Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Similar documents
Spatially Fractionated GRID Therapy: A Case Study Abstract: Introduction: Case Description: Conclusion: Key Words Introduction

EORTC Member Facility Questionnaire

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Intensity Modulated RadioTherapy

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Additional Questions for Review 2D & 3D

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

POSTGRADUATE INSTITUTE OF MEDICINE UNIVERSITY OF COLOMBO MP (CLINICAL ONCOLOGY) PART I EXAMINATION - AUGUST Time : p.m p.m.

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

First, how does radiation work?

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

SRS Uncertainty: Linac and CyberKnife Uncertainties

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

Dosisverifikation mit Delta 4 Discover während der Behandlung

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

Work partially supported by VisionRT

Sarcoma and Radiation Therapy. Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington

Leila E. A. Nichol Royal Surrey County Hospital

Ali S. Meigooni, Kai Dou, Navid J. Meigooni, Michael Gnaster, Shahid Awan, Sharifeh Dini, and Ellis L. Johnson

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Small field diode dosimetry

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

IMRT Planning Basics AAMD Student Webinar

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

RTOG DOSIMETRY DATA SUBMISSION

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

Implementation of advanced RT Techniques

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

HALF. Who gets radiotherapy? Who gets radiotherapy? Half of all cancer patients get radiotherapy. By 1899 X rays were being used for cancer therapy

Hybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

Radiotherapy in feline and canine head and neck cancer

Accurate Accurate boost or Simply Accuboost

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Normal tissue dose in pediatric VMAT Piotr Zygmanski

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

Head and Neck Service

Case Study. Institution Farrer Park Hospital

National System for Incident Reporting in Radiation Therapy (NSIR-RT) Taxonomy

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

Chapters from Clinical Oncology

Credentialing for the Use of IGRT in Clinical Trials

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

PGY-1. Resident Review Session Schedule

Overview of MLC-based Linac Radiosurgery

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Radiotherapy Physics and Equipment

Quality assurance program for prototype stereotactic system developed for Neptun 10 PC linac

Diode calibration for dose determination in total body irradiation

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Future Therapeutic Developments in Head and Neck Cancer

Debate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete

Electron therapy Class 3: Clinical procedures

Electron Beam ET - Reloaded Therapy - Reloaded

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy

Intrafractional Junction Shifts Utilizing Multileaf Collimation: A Novel CSI Planning Technique. Rodney Hood RT(R)(T)CMD

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

IMRT QA: Point Dose Measurements or 2D Array?

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

Klinikleitung: Dr. Kessler Dr. Kosfeld Dr. Tassani-Prell Dr. Bessmann. Radiotherapy in feline and canine head and neck cancer.

Limits of Precision and Accuracy of Radiation Delivery Systems

Reducing excess radiation from portal imaging of pediatric brain tumors

Grid Treatment of Left Upper Lobe Lung Mass History of Present Illness: Past Medical History:

Unrivaled, End-to-End

Spinal Cord Doses in Palliative Lung Radiotherapy Schedules

Transcription:

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, 2014 Pamela Myers, Ph.D.

Introduction o o o o o Outline GRID compensator Purpose of SFRT/GRID therapy Fractionation and dose Previously published studies MLC- vs. collimator-based GRID therapy GRID treatment planning o o o CT simulation Beam setup Output measurement/hand calculation GRID treatment delivery o Patient setup/localization Case Examples Conclusion

Intro: GRID Compensator Constructed from a block of brass by.decimal (.decimal Inc., Sanford, FL) Approximately 7.62cm thick and weighs 15.8kg Hole centers are 2.11cm from center to center and 1.43cm in diameter at isocenter

Intro: GRID Compensator Irradiates a maximum field size of 25cmx25cm at isocenter Holes in compensator are made to match the specific divergence of your linear accelerator The GRID comes fixed on a tray that slides into the blocking tray holder on linac

Intro: Purpose Spatially fractionated radiation therapy (SFRT) using a GRID compensator allows treatment to be delivered through small openings Benefits large, bulky tumors that can be limited by normal tissue toxicity Treating only through small openings spares areas of skin under block o High, single fraction dose can be tolerated

Intro: Purpose GRID therapy may benefit patients with bulky tumors (generally > 8cm in diameter) that do not respond to traditional therapy Large, aggressive tumors that may grow during conventional radiation fractionation Patients that have previously undergone chemotherapy or other therapies without response

Intro: Purpose Exact biological response is not fully known Believed that high single GRID dose incites reoxygenation with a high tumor cell kill Reoxygenation can then begin more rapid tumor response and higher efficiency of a traditional external beam fractionation following GRID

Intro: Purpose Bystander effect may also contribute to effectiveness of GRID High direct cell kill Can cause indirect cell kill of nearby cells due to excretion of cytokines upon death of the nearby cells

Intro: Fractionation and Dose GRID SFRT is generally delivered in a single fraction to a dose between 15 to 20Gy o Our clinic prescribes 15Gy to dmax with the patient set up to 100cm SSD Traditional radiotherapy regimen then follows o Total dose/dose per fraction remains the same as if the GRID therapy was not treated o GRID fraction added to beginning of treatment as it is believed that the tumor may not respond to traditional dose/fraction and might even grow to be larger during this treatment regimen

Intro: Previous Studies Mohiuddin et. al. completed a study with a total of 61 GRID patients (1) Site # of Patients Gastrointestinal 18 Sarcomas 12 Genitourinary 9 Gynecologic 9 Melanoma 5 Lung 1 Breast 2 Thyroid 1 SCC- Head and Neck 4 Total 61

Intro: Previous Studies Follow-up ranged from 1-28 months Overall response rate of 91% Overall palliative response in 86% of patients treated with grid and no external beam radiation 92% of patients that received grid and concurrent external beam radiation responded Complete palliative response higher with external beam doses of 40Gy and higher

Intro: Previous Studies Another study by Mohiuddin published in 1999 evaluated toxicity and effectiveness of GRID therapy (2) 71 patients with advanced bulky tumors (> 8cm) treated with GRID o 8 patients treated with GRID as a part of definitive treatment combined with EBRT 50-70Gy followed by surgery o 47 patients treated with GRID and additional radiotherapy o 14 patients treated GRID alone

Intro: Previous Studies For palliative patients o 78% response rate for pain o 72.5% response rate for mass effect o 100% response rate for bleeding For 8 definitive cases o Clinical complete response seen in 5 patients (62.5%) o Pathological complete response in 4 patients (50%) No grade 3 late skin, subcutaneous, mucosal, GI, or CNS complications were observed in any of the 71 patients

Intro: Previous Studies In 2012, Mohiuddin published a GRID study for a large, high-grade extremity sarcoma (3) 82-year-old female Right, rapidly growing upper extremity sarcoma After 10Gy of conventional EBRT, tumor volume continued to increase Emergently treated with GRID to dose of 18Gy to the bulk of the tumor volume After received more EBRT to total of 32Gy for EBRT and 18Gy for GRID

Intro: Previous Studies Tumor growth suspended within 10 days of GRID therapy Surgery performed after radiotherapy 90% tumor regression rate and 99% necrosis rate o 90% with this treatment vs. 0-0.5% radiological regression rate for comparison studies

Intro: Previous Studies (3) Adeel Kaiser, Majid M. Mohiuddin, and Gilchrist L. Jackson. (2012). Dramatic response from neoadjuvant, spatially fractionated GRID radiotherapy (SFGRT) for large, high-grade extremity sarcoma. Journal of Radiation Oncology. doi:10.1007/s13566-012-0064-5

Intro: Previous Studies (3) Adeel Kaiser, Majid M. Mohiuddin, and Gilchrist L. Jackson. (2012). Dramatic response from neoadjuvant, spatially fractionated GRID radiotherapy (SFGRT) for large, high-grade extremity sarcoma. Journal of Radiation Oncology. doi:10.1007/s13566-012-0064-5

Intro: MLC- vs. Compensator-based GRID Multi-leaf collimators (MLC) can also be used to generate a grid pattern of dose delivery o Using MLC-based grid in place of the external GRID compensator requires many more monitor units (MU) o Can increase MU over 500% vs. using a compensator (4) o High amount of MU results in greater leakage through the MLCs and higher surface dose o Areas that mimic blocked portions near holes of field have greater low-dose smearing o Takes a much longer time to complete patient treatment due to higher number of MU

Intro: MLC- vs. Compensator-based GRID GRID compensator MLC-based (4) Buckey, Courtney et al. Evaluation of a commercially-available block for spatially fractionated radiation therapy. Journal of Applied Clinical Medical Physics, [S.l.], v. 11, n. 3, apr. 2010. ISSN 15269914.

GRID Treatment Planning: CT Simulation Strategically angle the patient to obtain maximal tumor exposure while minimizing normal tissues near the tumor if possible For head and neck patients, turning their head before creating a mask can help expose more tumor and help avoid normal tissues For a chest lesion, angling the face away from the tumor

GRID Treatment Planning: CT Simulation

GRID Treatment Planning: Beam Setup A static beam is set up to enter only through the tumor MLCs are used to block normal tissue that may be in the field Often collimator and couch angle rotation are employed to maximize tumor exposure and minimize normal tissues in field

GRID Treatment Planning: Beam Setup All of our GRID patients are prescribed a single fraction dose of 15Gy GRID therapy should be a single fraction from 10-20GY Mohiuddin et. al. (1) showed doses 15Gy achieved a 100% palliative response vs. 79% for <15Gy

GRID Treatment Planning: Beam Setup Beam Isocenter is placed at 100cm SSD o Machine isocenter is located in the center of the middle hole of the GRID compensator Dose is prescribed to dmax for the given energy Our clinic only uses 6MV photons to treat grid patients due to concern for neutron creation and exposure for beam energies above 10MV Using 6MV, we prescribe to a depth of dmax=1.6cm

GRID Treatment Planning: Beam Setup

GRID Treatment Planning: Beam Setup Isodose lines can be used as a visual to view the maximum extent of possible dose o This is for an open static beam conformed to the tumor o Actual beam is delivered as small spears of dose in the grid pattern o Verify that isodose lines are contained within the tumor volume Prescription will be to dmax at 100cm SSD with the beam isocenter located in the center of the center open hole of the GRID

GRID Treatment Planning: Output Measurement Our clinic performs patient-specific output factor measurements The open, static treatment beam is transferred to our record and verify system Solid water phantom located at 100cm SSD with ion chamber inserted at dmax in the center of the center grid hole

GRID Treatment Planning: Output Measurement Gantry is upright with beam direction towards the floor (0 degrees for Elekta machines) and couch is without rotation o The beam should be setup to 100cm SSD at beam center enface with the patient surface so taking the output measurement without the patient-specific gantry/couch angle is adequate Ion chamber measurement is taken for an open 10x10cm 2 field at 100cm SSD and at dmax for the given energy for 100MU Patient-specific, MLC-shaped field is loaded onto the linac GRID is then inserted and another 100MU are delivered

GRID Treatment Planning: Output Measurement Output factor for the patient-specific GRID beam is calculated as follows: o Output Factor = ion chamber measurement with GRID ion chamber measurement with open field In both cases the same amount of MU are delivered, however one measurement is with the GRID and patient-specific beam and one is without for an open beam

GRID Treatment Planning: Hand Calculation Our machine is calibrated to deliver 1cGy/MU at dmax for 100cm SSD therefore the prescription dose in cgy is equivalent to what would be expected for an open 10x10cm 2 beam with the same setup (1500cGy=1500MU) Calculate the patient-specific number of MU needed to deliver prescription with the GRID : o GRID MU needed = prescription dose in cgy or MU equivalent for calibration field GRID output factor o Example: GRID MU needed = 1500 MU 0.894 = 1678 MU

GRID Treatment Planning: Hand Calculation The hand calculation MU is then used for the patient treatment This MU is inserted into the patient-specific beam uploaded into the record and verify system This total MU will be delivered in the single GRID fraction

GRID Treatment Delivery: Patient Setup/Localization Patient setup/localization at our clinic: o Patient is setup as any other patient would be o Apply shifts from simulation isocenter and adjust so that the beam crosshair is located at 100cm SSD o A cone-beam CT is then taken and shifts are applied as necessary o After CBCT alignment, the light field of the treatment beam is visualized on the patient to verify location and beam entry only through tumor o Port films of the treatment field are taken for verification of tumor location related to the field (verify only tumor in field) o GRID is then placed in the field and GRID light field can be visualized on patient for verification o Treatment is then delivered for the GRID fraction

GRID Treatment Delivery: Patient Setup

Case Examples: Case 1 58 year old male Squamous cell carcinoma with unknown primary Non-responsive to chemotherapy Large, protruding neck mass Treated 15Gy for 1 fraction of GRID therapy Followed by 2Gy for 35 fractions for a total of 70Gy

Case Examples: Case 1 CT simulation 4/7/2014 Angled face away from tumor to obtain maximal exposure of tumor for GRID

Case Examples: Case 1 Beam setup showing only tumor allowed in field. MLCs used to block normal tissues and conform beam to tumor volume. Couch and collimator angled to obtain maximum tumor coverage.

Case Examples: Case 1 Exported treatment beam to R&V system Water phantom with ion chamber inserted set up to 100cm SSD with chamber at dmax for 6MV (1.6cm) 100MU delivered with open 10x10cm 2 field 100MU delivered with patient-specific beam with GRID compensator inserted Output factor found to be 0.894 Hand calc for GRID MU = 1500cGy/0.894 = 1678 MU

Case Examples: Case 1 EPID film taken after CBCT and shifts made to verify only tumor is located in the treatment field. After, the GRID is placed on the gantry and treatment is delivered.

Case Examples: Case 1 CT simulation 4/7/2014 EBRT 6/2/2014

Case Examples: Case 1 EBRT 6/9/2014 After final Tx 6/13/2014

Case Examples: Case 1 Almost 2 months post RT 8/5/2014

Case Examples: Case 2 40 year old male Squamous cell carcinoma of the tongue Fungating mass on upper chest/neck Non-responsive to chemotherapy Treated15 Gy in 1 fraction with GRID therapy Prescription following was 2 Gy for 35 fractions for a total of 70 Gy o Patient missed several fractions throughout course of treatment and did not show for the last fraction (received 68Gy of 70Gy) Patient has not returned for follow up visits however did show tumor response during treatment

Case Examples: Case 2 CT simulation 2/13/2014 EBRT 3/16/2014

Case Examples: Case 2 EBRT 4/18/2014 EBRT 4/25/2014

Case Examples: Case 2 CT - 2/6/2014 CT - 6/28/2014

Case Examples: Case 3 43 year old male Squamous cell carcinoma of the oropharynx with right parotid primary Non-responsive to chemotherapy Large, bulky tumor on neck/upper face Treated 15Gy for 1 fraction of GRID therapy Followed by 2Gy for 35 fractions for a total of 70Gy

Case Examples: Case 3 CT simulation 6/11/2014 GRID 6/23/2014

Case Examples: Case 3 CT simulation 6/11/2014 CBCT during EBRT 8/15/2014

Conclusion GRID therapy is a technique that can benefit large, advanced tumors Due to limitations for treating bulky tumors with high dose radiation, GRID therapy can be used to treat a large portion of tumor while sparing skin and normal tissues GRID therapy treats a large, single fraction of dose (15-20Gy) to incite rapid tumor response Skin toxicities limited due to spatial treatment with GRID

Conclusion GRID followed by conventional radiotherapy can effectively and safely treat rapidly growing tumors Using a GRID compensator instead of MLCs can save treatment time, total MU, and low dose leakage through MLC Easy and quick to plan Previously published studies prove the efficacy of the technique and how it can help patients with large, bulky tumors

References (1) Mohiuddin, M., Stevens, J. H., Reiff, J. E., Huq, M. S. and Suntharalingam, N. (1996), Spatially fractionated (GRID) radiation for palliative treatment of advanced cancer. Radiat. Oncol. Investig., 4: 41 47. doi: 10.1002/(SICI)1520-6823(1996)4:1<41::AID- ROI7>3.0.CO;2-M (2) High-dose spatially-fractionated radiation (GRID): a new paradigm in the management of advanced cancers. Mohiuddin, Mohammed et al. International Journal of Radiation Oncology Biology Physics, Volume 45, Issue 3, 721-727 (3) Adeel Kaiser, Majid M. Mohiuddin, and Gilchrist L. Jackson. (2012). Dramatic response from neoadjuvant, spatially fractionated GRID radiotherapy (SFGRT) for large, high-grade extremity sarcoma. Journal of Radiation Oncology. doi:10.1007/s13566-012-0064-5 (4) Buckey, Courtney et al. Evaluation of a commerciallyavailable block for spatially fractionated radiation therapy. Journal of Applied Clinical Medical Physics, [S.l.], v. 11, n. 3, apr. 2010. ISSN 15269914.