraindicated in patients who: are considered skeletally immature; have an active or incompletely treated infection that could involve the site where the device will be implanted; are allergic to any of the implant materials or to dental glue; have an intramedullary canal measuring smaller than the diameter of the sheath provided at the site of the fracture; are uncooperative or who have a neurologic disorder and, or are incapable of following directions; have metabolic disorders which may impair bone formation, have osteomalacia, distant foci of infections which may spread to the implant site, have marked bone loss or bone resorption in the opinion of the surgeon would preclude the use of a stand alone implant, have vascular insufficiency, muscular atrophy, or neuro-muscular disease; have open fractures with severe contamination; have extremely comminuted fractures where insufficient holding power of the balloon on the intramedullary canal is probable; or in patients for whom delivery sheath is unable to cross fracture site after proper fracture reduction and realignment.this information should not constrain the surgeon nor restrict medical judgment and is not intended to impinge upon the practice of medicine. It is, instead, intended to augment the professional skills of the surgeon and to serve as a ready reference source in the use of the IlluminOss product.

IlluminOss Medical Inc 993 Waterman Avenue East Providence, RI 02914 Phone: (401) 714-0008 Fax: (401) 714-0009 www.illuminoss.com 900477.A This Product Is Investigational In The United States. 0086 EC REP Emergo Europe Molenstraat 15 2513 BH The Hague The Netherlands IlluminOss Medical Inc. 993 Waterman Avenue East Providence, RI 02914 U.S.A. +1 (401) 714-0008