Best Practice Protocols

Similar documents
Fitting Frequency Compression Hearing Aids to Kids: The Basics

Candidacy and Verification of Oticon Speech Rescue TM technology

Best practice protocol

Audibility, discrimination and hearing comfort at a new level: SoundRecover2

SoundRecover2: Description and Verification Protocols

Baker, A., M.Cl.Sc (AUD) Candidate University of Western Ontario: School of Communication Sciences and Disorders

Support. Studies of bandwidth: Some Types of evidence to consider: Studies of bandwidth: Stelmachowicz et al 2004

Best practices in A few favorite resources: Clear areas of agreement: How about these features? The bottom line:

FREQUENCY LOWERING IN THE PEDIATRIC POPULATION: OUTCOMES AND CONSIDERATIONS FOR FITTING. Capstone. Lauren Virginia Ross, B.A.

A comparison of manufacturer-specific prescriptive procedures for infants

The University of Western Ontario Plurals Test v1.4

SoundRecover2 the first adaptive frequency compression algorithm More audibility of high frequency sounds

SoundRecover2 More audibility of high-frequency sounds for adults with severe to profound hearing loss

Research Design: This study consisted of a within-participant design with repeated measures across test conditions.

Validation Studies. How well does this work??? Speech perception (e.g., Erber & Witt 1977) Early Development... History of the DSL Method

The Situational Hearing Aid Response Profile (SHARP), version 7 BOYS TOWN NATIONAL RESEARCH HOSPITAL. 555 N. 30th St. Omaha, Nebraska 68131

Chapter 3 NON-LINEAR FREQUENCY COMPRESSION IN HEARING AIDS

2/16/2012. Fitting Current Amplification Technology on Infants and Children. Preselection Issues & Procedures

AJA. Research Article

FREQUENCY COMPOSITION : A NEW APPROACH TO FREQUENCY- LOWERING

AJA. Research Article. Effects of Low-Pass Filtering on the Perception of Word-Final Plurality Markers in Children and Adults With Normal Hearing

Critical Review: Based on its effect on speech and phoneme recognition in children, should frequency lowering be used in pediatric amplification?

Phonak Target. SoundRecover2 adult fitting guide. Content. The Connecting the hearing instruments. February 2018

Hello Old Friend the use of frequency specific speech phonemes in cortical and behavioural testing of infants

Clinical fitting guide

The Devil is in the Fitting Details. What they share in common 8/23/2012 NAL NL2

Paediatric Amplification

AURICAL Plus with DSL v. 5.0b Quick Guide. Doc no /04

DSL v5 in Connexx 7 Mikael Menard, Ph.D., Philippe Lantin Sivantos, 2015.

Audiogram+: The ReSound Proprietary Fitting Algorithm

Verification of soft speech amplification in hearing aid fitting: A comparison of methods

Slow compression for people with severe to profound hearing loss

Supplementary Online Content

Monitoring Outcomes of Infants and Children Who Wear Hearing Aids. Marlene P. Bagatto, Au.D., Ph.D. Danielle Glista, Ph.D. Susan D. Scollie, Ph.D.

Audiogram+: GN Resound proprietary fitting rule

ELECTROACOUSTIC EVALUATION OF THE RESOUND UNITE MINI MICROPHONE WITH OTOMETRICS AURICAL HIT

Issues faced by people with a Sensorineural Hearing Loss

International Journal of Health Sciences and Research ISSN:

C HAPTER FOUR. Audiometric Configurations in Children. Andrea L. Pittman. Introduction. Methods

Phonak Target 6.0. Phonak Target Fitting Guide. Content. November 2018

Interpreting Speech Results to Optimise Hearing aid Fittings

Evidence base for hearing aid features:

Marlene Bagatto & Anne Marie Tharpe. A Sound Foundation Through Early Amplification Conference Chicago, USA December 10, 2013

Phonak Target 5.4. Phonak Target Fitting Guide. Content. August 2018

Sonic Spotlight. Frequency Transfer Providing Audibility For High-Frequency Losses

The Influence of Audibility on Speech Recognition With Nonlinear Frequency Compression for Children and Adults With Hearing Loss

Marlene Bagatto The University of Western Ontario, London, Canada. European Pediatric Amplification Conference Istanbul, Turkey November 15, 2011

The Desired Sensation Level (DSL) method has had

Audiology Today MarApr2011

Frequency refers to how often something happens. Period refers to the time it takes something to happen.

Examining Recommendations for Hearing Aid Use In Children with Unilateral Hearing Loss

Phonak Target 4.3. Desktop Fitting Guide. Content. March 2016

Potential Mechanisms for Perception of Frequency-Lowered Speech

Phoneme Perception Test 3.0

Comparing Speech Perception Abilities of Children with Cochlear Implants and Digital Hearing Aids

Building Practice Success Through Speechmap Real Ear Measurements. Chris Stokes-Rees

HCS 7367 Speech Perception

Although considerable work has been conducted on the speech

For most hearing losses, the primary goal of amplification is to provide

Desktop Fitting Guide for Phonak Brio 3

The effect of nonlinear frequency compression and linear frequency transposition on speech perception in school-aged children

Verifying the Lyric Audibility Advantage

Frequency-Lowering Devices for Managing High-Frequency Hearing Loss: A Review

EEL 6586, Project - Hearing Aids algorithms

Sonic Spotlight. SmartCompress. Advancing compression technology into the future

ASR. ISSN / Audiol Speech Res 2017;13(3): / RESEARCH PAPER

ChildFit. Widex Baby. Compass quick guide

Acoustics, signals & systems for audiology. Psychoacoustics of hearing impairment

ELECTROACOUSTIC EVALUATION OF THE RESOUND MULTI MIC WITH OTOMETRICS AURICAL HIT

FREQUENCY COMPRESSION AND FREQUENCY SHIFTING FOR THE HEARING IMPAIRED

Using digital hearing aids to visualize real-life effects of signal processing

Speech Cue Weighting in Fricative Consonant Perception in Hearing Impaired Children

Quick Guide Binaural REM

Fitting Decisions and their Impact on Hearing Aid User Benefit. Mallory Maine, AuD Audiologist, GN ReSound

Working Together: The Information Exchange Between Families, Pediatric Audiologists and Early Interventionists to Maximize Outcomes

Digital noise reduction in hearing aids and its acoustic effect on consonants /s/ and /z/

Anumber of studies have shown that the perception of speech develops. by Normal-Hearing and Hearing- Impaired Children and Adults

Manufacturers NAL-NL2 Fittings Fail Real-ear Verification

A Sound Foundation Through Early Amplification

Guidance on Identifying Non-Routine Cases of Hearing Loss

2.0. Desktop Fitting Guide getting started. Preparation of the hearing instruments

The effect of talker age and gender on speech perception of pediatric hearing aid users

AccuQuest Spotlight: Successful Fittings with Oasis. Fitting Range

From /I/ to /fis/ Terminology. How do frequency compressing hearing aids differ from conventional-style digital aids?

Top 10 ideer til en god høreapparat tilpasning. Astrid Haastrup, Audiologist GN ReSound

Pho. nak. Desktop. August with Phonak. Target. Fitting

Bimodal Devices on Children: A Survey of Clinician Fitting Practices in North America

Effects of Setting Thresholds for the MED- EL Cochlear Implant System in Children

Lyric3 Programming Features

Clinical Tips for Matching Real-Ear Prescriptive Targets

Testing Digital Hearing Aids

Beltone Electronics 2601 Patriot Boulevard Glenview, IL U.S.A. (800)

Walkthrough

WIDEXPRESS. no.30. Background

Chapter 7 CONCLUSION AND RECOMMENDATIONS

Optimising Outcomes for Speech Mapping

1706 J. Acoust. Soc. Am. 113 (3), March /2003/113(3)/1706/12/$ Acoustical Society of America

Prescribe hearing aids to:

Amigo Star. Insert photos matching the introduction paragraph of the literature review

Transcription:

Best Practice Protocols SoundRecover for children What is SoundRecover? SoundRecover (non-linear frequency compression) seeks to give greater audibility of high-frequency everyday sounds by compressing sounds that a child is unable to hear to a lower frequency region where a child can hear better. SoundRecover compresses the signal above a specified cutoff frequency. The degree of compression applied to this high-frequency band is defined by the compression ratio. The spectrum below the cut-off frequency remains unchanged to avoid vowel artifacts. 1,7 When fitting SoundRecover to children using DSL v5, a different pre-calculation is used compared to adults. These default settings for SoundRecover for pediatric fittings are based on research from the University of Western Ontario and are implemented in Phonak Target fitting software. Why perform verification? As with all pediatric fittings, it is important to measure the output of hearing instruments with SoundRecover to check that prescriptive targets are met and the child has access to important speech cues. The aim of this report is to provide current best-practice guidance for verifying the electroacoustic characteristics with SoundRecover on and off. How to verify SoundRecover? The following clinical protocol for verifying hearing aids with frequency lowering technology such as SoundRecover is designed to assist clinicians with optimizing hearing aid settings. 3 For current best practice, both live voice and calibrated signals are acceptable. However, functionality and availability of stimuli varies among the different verification devices. Below is a step-by-step general protocol that can be used across devices to verify SoundRecover. This general protocol has been applied in several studies of SoundRecover in the pediatric population. 1,2,5,7 1. Disable SoundRecover in the hearing aids within the fitting software. 2. Evaluate the shape and gain of the hearing aid fitting using speech stimuli with SoundRecover disabled. a. Ensure that the aided speech spectra meet prescriptive targets as broad a bandwidth of audibility as possible. If necessary, adjust the output response to optimize the fitting. b. MPO measurements are not valid in the frequencylowered region. Therefore, always measure MPO with SoundRecover disabled.

3. Enable SoundRecover. Choose moderate-level stimuli (i.e. live voice and/or calibrated signals) that represent /s/ and /sh/ sounds respectively. a. Fine-tune the hearing aid settings to optimize audibility of these sounds within the child s audible range. It is important to note that audibility of /s/ is not always possible depending upon the extent and configuration of hearing loss. b. Use the weakest SoundRecover setting that provides audibility when possible and check for separation of /s/ and /sh/. 4. Perform a listening check prior to completing a fitting with SoundRecover. Due to some fittings having high output levels, it may be helpful to listen to the output of the hearing aids via the test box. For example, headphones can be plugged into some test boxes allowing the ability to adjust the volume and to listen to the aided responses during verification. If you cannot detect any difference between aided /s/ and /sh/, consider the spectral overlap of these sounds, and the possibility of a weaker SoundRecover setting. 5. Perform other measurements as needed for troubleshooting or further fine tuning. a. If /s/ or /sh/ is not audible, repeated measurements with additional fine tuning to the hearing aid may assist in discovering a setting that provides more audibility. b. If subjective feedback indicates /s/ and /sh/ confusion, a setting that provides less frequency compression while maintaining audibility for high-frequency sounds may be needed. c. Live voice productions of /s/ and /sh/ can provide an estimate of audibility and frequency band perception. However, live voice signals do not give a calibrated method for estimating audibility. Therefore, there are different calibrated test signals which can be used to represent /s/ and /sh/ across verification systems. For system-specific background knowledge and troubleshooting, please refer to the documents: Electroacoustic verification of SoundRecover using the Audioscan Verifit or Electroacoustic verification of SoundRecover using the GN Otometrics AURICAL located in the pediatric web tool box via the following link: https://www.phonakpro.com/us/b2b/en/pediatric/ pediatric_fitting/pediatric-web-tool-box.html 6. Provide post fitting support. a. Provide information and guidance for caregivers, therapists or anyone else who may do a listening check on the hearing aids. It is important to recognize the sound quality will differ from conventional hearing aids. One approach is to alert caregivers or therapists that sound quality may differ from previous hearing aids, and that listening checks should focus on changes from baseline rather than on whether sound quality is similar to the child s previous hearing aids. Hearing care professionals need to incorporate feedback from therapists and family on the perception of highfrequency sounds (i.e. /s/) in the child s program to support discrimination skills, word recognition and therefore, language development. It is helpful to include the child s production of the different speech sounds (e.g. /s/, /f/, /sh/, etc) to optimize auditory discrimination skills. Note: Some fitting cases can provide additional challenges and may include factors such as tinnitus masking, dead regions, and auditory neuropathy. Feel free to request fitting support if needed from your local Phonak representative. Available stimuli for verifying SoundRecover Live voice productions Live voice is an option which is available across various verification devices. This allows for the estimation of the audibility and evaluating the true bandwidth of phonemes such as /s/ and /sh/. Live voice has the following advantages: a. Some sounds such as /sh/ can be several octaves wide. Live voice is beneficial for looking at the entire frication bandwidth. This may be helpful for estimating how much of that sound is audible across a wider frequency 2 Best Practice Protocols

range. In cases of steeply sloping, severe to profound high frequency hearing loss, the audibility of /s/ or /sh/ may be limited to only the lower shoulder of the frication band. In such cases, this information can prove to be helpful for estimating audibility and whether fine tuning can provide additional benefit. b. Because live speech sounds reflect true bandwidth, they are well suited for evaluation of frequency overlap between /s/ and /sh/. For example, if confusion between /s/ and /sh/ is a concern (i.e. feedback from the Speech and Language Pathologist or Auditory Verbal Therapist or the individual using this technology), measuring these phonemes carefully may help in evaluating if too much frequency compression has been applied. Live voice has the following possible limitations: a. Live voice is not presented at a calibrated level and talker gender differences will impact responses. Take caution to present speech sounds with normal vocal effort which can be monitored via a sound level meter in some verification systems and at a normal distance and azimuth to the hearing aid microphone(s). This test should be done in a quiet room. b. Male and female talkers will produce /s/ at different frequencies. A male /s/ is typically about 5-6 khz while female /s/ is 7 khz or higher. 3,4 Filtered speech with high-frequency bands of energy Calibrated filtered speech test signals have energy surrounding the specific 1/3 octave band and have been notched out to provide better visualization of the speech band. Test stimuli with the following center frequencies can be selected by the clinician: 3150, 4000, 5000, or 6300 Hz. These speech bands have the following advantages: a. They are presented at a calibrated level. b. The test is repeatable both in intensity level and frequency. c. The speech bands at 4000 Hz and 6300 Hz provide a reasonable estimate of the center frequency for /sh/ and /s/, respectively. These signals have the following possible limitations: a. The 1/3 octave band filtered signals are narrower than the frication band of naturally produced speech sounds (i.e. /sh/ or /s/). This may lead to a conservative estimate of audibility. b. These signals are presented at the level of the Long Term Average Speech Spectrum (LTASS) at that test frequency. This presentation level is slightly lower than the level of /sh/ or /s/ would be in clearly articulated speech. This may lead to a conservative estimate of audibility. c. This test allows evaluation only to 6300 Hz, while a female /s/ is typically higher in frequency. Calibrated Ling 6 /sh/ and /s/ signals The calibrated Ling 6 test stimuli are derived from the Ling 6 (HL) test from the University of Western Ontario, but are presented in SPL and provide the reference for the test. These signals have the following advantages: a. It provides a calibrated set of stimuli spoken by a female speaker. This allows for the estimation of audibility of these phonemes. b. Similar to live voice, these calibrated speech sounds better reflect the true bandwidth of the frication bands and are well suited for evaluation of frequency overlap between /sh/ and /s/. If confusion between /sh/ and /s/ is a concern, measuring these phonemes can help evaluate the settings and determine if too much frequency compression has been applied. These signals have the following possible limitations: a. GN Otometrics recommends that clinicians present the Ling /s/ and /sh/ at an overall level of 65 db SPL. Further evaluation is needed in order to determine the effectiveness of this method. Best Pactice Protocols 3

Case example A: Illustrating the frequency lowering fitting protocol with different commercially available verification devices. The following case illustrates a typical fitting for a child who has high-frequency thresholds in the severe range (figure 1). Figure 3: Live speech SoundRecover off Figure 1: Audiogram A modern hearing aid is fitted without SoundRecover. The hearing aid response begins to roll off above about 5000 to 6000 Hz. Audibility is poorer for the high-frequency energy in soft speech (green) and high-frequency sounds such as a female production of /s/ (figure 2). Figure 4: Live speech SoundRecover on frequency lowered fricatives are non-overlapping, which may support discrimination of /s/ and /sh/ sounds. Figure 2: Hearing aid output responses with SoundRecover off The limitations of high-frequency audibility for speech sounds can be evaluated using the live voice production of /s/ and /sh/. Without frequency lowering, the /s/ sound (green area) is not likely audible for soft speech inputs while /sh/ (purple area) is audible (figure 3). With frequency lowering enabled (figure 4), more of the /sh/ bandwidth is audible and /s/ is now clearly audible and above threshold. The peak frequency area and lower shoulder of the Because this fitting was done using one clinician s voice as the test signal, future follow up should monitor whether functional benefits are also obtained in real life. Another option for verifying this fitting is the use of the filtered speech bands offered by the Audioscan Verifit. Two of the test signals, Speech4000 (green curve) and Speech6300 (purple curve), are shown with and without SoundRecover (figures 5 & 6 respectively). They are filtered to show a 1/3 octave band of speech centered around those frequencies. Details regarding the construction and calibration of these signals are provided in the Verifit user s manual and discussed in Glista and Scollie (2012). 1 The limitations of high-frequency audibility for speech sounds can also be evaluated using the calibrated Ling 6 sounds available in the GN Otometrics AURICAL. They can be found under the FreeFit option. Choose Signal Type and then Ling S or Ling SH along with the intensity level. 4 Best Practice Protocols

Figure 5: Filtered signals with SoundRecover off Figure 7: Ling 6 /s/ and /sh/ with SoundRecover off Figure 6: Filtered signals with SoundRecover on The example in Figure 7 demonstrates limited audibility of /s/ and the shoulder of /sh/ without SoundRecover. However, with SoundRecover enabled (Figure 8), both /s/ and /sh/ are audible, and the fitting shown is likely acceptable for real world use. The peak frequency area and lower shoulder of the frequency lowered fricatives are non-overlapping, which may support discrimination of /s/ and /sh/ sounds. Figure 8: Ling 6 /s/ and /sh/ with SoundRecover on by this example. For this reason, clinicians can choose to select their preferred test/s. However, if there are fitting concerns related to inaudibility or spectral overlap of /s/ and /sh/, then additional testing and fine tuning is recommended. The next example will demonstrate how to potentially manage the concerns of spectral overlap or limited audibility. These examples using stimuli for evaluating frequency lowering available in different verification devices illustrate the same fitting conclusions as with live speech production: 1. The use of SoundRecover is necessary to obtain better audibility for the 6300 Hz speech band representative of /s/ or a calibrated Ling 6 /s/. 2. The output responses are non-overlapping which can support discrimination of /s/ and /sh/ sounds. These test approaches (live speech, speech bands or calibrated Ling 6 fricatives) provide similar results, as shown Best Pactice Protocols 5

Case example B: (This case has been previously published in ENT & Audiology News (2011) 5 Illustrating the role of fine tuning using the Audioscan Verifit This child (John) was seen for fine-tuning of the frequency compression settings in his hearing aids. He has a steeply sloping loss, with severe to profound hearing loss in the high frequencies (figure 9). Figure 11: Live speech with SoundRecover with default settings* Figure 9: Audiogram* Verification measures using the Audioscan Verifit were completed according to the verification protocol discussed earlier in this document. Measurements suggest the default setting (2100 Hz cut-off, 4:1 compression ratio) did not provide sufficient audibility of high-frequency sounds for either speech bands (figure 10) or live speech sounds (figure 11). Figure 12: Filtered signals with stronger SoundRecover setting* The borderline audibility of 3150 and 4000 Hz (purple and blue curves respectively) raises concern that the /sh/ sound might not be audible. In order to evaluate audibility for /sh/, the live speech tests were completed. Results suggest audibility of /sh/ is available across the low-frequency shoulder of the /sh/ frication band as indicated by the purple spectrum (figure 13). The live /s/ sound is clearly not audible. Due to the severity of John s hearing loss and limitations of the hearing aid, audibility of high-frequency sounds beyond 4 khz could not be achieved, likely impacting detection and recognition of /s/ (green area). Figure 10: Filtered signals with SoundRecover with default settings* Verification measures were completed with a revised, stronger SoundRecover setting (1600 Hz cut-off, 4:1 compression ratio). Results for the filtered speech bands test (figure 12) indicate that 6300 Hz (yellow curve) for /s/ is clearly not audible. 6 Best Practice Protocols Behavioral outcome measurements were completed with each hearing aid condition (default setting and the stronger SoundRecover setting). These results (figure 14) provide further information regarding whether fine tuning was effective in this older child. Overall, they suggest that the finetuned setting provided better access to speech sounds than the original setting. This case illustrates the importance of fine tuning to optimize audibility, but also that audibility of all frequencies and speech sounds may not always be possible.

Figure 13: Live speech with stronger SoundRecover setting* Test Percent correct score Setting 1 Percent correct score Setting 2 Interpretation Nonsense syllables 56% 69% Significant improvement with the revised settings Discrimination of s/sh 37% 65% Significant improvement with the revised settings Figure 14: Behavioral outcome measures for nonsense syllables and /s/ and /sh/ discrimination for different SoundRecover settings* Clinical implications when using different stimuli for verifying SoundRecover The 1/3 octave band high-frequency speech band tests appear to be valid electroacoustic stimuli that can quantify the degree and nature of frequency compression. The use of live voice productions of /s/ and /sh/ as a verification option is recommended. 5 In addition, calibrated Ling 6 stimuli can provide a signal that more closely represents the true frication bandwidth of live speech stimuli. The following are important to note: 2. The 6300 Hz speech band provides a good approximation of a naturally produced female /s/ sound. 3. None of the frequency-specific speech bands provide a good approximation of /sh/, because they are narrower in bandwidth than a /sh/ sound. However, the 4000 Hz and 6300 Hz speech band tests can be used in combination to establish audibility of /sh/. 1. The use of live voice productions of /s/ and /sh/ are recommended because of their face validity. However, it is important to be aware of differences in frequency between female and male productions of high frequency sounds. 2 The calibrated Ling 6 stimuli for /s/ and /sh/, reflect more closely the true bandwidth of live voice productions for high frequency phonemes and can be well suited for evaluation of frequency overlap between /s/ and /sh/. Best Pactice Protocols 7

Summary References This document illustrates how various stimuli such as live voice and filtered speech signals can be used for verifying SoundRecover by: 1. Demonstrating whether sounds such as /s/ and /sh/ are audible and the application of SoundRecover may increase audibility of /s/ and sometimes /sh/ depending upon the severity and audiometric configuration. 2. Checking the amount of overlap created from a specific SoundRecover setting. For example, as SoundRecover settings are made stronger, /s/ and /sh/ are subject to a greater amount of overlap. As these sounds become more similar in frequency, (i.e. the bandwidth of /s/ gets smaller with more SoundRecover applied) this creates the potential for sound confusion. This demonstrates procedures for further fine tuning with a weaker setting and repeating all electroacoustic measures. 3. Although overlap is an area of concern requiring detailed evaluation, further research is needed to be able to quantify how much overlap can occur while still maintaining the ability to discriminate between two phoneme patterns (i.e. /s/ and /sh/). *Permission to use images in this document were granted by ENT & Audiology news as well as the authors. 5 1. Glista, D., Scollie, S., & Sulkers, J. (2012). Perceptual Acclimatization Post Nonlinear Frequency Compression Hearing Aid Fitting in Older Children. Journal of Speech, Language, and Hearing Research, 55(6): 1765-87. 2. Glista, D & Scollie S. (2009) Modified Verification Approaches for Frequency Lowering Devices. Available: http://www.audiologyonline.com/articles/modifiedverification-approaches-for-frequency-871 [9 November 2009] 3. Nittrouer, S. (1995). Children learn separate aspects of speech production at different rates: Evidence from spectral moments. Journal of the Acoustical Society of America, 97, 520-530. 4. Pittman, A. L., Stelmachowicz, P. G., Lewis, D. E., & Hoover, B. M. 2003. Spectral characteristics of speech at the ear: implications for amplification in children. Journal of Speech, Language, and Hearing Research,46(3), 649-657. 5. Scollie, S. & Glista, D. (2011). Digital signal processing for access to high frequency sounds: implications for children who use hearing aids. ENT & Audiology News, 20(5): 83-88. 6. Scollie, S., Glista, D., Bagatto, M., Seewald, R. Multichannel nonlinear frequency compression: A new technology for children with hearing loss. In R. Seewald and J. Bamford (eds.), A Sound Foundation through Early Amplification: Proceedings of the fourth international conference 2007, pp. 151-159 Chicago, Illinois: Phonak AG. 7. Wolfe, J., John, A., Schafer, E., Nyffeler, M., Boretzki, M., & Caraway, T. (2010). Evaluation of non-linear frequency compression for school-age children with moderate to moderately-severe hearing loss. Journal of the American Academy of Audiology, 21(10), 618-628. Acknowledgements The content in this document have been provided and is endorsed by the following individuals: - Andrea Bohnert, University Medical Center Johannes-Gutenberg, Mainz, Germany - Dr. Danielle Glista, Child Amplification Laboratory at the University of Western Ontario, Canada - Dr. Josephine Marriage, UCL Ear Institute, United Kingdom - Dr. Susan Scollie, Child Amplification Laboratory at the University of Western Ontario, Canada - Dr. Jace Wolfe, Hearts for Hearing, Oklahoma City, USA 028-0992-02/V1.00/2013-11/rz Printed in xxxx Phonak AG All rights reserved