Thermo Scientific. Acclaim C30 Columns. Product Manual. P/N: February Part of Thermo Fisher Scientific

Similar documents
Acclaim C30 Column. Standards in Isopropanol. Saponified Chicken Fat Minutes

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

GlycanPac AXH-1 Columns

C30 ISOMERS HAVE MET THEIR MATCH

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Ultra Columns. also available. ordering note

Ultra Columns HPLC COLUMNS

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

PAPRIKA EXTRACT SYNONYMS DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Determination of Water- and Fat-Soluble Vitamins in Nutritional Supplements by HPLC with UV Detection

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

The Raptor HILIC-Si Column

Analytical and Preparative SFC Columns

RITONAVIRI COMPRESSI RITONAVIR TABLETS. Final text for addition to The International Pharmacopoeia (July 2012)

Sepax Technologies, Inc.

Title Revision n date

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

GlycanPac AXR-1 Columns

ACE C18-AR Use the Power!

SeQuant ZIC -HILIC For all who expect more...

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006)

Restek Ultra II HPLC Columns

Hyper-fast & Super-rugged

SeQuant ZIC -HILIC For all who expect more...

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015)

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

The HPLC Preparative Scale-Up of Soybean Phospholipids Application

LC-Based Lipidomics Analysis on QTRAP Instruments

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Impurity Profiling of Carbamazepine by HPLC/UV

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Ultimate Core Performance to Maximize Your Investment

Relative Measurement of Zeaxanthin Stereoisomers by Chiral HPLC

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Agilent Technologies Prep LC Columns

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras)

Isolation of five carotenoid compounds from tangerine tomatoes

Waters Amide Column Technology For Food Analysis

176 YMC Chiral Columns

LC Columns with Liquid Separation Cell Technology

Chapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:

ARTESUNATE TABLETS: Final text for revision of The International Pharmacopoeia (December 2009) ARTESUNATI COMPRESSI ARTESUNATE TABLETS

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

CHAPTER 8 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) ANALYSIS OF PHYTOCHEMICAL CONSTITUENTS OF M. ROXBURGHIANUS AND P. FRATERNUS PLANT EXTRACTS

HPLC Analysis of Sugars

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow

Roc On with These Dependable LC Columns

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Facile Isolation of Carotenoid Antioxidants from Solanum lycopersicum using Flash Chromatography

SPE Cartridges. All Finneran Products Are Certified. Conditioning Sample application Wash Elution

Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Determination of Inorganic Ions and Organic Acids in Non-Alcoholic Carbonated Beverages

Flupyradifurone. HPLC Method

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Comparison of a UPLC Method across Multiple UHPLC Systems

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA EFAVIRENZ, EMTRICITABINE AND TENOFOVIR TABLETS

EMTRICITABINE AND TENOFOVIR TABLETS

Analysis of HMF by HPLC

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

β-carotene-rich Extract From Dunaliella Salina

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Unequalled durability against water elution. % tr

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis

DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA: CARBAMAZEPINI COMPRESSI - CARBAMAZEPINE TABLETS

Agilent 1260 Infinity Analytical SFC System

Lutein Esters from Tagetes Erecta

IJRPC 2013, 3(2) Nagamallika et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY

Fortis Method Development Options

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON LAMIVUDINE TABLETS

Studies on Stationary Phase Selectivity for Solid-Core Particles

Extended Application Note

TSKgel Hydrophobic Interaction Chromatography Columns

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

Sample Concentration and Analysis of Human Hormones in Drinking Water

COSMOSIL HILIC. HPLC Column for Hydrophilic Interaction

PROPOSAL FOR REVISION OF MONOGRAPH PUBLISHED IN The International Pharmacopoeia: REVISION OF ph test ABACAVIR ORAL SOLUTION (JULY 2012)

BabyBio IMAC columns DATA SHEET DS

Transcription:

Thermo Scientific TM Acclaim C30 Columns Product Manual P/N: 065416-02 February 2012 Part of Thermo Fisher Scientific

Product Manual for Acclaim C30 Columns Page 1 of 16 Product Manual for Acclaim C30 Columns 075718 Acclaim C30, 5µm, Analytical, (4.6 x 250mm) 075719 Acclaim C30, 5µm, Analytical, (4.6 x 150mm) 075723 Acclaim C30, 3µm, Analytical, (4.6 x 150mm) 078660 Acclaim C30, 3µm Analytical, (4.6 x 100mm) 078661 Acclaim C30, 3µm Analytical, (4.6 x 50mm) 075726 Acclaim C30, 3µm, Analytical, (3.0 x 250mm 075724 Acclaim C30, 3µm, Analytical, (3.0 x 150mm) 078662 Acclaim C30, 3µm Analytical, (3.0 x 100mm) 078663 Acclaim C30, 3µm Analytical, (3.0 x 50mm) 075725 Acclaim C30, 3µm, Analytical, (2.1 x 150mm) 078664 Acclaim C30, 3µm Analytical, (2.1 x 250mm) 078665 Acclaim C30, 3µm Analytical, (2.1 x 100mm) 078666 Acclaim C30, 3µm Analytical, (2.1 x 50mm) 075720 Acclaim C30, 5µm, Guard, (4.6 x 10mm) 075721 Acclaim C30, 5µm, Guard, (3.0 x 10mm) 075722 Acclaim C30, 5µm Guard, (2.1 x 10mm) 2012 Thermo Scientific Document No. 065416 Revision 02 February 2012

Product Manual for Acclaim C30 Columns Page 2 of 16 TABLE OF CONTENTS SECTION 1 INTRODUCTION... 3 1.1. Main features... 3 1.2. Physical data... 3 1.3. Specifications and Operational Parameters... 3 1.4. Operational Guidelines... 4 1.5. Ordering Information... 4 SECTION 2 STEP-BY-STEP USER GUIDE... 5 Step 1 Visually inspect the column... 5 Step 2 Mobile phase preparation... 5 Step 3 Set up the LC system... 5 Step 4 Condition the column... 5 Step 5 Reproduce the chromatogram in the Quality Assurance Report... 6 Step 6 Real sample analysis... 6 SECTION 3 COLUMN CARE... 7 SECTION 4 APPLICATIONS... 8 4.1. Shape Selectivity... 8 4.2. Aqueous Compatibility... 9 4.3. Analysis of Carotenoids... 10 4.4. Analysis of Glucocorticosteriods... 11 4.5. Analysis of Water-soluble Vitamins... 12 4.6. Analysis of Triglycerides in Cooking Oils... 13 4.7. Analysis of Cooking Oils... 14 4.8. Phospholipids in Egg Lecithin... 15 4.9. Phospholipids in Egg Lecithin... 16

Product Manual for Acclaim C30 Columns Page 3 of 16 SECTION 1 INTRODUCTION The Acclaim C30 column is designed to provide high shape selectivity for separating hydrophobic, structurally-related isomers, and unique selectivity complementary to other reversed-phase columns (e.g. C18). The C30 stationary phase is based on a covalent modification of C30 alkyl silane onto high-purity, spherical, porous silica gel. This column is complementary to other reversed-phase columns (e.g. C18) in a broad range of applications in pharmaceutical, food & beverage, chemical, environmental, and academia research. 1.1. Main features High shape selectivity. Unique selectivity complementary to other reversed-phase columns. Compatibility with highly aqueous mobile phase. Excellent performance low column bleed, high efficiency and rugged packing. 1.2. Physical data Bonding Chemistry: C30 alkyl Silica Substrate: Spherical, high-purity Particle size 3, 5 µm Surface area 200 m 2 /g Pore size 200 Å 1.3. Specifications and Operational Parameters ph range: ph 2 8 Temperature (max): 60 C Solvent compatibility: 0 to 100% Aqueous compatibility: 0 to 100% Pressure rating: See Table 1 Flow rate: See Table 1 Column Dimension Table 1 Operating pressure and flow rate specifications Maximum P/N Pressure (psi) Particle Size Typical Flow Rate (Recommended) (ml/min) Maximum Flow Rate (ml/min) 4.6 x 250mm 5µm 075718 9,000 0.8 1.5 2.0 4.6 x 150mm 5µm 075719 8,000 0.8 1.5 2.0 4.6 x 150mm 3µm 075723 8,000 0.8 1.5 2.0 4.6 x 100mm 3µm 078660 6,000 0.8 1.5 2.0 4.6 x 50mm 3µm 078661 4,000 0.8 1.5 2.0 3.0 x 250mm 3µm 075726 12,000 0.4 0.6 1.0 3.0 x 150mm 3µm 075724 8,500 0.4 0.6 1.0 3.0 x 100mm 3µm 078662 7,000 0.4 0.6 1.0 3.0 x 50mm 3µm 078663 4,500 0.4 0.6 1.0 2.1 x 250mm 3µm 078664 10,000 0.2 0.3 0.5 2.1 x 150mm 3µm 075725 8,500 0.2 0.3 0.5 2.1 x 100mm 3µm 078665 6,000 0.2 0.3 0.5 2.1 x 50mm 3µm 078666 4,500 0.2 0.3 0.5

Product Manual for Acclaim C30 Columns Page 4 of 16 1.4. Operational Guidelines The direction of flow is marked on the column. While it is not harmful to the column, reverse flow should be avoided except to attempt removal of inlet blockage (see Column Care ). A new column is shipped in a solution of 70% acetonitrile and 30% D.I. water. Initially, care should be taken to avoid any mobile phase that might cause a precipitate. Acclaim C30 columns are compatible with up to 100% aqueous and all common organic solvents. The use of a guard column is recommended to protect the analytical column and extend its useful lifetime. Avoid use of this column below ph 2 or above ph 8. Recommended operating pressures are column format dependent (see Table 1 for details). Maximum operation temperature is 60 C. Columns should be stored in 100% acetonitrile for long-term storage. For short-term storage, avoid exposing the column to harsh conditions, such as ph < 3, ph > 6 or elevated temperature (> 40 C). 1.5. Ordering Information Analytical Particle Size 5µm 3µm Guard 5µm Column Dimensions P/N 4.6 x 250 mm 075718 4.6 x 150 mm 075719 4.6 x 150 mm 075723 3.0 x 250 mm 075726 3.0 x 150 mm 075724 4.6 x 100 mm 078660 4.6 x 50 mm 078661 3.0 x 100 mm 078662 3.0 x 50 mm 078663 2.1 x 250 mm 078664 2.1 x 100 mm 078665 2.1 x 50 mm 078666 2.1 x 150 mm 075725 Required Holder 4.6 x 10 mm 075720 P/N 069580 3.0 x 10 mm 075721 P/N 069580 2.1 x 10 mm 075722 P/N 069580

Product Manual for Acclaim C30 Columns Page 5 of 16 SECTION 2 STEP-BY-STEP USER GUIDE Dionex recommends that you test on your Acclaim C30 column upon receiving it, to ensure no damage has occurred during shipping. Steps 1 5 below outline the necessary steps. Test the column using the conditions described on the Quality Assurance (QA) Report enclosed in the column box. Repeat the test periodically to track the column performance over time. Slight variations may be obtained on two different HPLC systems due to system electronic, plumbing, operating environment, reagent quality, column conditioning, and operator technique. Step 1 Visually inspect the column Report any visual damage to Dionex Corporation. Step 2 Mobile phase preparation Obtaining reliable, consistent and accurate results require mobile phases that are free of ionic and spectrophotometric impurities. Chemicals, solvents and de-ionized water used to prepare mobile phase should be of the highest purity available. Maintaining low trace impurities and low particle levels in mobile phases helps to protect your columns and system components. Dionex cannot guarantee proper column performance when the quality of the chemicals, solvents and water used to prepare the mobile phase has been compromised. Depending on specific application, the mobile phase system consists of an organic solvent (e.g. usually acetonitrile) and an aqueous portion (e.g. D.I. water, ammonium acetate or phosphate buffer). Both pre-mixed and proportioning valve generated mobile phases give satisfactory results. The use of proportioning valve provides better flexibility in method optimization, while the pre-mixed mobile phase provides more reproducible results. Solvents The solvents used must be free from ionic and UV-absorbing impurities. Use of ultrahigh purity solvents, HPLC grade, will usually ensure that your chromatography is not affected by impurities in the solvent. De-ionized Water The de-ionized water used to prepare the mobile phase should be Type 1 Reagent Grade water or HPLC Grade water. The deionized water should be free of ionized impurities, organics, microorganisms and particulate matter larger than 0.2 µm. Many commercial water purifiers are designed for HPLC applications and are suitable for these applications.! NOTE Degas the aqueous component of the mobile phase and then add the solvent component. Avoid excessive purging or degassing of mobile phases containing solvents, if possible, since the volatile solvent can be boiled off from the solution. Mobile Phase for Column Performance Test (QA test): Mobile phase can be generated either by pre-mixing or by using a proportioning valve; both give satisfactory results. The use of a proportioning valve provides better flexibility in method optimization, while the pre-mixed mobile phase provides less baseline noise. Step 3 Set up the LC system Use a standard LC system equipped with a LC pump, a column oven, a UV detector (or an ELS detector depending on the application), and an injector (or an autosampler). The system should be thoroughly primed before use. Step 4 Condition the column Each new column is shipped in the mobile phase used for column performance test (containing 70% acetonitrile). Before use, the column should be washed thoroughly with the mobile phase (~20 column volumes depending on the aqueous content in the mobile phase) before any injection is made.

Product Manual for Acclaim C30 Columns Page 6 of 16 When switching to a different mobile phase, make sure that the new mobile phase is compatible with the existing mobile phase to avoid column clogging due to precipitation. A good practice is to purge the column with 50% acetonitrile in D.I. water (v/v) for approximately 10 column volumes before switching to a new mobile phase. Step 5 Reproduce the chromatogram in the Quality Assurance Report Perform the column QA test using the conditions described in the Quality Assurance Report (QAR), and compare the result with the reported values. The column should be fully equilibrated before any injection. At least three injections should be made until reproducible results are obtained.! NOTE Due to various reasons, such as: difference of LC systems, mobile phases, oven temperature control, etc, you may observe somewhat different separation from that in the report. Actual QC test and performance of your column is described in the Column Performance Report enclosed with your column. Step 6 Real sample analysis Once you are satisfied with the column performance report result, the column is ready for real applications.

Product Manual for Acclaim C30 Columns Page 7 of 16 SECTION 3 COLUMN CARE The inlet and outlet frits on these columns have a nominal porosity of 0.5µm. Particulates in the sample or the mobile phase larger than 0.5µm will plug the column inlet frit. If solvent flow appears to be restricted (high column back-pressure), check first to see that solvent flow is unobstructed up to the column inlet. If the column has the restriction, there may be particulate matter on the inlet frit. An attempt should be made to remove any inlet debris by back-flushing 25 to 30 ml of mobile phase through the column. If this fails to return the column to its original operating pressure, consider replacing the column. To remove strongly retained materials from the column, flush the column with stronger (less polar) solvents. Solvents such as methanol, acetonitrile, or a 95% / 5% mixture of dichloromethane and methanol should remove most highly retained compounds. When switching between solvents with vastly different polarities, it may be necessary to first purge the column with mutually miscible solvent, such as isopropanol. Long-term storage of a silica-based, bonded-phase column should be in a pure organic solvent; preferably an aprotic one such as 100% acetonitrile. If the column has been previously used with a buffered mobile, the buffer should first be removed by purging the column with 20 30 column volumes of a 50/50 mixture of methanol or acetonitrile and water, followed by 20-30 column volumes of the pure solvent. Before storing the column, the end-fittings should be tightly capped with end-plugs to prevent the packing from drying out. The column may be safely stored for short periods in most mobile phases. However, to protect equipment, it is desirable to remove salts from the instrument and column by purging the column with the same organic solvent/water ratio without the buffer. For example, using 60/40 acetonitrile/water to remove 60/40 acetonitrile/0.02 M phosphate buffered mobile phase. Re-equilibration is rapid with the original mobile phase when using this approach, and any danger of corrosion from the salts is eliminated.

Product Manual for Acclaim C30 Columns Page 8 of 16 SECTION 4 APPLICATIONS The Acclaim C30 is a reversed-phase HPLC column. Like other reversed-phase columns, such as C18, this column is useful in a wide range of separations including food & beverage, chemical, environmental, pharmaceutical, academia, etc. Unlike other general-purpose reversed-phase columns, the Acclaim C30 has several unique features. First, it exhibits higher shape selectivity suited to separation of structural isomers. Second, it is fully compatible with various aqueous buffers, resulting in a broader application range and more flexibility in method development. Therefore, the Acclaim C30 can serve as an ideal candidate to complement general-purpose C18 columns in a variety of applications. The following figures are example applications demonstrating the capability of this column. 4.1. Shape Selectivity SRM 869a is useful for characterizing liquid chromatographic (LC) column selectivity for separation of PAHs. This Standard Reference Material (SRM) is a mixture of three polycyclic aromatic hydrocarbons (PAHs) in acetonitrile: benzo[a]pyrene (BaP), 1,2:3,4:5,6:7,8-tetrabenzonaphthalene (TBN, alternate name, dibenzo[g,p]chrysene), and phenanthro[3,4- c]phenanthrene (PhPh). Depending on the elution order of the three components, column selectivity can be predicted for complex PAH mixtures (particularly isomeric PAHs). Note that a smaller α (TBN/BaP) (= k TBN /k BaP ) value indicates higher shape selectivity. As show in Figure 1, the Acclaim C30 column exhibits the highest shape selectivity among other Acclaim reversed-phase columns (Note: lower α(tbn/bap) suggests higher shape selectivity) Column: 4.6 x 150 mm Mobile Phase: CH 3 CN/H 2 O v/v 85/15 Temperature: 25 C Flow Rate: 2 ml/min Inj. Volume: 5 µl Detection: UV (254 nm) Sample: NIST SRM 869a standard mix 1. Benzo[a]pyrene (BaP) 3.0 Shape Selectivity Comparison 2.5 2. Phenanthro[3,4-c]phenanthrene (PhPh) α (TBN/BaP) 2.0 1.5 1.0 2.10 1.79 1.94 1.85 0.5 0.99 3. Dibenzo[g,p]chrysene (TBN) 0.0 Acclaim C30 Acclaim 120 C18 Acclaim PA Acclaim PA2 Acclaim Phenyl 1 Column Name α ( TBN/BaP) = k TBN / k BaP Figure 1 Shape Selectivity

Product Manual for Acclaim C30 Columns Page 9 of 16 4.2. Aqueous Compatibility Most reversed-phase columns have high ligand densities, designed to improve the peak shape of basic analytes and stability at extreme phs. However, dense surface coverage of silica particles with hydrocarbon chains often results in inconsistent retention times in 100% aqueous conditions, also called de-wetting or phase collapse. Although the low ligand density bonding is used to achieve better compatibility with 100% aqueous mobile phases, these phases provide poor peak shapes for bases and lower hydrolytic stability. Because of the intelligent phase design and unique bonding process, Acclaim C30 column overcomes aforementioned difficulties and provides high surface coverage as well as 100% aqueous compatibility (shown Figure 2) no loss of retention was observed after 50 stop-flow cycles. Column: Acclaim C30, 5 µm Dimensions: 4.6 x 150 mm Mobile Phase: 25 mm Ammonium acetate, ph 5.0 Temperature: 30 C Flow Rate: 1 ml/min Inj. Volume: 5 µl Detection: UV (254 nm) Sample: 0.1 mg/ml Probe: Thymine Stop-Flow Protocol: 1. Test the column under above condition 2. Stop the pump for 5 min (pump pressure drops to 0) 3. Resume the flow and condition the column under above condition for 10 min 4. Inject the sample and run the test under the same conditions. 5. Repeat 2 through 4 12.0 De wetting Test 10.0 Retnetion of Thymine (min) 8.0 6.0 4.0 2.0 0.0 0 10 20 30 40 50 Number of Stop Flow Cycle Figure 2 Aqueous Compatibility

Product Manual for Acclaim C30 Columns Page 10 of 16 4.3. Analysis of Carotenoids Carotenoids are naturally occurring in the chloroplasts and chromoplasts of plants, and some fungi and bacteria. They serve two key roles in plants and algae absorb light energy for use in photosynthesis, and protect chlorophyll from photo damage. In humans, four carotenoids (β-carotene, α-carotene, γ-carotene, and β-cryptoxanthin) have vitamin A activity, and can also act as antioxidants. In the eye, certain other carotenoids (lutein and zeaxanthin) apparently act directly to absorb damaging blue and near-ultraviolet light, in order to protect the macula lutea. As shown in Figure 3, six common carotenoids and chlorophyll are separated on the Acclaim C30 column with excellent selectivity and resolution. Column: Acclaim C30, 5 µm Dimensions: 4.6 x 150 mm LC System: UltiMate 3000 RS Mobile Phases: A) Acetonitrile B) Methanol:Ethyl acetate 1:1 (v/v) C) 200 mm Acetic acid in water Gradient: Min -5 0 2 15 25 %A 85.0 85.0 85.0 65.0 65.0 %B 14.5 14.5 14.5 34.5 34.5 %C 0.5 0.5 0.5 0.5 0.5 Flow: 1.50 ml/min Temperature: 30 C Injection: 8 µl Detector: Diode Array; VIS 450 nm, spectra 260 800 nm Samples: A. Carrot extract in acetone B. Spinach extract in acetone C. Maize extract in acetone Peaks: 1. Lutein 2. Zeaxanthin 3. Chlorophyll-b 4. α-cryptoxanthin 5. β-cryptoxanthin 6. Chlorophyll-a 7. α-carotene 8. β-carotene Reference: HarvetsPlus Handbook for Carotenoid Analysis, D.B. Rodriguez-Amaya and M. Kimura, International Food Policy Research Institute, 2004. 80 mau A 276.3 452.4 476.6 260 nm 600 800 3 6 7 8 B 0 C 2 1 4 5 0 5 10 15 20 25 Minutes Figure 3 Carotenoids in Vegetables

Product Manual for Acclaim C30 Columns Page 11 of 16 4.4. Analysis of Glucocorticosteriods Glucocorticosteroids are a group of naturally occurring and synthetic hormones that moderate inflammation and other stress responses. Glucocorticosteroids are on the World Anti-Doping Agency's list of substances prohibited in-competition. Separation of these substances is challenging due to their structural similarity. The method of McWhinney is commonly used in clinical laboratories for monitoring of these substances. While the original method uses a C18 column, the Acclaim C30 offers improved resolution and throughput with same elution order used the literature method. Figure 4 shows a baseline separation of eight glucocorticosteroids using an Acclaim C30 column. Column: Acclaim C30, 3 µm Dimensions: 3.0 x 150 mm LC System: UltiMate 3000 RS Mobile Phase: Methanol:tetrahydrofuran:water 3:25:72(v/v) Flow: 0.50 ml/min Temperature: 30 C Injection: 2 µl Detector: Diode Array; UV 240 nm 100 mau 1 2 Peaks: µg/ml 1. Prednisone 50 2. Cortisone 3. Prednisolone 4. Hydrocortisone 5. Dexamethasone 6. 6-Methylprednisolone 7. Corticosterone 8. 11-Deoxyhydrocortisone 3 4 5 6 7 8 Reference: McWhinney B C, Ward G, Hickman P E; Clin. Chem, 1996, 42:979-981. 0 0 2 4 6 8 10 12 Minutes Figure 4 Glucocorticosteroids

Product Manual for Acclaim C30 Columns Page 12 of 16 4.5. Analysis of Water-soluble Vitamins Water-soluble vitamins are essential nutrients. They are found naturally in food, added to food, or formulated in supplements. Chemically they are a heterogeneous group of anions, cations, zwitterions and neutrals. Due to the variety and complexity of matrices where vitamins are found, the analysis is often challenging. The Acclaim C30 column has desirable combination of high hydrophobic retention and aqueous compatibility, which enables a simple reversed-phase separation of these difficult analytes (Figure 5). Column: Acclaim C30, 5 µm Dimensions: 4.6 x 150 mm LC System: UltiMate 3000 RS Mobile Phases: A) Acetonitrile B) 7 mm Phosphoric acid + 40 mm sodium sulfate (ph 2.65) Gradient times (min): -3.0 0.0 2.0 10.0 12.0 %A 0 0 0 25 25 %B 100 100 100 75 75 Flow Rate: 1.50 ml/min Temperature: 30 C Injection: 10 µl Detector: Diode Array; UV 210 nm, spectra 260 400 nm Samples: Vitamin standards in mobile phase 160 mau 4 Folic acid Peaks: µg/ml 1. Thiamine 25 2. Ascorbic acid 62 3. Niacinamide 25 4. Pyridoxine 25 5. Pantothenic acid 25 6. Folic acid 6.2 7. Riboflavin 5.0 2 3 283.6 nm 200 300 400 6 1 5 7 0 0 5 10 12 Minutes Figure 5 Water-Soluble Vitamins

Product Manual for Acclaim C30 Columns Page 13 of 16 4.6. Analysis of Triglycerides in Cooking Oils Cooking oils are purified lipids from plants, and are usually liquid at room temperature. They contain triglycerides as major components, and small quantity of free fatty acids, mono- and di-glycerides. The composition of cooking oils is highly complex due to the wide variety of alkyl chain length, degree of unsaturation, origin, etc. While normal phase chromatography is often used to characterize oils by their hydrophilicity, reversed-phase chromatography provides high resolution for analyzing minor components, major components, and obtaining more detailed fingerprint. Because of its high shape selectivity, the Acclaim C30 provides higher resolution than the C18 column for oil analysis (Figure 1). Separations of several cooking oils are illustrated in Figure 6 and 7. Column: Acclaim C30 or Acclaim 120 C18, 5 µm Dimension: 4.6 x 150 mm Mobile Phase: Acetonitrile (MeCN)/Iso-propanol (IPA)/ Ammonium Acetate (0.1 M, ph 5.0) (Buffer) Temperature: 40 C Flow Rate: 1.0 ml/min Inj. Volume: 2 µl Detection: Corona ultra (Gain = 100 pa; Filter = medium; Nebulizer. Temp. = 25 C) Sample: Peanut oil (5 mg/ml in iso-propanol) Time (min) MeCN IPA Buffer -15 90 5 5 0 90 5 5 0.1 90 5 5 60 0 95 5 70 0 95 5 150 Acclaim 120 C18 pa Acclaim C30 0 30 38 46 54 62 70 Minutes Figure 6 Analysis of Cooking Oil: C30 vs. C18

Product Manual for Acclaim C30 Columns Page 14 of 16 4.7. Analysis of Cooking Oils Column: Acclaim C30, 5 µm Dimension: 4.6 x 150 mm Mobile Phase: Acetonitrile (MeCN)/Iso-propanol (IPA)/ Ammonium Acetate (0.1 M, ph 5.0) (Buffer) Temperature: 40 C Flow Rate: 1.0 ml/min Inj. Volume: 2 µl Detection: Corona ultra (Gain = 100 pa; Filter = medium; Nebulizer Temp. = 25 C) Sample: Peanut, Olive, or Wheat Germ Oil (5 mg/ml in iso-propanol) 200 Time (min) MeCN IPA Buffer -15 90 5 5 0 90 5 5 0.1 90 5 5 60 0 95 5 80 0 95 5 Wheat germ oil pa Olive oil 0 Peanut oil 0 16 32 48 72 80 Minutes Figure 7 Analysis of Cooking Oils

Product Manual for Acclaim C30 Columns Page 15 of 16 4.8. Phospholipids in Egg Lecithin Phospholipids are a class of lipids and are a major component of all cell membranes as they can form lipid bilayers. Most phospholipids contain a diglyceride, a phosphate group connected a hydrophilic organic group such as choline. The first phospholipid identified in biological tissues was lecithin in egg yolk. Analysis of phospholipids is challenging due to its complexity (hydrocarbon length, degree of saturation of diglyceride moiety, and the type of the hydrophilic organic group connecting to the phosphate). Figure 8 shows the profile of commercial grades of lecithin from egg yolk and soybean obtained on an Acclaim C30 column using a Corona ultra CAD detector. It indicates that lecithin from egg yolk contains both phospholipids and triglycerides, with minor impurities. To obtain detailed information on phospholipids composition, a higher resolution method can be used for is used (Figure 9). Column: Acclaim C30, 5 µm Dimension: 4.6 x 150 mm Mobile Phase: Acetonitrile (MeCN)/Iso-propanol (IPA)/ Ammonium Acetate (0.1 M, ph 5.0) (Buffer) Temperature: 40 C Flow Rate: 1.0 ml/min Inj. Volume: 2 µl Detection: Corona ultra (Gain = 100 pa; Filter = medium; Nebulizer Temp = 25 C) Sample: Egg Lecithin PL30S (5 mg/ml in iso-propanol) Time (min) MeCN IPA Buffer -15 70 0 30 0 70 0 30 0.1 70 0 30 10 90 0 10 35 10 80 10 50 0 95 5 60 0 95 5 60 Phospholipids Triglycerides pa Degradants 0 0 12 24 36 48 60 Minutes Figure 8 Profile of Egg Lecithin

Product Manual for Acclaim C30 Columns Page 16 of 16 4.9. Phospholipids in Egg Lecithin Column: Acclaim C30, 5 µm Dimension: 4.6 x 150 mm Mobile Phase: Acetonitrile (MeCN)/Iso-propanol (IPA)/ Ammonium Acetate (0.1 M, ph 5.0) (Buffer) Temperature: 40 C Flow Rate: 1.0 ml/min Inj. Volume: 5 µl Detection: Corona ultra (Gain = 100 pa; Filter = medium; Nebulizer. Temp. = 25 C) Sample: Egg Lecithin PL100M (5 mg/ml in iso-propanol) 50 Time (min) MeCN IPA Buffer -15 60 20 20 0 60 20 20 0.1 60 20 20 150 38 50 12 151 5 90 5 160 5 90 5 Degradants Phospholipids pa 0 0 30 60 90 120 150 Minutes Figure 9 Phospholipids in Egg Lecithin